Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Torres Residence Sealed
PROJECT DESCRIPTION. GOVERNING CODES: SHEET INDEX PROJECT SITES -A Castillo FLORIDA RESIDENTIAL CODE,6th EDITION 2017(FRC) A-00 PLOT PLAN &VICINITY MAP " En�rineerinpq 67x320 SILFAB SOLAR: SIL-320 NL(320W) MODULES FLORIDA PLUMBING CODE, 6th EDITION 2017(FPC) A-01 SYMBOLS&SYSTEM DESCRIPTION Engineering ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES FLORIDA BUILDING CODE,6th EDITION 2017 EDITION(FBC) S-01 ROOF PLAN & MODULES DESIGNED TO PERMIT SYSTEM SIZE: 21.440 kW DC STC FLORIDA MECHANICAL CODE,6th EDITION 2017(FMC) S-02 STRUCTURAL ATTACHMENT DETAILS CASTILLO ENGINEERING ARRAY AREA#1: 91.48 SQ FT. NEC 2014 CODE BOOK E-01 ELECTRICAL LINE DIAGRAM SERVICES, LLC ARRAY AREA#2: 494.00 SQ FT. E-02 WIRING CALCULATIONS • 620 N.WYMORE ROAD, ARRAY AREA#3: 548.88 SQ FT. E-03 SYSTEM LABELING SUITE 250, ARRAY AREA#4: 91.48 SQ FT. , M TE LAND,FL 375 DS-01-05 DATA SHEETS ERMOCRATES E.CASTILLO�FL PE 52590 EQUIPMENT SUMMARY COPYRIGHTED BY 67 SILFAB SOLAR: SIL-320 NL(320W)MODULES CASTILLO ENGINEERING 67 ENPHASE: IQ7-60-2-US MICROINVERTERS SERVICES,LLC REVISIONS DEVINE RD DESCRIPTION DATE REV -285-02' 40 PROJECT INSTALLER F w I o ` psommally PES X22 SOL R R < Cn Z ( SignE ure with Seal > Digitally sign Ed 2 HOUSE PHOTO byErmocrate Castillo p �� . =�o Date: A-00 SCALE: NTS ` ��� " " 2020.11.18 N ROOF#3 09:18:46-05'0 ' PROJECT SITE 2 (30)SILFAB SOLAR: SIL-320 PROJECT NAME NL(320W) MODULES T --58-00' C) f � Ir1Clliin River , ROOF#2 I U-141-00' -� N 'State College 2 (27)SILFAB SOLAR: SIL-320 I Imo. ® W p oo NL(320W) MODULES ort Pierce Of 1-STOR South apt �_ ® HOUSE ROOF#4 (n W LL (05)SILFAB SOLAR: SIL-320 . W Z > W (E)STRUCTURE (TYP.) NL(320W) MODULES � U W (n 0 W POOL I W 00 � CD O O LL White City Indian R40 • 'v SHEET NAME Estates (E) MAIN DISTRIBUTION PANEL PLOT PLAN & ROOF#1 —285-02' VICINITY MAP (05)SILFAB SOLAR: SIL-320 NL(320W) MODULES SHEET slzE N ANSI B 11" X 17" 1 PLOT PLAN WITH ROOF PLAN W, i- ; E 3 VICINITY MAP SHEET NUMBER A-00 SCALE: 1/32"= V-0" A_oo 5 A-00 SCALE: NTS Castillo � Engineering Qw DESIGNED TO PERMIT- Symbols: Abbreviations: CASSERVITILLO SERVICES, RING Y SERVICES, LLC COA#28345 Sheet where 620 N.WYMORE ROAD, section is located SUITE 250, Section.............. X sec MAITLAND,FL 32751 x-xx AC Alternating Current TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 Detail ID Letter APPROX Approximate System Description X YRIGHTED BY Elevation........... Sheet where CASTIILO ENGINEERINGX-XX section is located AWG American Wire Gauge SERVICES,LLC Detail ID Letter CB Combiner Box This system is a grid-tied, PV system, with PV generation consisting of REVISIONS Detail................ X Sheet where 67 SILFAB SOLAR SIL-320 NIL (320W) MODULES with a combined STC rated do DESCRIPTION DATE REV x-xx section is located DC Direct Current output power of 21440W. The modules are connected into 67 ENPHASE Detail ID Letter IQ7-60-2-US MICROINVERTERS. The inverter has electronic maximum power Detail................ X DCD Direct Current Disconnect x-xx Area to be enlarged (Enlarged Plan) DISC Disconnect point tracking to maximize energy captured by the PV modules. The inverter also Sheet where has an internal round fault detection and interruption device that is set to section is located g p Keyed Notes.......... Keyed note designation (E) Existing disconnect the array in the event that a ground fault that exceeds one ampere PROJECT INSTALLER 1 on applicable sheet EL Elevation should occur. The inverter has DC and AC disconnect integrated system and PES labels are provided as required by the National Electric Code Ali S O L A R Ground Terminal..... EQ Equal � JB Junction Box Signa ire with Seal Digitally signec Grounding Point/rod.... MCB Main Combiner BOX by Ermocrate lo MFR Manufacturer PV Modules .... u Dat e e:'° , Cast: - �`'g' � � Solar Panel......... or MICrOlnverters� 2020.11.18 00— Module with source MIN Minimum Circuit number Junction Point of O 09:18:53-05' 0 MISC Miscellaneous BOX Utility PROJECT NAME Combiner Box.......... CB Connection (N) New Utility Meter OCPD OverCurrent Protection Device W DC Disconnect.......... DCD POCC Point Of Common Coupling When the sun is shining, power from the PV array is fed into the inverter, W o co PV Photovoltaic where it is converted from DC to AC. The inverter output is then used to 0 w U_ Main Distribution MDP Panel ...................... contribute to the power requirements of the occupancy. If PV power meets the w z LLi SF Squarefoot/feet requirements of the loads of the occupancy, any remaining PV power is sold back (ifw � Fuse ...................... STC Standard Test