Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Door Therma-Tru FIber Classic 20470.1
12/2/2020 Florida Building Code Online Professional 1 , / BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map Links Search bpr,-a a Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL20470-R2 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer J Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan 1. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL20470 R2 COI (a) Certificate of Independence.pdf Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM D638 1996 ASTM E1300 2004 ASTM E84 2000 ASTM G26 1995 ASTM G7 1997 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxkaERIWGJ93QBVWFffLiy4vjg%3d%3d 1/5 12/2/2020 Florida Building Code Online FL20470 R2 Equiv Equivalency of Standards.pdf Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Method 1 Option D 04/10/2019 04/17/2019 04/25/2019 06/18/2019 07/12/2020 Summary of Products Go to Page 0 0 0 Page 1/ 20 0 FL # Model, Number or Name Description 20470.1 a. Therma-Tru Fiber -Classic and Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (2) Inst 20470.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.1 for Design Pressure Ratings, any FL20470 R2 AE (b) Eval 20470.1.pdf additional use limitations, installation instructions and product FL20470 R2 AE (b) TT Plastics.2.pdf particulars. Created by Independent Third Party: Yes 20470.2 b. Therma-Tru Fiber -Classic and Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (2) Inst 20470.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.2 for Design Pressure Ratings, any FL20470 R2 AE (2) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.2.pdf particulars. Created by Independent Third Party: Yes 20470.3 c. Therma-Tru Fiber -Classic and Smooth -Star Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.3 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.3.pdf particulars. Created by Independent Third Party: Yes 20470.4 d. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (c) Inst 20470.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.4 for Design Pressure Ratings, any FL20470 R2 AE (2) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.4.pdf particulars. Created by Independent Third Party: Yes 20470.5 e. Therma-Tru Fiber -Classic and Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Installation Instructions FL20470 R2 II (c) Inst 20470.5.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxkaERIWGJ93QBVWFffLiy4vjg%3d%3d 2/5 12/2/2020 Florida Building Code Online Other: See INST 20470.5 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.5.pdf particulars. Created by Independent Third Party: Yes 20470.6 f. Therma-Tru Fiber -Classic and Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass Smooth -Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (c) Inst 20470.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.6 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.6.pdf particulars. Created by Independent Third Party: Yes 20470.7 g. Therma-Tru Fiber -Classic and Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass Single Smooth -Star Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.7 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.7.pdf particulars. Created by Independent Third Party: Yes 20470.8 h. Therma-Tru Fiber -Classic and Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass Single Smooth -Star Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (2) Inst 20470.