Loading...
HomeMy WebLinkAbout7-Eleven 38944 Drawings Signed 11-18-20GENERAL NOTES:CODES AND STANDARDS·STRUCTURAL DESIGN BASED ON THE 6TH EDITIONOF THE 2017 FLORIDA BUILDING CODE.DESIGN·WIND SPEED = 150 MPH (3 SEC GUST)116 MPH (NOMINAL)·EXPOSURE - B·Kd = 0.85·CONSTRUCTION TYPE - I OR II (NONCOMBUSTIBLEMATERIALS)SOIL·ALLOWABLE BEARING CAPACITY = 2,000 PSF·ALLOWABLE LATERAL SOIL CAPACITY = 150 PSFCONCRETE STRENGTH·MINIMUM 28 DAY COMPRESSIVE STRENGTH OFPRECAST ELEMENTS F'c=5,500 PSI·MINIMUM 28 DAY COMPRESSIVE STRENGTH OFCAST IN PLACE CONCRETE F'c=2,500 PSIMATERIALS:·CEMENT PER ASTM C-150 TYPE 1AGGREGATES FOR CONCRETE:·NORMAL WEIGHT AGGREGATE: FINE AND COARSEAGGREGATE PROVISIONS AND TEST METHODSSHALL MEET ASTM C33. MAXIMUM AGGREGATE SIZEOF 3/4".ADMIXTURES:·NO ADMIXTURES SHALL CAUSE AN INCREASE INSHRINKAGE WHEN TESTED IN ACCORDANCE WITHASTM C494 AND C157DELIVERY OF CONCRETE:·DISCHARGE OF THE CONCRETE SHALL BECOMPLETED WITHIN 1-1/2 HOURS AFTER THEINTRODUCTION OF THE MIXING WATER TO THECEMENT AND AGGREGATES OR THE INTRODUCTIONOF THE CEMENT TO THE AGGREGATES.·WATER SHALL NOT BE ADDED IN THE FIELD UNLESSAPPROVED BY THE ENGINEER.UTILITIES·IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOLOCATE ALL OVERHEAD AND UNDERGROUNDUTILITIES PRIOR TO CONSTRUCTING THE FENCEAND/OR FOUNDATIONS. CONTRACTOR SHALLNOTIFY LOCATION OF ALL UTILITIES TO BOTH THEOWNER AND SITE ENGINEER PRIOR TOCONSTRUCTING FENCE AND / OR FOUNDATIONS.NOTES:1) CONTRACTOR TO REFER TO CIVIL DRAWINGS FOR WALL LAYOUT.SHEET 1SHEET 2DRAWING INDEXDWG. NO. TITLECOVER SHEET & GENERAL NOTESSHEET 38' PERMAWALL 2.0 DIMENSIONS8' PERMWALL 2.0 FOUNDATION, PANEL, and COLUMN DETAILSCUSTOMER:WILSON PETROLEUMPROJECT7 ELEVEN 389447310 INDRIO RD.FT. PIERCE, FL 34952PROJECT NUMBER: JD2374WALL TYPE:8 FT. PERMAWALL 2.0 (SAND FINISH)WIND DESIGN: 150 MPH (3 SEC. GUST) 116 MPH (NOMINAL)EXPOSURE: BRISK CATEGORY 1Prepared ByJBM & R ENGINEERING, INC. P.O. BOX 1566 VALRICO, FL 33595TEL: 813.598.4643 (CELL) 813.741.2109 (OFFICE) 813.655.0061 (FAX)Florida Registration No. 39610Ralph Remmert, P.E.NOVEMBER 18, 2020C.A.N. # 7457CONSTRUCTION PLANS & SPECIFICATIONS FORPERMACAST PRECAST CONCRETE FENCEThis item has been Electronically Signed and Sealed by Ralph Remmert, Florida P.E. #39610 using a SHA-1 Authentication Code. Printed Copies of the Document are not considered Signed and Sealed and the SHA-1 Authentication Code must be verified on any electronic copies. 