Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
jb_349292_00___acad_b_01, vincinity map, plans
INDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS **** **** **** **** LICENSE GENERAL NOTES 2' FSB 2' FSB2' FS B 2' FSB2' FSB 2' FS B 2' FSB2' FSB2' FSB 2' FS B2' FSBPitch6/12MP1Pitch 6/12 MP2Pitch6/12MP3 Scale:1/16" = 1' SITE PLAN 01'32'16' LEGEND MP3 23 153 23 153 Comp Shingle 1 Story MP2 23 243 23 243 Comp Shingle 1 Story MP1 23 63 23 63 Comp Shingle 1 Story #SSTAMPFL #ESTAMPFL NTS TYPICAL PV SIDE VIEWSV Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPFL #SSTAMPFL LICENSEMODULE SPECS INV 1 INVERTER SPECSGENERAL NOTESMAIN PANEL SPECSGROUND SPECS INV 2 INV 3 AC DC N A B EGC GEC L2 L1 N EGC/ GEC GND N 240V Inverter 1 IND EGC DC- DC+ DC- DC+ DC- DC+ A DC- DC+ EGC DC- DC+ EGC DC- DC+ MP 1: 1x9 MP 3: 1x9 MP 2: 1x6 GD A PV POI 1 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC3 4 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC4 5 Vmp = VAC Imp= AAC 5 #ESTAMPFL LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set Solar Inverter for North America Single Phase Solar Inverter for North America M4-TL-US | M5-TL-US | M6-TL-US | M8-TL-US | M10-TL-US | M10-4-TL-US Key Features: x Smart inverter with BLE, optional WiFi, Ethernet, 3G / 4G cellular communication x Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) x Support bi-directional cloud communication x Support remote diagnosis and OTA x Type 4 protection x Built-in AFCI & Rapid shutdown controller x CEC efficiency 97.5% x UL 1741 SA, HECO compliant x CA Rule 21 Phase 1 & 2 & 3 compliant Solar Inverter for North America Rev 14 - 02/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US INPUT (DC) Max. system voltage 600 V Nominal voltage 380 V Max. operating voltage 540 V Operating MPPT voltage range 50 V to 480 V Max. input current per MPPT 12 A 12 A 12 A 12 A 20 A 10 A Max. short circuit current per MPPT 15 A 15 A 15 A 15 A 30 A 15 A Max. DC/AC ratio 1.3 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2 - 2 2 - 2 2 - 2 - 2 2 - 2 - 2 2 - 2 2 - 2 - 2 - 2 OUTPUT (AC) Nominal output power @ 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max. output power @ 240Vac 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W Nominal output power @ 208Vac 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W Max. output power @ 208Vac 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max. continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating frequency 60 Hz Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption < 1.5 W 1) THD @ nominal power < 3 % Power factor @ nominal power > 0.99 Adjustable power factor range 0.85i to 0.85c GENERAL SPECIFICATION Max. efficiency 98% CEC efficiency 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V Operating temperature range -22 °F to 149 °F (-30 °C to 65 °C) with derating above 113 °F (45 °C) Storage temperature range -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Max. operating altitude 9,843 ft (3,000 m) Acoustic noise < 45 dB(A) @ 3 ft (1m) Solar Inverter for North America Rev 14 - 02/2020 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US MECHANICAL DESIGN Dimensions (W x H x D) 16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Display LED indicators Weight 2) 41.9 lbs (19.0 kg) 41.9 lbs (19.0 kg) 44.3 lbs (20.1 kg) 45.2 lbs (20.5 kg) 47.6 lbs (21.6 kg) 47.6 lbs (21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Rapid Shutdown Initiation Method Loss of AC or DC Disconnect Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Enclosure material Die-casting aluminum STANDARDS Enclosure protection rating Type 4 Safety UL 1741, CSA-C22.2 No. 107.1-01 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547, IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2017 Article 690.11 Rapid shutdown protection NEC 2017 690.12 3) Integrated meter ANSI C12.20, Class 0.5 Grid support regulation UL 1741 SA, California Rule 21 phase 1 & 2 & 3, HECO Compliant WARRANTY Standard warranty 10 years 1) Without consumption of communication card 2) Without weight of revenue grade meter 3) Compliant with Tigo rapid shutdown system or APS rapid shutdown system Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 6am to 6pm PST (apart from Holidays) www.Delta-Americas.com