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.8 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.8.pdf particulars. Created by Independent Third Party: Yes 20470.9 i. Therma-Tru Fiber -Classic and Nominal 6'8 "Impact" Glazed Composite Edge Fiberglass Smooth -Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.9.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.9 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.9.pdf particulars. Created by Independent Third Party: Yes 20470.10 j. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (c) Inst 20470.10.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.10 for Design Pressure Ratings, any FL20470 R2 AE (b) E Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.10.pdf particulars. Created by Independent Third Party: Yes 20470.11 k. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (c) Inst 20470.11.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.11 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.11.pdf particulars. Created by Independent Third Party: Yes 20470.12 I. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Impact" Glazed Composite Edge Fiberglass Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxkaERIWGJ93QBVWFffLiy4vjg%3d%3d 3/5 12/2/2020 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (c) Inst 20470.12.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.12 for Design Pressure Ratings, any FL20470 R2 AE (b) TT Plastics.2.pdf additional use limitations, installation instructions and product FL20470 R2 AE (c) Eval 20470.12.pdf particulars. Created by Independent Third Party: Yes 20470.13 m. Therma-Tru Fiber -Classic and Smooth -Star Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass Single Door with "Non -Impact" Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.13.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.13 for Design Pressure Ratings, any FL20470 R2 AE (2) Eval 20470.13.pdf additional use limitations, installation instructions and product FL20470 R2 AE (2) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.14 n. Therma-Tru Fiber -Classic and Smooth -Star Nominal 6'8 "Impact" Opaque Composite Edge Fiberglass Double Door with "Non -Impact" Sidelites (Inswing/Outswing; OXXO configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (2) Inst 20470.14.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.14 for Design Pressure Ratings, any FL20470 R2 AE (b) Eval 20470.14.pdf additional use limitations, installation instructions and product FL20470 R2 AE (b) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.15 o. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass Single Door with "Non -Impact" Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.15.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.15 for Design Pressure Ratings, any FL20470 R2 AE (b) Eval 20470.15.pdf additional use limitations, installation instructions and product FL20470 R2 AE (b) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.16 p. Therma-Tru Fiber -Classic and Smooth -Star Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 20470.16 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (For Fiber -Classic and Smooth -Star Sidelites, this product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) Nominal 8'0 "Impact" Opaque Composite Edge Fiberglass Double Door with "Non -Impact" Sidelites (Inswing/Outswing; OXXO configuration) Installation Instructions FL20470 R2 II (b) Inst 20470.16.