HomeMy WebLinkAboutEnergy CodeFORM k405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Kelly Residence Builder Name: Street: 11600 Twin Creeks Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 Permit Number. Owner: Kelly Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1261.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1107AO ft' b. Frame- Wood, Adjacent R=11.0 153.68 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. N/A R= ftz 10. Ceiling Types (1513.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1513.00 ftz 6. Conditioned floor area above grade (ftz) 1513 b. NIA R= ftz c. NIA R= ftz Conditioned floor area below grade (ftz) 0 11. Ducts R ftz 7. Windows(141.9 sqft.) Description Area a. Sup: Attic, Ret: AHU, AH: AHU 6 75 a. U-Factor: Sgl, U=0.66 141.94 ftz SHGC: SHGC=0.32 b, U-Factor: N/A ftz 12. Cooling systems kBtu/hr Efficiency a. Central Unit 29,4 SEER:16.00 SHGC: c. U-Factor: NIA ftz SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ftz a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 4.067 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1513.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1513.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits CF, Pstat Area: 0.094 Total Proposed Modified Loads: 46.39 CS PASS Glass/Floor Total Baseline Loads: 47.56 /�1r7�7 I hereby certify that the plans and specifications covered by Review of the plans and MM' STq� = this calculation are in compliance with the Florida Energy specifications covered by this ��yo �0�, . ram' '� Code. A_r / calculation indicates compliance ��' �•' { �-ss_ 0 + a t / V-�'� ���/// with the Florida Energy Code. Before construction is completed , PREP/�R5D TY: DATE: jj '- this building will be inspected forO�p✓ compliance with Section 553.908 a hereby certify that this�inadesigned, is in compliance Florida Statutes.--� 1i�C Op with the Florida Ener Co ti1'E'� OWNER/AGE BUILDING OFFICIAL: DATE: DATE: v - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1, - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402,4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402AA.2). FILE COPY 9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT. 5UMMAKY UHhL;KLI5T KEPUKT PROJECT Title: Kelly Residence Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1513 Lot # Owner Name: Kelly Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 11600 Twin Creeks Driv Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34945 New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1513 12255.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bath 135 1093.5 No 0 1 Yes Yes Yes 2 WIC 72 583.2 No 0 1 Yes Yes Yes 3 Bedroom 2 238 1927.8 No 1 1 1 Yes Yes Yes 4 Bath 78 631.8 No 0 1 Yes Yes Yes 5 Master Bedroom 290 2349 No 2 1 1 Yes Yes Yes 6 AHU 9 72.9 No 0 1 No Yes Yes 7 Great Room 425 3442.5 No 0 1 Yes Yes Yes 8 Kitchen 143 1158.3 Yes 1 1 Yes Yes Yes 9 Laundry 91 737.1 No 0 1 No Yes Yes 10 Hall 32 259.2 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bath 24 ft 135 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio WIC 8 ft 72 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 2 31 ft 238 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Bath 5 ft 78 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Master Bedroom 13 ft 290 ft2 _--- 1 0 0 6 Slab -On -Grade Edge Insulatio AHU 1 ft 9 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Great Room 43 ft 425 ft2 ---- 1 0 0 9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS F8 # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet Slab -On -Grade Edge Insulatio Kitchen 13 ft 143 ft2 ---- 1 0 0 9SIab-On-Grade Edge Insulatio Laundry 1 ft 91 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Hall 1 ft 32 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles .1639 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1513 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) Master Bath 30 Batt 135 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Batt 72 ft2 0.1 Wood 3 Under Attic (Vented) Bedroom 2 30 Batt 238 ft2 0.1 Wood 4 Under Attic (Vented) Bath 30 Batt 78 ft2 0.1 Wood 5 Under Attic (Vented) Master Bedroom 30 Batt 290 ft2 0.1 Wood 6 Under Attic (Vented) AHU 30 Batt 9 ft2 0.1 Wood 7 Under Attic (Vented) Great Room 30 Batt 425 ft2 0.1 Wood 8 Under Attic (Vented) Kitchen 30 Batt 143 ft2 0.1 Wood 9 Under Attic (Vented) Laundry 30 Batt 91 ft2 0.1 Wood 10 Under Attic (Vented) Hall 30 Batt 32 ft2 0.1 Wood - WALLS Qrnt Adjacent Space 10 Wnll Type1 Cavity Width Height Sheathing Framing Solar Belo w NE Exterior Concrete Block - Int InsWaster Bath 4.1 15 0 8 1 121.3 ft2 0 0 0.6 0 2 NW Exterior Concrete Block - Int InsWaster Bath 4.1 9 0 8 1 72.8 ft2 0. 0 0.6 0 3 NE Exterior Concrete Block - Int Insul WIC 4.1 8 0 8 1 64.7 ft2 0 0 0.6 0 _ 4 NE Exterior Concrete Block - Int InsuBedroom 2 4.1 17 0 8 1 137.4 ft2 0 0 0.6 0 5 SE Exterior Concrete Block - Int InsuBedroom 2 4.1 14 0 8 1 113.2 ft2 0 0 0.6 0 6 SE Exterior Concrete Block - Int Insul Bath 4.1 5 0 8 1 40.4 ft2 0 0 0.6 0 7 NW Exterior Concrete Block - Int InsMaster Bedro 4.1 13 0 8 1 105.1 ft2 0 0 0.6 0 8 SW Exterior Concrete Block - Int InsdBreat Room 4.1 27 0 8 1 218.3 ft2 0 0 0.6 0 9 NW Exterior Concrete Block - Int Insd3reat Room 4.1 16 0 8 1 129.3 ft2 0 0 0.6 0 _ 10 SW Exterior Concrete Block - Int Insul Kitchen 4.1 13 0 8 1 105.1 ft2 0 0 0.6 0 11 SE Garage Frame - Wood Bath 11 1 8 1 8.1 ft2 0.23 0.6 0 _ 12 SE Garage Frame - Wood Laundry 11 7 8 1 56.6 ft2 0.23 0.6 0 9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT WALLS ()rnt Adjacent 10 Wall TypeSpace Cavity Width Height Area Sheathing Framing Solar Below r 13 SE Garage Frame - Wood Kitchen 11 11 8 1 88.9 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 2 SW SE Wood Wood Great Room None Laundry None .39 3 .39 3 6 10 6 10 20.5 ft2 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. v # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 NW 2 Metal NE 4 Metal NW 7 Metal SW 8 Metal SW 8 Metal NW 9 Metal SW 10 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes 0.66 0.32 Y 0.66 0.32 Y 0.66 0.32 Y 0.66 0.32 Y 0.66 0.32 Y 0.66 0.32 Y 0.66 0.32 Y 12.0 ft2 1 ft 7 in 15.0 ft2 1 ft 7 in 30.0 ft2 1 ft 7 in 30.0 ft2 8 ft 0 in 15.9 ft2 8 ft 0 in 30.0 ft2 1 ft 7 in 9.0 ft2 8 ft 0 in 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 729 ft2 729 ft2 19 ft 8.1 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00036 1429.8 78.49 147.62 .1255 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 16 29.4 kBtu/hr cfm 0.7 1 sys#1 9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 75 ft2 AHU 15 ft2 Default Leakage AHU (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating f X Jan EX Feb f X1 Mar Apr May Jun Jul ri Aug rl Sep rj �j Oct Oct Nov Nov Dec Dec Venting [ Jan [ Feb X Mar Jun Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 6.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/s .ft. ft2 ft 0.3 Hall 9/21/2020 6:58 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 r AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Kelly Residence Builder Name: Street: 11600 Twin Creeks Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34945 Permit Number: Y U Owner: Kelly Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 9s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popono and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sor'nkler cover plates and walls Qr ce*lonas. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/21/2020 6:59 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1513 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.660 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.320 14. Heating system: Capacity 27.0 c) Area 7c. 141.9 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has compli d with the Florida Building Code, Energy Conservation, through the above energy saving features which will be instaIle or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be co ete ed o i ailed code compliant features. Builder Signatu Date: 16 z ') Zb Address of New Home: 11600 Twin Creeks Drive City/FL Zip: Fort Pierce, FL 34945 9/21/2020 6:59:19 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1