Residential Energy Storage Solution for North America Rev 05 – 09/2019 © Copyright 2018 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Accessory: MCI (Middle Circuit Interrupter) Features: z Automatic function test upon startup, ensure safety z Enclosure protection Type 4 z Meet 2017 NEC Article 690.12 Rapid Shutdown z No installation needed for every PV Module, make better cost performance for PV system z With PLC, no additional cable needed INPUT RATINGS Delta part number GPI00010110 GPI00010114 Maximum system voltage 600 Vdc Rated input operating voltage 6 Vdc to 80 Vdc Number of input circuit 1 Startup voltage 22 V Rated input current 12 A OUTPUT RATINGS Rated output current 12 A Control signal method PLC signal GENERAL DATA Dimensions (W x H x D) 4.6 x 6.5 x 3.0 in (117 x 165 x 76.5 mm) (without cable) 3.8 x 6.5 x 1.1 in (97.3 x 165 x 27.3 mm) (without cable) Weight 2.0 lbs (0.9 kg) 1.4 lbs (0.64 kg) Bracket Groove adapter bracket Without Cooling Natural convection DC input / output connectors MC4 PV connector Cable length with connector Input : 5.9 in (150 mm) Output: 47.2 in(1200 mm) Input : 5.9 in (150 mm) Output : 12 in (305 mm) Enclosure material Plastic Operating temperature -40 °F to 185 °F (-40 °C to 85 °C) Storage temperature -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level Self power consumption <3.0 W Warranty 10 years STANDARD COMPLIANCE Enclosure protection rating Type 4 / IP67 Safety UL 1741, CSA C22.2 No. 330-17 Rapid shutdown NEC 2017 Article 690.12 EMC FCC Part 15 Class B YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY (ALT) Product and Performance Warranty Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. ZEP COMPATIBLETM FRAME DESIGN High-tech black Zep CompatibleTM frame, for improved aesthetics, easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and industrial buildings Q.PEAK DUO BLK-G6+ / SC 330-345 ENDURING HIGH PERFORMANCE Į [% / K] + 0.04 ȕ [% / K] − 0.27 Ȗ [% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) 330 335 340 345 [W] 330 335 340 345 [A] 10.41 10.47 10.52 10.58 [V] 40.15 40.41 40.66 40.92 [A] 9.91 9.97 10.02 10.07 [V] 33.29 33.62 33.94 34.25 [%] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W] 247.0 250.7 254.5 258.2 [A] 8.39 8.43 8.48 8.52 [V] 37.86 38.10 38.34 38.59 [A] 7.80 7.84 7.89 7.93 [V] 31.66 31.97 32.27 32.57 [V] 1000 (IEC) / 1000 (UL)II [A DC] 20 C (IEC) / TYPE 2 (UL) [lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa) − 40 °F up to + 185 °F (− 40 °C up to + 85 °C)[lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa) 3 See Installation Manual Certified UL 1703 (254141) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Format 68.5 × 40.6 × 1.57 in (including frame) (1740 × 1030 × 40 mm) Weight 47.4 lbs (21.5 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+/SC_330-345_2019-11_Rev01_NAELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1 Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Protection Class Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703 Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull (UL)3 QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²]RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 1552520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 37.4" (950 mm) 68.5" (1740 mm) 4 × Fastening points (DETAIL A) Frame 6.06" (154 mm) 40.55" (1030 mm) 38.6" (981 mm) 1.57" (40 mm) 8 × Drainage opening 0.14" × 3.1" (3.6 mm × 8 mm) 6 × Grounding points ø 0.16" (4 mm) Label DETAIL A 0,472" (12 mm) 0.354" (9 mm)1.063" (27 mm) 15.6“ (395 mm) 7.09" (180 mm) 4 × Drainage opening ≥ 43.3" (11 00 m m) ≥ 43. 3" (11 00 m m) DC- DC+ 1 GD · · · · · DC1 HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU ¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP IRUFRPSRVLWLRQVKLQJOHURRIV DQ\PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ 6SHFL¿FDWLRQV HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\ UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP 1H[W/HYHO390RXQWLQJ7HFKQRORJ\ ]HSVRODUFRP 3DUW1R /LVWHGWR8/ &DSWXUHG:DVKHU/DJ 3DUW1R )ODVKLQJ,QVHUW 3DUW1R /LVWHGWR8/ $UUD\6NLUW 3DUW1RRU /LVWHGWR8/ 3DUW1RRU /LVWHGWR8/ (QG&DS 3DUW1R /RU 5RU '&:LUH&OLS 3DUW1R /LVWHGWR8/ *URXQG=HS9 3DUW1R /LVWHGWR8/DQG8/ ,QWHUORFN 3DUW1RRU /LVWHGWR8/ /HYHOLQJ)RRW 3DUW1R /LVWHGWR8/