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL20470 R2 AE (b) Eval 20470.16.pdf FL20470 R2 AE (2) TT Plastics.2.pdf Created by Independent Third Party: Yes 20470.17 q. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door (Inswing/Outswing; X configuration) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 20470.17 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Installation Instructions FL20470 R2 II (b) Inst 20470.17.pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FL20470 R2 AE (b) Eval 20470.17.pdf FL20470 R2 AE (b) TT Plastics.2.pdf Created by Independent Third Party: Yes https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxkaERIWGJ93QBVWFffLiy4vjg%3d%3d 4/5 12/2/2020 Florida Building Code Online product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.18 r. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (2) Inst 20470.18.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.18 for Design Pressure Ratings, any FL20470 R2 AE (b) Eval 20470.18.pdf additional use limitations, installation instructions and product FL20470 R2 AE (b) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.19 s. Therma-Tru Fiber -Classic and Smooth -Star Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.19.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.19 for Design Pressure Ratings, any FL20470 R2 AE (2) Eval 20470.19.pdf additional use limitations, installation instructions and product FL20470 R2 AE (2) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) 20470.20 t. Therma-Tru Fiber -Classic and Smooth -Star Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20470 R2 II (b) Inst 20470.20.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.20 for Design Pressure Ratings, any FL20470 R2 AE (b) Eval 20470.20.pdf additional use limitations, installation instructions and product FL20470 R2 AE (2) TT Plastics.2.pdf particulars. (For Fiber -Classic and Smooth -Star Sidelites, this Created by Independent Third Party: Yes product approval requires the use of "Y part numbers for these Sidelites, which have been stained or painted within six months of installation.) Go to Page 0 0 0 Page 1/ 20 0 Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: = ® ® Kid M Credit Card Safe https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp88zxkaERIWGJ93QBVWFffLiy4vjg%3d%3d 5/5 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Therma-Tru Corporation Fiber -Classic and Smooth -Star Exterior Swinging Exterior Door 118 Industrial Dr Composite Edge Opaque Fiberglass Single Door Doors Assemblies Edgerton, OH 43517 Inswing/Outswing Phone 419-298-1740 "Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Therma-Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product evaluation drawing has been developed in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ" this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This products meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-20470.1 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for the "HVHZ". 