Loading...
HomeMy WebLinkAboutRevision OFFICE USE ONLY: DATE FILED: PERMIT# REVISION FEE: RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982.6652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: .v Me r a c �. CONTRACTOR INFORMATION: STATE of FL REG./CURT.#: GCCt330 Oro Z ST.LUCIE CO CERT.#: BUSINESS NAME: �7- to a k o v roc QUALIFIERS NAME: e ( cn ADDRESS: d 1/e Vj CITY: L°r STATE. ZIP: 3Z PHONE(DAYTIME): -7 Z- S'Z8- 7rn a FAX: OWNER/BUILDER INFORMATION: NAME: v✓'CA�Z A N C7 ADDRESS: J Q CITY: i STATE: ZIP: z 2- PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: t� h ; SLCCC: 9123109 -4 Revised 06130117 � �fi t INTEGRITY Za o - m37 / MEMETALS 2604 Piper St Ste B T Vero Beach FL 32609 METAL ROOFING MADE HERE (772) 584-2654 IM100 IntegriLok 26 gauge (min) 16" wide nail strip panel over 15/32" plywood Florida Product Approval Number 28113 Compliance statement: This product as described has demonstrated compliance with Florida Building Code 2017, Section 1504.3.2, as required by Rule 61 G20-3, method 1 D Manufacturer: Integrity Metals, LLC 12640 Piper Dr, Ste. B, Vero Beach, FL 32960 1 772-584-2654 1 www.intregritymetalsf,. Product: IntegriLok IM100 is a nailstrip panel with a 16" maximum panel width, and nominal rib height of 1." Material: This product is manufactured from 26ga or thicker steel with yield strength of at least 50ksi, and corrosion resistance per FBC 1507.4.3. Fastener: #10 x 1" low-profile style fastener compliant with FBC 1506.6. Substrate/Deck: Minimum 15/32" thick plywood. Underlayment: Comply with FBC 1507.1.1 where applicable Slope: Comply with FBC 1507.4.2 where applicable. Technical Documentation: This product has been tested to the UL 580-06 standard by Intertek Testing (TST-1527), report 17726.05-450-44 R0. This test report is owned by Quality Metal Roof Fabricators, who has given written authorization for Integrity Metals to use this report. This product has also been tested to UL 580-06 and UL 1897-15 by Intertek, report K4846.01-450-44 R0. Max. Allowable Loads & Method A: 86psf I Install fasteners every other hole (±10" o.c.). Installation Requirements: Method B: 108.5psf I Use self-adhering underlayment and install fasteners in every hole (±5" o.c.). N Factor of Safety of 2.0 applied to calculate allowable loads. Evaluated By: David Eng, PE Timberlake Cove, LLC ] Cop E. �, 3324 W Univ.��p fN ,�� U Ave # 206, Gainesville FL 2 /�/ 2� P.• ' eNs .G PE Lic. No: 81377 �L t/ J ( O: �Xc e � I y.J�13T 77 CA Lic. No: 33344 REVIEWED FOR www.timberiakecove.com BODE COMPLIANCE ST. L CIE COUNTY O ' 'C FCOR�OP.•' �:� www.IntegrityMeta[sFI.com Uy1BOCC Page�1 ONA%;` , `/ INTEGRITY METALS 2604 Piper St Ste B 1 Vero Beach FL 32609 METAL ROOFING MADE HERE (772).584-2654 Certification-of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclus�oris Si Lim�tat�ons Design of deck and roof structure shall be completed by others. -Fire:classification is not part of this evaluation ` Shear;diaphragm design is outside the scope'of this t �z evaluation. f This report is limited to compliance-with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20 3 Timberlake Cove is not responsible for-any conclusions, a - <rnterpretat ions,,or designs made by others based on this evaluatron:reporf this report is Iimltedssolely to documenting compliance with Rule 61G20-3 ." , and makes no .` x express or implied warranty regarding performance of:=this w protluct Design Process. 'The load table In this report prescribes the fastening 3 :` _ .. �reguirement�for the applicable wintl loads for roofs'within� 1 3 the described, ro For ofs outside of the:listed i , P 3 parameters;°design wmdloads shall be determined as required by;FBC 1609, using:allowable stress Engineering-analysis for""project specific approval"by local E; authorities tiavmg juristlictionn is allowed by other licensed -priglneers, x 1 } t q. f": g ,t'�}4 a 3e E1� d §, ;,,J+h .yp- ""§'5 �g �..:.r• F ',1` c y A" „4 f �4"2 i�+ www.IntegrityMeta[sF[.com Page 2 INTEGRITY METALS 2604 Piper St Ste B i Vero Beach FL 32609 MEIAL ROOFING MADE HERE (772) 584-2654 i Design Load Tables: Instructions: a i 3 2 2 3 2 1 2 Select the appropriate load table that applies to >2\�the structure in question. 2 2 2 3ta Determine the design wind speed for the 2 2 s project location. / _ 1 2 Use the attachment method indicated for that r windspeed within each roof zone. ; 3 a _ 7 v L- nxoE�wsrw¢artrwvroxanD«wwc.x,eW,ssuu,Ea e�.w. ussmwEJI191�\6�.x Noa�rtu ewc..sw�cw sows M.lt pEfEFMWEDBV OFYaNCRODHN9tKwBE CW! ROOF ZONES FOR GENERIC BUILDING Method A: (1) #10 x 1" (min) p fastener every other hole (±10" o.c.) Method B: (1) #10 x 1" (min) fastener every hole (±5" o.c.) with 0 self-adhering underlayment Applies to: Applies to: E)posure: B E)posure: Any 30' max mean roof height 30' max mean roof height Gable roofs between 1.5:12 and 12:12 Gable roofs between 0:12 and 12:12 Hip roofs between 1.5:12 and 6:12 Hip roofs between 0:12 and 6:12 Low rise, regular shaped buildings per ASCE 7-10 Low rise, regular shaped buildings per ASCE 7-10 No unusual site or building characteristics which No unusual site or building characteristics which require further consideration require further consideration FL 28113: 26ga I 100 on 15/32 plywood FL 28113: 26ga IM 100 on 15132 plywood Wind: 120 130 140 150 160 170 180 200 Wind: 120 130 140 150 160 170 180 200 Zone 1 A I A I A I A I A A A A Zone 1 A A A A A A A A Zone 2 JAJAJAJAJA A A A Zone 2 JA JA A JA JA 18 16 * ± ' Zone 3 A I A I A I A I A A I A B Zone 3 JA JA B IB *** *** *** *** www.IntearityMetalsFLcom Page 3