Loading...
HomeMy WebLinkAboutProduct Approval 11118/2020 Florida Building Code Online Ur�ed (c*Yw. Business & - 9ulation =kA rc SCIS Home Log In I Uscr P g,strabon Hot Topics Submit Surcharge i Stats&Facts Publications Contact Us aCIS Site Map j Links f Search d r 4-1Product Approval USER 'dblic User RECEIVED Product A'Nroval Menu>Prodod or Agpllcation Search>Atiol'ca[on List>Application Detail ZULQ NOV 18 FL# FL5259-R30 Application Type Revision permitting Department Code Version 2017 St.Lucie County Application Status Approved Comments Archived f _ - Fill . Product Manufacturer POLVGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@polyglass.com 2� Authorized Signature Maury Alpert malpert@polyglass.com -661 Technical Representative TECH REP 1 Address/Phone/Email 1111 West Newport Center Drive RE��E �pL pN Deerfield Beach,FL 33442 �+ -` (866)802 8017 D`i 0 ^Ov`- uspolyglasstechnlcal@polyglass� r . V Quality Assurance Representative QA REP S."t` a BOC'G Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 FIL I X 71Y uspolyglasstechnical@polyglass.com FILL Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R30 COI 2020 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM 01970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 hftps://floridabuilding.org/pr/pr_app_dtl.aspx7param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01iplayHJQ%2bBzcAJSsDg3APdrQ%3d%3d 1/2 f 11/18/2020 Florida Building Code Online FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/06/2020 Date Validated 07/14/2020 Date Pending FBC Approval 07/20/2020 Date Approved 10/13/2020 Date Revised 10/22/2020 Summary of Products FL X Model,Number or Description Name 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL5259 R30 II 2020 07 06 FINAL ER POLYGLASS UNDERLAYMENTS FL52S9- Approved for use outside HVHZ:Yes $3Q,g.Iff Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular FL5259 R30 AE 2020 07 06 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- underlayment system (over concrete deck) R30.Ddf for use under foam-on tile systems(where Created by Independent Third Party: Yes the underlayment forms part of the load- path). Refer to ER Section 5.6.1 for other systems,other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Qpyrlght 2007-2013 State of Florida,::Privacy Statement::AccessibilM Statement::Refund Statement Under Florida law,email addresses arc public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity,instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.•Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click br€. Product Approval Accepts: ®® ® Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01ipi ayHJQ%2bBzcAlSsDg3APdrQ%3d%3d 2/2 NEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-R26 1111 West Newport Center Drive FL5259-R30 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954)233-1230 Revision 26: 07/06/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017)Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO(etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 16. Prepared by: f Robert J.M. Nieminen, P.E. . :__,Sa3;•} .,,.• Florida Registration No.59166, Florida DCA ANE1983 "�-h�••m.•"" The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 07/06/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOletc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 60 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prove Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2012 1507.2.3/1507.1.1 Material standard ASTM D226 2009 1507.2.4/1507.1.1,1507.2.9.2 Material standard ASTM D1970 2015 1507.3.3 Material standard FRSA/TRI April 2012 2012 1507.11.2 Material standard ASTM D6163 2008 1507.11.2 Material standard ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 1507.11.2 Material standard ASTM D6509 2009 TA5110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entltv Examination Reference Date EM�tI ( Examination Reference Date ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) ASTM D1970 PLYG-SC30130.06.16-1 06/27/2016 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) Tensile adhesion PLYG-SC30130.06.16-2 06/27/2016 ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016 ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 ERD(TST 6049) ASTM D3970/D4798 PLYG-SC8080.07.16 07/16/2016 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 ERD(TST 6049) TAS 103 PLYG.SC33040.12.16 12/27/2016 ERD(TST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 ERD(TST 6049) 30/90 physicals PLYG-SC31900.03.17 03/10/2017 ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD(TST 6049) TA5 103 PLYG-SC12115.08.17 08/08/2017 ERD(TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 ERD(TST 6049) TA5 103 PLYG-SC33035.08.17 10/31/2017 ERD(TST 6049) ASTM D1970 P33360.06.10 D6/25/2010 FM(TST 1867) Wind Uplift 3004091 01/12/2000 ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019 ERD(TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 M-D(CER 1592) HVHZ Compliance NOA 17-0614.22 07/06/2017 ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 MTI(TST 2508) ASTM D4798 1X20H7A G4/01/2008 ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 NEMO(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018 ERD(TST 6049) Tensile Adhesion P40390.08.12-2 08/07/2012 