8. Outswing configurations using Coastal Sill (Item #19) and Composite Sill (Item #16) under active doors meet water infiltration requirements for "HVHZ". All other configurations do not meet the water infiltration requirements for the "HVHZ' and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 9. See drawing FL-20470.1 for size and design pressure limitations Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01461571 TAS 201, 202 & 203 (94) Testing Evaluation Lab.,lnc. William Shelton, P.E. TEL 06-1031-1 TAS 201, 202 & 203 (94) Testing Evaluation Lab.,lnc. Wendell W. Haney, P.E. TEL 01460144 TAS 201, 202 & 203 (94) Testing Evaluation Lab.,lnc. Lyndon F. Schmidt, P.E. 2. Drawing No. Prepared by Signed & Sealed by FL-20470.1 RW Building Consultants, Inc. (CA#9813) Lyndon F. Schmidt, P.E. 3. Calculations Prepared bV ,o1111111l1l,.i Signed & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) �� SC�� �iLyndon F. Schmidt, P.E. 4. Quality Assurance ,%' \;:G E N or Certificate of Participation issued by National Accreditation and �� �.� k, *% Management Institute, certifying that Therma-Tru Corporation is No 43409 manufacturing products within a quality assurance program that complies: k with ISO/IEC 17020 and Guide 53. :9 STATE OF • 0�• 4 p R. \�_ �Lyndon F. Schmidt, P.E. ��� �, FL PE No. 43409 �ii,�iO N AX ����� 8/18/2017 Sheet 1 of 1 ..V1111111i.. .• Fiber -Classic:.? & Smooth -Star, COMPOSITE EDGE INSWING/OUTSWING "iM PACT' GENERAL NOTES 1. This product evaluation drawing has been developed in compliance with the 6th Edition (2017) Florida Building Code (FBC) including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ!'this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 4. When used in areas outside of the "HVHZ" requiring wind bome debris protection, this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level " Y and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.I I. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for the "HVHZ". 8. Outswing configurations using Coastal Sill (item # 19) & Composite Sill (item # 16) under active doors meet water infiltration requirements for "HVHT'. All other configurations do not meet the water infiltration requirements for the "HVHT' and shall be installed only in non -habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. TABLE OF CONTENTS SHEET# DESCRIPTION SHEET# 1 Typical Elevations, Design Pressures & General Notes 7 Vertical Cross Sections (Thresholds) 2 Door Panel Details 8 Buck & Frame Anchoring 3 Elevations 9 Hardware Details 4 Horizontal & Vertical Cross Sections (2X Buck) 10 Components 5 Horizontal & Vertical Cross Sections (1 X Buck) 11 Bill of Materials 6 1 Horizontal & Vertical Cross Sections (Direct to Masonry) 37.75' MAX O.A. FRAME WIDTH T i (j)� '3 o ' `� Z <<Il 1{1P11 I\ N CONFIGURATION LOCK HARDWARE DESIGN PRESSURE (PSI) INSWING DESIGN PRESSURE (PSI) OUTSWING POSITIVE NEGATIVE POSITIVE NEGATIVE x Kwikset +75.0 -75.0 +80.0 -80.0 x Schlage +75.0 -75.0 +75.0 -75.0 x Multipoint +55.0 -60.0 +55.0 -55.0 See Sheet 3 for Hardware Specifications i i role. ®~ zP Cn Z U t0 U C OZ =w ��'a �t �n WOf ~ m 0 0 0 W a. U) 0) N M ro r rn o a1 °to— >(q00 n�z N Z 0 Z U O m 6 OIL 0 L m m aau- J m w v) Q o: 0 o_ z� c� o w (:) J oz tiw Q � w _j LU J LtJ U � �Ln �w Q_ U m DATE: 08/02/16 SCALE: N. T. S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 SHEET _I OF 1 1 �1 DETAIL A -A PANEL REINFORCEMENT (0.023" Thick Steel) 0.51 CIF1Y rt COMPOSITE STEEL REINFORCEMENT CAP HINGE STILE (0.023' THK.) INTERIOR (ENGINEERED WOOD) 1 HORIZONTAL CROSS SECTION 2 �001 2"0 'LLq;'. 