HomeMy WebLinkAboutDOC121020-001Mike Halter
From: Chrissy Chapman <chrissy@dreroofconsulting.com>
Sent: Tuesday, December 8, 2020 1:57 PM
To: Mike Halter
Cc: Shannon Duhon; Katie Velzy
Subject: RE: Tropicana Fee Mill -Warehouse, Sutter Roofing CO. permit 2011-0190 Saint Lucie
County
SECURITY WARNING: This email originated from outside the County systems. Please show caution when
clicking links or opening attachments unless you recognize the sender and know the content is safe.
Good afternoon Mike,
Please see the following response from our Engineer regarding this project:
"The change for the panels from 24 gauge to 22 gauge was as per client request. The reason for the change was that the
only Florida Product Approval for a corrugated panel available was for a 24-gauge panel.
There are numerous other approvals that have structural panels in both gauges. The added stiffness of a 22-gauge panel
decreases the deflection and strengthens the fastener pullover values. The fasteners would fail, however,
before any torque affects the structural framing. This is an opinion only. Any formal statements may require structural
testing." Don Flood, P.E.
Best regards,
Chrissy Chapman
Testing Administrator
Duhon's Roof Consulting, LLC
4875 Park Ridge Blvd., Suite 108
Boynton Beach, FL 33426
O: 561.734.3818
chrissy(Pdreroofconsulting. com
* BBB
E-mail s from this firm normally contain confidential and privileged material, and are for the sole use of the intended recipient. Use
or distribution by an unintended recipient is prohibited, and may be a violation of law. If you believe that you received this e-mail in
error, please do not read this e-mail or any attached items. Please delete the e-mail and all attachments, including any copies
thereof, and inform the sender that you have deleted the e-mail, all attachments and any copies thereof. Thank you.
From: Mike Halter <halterm@stlucieco.org>
Sent: Monday, December 7, 2020 7:46 AM
To: Chrissy Chapman <chrissy@dreroofconsulting.com>
Subject: RE: Tropicana Fee Mill -Warehouse, Sutter Roofing CO. permit 2011-0190 Saint Lucie County
Thanks Chrissy!
From: Chrissy Chapman <chrissy@dreroofconsulting.com>
Sent: Thursday, December 3, 2020 4:17 PM
To: Mike Halter <halterm(c@stlucieco.org>
Cc: Shannon Duhon <sduhon@dreroofconsulting.com>: Katie Velzy <katie@dreroofconsulting.com>
Subject: RE: Tropicana Fee Mill -Warehouse, Sutter Roofing CO. permit 2011-0190 Saint Lucie County
SECURITY WARNING: This email originated from outside the County systems. Please show caution when
clicking links or opening attachments unless you recognize the sender and know the content is safe.
Hi Mike,
Thank you for reaching out. Your request has been forwarded to our Engineer and we will get back with you as soon as
we receive an answer.
Have a great evening!
Best regards,
Chrissy Chapman
Testing Administrator
Duhon's Roof Consulting, LLC
487S Park Ridge Blvd., Suite 108
Boynton Beach, FL 33426
O: 561.734.3818
chrissv@dreroofconsulting.com
BBB
E-mails from this firm normally contain confidential and privileged material, and are for the sole use of the intended recipient. Use
or distribution by an unintended recipient is prohibited, and may be a violation of law. If you believe that you received this e-mail in
error, please do not read this e-mail or any attached items. Please delete the e-mail and all attachments, including any copies
thereof, and inform the sender that you have deleted the e-mail, all attachments and any copies thereof. Thank you.
From: Mike Halter <halterm@stlucieco.org>
Sent: Thursday, December 3, 2020 10:32 AM
To: Chrissy Chapman <chrissy@dreroofconsulting.com>
Subject: Tropicana Fee Mill -Warehouse, Sutter Roofing CO. permit 2011-0190 Saint Lucie County
Good morning Chrissy,
I have been working with Ed Marrero of Sutter Roofing to complete his permitting process and he has directed
me to you for help with the building structure stiffness concern from the submitted roof wind pressure & attachment
design report dated 11/16/2020. The concern is whether or not the building will be too rigid with the 22 — gauge steel
corrugated panels with respect to torque loading of the existing building's columns and beams. I am requesting if the
design report could be amended to address the stiffness concern. I greatly appreciate your help with this concern and
please contact me for any additional information.
The County is OPEN for business, though, the building remains closed to the general public to
keep our citizens and employees safe during the pandemic. The Building Department is
operating in a new location, just a few feet from the main lobby, at the $W corner of the
building (formerly the Utilities Department). Look for the GREEN A -Frame signs. The hours of
operation are Monday — Friday from 8:00 am to 4:30 am. All staff is available by email or
phone.
Please be safe during these unprecedented times while we do our best to help the community
remain safe as we operate at the new normal. If you need to contact me, my direct extension is
462-64b3.
Please be safe during these unprecedented times while we do our best to help the community
remain safe as we continue to operate at the new normal.
Thank you
JVLitlaef 9r V.A., P.E
Electrical Engineer
Plans Examiner
Building Inspector
CFM
772 462 6453
2300 Virginia Ave.
Fort Pierce, FL 34982
3.. .. ,�.4[ Wtt t)ic c ..r_ N1t.:.I �„i yi 9i;li;,ci r' ~r ,SSAt ,..xl rirc z'uc
..•A. o,%ttta I, rty ;, ,)Hz �11r f
n i..t r=_:ai11;1 tot". i„�., '�a.� i..�s re x,�.-. ,.ia;t, Cn, .::c i,tan .o. .�e,t �.ra
�,. .,ri ^iislr. ., t, b%;tt ti I n�ti..t 1. ^, alI t i+txs.