HomeMy WebLinkAboutEnergy CodeFORM k405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Kelly Residence
Builder Name:
Street: 11600 Twin Creeks Drive
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34945
Permit Number.
Owner: Kelly Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1261.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1107AO ft'
b. Frame- Wood, Adjacent
R=11.0 153.68 ft
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ftz
10. Ceiling Types (1513.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1513.00 ftz
6. Conditioned floor area above grade (ftz) 1513
b. NIA
R= ftz
c. NIA
R= ftz
Conditioned floor area below grade (ftz) 0
11. Ducts
R ftz
7. Windows(141.9 sqft.) Description Area
a. Sup: Attic, Ret: AHU, AH: AHU
6 75
a. U-Factor: Sgl, U=0.66 141.94 ftz
SHGC: SHGC=0.32
b, U-Factor: N/A ftz
12. Cooling systems
kBtu/hr Efficiency
a. Central Unit
29,4 SEER:16.00
SHGC:
c. U-Factor: NIA ftz
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor. N/A ftz
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 4.067 ft.
Area Weighted Average SHGC: 0.320
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1513.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1513.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
CF, Pstat
Area: 0.094 Total Proposed Modified Loads: 46.39
CS
PASS
Glass/Floor
Total Baseline Loads: 47.56
/�1r7�7
I hereby certify that the plans and specifications covered by
Review of the plans and
MM' STq�
=
this calculation are in compliance with the Florida Energy
specifications covered by this
��yo �0�, .
ram'
'�
Code. A_r /
calculation indicates compliance
��' �•' {
�-ss_ 0 +
a
t / V-�'� ���///
with the Florida Energy Code.
Before construction is completed
,
PREP/�R5D TY:
DATE: jj '-
this building will be inspected forO�p✓
compliance with Section 553.908
a
hereby certify that this�inadesigned, is in compliance
Florida Statutes.--�
1i�C
Op
with the Florida Ener Co
ti1'E'�
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE:
v
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.3.2.1,
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402,4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402AA.2).
FILE COPY
9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT. 5UMMAKY UHhL;KLI5T KEPUKT
PROJECT
Title: Kelly Residence
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1513
Lot #
Owner Name: Kelly Residence
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
11600 Twin Creeks Driv
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34945
New/Existing: New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1513 12255.3
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Master Bath
135 1093.5 No 0
1 Yes
Yes
Yes
2 WIC
72 583.2 No 0
1 Yes
Yes
Yes
3 Bedroom 2
238 1927.8 No 1
1
1 Yes
Yes
Yes
4 Bath
78 631.8 No 0
1 Yes
Yes
Yes
5 Master Bedroom
290 2349 No 2
1
1 Yes
Yes
Yes
6 AHU
9 72.9 No 0
1 No
Yes
Yes
7 Great Room
425 3442.5 No 0
1 Yes
Yes
Yes
8 Kitchen
143 1158.3 Yes 1
1 Yes
Yes
Yes
9 Laundry
91 737.1 No 0
1 No
Yes
Yes
10 Hall
32 259.2 No 0
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Master Bath 24 ft
135 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulatio
WIC 8 ft
72 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulatio
Bedroom 2 31 ft
238 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio
Bath 5 ft
78 ft2
----
1 0
0
5 Slab -On -Grade Edge Insulatio
Master Bedroom 13 ft
290 ft2
_---
1 0
0
6 Slab -On -Grade Edge Insulatio
AHU 1 ft
9 ft2
----
1 0
0
7 Slab -On -Grade Edge Insulatio
Great Room 43 ft
425 ft2
----
1 0
0
9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
F8
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
Slab -On -Grade Edge Insulatio Kitchen 13 ft
143 ft2
----
1
0
0
9SIab-On-Grade Edge Insulatio Laundry 1 ft
91 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio Hall 1 ft
32 ft2
----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles .1639 ft2
0 ft2
Medium
N
0.6
No
0.9
No 0
22.6
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1513 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_
1
Under Attic (Vented) Master Bath
30
Batt
135 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Batt
72 ft2
0.1
Wood
3
Under Attic (Vented) Bedroom 2
30
Batt
238 ft2
0.1
Wood
4
Under Attic (Vented) Bath
30
Batt
78 ft2
0.1
Wood
5
Under Attic (Vented) Master Bedroom 30
Batt
290 ft2
0.1
Wood
6
Under Attic (Vented) AHU
30
Batt
9 ft2
0.1
Wood
7
Under Attic (Vented) Great Room
30
Batt
425 ft2
0.1
Wood
8
Under Attic (Vented) Kitchen
30
Batt
143 ft2
0.1
Wood
9
Under Attic (Vented) Laundry
30
Batt
91 ft2
0.1
Wood
10
Under Attic (Vented) Hall
30
Batt
32 ft2
0.1
Wood -
WALLS
Qrnt
Adjacent Space
10 Wnll Type1
Cavity Width
Height
Sheathing Framing Solar
Belo w
NE
Exterior Concrete Block - Int InsWaster Bath
4.1 15
0 8
1
121.3 ft2
0
0
0.6
0
2
NW
Exterior Concrete Block - Int InsWaster Bath
4.1 9
0 8
1
72.8 ft2
0.