Conditions (n o w to the utility. When utility power is available, but PV power is not available, Lu M - TBD To Be Determined building loads are supplied by the utility. � N F_ OvercurrentBreaker.. _1� The inverter meets the requirements of IEEE 1547 and UL 1741. This means p TYP Typical that if it detects a loss of utility power, it will automatically disconnect from the � Inverter.................... O `� VIF Verify In Field utility. When utility voltage is restored, the inverter automatically reconnects to i WP Weather Proof the utility grid after verifying utility voltage and frequency stability. On a day with average Florida sunshine, this system outputs 91.52 kWh per SHEET NAME 0 Transformer............. day on site. SYMBOLS &SYSTEM DESCRIPTION Automatic............... ATS SHEET SIZE Transfer Switch ANSI B 11" X 17" SHEET NUMBER A-01 MODULE TYPE, DIMENSIONS & WEIGHT Castillo�n GENERAL INSTALLATION PLAN NOTES: iIi MODULE FRAME DYNORAXX DYNOBOND NUMBER OF MODULES=67 MODULES Engineering SEE SPEC. SHEET/DS-05 MODULE TYPE=SILFAB SOLAR: SIL-320 NIL(320W)MODULES 1)ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS DESIGNED TO PERMIT• MODULE WEIGHT=41.01 LBS/18.6 KG. SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: CASTILLO ENGINEERING MODULE DIMENSIONS=66.92"x 39.37"= 18.30 SF UNIT W 620 N. YMOEIGHT OF ARRAY=2.24 PSF SERVICES,LLC WIND ZONE 1: MAX SPAN 6'-0"O.C. -MAX CANTILEVER 1'-4" WYMO E RE ROAD, WIND ZONE 2: MAX SPAN 4'-0"O.C. -MAX CANTILEVER V-4" SUITE250, L 32751 WIND ZONE 3: MAX SPAN 2'-0"O.C. -MAX CANTILEVER 0'-8" M TELAND,F-2575 PV MODULE (E) FRONT YARD TEL:.CAS89-2575 SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. ERMocRnresE.cnsrlLLo-FL PEszSso COPYRIGHTED BY (113)PV ROOF ATTACHMENT 2)EXISTING RESIDENTIAL BUILDING IS A METAL ROOF WITH MEAN CASTILLO ENGINEERING @ 72"&48"O.C. ROOF HEIGHT IS 15 FT AND SYP 2X4 ROOF TRUSSES SPACED 24" SERVICES,LLC (N)QRAIL LIGHT(TYP.) O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS REVISIONS (N)(67)ENPHASE: IQ7-60-2-US 22.6 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL DESCRIPTION DATE REv ARRAY & ROOF AREA WIND ZONE 1 (TYP.) MICROINVERTERS REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST ROOF#3 ROOF#3 BETWEEN PLANS AND IN FIELD CONDITIONS. CALC'S (ROOF #1) WIND ZONE 2 (TYP.) (30)SILFAB SOLAR: SIL-320 TILT-22.6° ARRAY AREA=91.48 SQ. FT. WIND ZONE 3 (TYP.) NIL(320W)MODULES AZIM.-361 I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN ROOF FACE AREA= 190.90 SQ. FT. 851_2" COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING 91.48/ 190.90 =47.92 % OF ROOF STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT FACE AREA COVERED BY ARRAY WIND LOADS AND EQUIPMENT DEAD LOADS. DESCRIPTION (ROOF #1) PROJECT INSTALLER ROOF TYPE-METAL ROOF PES ROOF TILT-22.6° N ROOF AZIMUTH -270° TRUSSES SIZE-2"X4" @ 24"O.C. w s A■ m�, S O L ARRAY & ROOF AREADigitally Signat ire CALC'S (ROOF #2) sl Seal b J Y s Ermocrates ARRAY AREA=494.00 SQ. FT. Castillo ROOF FACE AREA= 1240.96 SQ. FT. 494.00/1240.96=39.81 %OF ROOF oa.. Date: �.,�,..< FACE AREA COVERED BY ARRAY 2020.11.18 DESCRIPTION (ROOF #2) o9:ls:sa ROOF TYPE-METAL ROOF PROJECT r ROOF TILT-22.6° 171 0 1 ,m ] I 1 0 _ 3f 9'37�,1 ROOF AZIMUTH - 180° TRUSSES SIZE-2"X4" @ 24"O.C. ROOF#2 w ( )SILFAB SOLAR: SIL-320 ARRAY & ROOF AREA NL (320W) MODULES z o tz co rn CALC'S (ROOF #3) rn WD co ARRAY AREA=548.88 SQ. FT. r/AROOF FACE AREA= 1367.92 SQ. FT. 3/4" IMC, RMC, FMC, LFMC, PVC, CO W 548.88/1367.92=40.13%OF ROOF ROOF#2 HDPE, NUCC, RTRC, LFNC, FMT, W Z LLI FACE AREA COVERED BY ARRAY TILT-22.6° ENT OR EMT CONDUIT RUN W U DESCRIPTION (ROOF #3) (N)SOLADECK AZIM. 180° o w ROOF TYPE-METAL ROOF (E) UTILITY METER o SILFAB SOLAR: W 00 ROOF TILT-22.6° (E) MAIN �' SIL-320 NL (320W) 0� LO I--- ROOF AZIMUTH-360° DISTRIBUTION PANEL MODULES 0� cV O� TRUSSES SIZE-2"X4"@ 24"O.C. (N)AC DISCONNECT ARRAY & ROOF AREA (IF REQUIRED) LEGEND I� CALC'S (ROOF #4) (N) PV METER ® _ UM -UTILITY METER ARRAY AREA=91.48 SQ. FT. (IF REQUIRED) SD SOLADECK ROOF FACE AREA= 272.98 SQ. FT. (N) PV COMBINER BOX ACp 91.48/272.98 = 33.51 % OF ROOF AC DISCONNECT SHEET NAME ROOF PLAN & FACE AREA COVERED BY ARRAY TAIPM - PRODUCTION METER DESCRIPTION (ROOF #4) RF#1 ROOF#4 MpP MAIN DISTRIBUTION PANEL MODULES ROOF TYPE-METAL ROOF TILOOT-22.6° TILT-22.6° ROOF TILT-22.6° AZIM.-270° AZIM.-90° VENT,ATTIC FAN (ROOF OBSTRUCTION) SHEET SIZE ROOF AZIMUTH -90° (E) BACK YARD ANSI B TRUSSES SIZE-2"X4" @ 24"O.C. PV ROOF ATTACHMENT 11" X 17" ROOF#1 ROOF#4 -TRUSSES ROOF PLAN & MODULES (05)SILFAB SOLAR: SIL-320 (05)SILFAB SOLAR: SIL-320 -CONDUIT SHEET NUMBER NIL (320W)MODULES NIL (320W)MODULES S-01 SCALE:3/32"= 1'-0" CB -COMBINER BOX S-01 Castillo SolarFoot Engineering Top (4x)0.315[08. 