NEMO(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019 ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMO(TST 6049) ASTM D6163 45-PLYG-18-002.01.19-A 01/24/2019 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-D02.05.19-C 05/20/2019 ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST 6049) ASTM D1970 4j-PLYG-I9-SSUDL-00.A 09/10/2019 ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEMO(TST 6049) TA5103 4S-PLYG-18-OD4.10.19-G 10/08/2019 ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 NEMO(TST 6D49) TA5103 4S-PLYG-18-004.10.19.1 10/08/2019 ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/09/2019 ERD(TST 6049) ASTM D6509 P37590.03.13-1-R1 06/26/2013 NEMD(TST 6D491 TA5103 41-PLYG.19-SSUDL-01.A 10/10/2019 ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO ITST 6049) TA5103 4j-PLYG.19-SSUDL-02.A 01/02/2020 ERD(TST 6049) ASTM 04601 P45940.09.13 09/04/2013 NEMO TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.H 01/14/2020 ERD(TST 6049) Wind Uplift P11751.05.03-R1 . 11/26/2013 NEMO TST 6049) ASTM 01970 4S-PLYG-18-004.01.20.K 01/14/2020 ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 NEMO TST 6049) TAS103 4j-PLYG-20-SSUDL-01 07/06/2020 ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 PRI(TST 5878) Tensile Adhesion PRIO1111 04/08/2002 ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 PRI(TST 5878) TAS 103 PUSA-019-02-01 07/14/2003 ERD(TST 6049) Tensile adhesion 6020.09.14-6 09/08/2014 PRI(TST 5878) TAS 103 PUSA-035-02-01 09/29/20D6 ERD(TST 6949) Tensile adhesion P46520.10.14 10/03/2014 PRI(TST 5878) TA5 103 PUSA-055-02-02 12/10/2007 ERD(TST 6049) ASTM D1970/04799 P43290.10.14 10/17/2014 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/28/2008 NEMO ETC,LLC. Evaluation Report P32060.02.09-R26 Certificate of Authorization#32455 9"EDITION(2017)FBC NON.HVIfZ EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 2 of 16 ONEMO I etc. Entity flwMnation Ralerence Date Entling Examination Reference Date ERD(TST 6049) TA5103 PLVG-SC7S50.03.15 03/24/2015 PRI(TST 5878) ASTM D6164 PUSA-088-02-01 07/29/2009 ERD(TST 6049) Tensile adhesion P40390.04.15 04/03/2015 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008 ERD(TST 6049) TA6103 P44360.10.14-RI 05/18/2015 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011 ERD(TST 6049) Wind Uplift PLVG-SC8905.05.16-1 05/17/2016 UL(QUA9625) Quality Control Service Confirmation 09/13/2018 4. PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet 4.3 Elastoflex S6 G ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.4 Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet FRSA/TRI April 2012 4.5 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.6 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.7 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt TAS 103 waterproofing membrane,fiberglass reinforced,with a FRSA/TRI April 2012 polyester fabric surface 4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet (FR) FRSA/TRI April 2012 4.9 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied "Cap Sheet"in the "Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened or adhered tile roof systems 4.10 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/TRI April 2012 use as an alternate to Heat Applied"Cap Sheet"in the 'Two Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems 4.11 Polyflex SA P ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.12 Polyflex SA P FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI April 2012 4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet 4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced, asphaltic base sheet 4.15 Polystick IR-Xe ASTM D1970 FL, PA Nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface 4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 PA,TX membrane,glass fiber reinforced,surfaced with FRSA/TRI April 2012 polyolefinic film surface NEMO ETC,U.C. Evaluation Report P32060.02.09-R26 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL52SS-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 3 of 16 ONEMOletc. 4. PRODUCT DESCRIPTION: Product Specification Plant(s) Description 4.17 Polystick MU-X ASTM D1970 FL,NV, PA Nominal 54-mil thick dual-layer rubberized asphalt (See Section 5.8) waterproofing membrane,fiberglass reinforced,with a polypropylene film surface 4.18 Polystick TU Max ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing TAS 103 membrane with a 190 g/m2 polyester fabric surface FRSA/TRI April 2012 4.19 Polystick TU P TA5103 TX Nominal 130-mil thick rubberized asphalt waterproofing FRSA/TRI April 2012 membrane,glass-fiber/polyester reinforced,with a granular surface 4.20 Polystick TU Plus ASTM D1970 FL, PA Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane,glass fiber reinforced,with a polyester fabric FRSA/TRI April 2012 surface 4.21 Polystick XFR ASTM D1970 NV Nominal 80-mil thick rubberized asphalt waterproofing TAS 103 membrane,glass fiber reinforced,surfaced with a FRSA/TRI April 2012 textured film surface S. UmrrATIONs: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-Dade Counties). 5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. S.