0
0.6
0
3
NE
Exterior Concrete Block - Int Insul WIC
4.1 8
0 8
1
64.7 ft2
0
0
0.6
0
_ 4
NE
Exterior Concrete Block - Int InsuBedroom 2
4.1 17
0 8
1
137.4 ft2
0
0
0.6
0
5
SE
Exterior Concrete Block - Int InsuBedroom 2
4.1 14
0 8
1
113.2 ft2
0
0
0.6
0
6
SE
Exterior Concrete Block - Int Insul Bath
4.1 5
0 8
1
40.4 ft2
0
0
0.6
0
7
NW
Exterior Concrete Block - Int InsMaster Bedro
4.1 13
0 8
1
105.1 ft2
0
0
0.6
0
8
SW
Exterior Concrete Block - Int InsdBreat Room
4.1 27
0 8
1
218.3 ft2
0
0
0.6
0
9
NW
Exterior Concrete Block - Int Insd3reat Room
4.1 16
0 8
1
129.3 ft2
0
0
0.6
0
_ 10
SW
Exterior Concrete Block - Int Insul Kitchen
4.1 13
0 8
1
105.1 ft2
0
0
0.6
0
11
SE
Garage Frame - Wood Bath
11 1
8
1
8.1 ft2
0.23
0.6
0
_ 12
SE
Garage Frame - Wood Laundry
11 7
8
1
56.6 ft2
0.23
0.6
0
9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT
WALLS
()rnt
Adjacent
10 Wall
TypeSpace
Cavity Width
Height
Area
Sheathing Framing Solar Below
r
13 SE
Garage Frame - Wood
Kitchen 11 11 8
1 88.9 ft2
0.23 0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value Width Height
Ft In Ft In
Area
1
2
SW
SE
Wood
Wood
Great Room None
Laundry None
.39 3
.39 3
6 10
6 10
20.5 ft2
20.5 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
v #
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
NW 2 Metal
NE 4 Metal
NW 7 Metal
SW 8 Metal
SW 8 Metal
NW 9 Metal
SW 10 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.66 0.32 Y
0.66 0.32 Y
0.66 0.32 Y
0.66 0.32 Y
0.66 0.32 Y
0.66 0.32 Y
0.66 0.32 Y
12.0 ft2 1 ft 7 in
15.0 ft2 1 ft 7 in
30.0 ft2 1 ft 7 in
30.0 ft2 8 ft 0 in
15.9 ft2 8 ft 0 in
30.0 ft2 1 ft 7 in
9.0 ft2 8 ft 0 in
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
729 ft2
729 ft2
19 ft
8.1 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.00036
1429.8 78.49 147.62 .1255
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Sing] SEER: 16 29.4 kBtu/hr
cfm 0.7 1
sys#1
9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
--- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 75 ft2
AHU
15 ft2
Default Leakage
AHU
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating f X Jan EX Feb
f X1 Mar
Apr
May
Jun
Jul
ri
Aug
rl
Sep
rj
�j Oct
Oct
Nov
Nov
Dec
Dec
Venting [ Jan [ Feb
X Mar
Jun Jul
Aug
Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
6.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/s .ft.
ft2
ft
0.3
Hall
9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 r AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Kelly Residence Builder Name:
Street: 11600 Twin Creeks Drive Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL , 34945 Permit Number:
Y
U
Owner: Kelly Residence Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
9s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind popono and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sor'nkler cover plates and walls Qr ce*lonas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/21/2020 6:59 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
AHU
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
29.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1513
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.660
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.320
14. Heating system: Capacity
27.0
c) Area
7c.
141.9
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has compli d with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be instaIle or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be co ete ed o i ailed code compliant features.
Builder Signatu
Date: 16 z ') Zb
Address of New Home: 11600 Twin Creeks Drive City/FL Zip: Fort Pierce, FL 34945
9/21/2020 6:59:19 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1