130 DESIGNED TO PERMITa 120 115 CASTILLO ENGINEERING 1 lis 139 SERVICES, LLC 250 120 COA#28345 620 N.WYMORE ROAD, a wlo.o.w SUITE 250, .32 ba - va j�;� "'e", MAI��(aoDzas-s2551 0 0 ua.-tar �t _ ERMOCRATES E.CASTILLO-FL PE 52590 2.00 1.50 1Pa"nted 140 ~ 140 COPYRIGHTED BY 1.00 -O- -O- 1 3 150 am atw ti, " CASTILLO ENGINEERING SERVICES,LLC 4�� -+ 1 150 3.67 a`. REVISIONS � .50 140 DESCRIPTION DATE REV "ems 1.83 mas 160 Notes: 150 1. Values a Wth,,do design 3-second gt Mt 3.17 rind speeds in us Milos per h... (a/c)at 33 170 Et (14r)atu-R...nd Enr Evposure C .gory. I„,Pr., 3.67 2. Linear interpolation bet-contours 160 is permitted. Back 3. Island,and coastal areas outside the c... cast cpntoou shawl use thr lest rind speed am Left Front Right °nt°ur `tie t ataI r... 170 M8-1.25 Threaded Stud g 4. aauntainoas terrain, meanPROJECT INSTALLER prmntories.aM special�Meregio s ur �� I hall be era loco far unusual ring eenet- PES clone. $. Mind speeds cor-,-"d to a-r,,,-t,ly 180 t. 67 a 7%probability of- dance i se years /� (Annual E-eedence Probability =0.00143, S �..! L R R I MRI = 700 years). \,Moir/ 1.32 Mod 66 .32 Diqetally Signa ure with- eal FIGURE'1609.3('l) signe d by Ermocrates E ULTIMATE DESIGN WIND SPEEDS, Vt2T,FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES 1.39 2, LL- Castillo Factory Applied '$ `° Date: Butyl Seala 2020.11.18 1. Wind Speed Ult(mph) 160 Roof Slope Calculator 09:19:07 Risk Category II Rise Run Slope(°) 3,4• Wind Speed ASD(mph) 130 5 12 22.6 PROJECT NAME General Notes: Exposure Category C 1. SolarFoot _ Mean Roof Height(ft) 15 s Roof Slope(degrees) 25 Maximum Uplift per*fastener w 2. M8-1.25 Stainless Steel Hex Flange Nut (13mm Socket) s Module Area(sq ft) 20 Wind Zone 1 539.1 U 00 3. Metal to Metal:1/4-14 Self Drilling Screw 1-1/2"to 2-1/2" K2t 1 Z Metal to Wood:1/4-14 Type 17 AB Milled Point 1-1/2" to 2-1/2" Height Adjustment 1.z1 Per American Wood Council- w co NDS Max Withdraw Load for(2) 4. Example roof 625 0 1/4"LAGs with 2.5" - W ILL. DYNOBOND JUMPER Embedment W Z LLI M10-1.5x16 MM BOLT (N)QUICKMOUNT QRAIL LIGHT(TYP.) Roof Zone Pnet(30) *Roof attachements w 2 rails at: 6 ft O/C Of W (N)MID CLAMP 1 16 -27 (E)STANDING (N)END CLAMP W LU 2 16 44.6 SEAM ROOF �J J 0 3 16 -67 Maximum Uplift per*fastener L.f_ L0 593.6 N Wind Zone 2 Of O ® ® ® Per American Wood Council- O LL P-net=Q K� zt P-(net(30)) NDS Max Withdraw Load for(2) 625 � Roof Zone Pnet 1/4"LAGS with 2.5" 0 1 19.36 -32.67 Embedment 2'ZONE 3 (TYP.) S-5 SOLAR FOOT 2 19.36 -53.966 *Roof attachements w 2 rails at: 4 ft O/C STRUCTURAL SHEET NAME 12" SEAM SPACE 3 1936. -81.07 4'ZONE 2 (TYP.) 2 1/4"X 2.5"LAG BOLTS ATTACHMENT (E)2x4 TRUSS Maximum Uplift per*fastener DETAILS 445.9 6'ZONE 1 (TYP.) Wind Zone 3 SHEET SIZE Per American Wood Council- ANSI B NDS Max Withdraw Load for(2) 625 11" X 17" 1 ATTACHMENT DETAIL 1/4"LAGS with 2.5" S-02 SCALE: 1" = 10" Embedment SHEET NUMBER *Roof attachements w 2 rails at: 2 ft O/C e_02 Castillo SOLAR ARRAY 21.440 kW-DC STC Engineering 4 ti ti 4 (67) SILFAB SOLAR:SIL-320 NL(320W)MODULES DESIGNED TO PERMIT" - - - - - - - - - - (02)BRANCH OF 14 MODULES CASTILLO ENGINEERING (03)BRANCH OF 13 MODULES SERVICES, LLC COA#28345 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 ti TEL:(407)289-2575 NOTE; ERMOCRATES E.CASTILLO-FL PE 52590 Q CABLE 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE COPYRIGHTED BY DYNOBOND JUMPER REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY CASTILLO ENGINEERING THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, SERVICES,LLC INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, REVISIONS 4-- — — — — — — — 4- 4-4- 4- 4-4-4-4— q MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER,AS APPLICABLE. DESCRIPTION DATE REV 4— 4— 4— 4— 4— 4— 4— 4— 4— 4— 4— 4 r INTERCONNECTION 120%RULE-CEC 705.12(D)(2)(3)(b) Q CABLE UTILITY FEED+SOLAR BACKFEED 150A+90A=240A PROJECT INSTALLER BUSS RATING x 120% 200A x 120%=240A , PES G G G G G G G G G G G G G ENPHASE:IQ7-60-2-US MICROINVERTERS ������ S O L R R PV MODULES Signa ure wi ea signed by Ermocrates E TO UTILITY GRID Castillo Date: 2020.11.18 L1 L2 N(2)10/2 ROMEX RUN IN ATTIC 09:19:14 OR BI-DIRECTIONAL = (2)#10 AWG THWN-2-RED � UTILITY METER PROJECT NAME (2)#10 AWG THWN-2-BLACK (N)SOLADECK EGC#10 AWG THWN-2 (N)AC DISCONNECT: 1-PHASE,240V 600 V,NEMA 3R IN 3/4"PVC,IMC,RMC,FMC, 240V,100AMP RATED, G L2 a L2 a L2 L1 G L2 L1 L2 a UL LISTED LFMC,HDPE,NUCC,RTRC, NEMA 3R,UL LISTED, L1 L2 N LFNC,EMT,FMT,OR ENT (N)PV METER LOCKABLE&NON-FUSIBLE, LI J CONDUIT RUN (N)125A PV COMBINER BOX,240V (IF REQUIRED) (IF REQUIRED) ( , G L2 Lt L2 L1 L2 L1 G L2 L1 L2 Lt v L1 L2 N (E)MAIN DISTRIBUTION 7 � L1 L1 L1 L1 L1 PANEL,200A RATED,240V. w � LucoL2 2 oo°O° L L2 L2 (3)10/2 ROMEX RUN IN ATTIC N N N N N J LL OR G — — — G G - - — G G - - _ (3)#10AwGrHWN-2-RED 1oA (E)MAIN BREAKER w > U (3)#10 AWG THWN-2-BLACK - 150A/2P,240V EGC#10 AWG THWN-2 LU IN 3/4"PVC,IMC,RMC,FMC, LLI LFMC,HDPE,NUCC,RTRC, LIJ � 0- LFNC,EMT,FMT,OR ENT CO CONDUIT RUN 20A/2P (3)#4 AWG THWN-2 n/ LG L1 (1)#8 AWG THWN-2 GND L1 F. N N IN 1"PVC,IMC,RMC,FMC, L2 LFMC,HDPE,NUCC,RTRC, L2 L2 O LL 20A/2P LFNC,EMT,FMT,ENT L1 CONDUIT RUN V L1 L2 zowzP L2 L1 90A/2P L2 L1 L1 SHEET NAME 20A/2P L1 L2 L2 Lz ELECTRICAL 20A/2P LINE DIAGRAM L1 N G SHEET SIZE L2E — - — — — — — — — — — — — — — EXISTING GROUNDING ELECTRODE SYSTEM ANSI B NG 11" X17" 1 ELECTRICAL LINE DIAGRAM SHEET NUMBER E-01 SCALE: NTS E-01 AC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: Castillo FROM ROOF TOP SOLADECKTO LOAD CENTER FROM AC COMBINER BOX TO MSP Engineering DESIGNED TO PERMIT" MODULE MANUFACTURER SILFAB MODULE PROPERTIES CASTILLO ENGINEERING MODULE MODEL SIL-320 NIL 7�3M 40.1 Isc 10. ELECTRICAL NOTES SERVICES,LLC INVERTER MANUFACTURER ENPHASE P 32.88 IMP 9.74 COA#28345 620 N.WYMORE ROAD, INVERTER MODEL ENPHASE IQ 7 TOOC -0.50%/K TC VMP -0.65%/K 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND SUITE250, MODULES/BRANCH CIRCUIT 1 14 320.❑ NOCT 45 °C LABELED FOR ITS APPLICATION. MAITLAND,FL32751 TEL:(407)289-2575 MODULES/BRANCH CIRCUIT 2 14 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 ERMOCRATES E.GASTILLO-FL PE 52590 MODULES/BRANCH CIRCUIT 3 1 3 DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR COPYRIGHTED BY MODULES/BRANCH CIRCUIT 4 13 75 DEGREE C. CASTILLO ENGINEERING MODULES/BRANCH CIRCUIT 5 13 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. SERVICES,LLC TOTAL ARRAY POWER (KW) 21.44 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SYSTEM AC VOLTAGE 240V 1-PHASE REVISIONS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS INVERTER PROPERTIES DESCRIPTION DATE REV ,1111115 DESIGN TEMPERATURE OUTPUT VOLTAGE 240 L-L 1-PH POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. MIN. AMBIENT TEMP. °F 32 MAX INPUT DC VOLTAGE 48 VDc 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING MAX. AMBIENT TEMP. -F 1 1 7 OPERATING RANGE 1 6 - 48 VDc ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. CALCULATED MAX. VOC 43 MPPT VOLTAGE RANGE 27 - 37 VDc 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CALCULATED MIN VMP 26 START VOLTAGE 22 VDc CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, CONDUIT FILL MAX INPUT POWER 350 WOO SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE NUMBER OF CONDUITS 2 CONTINUOUS AC POWER 240 VA CODES AND STANDARDS. PROJECT INSTALLER 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS AMPACITY CALCULTIONS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM CIRCUIT MAX AMPS 1-25 x AWG 9❑ 'C AMBIENT TEMP CONDUIT FILL DERATED MAXIMUM CIRCUIT ACCORDINGLY. 1 PES MAX AMPS AMPACITY TEMP 'F DEBATE FILL DEBATE AMPACITY BREAKER 8, ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ���No! S O L R R CIRCUIT 1 1 4.E) 1 7.5 #1❑ 40 130 0.76 5 O.B 24.32 211 A AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP signs m witi sea CIRCUIT 2 1 4.❑ 17.5 #1❑ 4❑ 130 0.76 5 O.B 24.32 2❑ A Digitally Slg 24.32 MANUFACTURER'S INSTRUCTION. •„qyr„ _�_ by Ermocrate CIRCUIT 3 13.0 16.3 #1❑ 40 130 0.76 _ 0.0 20 A 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E Castillo �'•�:JE"SF -.gym r��m. 24.32 G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. CIRCUIT 4 13.0 1 6.3 #1❑ 40 130 0.76 O.8 20 A Date: CIRCUIT S 13.0 1 6.3 #1❑ 4❑ 1 3❑ ❑.76 5 O.8 2❑ A 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . a ewe 24.32 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL 2020.1 1.18 AD COMBINER 67.0 83.8 #4 95 95 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE 09:19:20-05' PANEL OUTPUT 11 96 3 1 91 .2 90 A ENTRANCE. PROJECT NAME 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. MAXIMUM CIRCUIT VOLTAGE DROP z% 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS w SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1)AND ARTICLE () 00 VOLTAGE DROP CALCULATIONS CIRCULAR MAX 310.10 (D). Z CIRCUIT Awe MILLS LENGTH I v 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE W M CIRCUIT 1 #1❑ 10380 14.0 240 1 36 FEET FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 0 J W W CIRCUIT 2 #1❑ 10380 14.0 240 �1 3B FEET z CIRCUIT 3 #111 10380 13.0 240 149 FEET W U CIRCUIT 4 #1❑ 103811 13.0 2411 1413 FEET LL uJ ry CIRCUIT 5 #1❑ 1 0380 13.0 240 1 49 FEET ENPHASE IQ7-60-2-US MICROINVERTER W 0 W COMBINER PANEL OUTPUT #4 41 740 67.0 240 1 1 6 FEET Input Data(DC) W O' 00 Recommended