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt Clay and Concrete Tile Metal Slate Wood /2507.3J Underlayment Shingles shingles (15072) Mechanical Adhesive-Set Panels Shingles (15077) Shingles Shakes Attach (150Z4) (1507.5) (1507.8) (350Z9) Yes Yes Elastobase Yes (Base Sheet In 2-ply (Base Sheet In 2-ply Yes Yes Yes No No system) system) Yes Yes ElastobaseP Yes (Base Sheet In 2-ply (Base Sheet in 2-ply Yes Yes Yes No No system) system) Yes Yes Polyglass Base No (Base Sheet In 2-ply (Base Sheet In 2-ply No No No No No system) system) Yes Yes Polyglass G2 Base No (Base Sheet in 2-ply (Base sheet in 2-ply No No No No No system) system) Yes Elastoflex S6 G Yes Yes (See 55.1) No No Yes No No Elastoflex S6 G FR yes Yes No No No Yes No No HydraGuard Dual Pro Yes No No Yes Yes Yes Yes Yes NEMO ETC,U.C. Evaluation Report P32060.02.09-R26 Certificate of Authorization#31455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1130 Polyglass Roof Underlayments;(954)233.1230 Revision 26:07/06/2020 Page 4 of 16 ONEMOjetc. TABLE 1: ROOF COVER OPTIONS Asphalt nay and Concrete Tile Metal Slate Wood Underlayment Shingles pb07�1 Mechanical(3W7.3)Adhesive-Set Panels Shingles (25077)Shingles Shingles Shakes Attach p50Z41 pwzsl (lsoza) (ls07.9) HydraGuard Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Yes Yes Mule-Hide SA-APP Cap Sheet Yes Yes Yes No No Yes No No (See 5.5.1) Mule-Hide SA-APP Cap Sheet(FR) Yes Yes (See es No No Yes No No 5.PolyRexG Yes Yes Ves No No Yes No No (See 5.5.1) PolyflexG FR Yes Yes No No No Yes No No Polyflex SA P Yes Yes (See es No No Yes No No S.Polyflex SA P FR Yes Yes (See es No No Yes No No 5.Polystick IR-Xe Yes No J5.5.11) No No Yes Yes Yes Polystick MTS Plus Yes Yes Yes Yes Yes Yes Yes Polystick MU-X Yes No Yes Yes Yes Yes Yes Polystick TU Max No Yes Yes Yes No Yes Yes !(SeePolystick TUP No Ves No No No Yes Yes Polystick TU Plus yes Ves Yes Yes Yes Yes Yes (See 5.5.1) Polystick XFR Yes Yes No Yes Yes Yes Yes Yes 5.5.1 "Adhesive-set Tile"is limited to use of the following Approved tile adhesives/underlayment combinations. TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINAT10N51 Florida Product Adhesive Approval Underiayments DAP Foam'Touch'n Seal StormBond FL14506 Polystick TU Max or Polystick TU Plus Roof Tile Adhesive" Dupont"TILE BOND'"Roof Tile FL22525 HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Adhesive" Polystick TU Plus ICP Adhesives and Sealants"Polyset• Elastoflex 56 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule- AH-160" FL6332 Hide SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus Adhesives and Sealants"Polyset• Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule- ICP Ad ICP Ad FL6276 Hide SA-APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEW ETC,LLC. Evaluation Report P12060.02.09-R26 Certificate of Authorization p32455 6"EDITION(2017)FBC NON-HVHI EVALUATION FLS2S9-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 5 of 16 ONEMOletc. 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIAYMENTS Underlayment Application Substrates(designed to meet wind loads for project) Type Primer Material(s) Deck/ (Optional)ASTM D41 plywood,OSB,Southern Yellow Pine or Huber HydraGuard Dual Pro, Engineered Woods"ZIP System"Panels HydraGuard Tile Pro, sheathing ASTM D41 structural concrete Polystick(all variations), self- ASTM C1289 Type II Class 1 polyisocyanurate,ASTM Mule-Hide SA-APP Cap adhering Insulation (Optional)ASTM D41 C1289 Type V polyisocyanurate-composite,DensDeck Sheet,Mule-Hide SA-APP or WB-3000 Cap Sheet(FR),Polyflex Prime or SECUROCK Gypsum-Fiber Roof Board SA P or Polyflex SA P FR Base N/A ASTM D226 felt,Elastobase,Elastobase P or Mule-Hide Sheet Nail Base Deck ASTM D41 structural concrete Elastoflex 56 G or hot asphalt Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Elastoflex S6 G FR Base N/A ASTM 0226 felt,Elastobase,Elastobase P,Mule-Hide Nail Sheet Base or Polyglass G2 Base Deck ASTM D41 structural concrete Polyflex G or Polyflex G FR torch- Insulation (Optional)ASTM D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board applied Base Elastobase,Elastobase P,Mule-Hide Nail Base,Polyglass Sheet N/A G2 Base or Polyglass Base 5.6.1 Wind Resistance for Underlayment Systems in Adhesive-set Tile Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive-set or mortar-set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-52.5 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min.4-inch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #2 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #3 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y.."ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. NEMO ETC,U.C. Evaluation Report P12060.02.09-R26 Certjcate of Authorization#32455 6TH EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R30 Polyglass Roof Underlayments;(9541233-1230 Revision 26:07/06/2020 Page 6 of 16 N NEnno I etc. #4 Maximum Design Pressure=-105 DO: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-135 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Joints: Min.4-Inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #6 Maximum Design Pressure=-31S osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM 041 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #7 Maximum Design Pressure=-622.5 Dsf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG 100 or ASTM D41 Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #8 Maximum Design