20'-0"20'-0"8'-0"TYPICAL 8 FT. X 20 FT. WALL ELEVATION - GENERAL DIMENSIONSWALL PLAN VIEW - GENERAL DIMENSIONSFOUNDATION(SEE SHEET 3)FOUNDATION SIZE(SEE SHEET 3)COSMETIC BAND20'-0" (*)4" PANEL THICKNESSSCALE: 14" = 1'0"(*): 20'-0" - Contact Manufacturer for Exact Center to Center DistanceGROUND SURFACE20'-0" (*)1'-2" 812"SOLID COLUMNS(PER CONTRACT)14"PRECASTSANDFINISHPRECASTSANDFINISHOWNER IS RESPONSIBLE FOR DRAINAGEPATTERN AROUND NEW FENCE. JBM&RENGINEERING, INC. IS NOT RESPONSIBLEFOR SITE DRAINAGE REQUIREMENTS.SCALE: 14" = 1'0"20'-0" +/-1"2"1"1"4"12"516"1116"TYPICAL PANEL / POST CONNECTION1'-2"812"SCALE: 34" = 1'-0"SHEET 2SHEET 20Ralph E. Remmert, P.E.ENGINEERING, INC.JBM & RPO Box 1566 Valrico, FL 33595 Tel: 813.598.4643 (C) 813.741.2109 (O) 813.655.0061 (Fax)P.E. #39610C.A.N. #74570CIVIL11-18-20rer11-18-20rer7eleven3894411-18-20rerACTUAL SCALE0AS NOTEDPERMACAST PRECAST CONCRETE FENCE7-Eleven 389447310 Indrio Rd.Ft. Pierce, FL 34952jd23748 FT GENERAL WALL DIMENSIONSThis item has been Electronically Signed and Sealed by Ralph Remmert, Florida P.E. #39610 using a SHA-1 Authentication Code. Printed Copies of the Document are not considered Signed and Sealed and the SHA-1 Authentication Code must be verified on any electronic copies. #4 VERTICAL REINFORCEMENT@ 24" O/C6 LB./CY FORTAFERRA FIBERMESHIN PANELS ANDBEAMSTYPICAL 8 FT. X 20 FT. PERMACAST 2.0 PANELSCALE: 12" = 1'-0"(7)-#4'S HORIZONTAL EQUALLYSPACED (8 FT PANEL)8'-0"3" CL (typ)4"3" CL (typ)8'-0"Precast Post toBottom of FoundationTYPICAL FOUNDATION for 8 FT. COLUMNSFOR PERMACAST 2.0 PANELS (20 FT. O/C)SCALE: 38" = 1'-0"GRADE LEVELGRADE LEVELOptional Pre-Cast Column Cap(per contract) . Cap to be Bondedwith Concrete Bonding Adhesive.Follow Manufacturer's Instructions. 8 ft. X 20 ft. Panel(See Reinforcement this Sheet)* Foundation ScheduleWall HeightFoundation Diameter (Inches)24" Diameter Foundation Depth (Inches)58" DepthSolid Fence Column per Contract8 ft. Wall Height on 20 ft. Centers30" Diameter 56" DepthConcrete Foundation2,500 psi @ 20'-0" o.c.Property Line /Easement / ROWInstall Foundation Minimum 2" fromProperty Line / Easement / ROW1'-2"112"312"312"3"212"3"812"312"312"7"3"3"8"1'-2"112"312"312"812"312"312"7"11"LINE SOLID POST DETAIL8-1/2" X 14"END SOLID POST DETAIL8-1/2" X 14"CORNER SOLID POST DETAIL8-1/2" X 14"1'-2"112"312"312"812"312"312"7"1/2"CHAMFER(TYPICAL)seeschedule534"534"212"seescheduleseeschedule* Reinforcement ScheduleColumn Reinforcement#6's EA. CORNER8 ft. High Columnson 20 ft. Centers1/2"CHAMFER(TYPICAL)1/2"CHAMFER(TYPICAL)SCALE: 1" = 1'-0"SHEET 3SHEET 30Ralph E. Remmert, P.E.ENGINEERING, INC.JBM & RPO Box 1566 Valrico, FL 33595 Tel: 813.598.4643 (C) 813.741.2109 (O) 813.655.0061 (Fax)P.E. #39610C.A.N. #74570CIVIL11-18-20rer11-18-20rer7eleven3894411-18-20rerACTUAL SCALE0AS NOTEDPERMACAST PRECAST CONCRETE FENCE7-Eleven 389447310 Indrio Rd.Ft. Pierce, FL 34952jd2374POST, PANEL, and COLUMN DETAILSThis item has been Electronically Signed and Sealed by Ralph Remmert, Florida P.E. #39610 using a SHA-1 Authentication Code. Printed Copies of the Document are not considered Signed and Sealed and the SHA-1 Authentication Code must be verified on any electronic copies.