9. STEEL REINFORCEMENT 28.86% OPEN AREA MAX. * #8 X 2.5' PFH WS (TYP. Q EACH DOOR CORNER) 35.811" MAX. DOOR PANEL WIDTH I 3 \ C- 3.6' 0.5° \ COMPOSITE LOCK STILE CAP (ENGINEERED WOOD) 0.406' f-- 0.71 COMPOSITE' CAP HINGE STILE (ENGINEERED WOOD) 35.813' MAX. DOOR _ PANEL WIDTH 4 t* Z III�III IIIIIII 40 DOOR PANEL �� DOOR PANEL 42 DOOR PANEL BOOK Hybrid Door U1 Door Vk. 111. XV At ice• �� U 11{II ,V O M 00 0 U.. ((\ o EG, z oZo 3.6- � i` o o 0 a O 0.406" NM LL m n a °I�° o 0Z Via; \ COMPOSITE STEEL REINFORCEMENT INTERIOR LOCK STILE CAP (0.023" THK.) (ENGINEERED WOOD) 2 HORIZONTAL CROSS SECTION 2 TOP RAIL (COMPOSITE/ENGINEERED / WOOD) \ INTERIOR STEEL REINFORCEMENT _- (0.023" THK.) - FOAM CORE — (POLYURETHANE - 1.9 PCF MIN.) EXTERIOR INTERIOR FIBERGLASS SKIN ` ^ (0.073" THK.) BOTTOM RAIL (COMP.) 3 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION 2 2 a co 0 0 a. DATE: 08/02/16 SCALE: N.T.S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 SHEET 2 OF 11 3 0 N 7 ..11111 tU�,. 2 ` 2 ` 2 V 5 4/ 5/ 6/ 6 4 /\ 5 /L 6 /, 6 4A5/,66 SEE HARDWARE CHART 7/\,7/ \,7A7 FIARDWARE TABLE MANUFACTURER KNOB: F51 SCHLAGE DEADBOLT: B60 KNOB: SIGNATURE SERIES KWIKSET DEADBOLT: SIGNATURE SERIES (980) HOPPE MULTIPOINT : MPDGART (THERMA-TRU) (3 pt. Manual Tongue) Fiber-Classic/Smooth-Star Door Panel Options Panel options shown are for illustration and are representative only (similar opaque panel configurations are allowed) °' '.•ito rn zF;' OY rn to t PV �> > rn 1� Z 0 0D z0 {� m 4+ U N 0 �\ N U XZQ o Ea) Z p (3n1 c O p m tL to M J O c d 0 z =o 6 U C Li Lu 0 IL DATE: 08/02/16 SCALE: N.T.S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 SHEET 3 of 11 ..,M111U,. E B C d ° .4 1 VERTICAL CROSS SECTION 4 Shown w/ 2X Buck Outswing shown (Inswing similar) 0.15' C-SINK L ) INTERIOR INT' °D d D d d D ° d D EXTERIOR EX1 a 23 24 1-1/4"MIN. L 29 40 41 42 EMB. (TYP.) 2 HORIZONTAL CROSS SECTION 4 Shown w/ 2X Buck Outswing shown (Inswing similar) 3 HORIZONTAL CROSS SECTION 4 Shown w/ 2X Buck Outswing shown (Inswing similar) 1 1 S' MIN . ♦ LLCOCn rn j'0 % E- orn to MIX .- (l�jjJ U N Z 04 c Ern z 0 �% Q tO o C W U rn It V) inJ � O 0. a: o' r CO CZ 0 CW 0 J Q. Y Um Q : C) j�C". Q� J �z m = f-m W za N� _C) O CC fY Q T AIN. DATE: 08102 16 YP.) SCALE: N.T.S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 sHEu 4 OF-1 1 r., 1-1/4" EMB. I r r.1 A 1 X Buck to be secured to masonry by others 2 HORIZONTAL CROSS SECTION Shown w/ 1 X sub -buck Outswing shown (Inswing similar) t MEMI I 0 p o 1 VERTICAL CROSS SECTION $ Shown w/ 1 X sub -buck Outswing shown (Inswing similar) G C 3 HORIZONTAL CROSS SECTION $ Shown w/ I sub -buck Outswing shown (Inswing similar) 'MIN. (TYP.) At OAF to r. lL 0) yy� I- o 0) .