Input Power(STC) 235-350W+ 13� N F_ NOTES Maximum Input DC Voltage 48V O O TEMP DERATE BASED ON NEC TABLE 31 0.15(9)(2)(A) 0 ILL Peak Power Tracking Voltage 27V-37V 0 CONDUIT FILL DERATE BASED ON NEC TABLE 310.15(9)(3)(A) MAXIMUM VOC CALCULATED USING MODULE MANUFACTURE TEMPERATURE COEFFICIENTS PER NEC 690.7(A) Operating Range 16V-48V UNLESS OTHERWISE SPECIFIED, ALL WIRING MUST BE THHN OR THWN-2 COPPER Min./Max.Start Voltage 22V/48V ALL WIREgSIZES LISTED ARE THE MINIMUM ALLOWABLE CELL INDICATES THAT THE SYSTEM IS SAFE AND COMPLIES WITH NEC REQUIREMENTS Max DC Short Circuit Current 15ASHEET NAME CELL INDICATES A POTENTIALLY UNSAFE CONDITION Output Data(AC) WIRING ATION INPUT BY SYSTEM DESIGNER CALCULATIONS ATION OBTAINED FROM MANUFACTURER DATASHEETS Maximum Output Power 240W Nominal Output Current 1A SHEET SIZE I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER Nominal Voltage/Range 240V/211-264V LICENSED PURSUANT TO CHAPTER 471, CERTIFY ANSI B THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL Nominal Frequency/Range 60 Hz 11 II X 17" COMPONENTS ARE DESIGNED AND APPROVED USING Extended Frequency/Range 47-68 Hz THE STANDARDS CONTAINED IN THE MOST RECENT Power Factor at rated power 1.0 SHEET NUMBER VERSION OF THE FLORIDA BUILDING CODE. FBC 107. Maximum unit per 20A Branch Circuit 16(240 VAC) E-02 Castillo A WARN IN GA PHOTOVOLTAIC SYSTEM AC DISCONNECT PHOTOVOLTAIC SYSTEM Engineering ELECTRIC SHOCK HAZARD RATED AC OPERATING CURRENT 67.0 AMPS EQUIPPEDRAPID DESIGNED TO PERMIT" DO NOT TOUCH TERMINALS VOLTSAC NOMINAL OPERATING VOLTAGE 240 • CASTILLO ENGINEERING SHUTD TERMINALS ON BOTH LINE AND SERVICES,LLC COA#28345 LOAD SIDES MAY BE ENERGIZED LABEL LOCATION: 620 N.WYMORE ROAD, IN THE OPEN POSITION AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: SUITE 250, (PER CODE:NEC690.54) AC DISCONNECT,DC DISCONNECT,POINT OF MAITLAND,FL 32751 LABEL LOCATION: TEL:ta 52 07)219-2s75 AC DISCONNECT,POINT OF INTERCONNECTION INTERCONNECTION ERMOCRATESE.CASTILLO-FL PE 590 PER CODE:NEC 690.17(E),CB (PER CODE:NEC690.56(C)) COPYRIGHTED BY OUTPUT CONNECTION • . • • CASTILLO ENGINEERING PHOTOVOLTAIC SERVICES,LLC . . DEVICE POWER REVISIONS LABEL LOCATION: LABEL LOCATION: DESCRIPTION DATE REV CONDUIT,COMBINER BOX POINT OF INTERCONNECTION (PER CODE:NEC690.31(G)(3)(4)&NEC 690.13(G)(4) (PER CODE:NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM DATA PER PANEL LABEL LOCATION: • • • 240 POINT OF INTERCONNECTION (PER CODE:NEC 705.12(D)(4)) • • • 60 PROJECT INSTALLER MAXIMUM AC POWER- ADHESIVE _ ; FASTENED SIGNS: PES 240 �� S O L R R •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. MAXIMUM •VERCURRENT DEVICE RATING D* 20 Signa una wlt ea •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF FOR AC MODULE • • signed by PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER RESISTANT[IFC 605.11.1.3] Ermocrates usm� Castillo 7 LABEL LOCATION: °$' '" COMBINER BOX M" Date: (PER CODE:NEC690.52) 2020.1 1.18 09:19:30 PROJEC W U 00 Z W DM 0 J LU LL W z LLj 13� LU U (n 0 W_ W 0 13� U) H N ly 0 0 SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER E-03 Castillo Engineering ki DESIGNED TO PERMIT" CASTILLO ENGINEERING SERVICES,LLC 1 • • ' COA#28345 �•• 1 620 N.WYMORE ROAD, �.�. Test Conditions STC NOCT SUITE 250, Module Power(Pmax) Wp 320 242 MAITLAND,FL 32751 Maximum power voltage(Vpmax) v 32.88 29.59 TEL(407)289-2575 ERMOC RATES E.CASTILLO-FL PE 52590 z `- Maximum power current(Ipmax) A 9.74 8.18 Open circuit voltage(Voc) v 4010 37.09 8.46 CACOPYRIGHTED BY ILLO ENGINEERING S i Ifab Short circuit current(Isc) A 8.8 17.8 Module efficiency 46 18.8 17.8 SERVICES,LLC Maximum system voltage(VDC) v 1000 SOLAR Series fuse rating A 20 REVISIONS Power Tolerance Wp 0 to+10 DESCRIPTION DATE REV Measurement conditions:STC 1000 W/m2•AM 1.5•Temperature 25°C•NOCT 800 W/mz•AM 1.5•Measurement uncertainty s 3% •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by t5%and power by 0 to+1 ow. AMIKABLe .- _ 1 NIL mono PERC • '11 10 ...... T•D DNV'GL -___ • Metric Temperature Coefficient Isc 0.064%/°C 0.12%/OK Temperature Coefficient Voc -0.28%/°C -0.50%/OK Temperature Coefficient Pmax -0.36%/°C -0.65%/OK NOCT(t 2°C) 45°C 113°K • ' INDUSTRY LEADING WARRANTY O eratin tem erature -40/+85°C -40/+1851K PROJECTINSTALLER All our products include an industry • .. .. - 1 leading 25-year product workmanship Module weight 'I8.6 kg t0.2 kg 41 t0.4lbs PES and 30-year performance warranty. Dimensions(H x L x D) 1700 mm x 1000 mm x 38 mm 615.9 in x 39.4 in x 1.5 in 1 Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load N/m2 83.5/112.8 Ib/ftA2 \■■/O S O L R R Monocrystall 35+YEARS OF SOLAR INNOVATION Hail impact resistance 0 25 mm