HomeMy WebLinkAbout18 - G6.0 REMOTE VENT AND DETAILS-G6_DS_11-18-20AIR/VACUUM BY AIR-SERV GROUP, LLCELECTRICAL STUB-UP WITHELECTRICAL WEATHERPROOF BOXFRONT1. ELECTRICAL NEEDS ARE #10 WIRE (30 AMP) WITH GROUNDNOTE:MAXIMUM 2 PERCENT GRADE SLOPE EACH WAYREQUIRED FOR AMERICANS WITH DISABILITIES ACTFRONTPLAN3'-0"CONC CURB - REF CIVIL DRAWINGSMAX.2%SLOPEGC TO PROVIDE CONCRETE SLABAND UTILITIES. AIR SERV TO PROVIDEEQUIPMENT AND MAKE FINALCONNECTIONS.1'-6"6"5 1/2"MIN AA56'-0"AA53'-1" CENTER OF CARD READER3'-2" CENTER OF COIN SLOTCONCRETE PAVEMENT3'-0"6"3'-0"TOP OF GRADECONCRETE FOOTINGPER SPECS - 12" DIASONOTUBE X 36" LONG12"DIA6"4'-1"2H011PAINT VENT PIPES "EXTRA WHITE" SW7006.2PAINT VENT RACK, BOLLARDS AND ALL OTHEREXPOSED METALS "SEAL SKIN" SW7675.UDP2" SCHED 40 BLACK IRONELBOW BY GCPLANFRONTSIDETYP3'-6"1'-4"1'-6"24"
8"MINIMUM 4000 PSI CONCRETE FOUNDATI0NPER MANUFACTURER'S SPECIFICATIONS.SEE SPECIFICATIONS FOR SLUMP TEST.4'-0"VENT CAPS TO BE12' ABOVE GRADE1'-9"10"TYP2" VENT RISER PIPINGSIDEFRONTREFERENCE 1-G1.0FOR ORIENTATIONOF VENT PIPES2N01S05S03G02T03H01S03L11L11L4521S05T32T1612' -0"2" BLACK IRONVENT RISER PIPING4'-1"G6.0REMOTE VENT AND DETAILS
KRA
TLHFUELING - USAJob#:A9-108
Scale:
Date:
Drawn By:
Checked By:
Rev. #Date Description
02/20/20
AS NOTEDSHEET:7-ELEVEN, INC.
3200 HACKBERRY ROAD, IRVING TEXAS 75063
Documents prepared by The
Dimension Group are to be used
only for the specific project and
specific use for which they are
intended. Any extension of use to
other projects, by owner or any
other party, without the expressed,
written consent of The Dimension
Group is done at the user's own risk.
If used in a way other than that
specifically intended, user will hold
The Dimension Group harmless
from all claims and losses.
7-ELEVEN #38944
NWC OF INDRIO ROAD & KINGS HIGHWAY
FORT PIERCE, FL 34951ARCHITECTURE CIVIL ENGINEERING MEP ENGINEERING
10755 SANDHILL ROAD, DALLAS, TEXAS 75238
TEL: 214-343-9400 www.dimensiongrp.com Proto 11-05-18THIS ITEM HAS BEEN DIGITALLY SIGNED ANDSEALED BY TERRY HESSELTINE, PE ON 11/18/2020USING A DIGITAL SIGNATURE.PRINTED COPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNED AND SEALED AND THE SHAAUTHENTICATION CODE MUST BE VERIFIED ONANY ELECTRONIC COPIES11/18/2020COMPANY:SIGNATURE:DATE:LICENSE NO.:THE POLLUTANT STORAGE SYSTEM SPECIALTYCONTRACTOR (PSSSC) HAS YET TO BE DETERMINED