�I``` a 0 r �I �� � o co od t� U N�Z N Ern Z M0 C 0 pod M .. m a: a. = z° U C J''a a: o° Y Um D: o y�x^. m W i=—m W ¢ ZItJ Ncn D O =0 U O n. Q a DATE: 08/02/16 SCALE: N.T.S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 SHEET Jr' OF 111 m 0 N E 1.5" MAX. , v > v' v C 40 X 41 X 42 1 VERTICAL CROSS SECTION_ 6 Shown Direct to Masonry Outswing only w/ 4-9/16' jamb X 1 En¢ C in Z CV %romwa D 1-1/4' MIN. EMB. (TYP.) E A 2 HORIZONTAL CROSS SECTION 6 Shown Direct to Masonry Outswing only w/ 4-9/16' jamb EXTERIOR 1 DIRECT TO MASONRY MAX. DESIGN PRESSURE: w/ STANDARD STRIKE _ ± 55 PSF w/ SECURITY STRIKE = ± 65 PSF N N 1-1/4"MIN. EMB. (TYP.) a E 3 HORIZONTAL CROSS SECTION 6 Shown Direct to Masonry Outswing only w/ 4-9/16' jamb Q �::E E 1.5„ . _ v MAX. c v > v 10 40 X41 X42 EXTERIOR INTERIOR 4 VERTICAL CROSS SECTION 6 Shown Direct to Masonry Outswing only w/ 6-9/16' jamb LIVID. I 1 I F.) 5 HORIZONTAL CROSS SECTION 6 Shown Direct to Masonry Outswing only w/ 6-9/16' jamb 0 L. = X i C. W �•.� ♦ O Q7 '''/// AoJ CI t0 OD It fill, � m U N z 0xza v N EO z Zm U a O no c W Ea. UM 50 =a maa� �u- 0 w o 3 a: �z Qo U,Q y0 Qtn J J'dU Q� m i_ 1z Q N to 0:: z D _rz H- o 1- a U 0-- M, U l -1 /4" MIN. DATE 08/02/16 EMB. (TYP.) SCALE: N.T.S. 6 HORIZONTAL CROSS SECTION DwG. BY: JK 6 Shown Direct to Masonry CHK. BY: LFS Outswing only w/ 6-9/16' jamb DRAWING NO.: FL-20470.1 sHEEr 6 of 11 .��Iillitr,. 1W Notes: 1. Sill Item #'s 17, 18, 19, 32, 34, 35, 36, 37, 38 & 39 are attached to jambs w/ (3) #8 X 2-1 /2" pfh screws at each end. Sill Item #'s 16 & 33 are attached to jambs w/ (2) #8 X 2-1 /2" pfh screws at each end. Sill Item # 15 is attached to jambs utilizing (2) # 10 X 2" pph SMS at each end. INTERIOR EXTERIOR INTERIOR EXTERIOR :40)(41 42 8 40 41 42 9 32 38 39 33 34 35 3b 37 SEE NOTE 1 E SEE NOTE\ MmM19 SEE NOTE 1 p p 1 VERTICAL CROSS SECTION 7 Inswing Sill 7 16117118119 E D _ 3 VERTICAL CROSS SECTION 7 _j Outswing Sill (Coastal Sill Shown) D p 2 VERTICAL CROSS SECTION 7 Inswing Sill EXTERIOR 40 41 42 Mgff•lta p, p u p n e J 4 VERTICAL CROSS SECTION 7 j Public Access Sill eta• � -•/ Xt to, L /i1111 O M o0 z0 41 0 :20 XZU ¢ C 0 O m m o Uy J C W a` �M p=a .. a m a. a. m c Z .. 0 CW 0 3'a J �O �O �N F--O Cif LC Uj U Z V �.z ~LID Q %0 U � � O W 0 M a Q a W a CD n a DATE: 08102/16 SCALE: N.T.S. DWG. BY: JK CHK. BY: LFS DRAWING NO.: FL-20470.1 SHEET 7 OF 11 2X BUCK 4" (TYP.) I C� u HEAD & JAMBS (TYP.) bQ PSF MAX MASONRY (TYP.) 2X BUCK ANCHORING 4" (TYP.) U HEAD & JAMBS (TYP.) .1 . 2X BUCK ANCHORING �8 x 2-1 /2' PFH WS JAMB TO HEAD DETAIL (TYP.) r O a IN 2X BUCK 1 X BUCK BUCKDIRECT TO MASONRY FRAME HEAD & JAMBS (TYP.) V Z cr C) C V CJ Q (n g uj �m _es W U.:~m a o 0 °Z o= a. a DATE: 08/02/16 SCALE: N.T.S. DWG. BY: JK Q CHK. BY: LFS 3 DRAWING NO.: D FL-20470.1 c SHEET 8 OF 11 `Xt / .. ar� kI � L• 1r� � to 4u- i3 d v H 'rco :2i co/. N• .7 Z � KN•.. O—Z J n co 28 in /// 2X BUCK N G N /j���U11• tt�` z o 0 SEE HINGE 1 X BUCK G DETAIL (TYP.) ` m O N .: Z DIRECT TO M D 26 v P E o) z m Z U (� ° �o o m MASONRY 0°c CL m r U. m aaa • c CZ 2X BUCK 25 �� E o 1 X BUCK O SEE TONGUE o c n3 G 27 +1 0- 0O a STRIKE DETAIL +� 2X BUCK L o v a DIRECT TO M o0 -- o -- (TYP.) N MASONRY _ v CD N O � cn 1 X BUCK G `V O `�' DIRECT TO LATCH & DEADBOLT DETAIL "' `O = `�' M Q 31 0 Kwikset ® �� MASONRY �o • Q� i Ir SEE LATCH TONGUE STRIKE DETAIL m o` 2X BUCK L & DEADBOLT IL SEE LATCH t Mu 37pom oc =W w o 1 X BUCK G & DEADBOLT m v) 8 Ci Q Q DETAIL 0 _ N = O MASONRY DIRECT TO M SUB STRIKE 0Q PLATE 28 2X BUCK L ' m $ 1 X BUCK G (� 22 STRIKE JAMB HINGE JAMB STRIKE JAMB DIRECT TO M (� Latch and Deadbolt Multipoint Lock MASONRY N 2X BUCK 25 30 V) w o I BUCK G p 27 = � DIRECT TO M `~° � MASONRY L 2X BUCK LATCH & DEADBOLT DETAIL 24 Mu tipoinLock k LATCH & DEADSOLT DETAIL 8B G 1 X BUCK a011 U Schlage M DIRECT TO = ? MASONRY MULTIPOINT LOCK STRIKE DETAILS LATCH & DEADBOLT STRIKE DETAILS " w Z DIRECT TO ® �- Q (Standard Deadbolt Strike Plate) M MASONRY 24 23 ^ 3 �0 Z n 0 L DAm- 08/02/16 L' sue: N.T.S. DEADBOLT STRIKE DETAILS HINGE DETAIL DWG. BY. X(Security Deadbolt Strike Plate) CHK. BY: LFS 3 DRAWING NO.: FL-20470.1 a SHEET 9 OF 11 N L-Jou 7.59" 7.5' LO--'— LO 01 CV 32 INSWING THRESHOLD Inswing Basic Composite Adjustable Sill 7-1 /2" 4.56" ,'fin r 33 INSWING THRESHOLD Inswing Basic Foxed Sill 5.75' 34 INSWING THRESHOLD Inswing Moderate Climate Sill 1-3/8 35 INSWING THRESHOLD Inswing Moderate Climate Sill 5.75" _LO,a- 3b INSWING THRESHOLD Inswing Basic Foxed 5 3/4"Sill 37 INSWING THRESHOLD Inswing Basic Fixed 7-1 /2" Sill 38 INSWING THRESHOLD Inswing Composite Adjustable Sill 39 INSWING THRESHOLD Inswing Basic Composite Adjustable Sill N Co O C� 15 PUBLIC ACCESS THRESHOLD (--1.79" -- I LO 0 8 SWEEP 0 9 SWEEP Lq C3 " P2.06- i0 o *iw9t N 4.56" ^ ag e _ ta: Nt o P1 F— 2.36" —i 11111% WOOD JAMB 1 16 OUTSWING THRESHOLD Composite Sill MAX. +55 PSF (where water infiltration is required) 4.56' UOUTSWING THRESHOLD 17 Composite / Aluminum Sill 1 OUTSWING THRESHOLD Composite / Aluminum Sill (Thermal Break) 14 COASTAL OUTSWING THRESHOLD Wood / Aluminum Sill L ALtto C : a° D41:`Q- • yy orn ZQ ,V I0 M p(j 0 z aoo 0 U N •: Z Kp Z o t0 Z raj' °o NM 0m d ? 0 a. X m a: a. LL ® c z o cw a 3`a a J m M w V) O a< 0 a Z) F08102116 LIE: N.T.S. BY: JK BY. LFS WING NO.: FL-20470.1 ET 10OF11 ..11111 / U1.. BILL OF MATERIALS BILL OF MATERIALS ITEM # DESCRIPTION MATERIAL ITEM # DESCRIPTION MATERIAL A 1 X BUCK (SG >= 0.42) WOOD 25 #8 x 2-1 /2" PFH WOOD SCREW STEEL B 2X BUCK (SG >= 0.42) WOOD 26 #8 x 5/8" PFH WOOD SCREW STEEL C 1 /4" MAX. SHIM SPACE - 27 LATCH STRIKE PLATE STEEL D 1 /4' X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE STEEL E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 28A DEADBOLT SECURITY SUB STRIKE PLATE STEEL 28B DEADBOLT STRIKE PLATE (SECURITY) STEEL G 3/16" X 3-1/4" ITW CONCRETE SCREW STEEL 29 4" X 4' HINGE STEEL J 1 /4' X 3-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 30 LATCH & DEADBOLT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP L # 10 X 2-1 /2" PFH WOOD SCREW (1.15" MIN. EMBEDMENT) STEEL 31 MULTIPOINT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP M 3/16" X 2-1 /4" ITW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP N 3/16" X 2-3/4' ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP 1 JAMB (FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP (MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 7 WEATHERSTRIP (LONG REACH) FOAM 36 INSWING THRESHOLD ALUM/COMP 8 SWEEP VINYL 37 INSWING THRESHOLD ALUM/COMP 9 SWEEP (USE W/ MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP 10 SWEEP (USE W/ PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL (BOOK) - 16 OUTSWING THRESHOLD ALUM/COMP 41 DOOR PANEL (HYBRID) - 17 OUTSWING THRESHOLD ALUM/COMP 