HomeMy WebLinkAboutEngineer Letter Architectonic Inc St. Lucie County Planning&Development Services Building&Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 November 25,2020 RE: 3501 Shinn Road,SLC Fire Station#11 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2017 Florida Building Code, 160 mph wind zone, exposure"C", risk category III. From Table 1609.3.1: V,,,t= 165mph From Table 1609.7(1): 12'2" h x 12'9"'w door, 165 mph=-24.3/-27.5 From Table 1609.7(2): 15' mean roof height, Exposure C=1.21 Required Design Pressures: 24.3 X 1.21=29.4 -27.5 X 1.21=33.2 Product:Clopay Building Products Commercial Ribbed Door, NOA#20-0512.03 Product Pressures: +36.0&-42.0 Respectfully Submitted, OF .Rj ich al, I y R96898 F- c, 'tpctoni ; c9a 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce,Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1