Loading...
HomeMy WebLinkAboutPlot Plans40'-0- 26'-0" Building Data Project Data 1 "• t 8"" 3'-2'" 3'-� 3'-8"' 3'-62" 7'-9" 11'-7"" 5'-5 25 s.h. Egress co Cing. Grob CF "" .o 4 0-0 cone. pad. Fasten 8'-1 13q Cing. �O�CIo�� co wXle > rete using thet to metal using the metal B d rm. 2 anchor flange by � _ _ 22.5 x 36 c> i 8'-1"Ceiling manufacturer with 1/4'" x 3" tapcons 3068 r� 3068 I Access I typical (4) places Pocket u Po et L----� ��� 10'-11 "" 3'-0" 2' 0" 5-5'" 13'-6" 2' " 8' T-8" 10'-0" 8'-0- 2'-4" 2 xl2 CC, Master Bdrm. r� 8'-1 "Ceiling �� O � ��� HB 2868 8'-1- 19'-6" 2' 3'-9" 3'-1 Cr nl v tv 1� In,�g t� coo .`� 3068-------- o� 200A o wh r O 8070 Overhead m 7Boilard o a w Electric Panel Cing. 30 -- ` - L al`G�( 11 " 3068sc 2'- '-4'"10x(pX-1� Closer 25' g" / / � I I 3068 22.5 x 54 Access / Pocket with Ladder wafer P Rt 1 Batt insul. I I N N I in Adj. Wall o/ Great Room 0I 2068 I I ! I I Garage 2.5/12 Slope Cing. 18-7 Lr-� I I I I 8'-1"Cing. /Uecv� /UX Iv^p a, Kltche to)Clo)/ Op Exp.Joint L--J from F.F.E. CP / Cnge& 2.5/12 Slope In Exh. Hood 00 / 26'-5" / Farm / Sink / 3068 Dr. with / (2) 14"impact ' d N --- desk— a ❑ J sidelites P5 25 23 I s.h. s.h. a s.h. 3068 II N HB II �I Porch I Vinyl Ceiling �I 8'-1 ""Cing. � I l 4 x 4 p.t. columns from F.F.E. I with (2) 2 x 12 beam with 1 /2" plywd. flitch 10070 Overhead 10070 Overhead -------- ------ -------------- -- —� _� -----�---- ---- T� - M 5'-6" 4'-62"' 3'-1021" 5'-92"' 2'-72" T-1"' 4'-7" 5'-1" 2'-4" 10'-0" 2'-4" 10'-0" 2'-4" 39'-0" 27'-0- 66'-0`" scale: 1 /4" = 1'-0" ALL GLAZING TO BE IMPACT RATED WOOD TRIM TO BE STAINED 2 1/4"CASING AROUND WINDOWS Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 3092 s.f. 6th Edition Florida Building Code: Residential 2014 National Electric Code NFPA 70 Imo. —r • -..� • Living: 1513 Garage: 743 Porch: 312 Total: 2568 Total Cubic Volume: XXXX c.f. Project Name: Kelly residence Street Address: T.B.D. City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New one level CBS single family residence Design Loads Roof Live Load: 20.0 p.s.f. Floor Live Load: 40.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor. 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefflcent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 I FPL Insulation Smoke Developed Index: Not to exceed 450 F Meter Wall Finishes: Not greater than 200 C q Ceiling Finishes: Not greater than 200 Climatic & Geographic Design Criteria 24 Weathering: Negligible Termite Area: Very Heavy s.h. B o o FIBERGLASS SHINGLES N ON 30# ROOFING FELT OVER 5/8"' C.DX PLYWOOD 12 SEE CONNECTOR 5� SCHEDULE PRE ENG. WD. TRUSSES 24""c.c. R30 BATT 24 INSULATION s.h. ALUM. DRIP EDGE ON 1x2P.T.ON2x6 CEDAR FASCIA -� L 5/8' DW 1 x 2 P.T. FIRESTOP VENTED VINYL SOFFIT (2) COURSE BOND BEAM WITH (1) #5 LEVEL RETURNS REBAR FILLED WITH BY TRUSS MFG. 1-6 GROUT EACH COURSE 8 x 16 x 8 C.M.U. WITH #5 VERT. DOWEL PROVIDE-CASTCRETE- IN GROUT FILLED CELLS PRECAST LINTELS ABOVE ALL OPENINGS 7=:4i 1 x 2 P.T. FURRING 24"o.c. 3/4- INSULATION BRD. TWO COAT ON C.B.S. AND 1 x 2 STUCCO FINISH FURRING 24-o.c. OVER CBS � 1 /2'" GYP. D.W. GRADE :r 1 x 2 P.T. FIRESTOP 4- 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL Typical Wall Section U co 04 L Lu Z v U- � _W (n LL fl N ono cD ® J Lj n •� CU F" Z N a U Lu o rn W to o rn VJ drawn :.I. checked S.I. date 9/2/2020 scale as noted job number 20050 sheet A-1