at 83 km/h 0 1 in @ 51.6 mph Cells 60-Si mono PERC-5 busbar 60-Si mono PERC-5 busbar Leveraging over 35+years of worldwide 158.75 x 158.75 mm 6.25 x 6.25 Inch PV Module experience in the solar industry,Silfab Glass 3.2 mm high transmittance,tempered, 0.126 Inch high transmittance,tempered, Signature with Seal is dedicated to superior manufacturing antlireflective coati- antireflective coating Cables and connectors(refer to installation manual) 1200 mm,In 5.7 mm,MC4 compatible 47.2 in, 0 0.22 in,MC4 compatible processes and innovations such as Backsheet High durability,superior hydrolysis resistance,multi-layer dielectric film Bifacial and Back Contact technologies, Frame Anodized AI(Black) to ensure our partners have the latest in Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) solar innovation. junction Box UL 3730 Certified,IP67 rated 1 NORTH AMERICAN QUALITY Module product workmanship warranty 25 years** 30 years PROJECT NAME © Silfab is the leading automated solar Linear power performance guarantee >97%end 1 'year >_90%end 12th year >_82%end 25th year >_80%end 30Lh year module manufacturer in North America. Is • I I WAIIIJ • . I EC MAS Fraunhofer ® Utilizing premium quality materials and ULC ORD C1703,UL 1703,CEC listed,IEC 62716 Ammonia Corrosion;IEC61701:2011 IF strict quality control management to deliver Product Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 W the highest efficiency,premium quality PV Factory IS09001:2015 - U 00 modules 100%made in North America. :::Modules Per Pallet:26 Eff vs.Irr Performance SIL-320 NIL ee Pallets Per Truck:36 LLJ M Modules Per Truck:936Chubb provides error and omission insurance to 19 25 nm�B E E � Q J A Warning.Read the Safety and Installation Manual 18 40°C LLl LL for mounting specifications and before handling �, MW' '/•� installing and operating modules. w 17 55°C ee o w z **12 year extendable to 25 years subject to regis- cam"- 16 70°C F �11 '` E E U tration and conditions outlined under"Warranty'at Lu t-L°""' g N www.silfabsolar.com. 15 11 11 _ "� ILL! L.1_ Third-party generated pan files from Fraunhofer- 0 14 E E � LLJ A A A ' • A • •• '• • • Institute for Solar Energy Systems ISE are available } 13 11 1 E LL• • • l l 1 -- 71fab panels are _ , , , • , •, , , modules ,automated for download at:www.silfabsolar.(:om/downloads 11 N 0 Buy American Act • • -•. • • • • • 1 1 • 12 I t E m LL 0 200 400 600 800 1000 1200US Military and FAA have al -s win the hearts and minds of E 0 Irradiance(W/ml) t 1 o a 0 solar • • • • • • • • •• •- C C , I "3 LL • • • tioz(zsm_) LIGHT • , Engineered toaccommodav EI Drawings not to scale to 411' •• •• • • •- •' • • • •- or wide-ranging •• •. • • • • • •• • 3e.37(tODDmm) ISHEET NAME Silfab Solar Inc. LOWEST "`"s;. 240 Courtneypark Drive East z Total automation ensures st . _ , technology. mater ="`'' Mississauga ON L5T 2Y3 Canada DATA SHEET • • • • • • • •. • . :1 z S. i I fa b`���` Tel+1 905-255-2501 Fax+1 905-696-0267 entire manufacturing SOLAR info@silfabsolar.com www.silfabsolar.com 48.18 ppm asper December 1 ©® Silfab Solar Inc. L� EL 19 TOP PERFORMER SHEET SIZE 800 Cornwall Ave _ Bellingham WA 98225 USA Ry MO DULENV GL ANSI B Tel+1 360-569-4733 RELIABILITY SCORECARD n 11" X 17" SHEET NUMBER DS-01 Castillo Engineering DESIGNED TO PERMIT" CASTILLO ENGINEERING SERVICES,LLC COA#28345 Data sheet Enphase IQ 7 and IQ 7+ Microinverters WYMORE SUITE 50ROAD, Enphase Microinverters MAITLAND,FL32751 Region:US INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US TEL:.CASTILLO ) ERMOCRATES 75 1 (07)289-2-FL PE 52590 Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ COPYRIGHTED BY Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules CASTILLO ENGINEERING Maximum input DC voltage 48 V 60 V SERVICES,LLC Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V REVISIONS The high-powered smart grid-ready Min/Max start voltage 22 V/48 V 22 V/60 V DESCRIPTION DATE REV Enphase Enphase IQ 7 MicroT"and Enphase IQ 7+Micro' Max DC short circuit current(module Isc) 15 A 15 A Overvoltage class DC port II II Q7 and IQ 7+ dramatically simplify the installation process while DC port backfeed current 0 A 0 A achieving the highest system efficiency. PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; M i e ro i nve irte rs AC side protection requires max 20A per branch circuit Part of the Enphase IQ System,the IQ 7 and OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter IQ 7+Microinverters integrate seamlessly with Peak output power 250 VA 295 VA PROJECT INSTALLER the Enphase IQ EnVOyT",Enphase Q Aggregator'" Maximum continuous output power 240 VA 290 VA Nominal(L L)voltage/range2 211 2/ 183 V/ 211 2/ 183 V/ PES Enphase IQ Battery'"",and the Enphase Enlighten'" 211-26av 183-229V 211-264V 183-229V monitoring and analysis software. Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A Nominal frequency 60 Hz 60 Hz S O L R R IQ Series Microinverters extend the reliability Extended frequency range 47-68Hz 47-68Hz standards set forth by previous generations and AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Signature with Seal undergo over a million hours of power-on testing, Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) g p g, 13(208 VAC) 11(208 VAC) enabling Enphase to provide an industry-leading Overvoltage class AC port III III warranty of up to 25 years. AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3 PROJECT NAME Easy to Install CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA IQ 7 Microinverter Lightweight and simple Ambient temperature range -400C to+650C • Faster installation with improved,lighter two-wire cabling Relative humidity range 4%to 100%(condensing) w Built-in rapid shutdown compliant(NEC 2014&2017) Connectortype MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) 0 00 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) z Weight 1.08 kg(2.38 Ibs) w M Productive and Reliable � Cooling Natural convection-No fans 0 J_ Optimized for high powered 60-cell and 72-cell*modules Approved for wet locations Yes (f) LU LL More than a million hours of testing Pollution degree PD3 U-1 ; LU d Class II double-insulated enclosure Enclosure Class II double-insulated,corrosion resistant polymeric enclosure 13� LU UL listed Environmental category/UV exposure rating NEMA Type 6/outdoor U) 0 LLI 0 FEATURES w � 0- Communication Power Line Communication(PLC) 00 Smart Gfld Ready Monitoring Enlighten Manager and MyEnlighten monitoring options. N ry Complies with advanced grid support,voltage and Both options require installation of an Enphase IQ Envoy. O frequency ride through requirements Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break 0 o • ILL Remotely updates to respond to changing disconnect required by NEC 690. grid requirements Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 Meets CA Rule 21 (UL 1741-SA) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC SHEET NAME and DC conductors,when installed according manufacturer's instructions. U *The IQ 7+Micro is required to support 72-cell modules. DATA SHEET 1.No enforced DC/AC ratio.See the compatibility calculator at bttps://enphase.com/en-us/su000rt/module-comoatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ® O'�' E N P H AS E To learn more about Enphase offerings,visit enphase.com E N P H AS E SHEET SIZE To learn more about Enphase offerings,visit enphase.com `/ V @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. ANSI I C+I B 2018-02-08 A V J 1111 X 17" SHEET NUMBER DS-02 Castillo Engineering -! DESIGNED TO PERMIT" ` CASTILLO ENGINEERING + ►: SERVICES,LLC t,. 1 COA#28345 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 ERMOCRATES E.CASTILLO-FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING r SERVICES,LLC _ - REVISIONS DESCRIPTION DATE REV QRai [TM— Fully Integrated Mounting and Racking System Fast, Simple Installation: It Just Clicks PROJECT INSTALLER , The QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar QCldlechnoloRy'M PES designers and installers.Combined with Quick Mount PV's industry-leading waterproof mounts,QRail offers a The universal mid and end clamps use patented QClick "� �—����� S O L R R complete racking solution for mounting solar modules on any roof. technology to simply"click"into the rail channel and Mom, remain upright, ready to accept the module.The Signature with Seal Easily design array configurations with the QDesign software pre-assembled clamps fit virtually all module frames and application.Generate complete engineering reports and calculate require no extra hardware,eliminating pre-loading and a precise bill of materials for all the mounting, racking and reducing installation time. UNIVERSAL END CLAMP UNIVERSAL BONDED MID CLAMP accessories needed for a complete solar array. 1 .