Pressure=-30.0 osf•: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c.at the 3-Inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #9 Maximum Design Pressure=-37.5 osf•: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #10 Maximum Design Pressure=-37.5 osf•: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. NEMO ETC,LLC. Evaluation Report P12060.02.09-R26 Certificate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 7 of 16 NNEnno J etc. #11 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-Inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #12 Maximum Design Pressure=-45 psf*: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt. #13 Maximum Design Pressure=-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-Inch o.c.at the 3-inch wide side laps and 6-Inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #15 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt. #16 Maximum Design Pressure=45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #17 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. NEMO ETC,U.C. Evaluation Report P32060.02.09-R26 Certificate of Authorization#32455 6TH EDITION(2017)FBC NON-HVHI EVALUATION FL5259-R30 Polyglass Roof Underlayments;(964)233-1230 Revision 26:07/06/2020 Page 8 of 16 NNEW I etc. #18 Maximum Design Pressure=-52.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #19 Maximum Design Pressure=-52.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 5-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #20 Maximum Design Pressure=-60 osf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-60 osf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #22 Maximum Design Pressure=-60.Oosf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #23 Maximum Design Pressure=-60.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #24 Maximum Design Pressure=-60.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-Inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. NEMO ETC,U.C. Evaluation Report P12060.02.09-1126 Certli lcate of Authorization#32435 6T"EDITION(20171 FBC NON-HVHZ EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233.1230 Revision 26:07/06/2020 Page 9 of 16 ONNEMOletc. #25 Maximum Design Pressure=-67.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: B-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #26 Maximum Design Pressure=-67.5 osf: Deck: APA rated,19/32 CAT,0,578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #27 Maximum Design Pressure=-67.5 psf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #28 Maximum Design Pressure=-67.5 psf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #29 Maximum Design Pressure=-75 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #30 Maximum Design Pressure=-90osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #31 Maximum Design Pressure=-90 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. NEMO ETC,U.C. Evaluation Report P12060.02.09-R26 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 10 of 16 �.?� ����. ��i �.r�. e r{ i I i � � � �{i U �. '� � i. I .. � .. �, � .� � ,. � 1 .� .. �i�i. NNEMOletc. #32 Maximum Design Pressure=-90 osf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #33 Maximum Design Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underloyment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #34 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #35 Maximum Design Pressure=-90.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180"into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #36 Maximum Design Pressure=-90.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #37 Maximum Design Pressure=-97.5 pst: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-Inch wide side laps and 4-Inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. NEW ETC,[LC. Evaluation Report P12060.02.09-R26 Certificate ofAuthorhation#32455 61H EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233-2230 Revision 26:07/06/2020 Page 11 of 16 NNEMOletc. #38 Maximum Design Pressure=-97.5 osf: Deck: APA rated,19/32 CAT,0.578 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FRI,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #39 Maximum Design Pressure=-97.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #40 Maximum Design Pressure=-97.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #41 Maximum Design Pressure=-205 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #42 Maximum Design Pressure=-105.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. N43 Maximum Design Pressure=-105.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. NEMO ETC,U.C. Evaluation Report P12060.02.09-1126 Certificate of Authorization#32455 6"EDITION(2017)FBC NON-HVHI EVALUATION FL5259.R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 12 of 16 ONNEMOletc. #44 Maximum Design Pressure=-105.