42 DOOR PANEL (U 1) - 18 OUTSWING THRESHOLD ALUM/COMP 19 COASTAL OUTSWING THRESHOLD ALUM/WOOD 22 #8 x 3/4' PFH WOOD SCREW STEEL 23 # 10 x 3/4" PFH WOOD SCREW STEEL 24 #10 x 1" PFH WOOD SCREW STEEL a = gt V dY c z I rr n 4 CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ANCHOR. ANCHOR MIN;.:,MIN.;CLEARANCf _ MIN. CLEARANCE TYi'E SIZE EMBEDME/�IT; TO MASONRY TOA©JACENT fDGEk ANCHOR ITW ® 1/4" 1-1/4" 2" 4" TAPCON ELCO ® 1/4" 1-1/4" 1" 4" ULTRACON ITW ® 3/16" 1-1/4" AS SHOWN 1-1/2" TAPCON WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 518" edge distance, I"end distance, & I" o.c. spacing of wood screws to prevent the splitting of wood. • V /� rr 02 Se 3j M �4r: O—Z L� 1 'Sys � orn ` � M co CD U NZ v v z X4 o E os z m° a O U*0 9 C W N� O oa It m a a °a° a �z U [ 41 pa's DATE: 08/02/16 SCALE: N.T.S. DWG, BY: JK CHK, BY: LFS DRAWING NO.: FL-20470.1 R W Building Consultants, Inc. Consulting and Engineering Services for the Building Industry P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Manufacturer Plastic Materials Testing Therma-Tru Corporation Polyurethane Foam Core 118 Industrial Drive Fiberglass Door Skin (SMC) Edgerton, OH 43517 Lite Frames (SMC, BTS, PVC) Phone 419.298.1740 Scope: Plastics testing performed for Therma-Tru Corporation: Material Test Report No. Test Standard Polyurethane Foam Core ATI 67508.01-106-18 ASTM D 1929-96 Polyurethane Foam Core 15427-107362 ASTM E 84-00a Fiberglass Door Skin (SMC) TEL 01460336-A ASTM D 635-03 TEL 01460336-B ASTM D 1929-96 TEL 01460336-C ASTM D 2843-99 BTS Lite Frame TEL 01460337-A ASTM D 635-03 TEL 01460337-B ASTM D 1929-96 TEL 01460337-C ASTM D 2843-99 SMC Lite Frame TEL 01460338-A ASTM D 635-03 TEL 01460338-B ASTM D 1929-96 TEL 01460338-C ASTM D 2843-99 PVC Lite Frame TEL 01460339-A ASTM D 635-03 TEL 01460339-B ASTM D 1929-96 TEL 01460339-C ASTM D 2843-99 Exposed Plastics ETC-01-741-11075.0 ASTM D 638-96 (BTS, SMC, PVC) ETC-01-741-11076.2 ASTM D 638-96 ETC-01-741-10921.0 ASTM D 638-96 STTS00001 ASTM G 26-95 STTS 99-0513.01 ASTM G 7-97 (5 yr. exposure) Testing Laboratory Signed by Architectural Testing Lab. Joseph A. Reed, P.E. Omega Point Lab. John W. Dougherty, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Lyndon F. Schmidt, P.E. Testing Evaluation Lab. Testing Evaluation Lab. Testing Evaluation Lab. ETC Laboratories, Inc. ETC Laboratories, Inc. ETC Laboratories, Inc. Sub -Tropical Testing Sub -Tropical Testing Equivalency of Standards Test Standards Used 6th Edition (2017) FBC Referenced Standards ASTM D 635-03 ASTM D 635-10 ASTM D 638-96 ASTM D 638-03 ASTM D 1929-96 ASTM D 1929-12 ASTM D 2843-99 ASTM D 2843-10 ASTM E 84-00a ASTM E 84-13a ASTM G 26-95 ASTM G 155-05a Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. Lyndon F. Schmidt, P.E. Joseph L. Doldon, P.E. Joseph L. Doldon, P.E. Joseph L_ Doldon, P.E. Lon Hicks, V.P. Lon Hicks, V.P. The products referenced above have been tested to the standards listed. It has been determined by Lyndon F. Schmidt, P.E. and RW Building Consultants, Inc. that the tested standards are equivalent to the referenced test standards as adopted by the 6th Edition (2017) Florida Building Code. O Iv0SUTE OF P �o goo Lyndon F. Schmidt, P.E. o 0(�'e,.o� ©Q' o ,�'®oo FL PE No. 43409 Sheet 1 of 1 19, 8/16/2017 Q •� �00 ''�°r-66