+ 2 3 + 2 clamps for modules from 2 clamps for modules from 30-45mm or38-50mm thick 30-45mm or38-50mm thick PROJECT NAME click! Comprehensive, One-Source Solution Insta((ingisaseasyas123 U 00 QRail,together with Quick Mount PV's waterproof mounting products,provides the benefit of asingle-sourced, QSp11CC TochnoIoRy W o M 0 J seamlessly integrated rooftop installation that works with all roof types—composition/asphalt shingles, QRail's innovative internal QSplice installs in seconds, requiring no LU LL, flat or curved tile, metal shingle,shake,slate and low slope roofs.The QRail system also works with any roof tools or screws.Simply insert QSplice into the rail and slide the other W > U LU attachment system for maximum flexibility. rail on to create a fully structural, bonded splice.An external splice is QSPLICE 5; W � also available. U) _ W CD CO Superior Strength and Versatility 1 2 3 Of N o QRail is engineered for optimal structural performance.The system 0 ILL is certified to UL 2703,fully code compliant and backed by a 25-year HV Installs in seconds—no tools or hardware required warranty.QRail is available in Light,Standard and Heavy versions to match all geographic locations.QRail is compatible with virtually all STANDARD Fully Integrated Electrical Bonding SHEET NAME LIGHT modules and works on a wide range of pitched roof surfaces. Modules The QRail system provides an integrated electrical bonding path,ensuring that all exposed metal arts and DATA SHEET QRails come in two lengths— y p g g p g p p can be mounted in portrait or landscape orientation in standard or 168inches(14 ft)and 208inches(17.3 ft) the solar module frames are electrically connected.All electrical bonds are created when the components are shared-rail configurations. Mill and Black Finish installed and tightened down. SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER DS-03 Castillo Engineering DESIGNED TO PERMITV CASTILLO ENGINEERING SERVICES, LLC COA#28345 620 N.WYMORE ROAD, Solaffoot 250, SUITE MAITLAND,FL 32751 TEL:(407)289-289-2575 Top [8m m] ERMOCRATES E.CASTILLO-FL PE 52590 (4x)0.315in COPYRIGHTED BY CASTILLO ENGINEERING SERVICES,LLC / I I REVISIONS -O- - + - DESCRIPTION DATE REV 2.00in IO � .32in 0 1.50in 1.00in -O- -(@- 1.39in 4( � 50in Li 3.67in PROJECT INSTALLER .50in Scale 2:3 PES 1.83in .% GM001 S O L R R ilop, 3.17in Signature with Seal 3.67in Back Left Front Right M8-1.25 Threaded Stud PROJECT NAME [17mm] .67in 1.32in W _ 66in L) ao .32in z O) W CO 1.39in 2 � W ILL W Factory Applied FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST W z w 13� Butyl Sealant 1 INFORMATION AND CLAMP INSTALLATION INFORMATION W � PLEASE VISIT: WWW.S-5.COM W rn 3. MATERIAL: W 0 4. 6005A T61 Al METAL ROOF INNOVATIONS,LTD. Qf Ln N S� LL ® ' 8655 TABLE BUTTE RD 04 LL General Notes. EST ASSEMBLY WEIGHT: ® COLORADO SPRINGS,CO 80908 O O 1 . SolarFoot ' 0.2481bs The Right Way! 719-495-0518 � � 719-495-0045(FAX) SULIED HARDWARE: 2. M8-1 .25 Stainless Steel Hex Flange Nut (13mm Socket) S _s M8PP25HH-Fl-g.Nut TITLE s SolarFoot [CCD] 3. Metal to Metal:l /4-14 Self Drilling Screw 1-1/2" to 2-1 /2" 3 SCALE: DRAWING NO. DRAWN BY DATE Metal to Wood:l /4-14 Type 17 AB Milled Point 1 -1 /2" to 2-1 /2' 2.3 LP66-A-0-A Paul Leitch o9i2oi2o1� SHEET NAME EST.WEIGHT: 4. Example roof Bracket:0.129 Ibs S-519 PRODUCTS ARE PROTECTED BY MULTIPLE U.S.AND FOREIGN PATENTS. DATA SHEET Fastener: 0.026 Ibs VISIT OUR WEBSITE AT W W W,S-5.COM FOR COMPLETE INFORMATION ON PATENTS AND TRADEMARKS. Nut:0.015 Ibs SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-04 Castillo Engineering DESIGNED TO PERMIT^ CASTILLO ENGINEERING SERVICES, LLC COA#28345 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 COPYRIGHTED BY -'- CASTILLO ENGINEERING SERVICES,LLC ° No Tools Required REVISIONS Dvnol;l C)YN 0 B 0 N DTM DynoBondTM is pushed onto bottom DESCRIPTION DATE REV flange of module. Of SUPPORTING YOUR INVESTMENT Supports flange thicknesses from 1.2mm to 3.1 Trim Clean Wire is virtually hidden on system PROJECT INSTALLER Corrosion Resistant . PES Stainless steel clips and tin-plated copper wire paired for reduced electrochemical potential ����j; S 0 R Superior Design Signature with Seal UL recognized to 467 and 2703 12 Gauge Tin-plated Copper Stainless Steel Spring Clamp PROJECT NAME The DynoRaxx° DynoBondT`"is a proprietary UL recognized W U 00 design that allows the DynoBondT'to be used as a jumper W m between modules and rows which makes the module its J Teeth Embed into Module Frame (n W LL. frame the medium for the equipment ground path. Factory Crimped Connection W w L The DynoBond'replaces the conventional method of W W installing one ground lug per solar module and running Available Wire Lengths LU 00 121- F— a solid six gauge copper wire bonding the modules.The •8"(204mm) •76"0930mm) N [)� •12"(304 mm) •96"(2438mm) O O LL DynoBondT'"is engineered for commercial and residential •38"(965mm) applications. SHEET NAME -'- DATA SHEET C Raaff/(` 6500 Sheridan Drive,Suite 100 SHEET SIZE Dvno Buffalo NY 14221 1 SUPPORTING YOUR INVESTMENT Phone:1.866.620.24101 Toll Free Fax:1.866.807.78821,.11f , iynol,,xx E,m � ANSI 6 www.dynoraxx.com Phone:1.866.620.2410 sales(adynoraxx.com www.dynoraxx.com 111E X 17" SHEET NUMBER DS-05