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #45 Maximum Design Pressure=-112.5 osf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 13 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c.at the 4-inch wide side laps and 5-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS Plus,self-adhered Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #46 Maximum Design Pressure=-120 osf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #47 Maximum Design Pressure=-120 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt. #48 Maximum Design Pressure=-127.S osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #49 Maximum Design Pressure=-127.5 osf: Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #50 Maximum Design Pressure=-127.5 osf: Deck: APA rated,19/32 CAT,O.S78 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. NEMO ETC,LLC. Evaluation Report P32060.02.09-R26 Certificate of Authorization#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL9259-R30 Polyglass Roof Underlayments;(954)233.1230 Revision 26:07/06/2020 Page 13 of 16 ON NEnno I etc. 5.6.1.1 All other direct-deck, adhered Polyglass underlayment systems beneath adhesive-set tile systems carry a Maximum Design Pressure of-45 psf. 5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 5.7 Exposure Limitations: TABLE 3: EXPOSURE Limn ATioNs Underlayment Maximum Exposure(days) HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU Max,Polystick TU P, 180 Polystick TU Plus or Polystick XFR Polystick IR-Xe or Polystick MU-X 90 Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base 30 180 Elastoflex 56 G,Elastoflex S6 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet (for adhesive-set tile) (FR),Polyflex G,Polyflex G FR,Polyflex SA P or Polyflex SA P FR UNLIMITED (for mechanically fastened roof prepared roof covers) 5.8 Polystick III has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15,should be established as to slip resistance. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polystick NITS Plus Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack(4 over 2) 4:12 Flat 6-tile stack(4 over 2)or 30-tile stack 7:12 Polystick TU Max Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack(4 over 2) 6:12 Lugged 6-tile stack(4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 30-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC,U.C. Evaluation Report P32060.02.09-R26 CertinCate of Authorization#32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL52S9•R30 Polyglass Roof Underlayments;(954)233.1230 Revision 26:07/06/2020 Page 14 of 16 NNEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hide Nail Base: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule- Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.1 herein,coupled with FRSA/TRI April 2012(04-12) Installation Manual. 6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P, Polyflex SA P FR, Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X,Polystick TU Max, Polystick TU P,Polystick TU Plus or Polystick XFR: 6.4.1 General: All seal-lap seams(selvage laps)must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern(the sheet will overlap the fabric). View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro 6.4.2 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements. 6.4.3 Tile Applications(excludes HydraGuard Dual Pro, Polystick IR-Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI April 2012(04-12)and Polyglass published requirements. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self-adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set tile applications,refer to Section 5.6.1 herein. 6.4.4 Multi-Ply Underlavment Systems: Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro,Polyflex SA P,Polystick MTS Plus,Polystick MU-X,Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. NENIO ETC,U.C. Evaluation Report P32060.02.09-R26 Certificate of Authorization#32455 6"'EDITION(2017)FBC NON-HVH2 EVALUATION FLS2S9-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 15 of 16 ON NEMo I etc. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex S6 G or Elastoflex S6 G FR: 6.5.1 Elastoflex 56 G or Elastoflex 56 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the"Two Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System"from FRSA/TRI April 2012(04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the"Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex 56 G or Elastoflex 56 G FR shall be fully asphalt-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in the applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet' in the"Two Ply System"from FRSA/TRI April 2012(04- 12) beneath mechanically fastened or adhered tile roof systems(Refer to Table 2 for base sheet options). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' in the 'Two Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened tile roof systems(Refer to Table 2 for base sheet options). 6.6.2 Polyflex G or Polyflex G FR shall be fully torch-applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter-battens,as required by the tile manufacturer and FRSA/TRI April 2012(04-12)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail-boards, to prevent the sliding and/or damage to the underlayment during the loading process. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. 611320-3 CIA requirements. Refer to Section 4 herein for product&production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314)578-3406; k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEW ETC,U.C. Evaluation Report P32060.02.09-R26 Certificate ofAuthorhation#32455 6TM EDITION)2017)FBC NON-HVHZ EVALUATION FL5259-R30 Polyglass Roof Underlayments;(954)233-1230 Revision 26:07/06/2020 Page 16 of 16