HomeMy WebLinkAboutPROJECT INFO2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WENDELL & TERESA FINCH Builder Name:
Street: 7991 PLANTATION LAKES DR. Permit Office: ST. LUCIE COUNTY
City, Slate, Zip: PORT ST. LUCIE , FL, Permit Number:
x
Owner: WENDELL & TERESA FINCH Jurisdiction: 6611000
Lu
Design Location; FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed,
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier,
Windows, skylights
The space between windowldoorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rtm joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation,
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the cravdspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
(,xignd behind piping aUd wiring,
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tugs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
-between fore sDri9kIq.[ cover ylates and walls or i
u „ uuI —T1, IE13peuilull u[ Icig Walls slid l WC Ili cluuulud#IL:C VVILII ihu pluvisiunb of ICC-400.
12/10/2020 9:17 AM EnergyGaugeO USA 6.O.D2 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12, Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
0
13. Cooling system: Capacity
23.6
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Groundiwater source SEER/GOP
6. Conditioned floor area (sq. ft.)
6.
792
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.500
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.300
14. Heating system: Capacity
15.2
c) Area
7c.
36.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11, Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Fiarida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 7991 PLANTATION LAKES DR. Gity1FL Zip: PORT ST. LUCIE, FL
12/10/2020 91 T04 AM SnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+�- wrightsoft� Project Summary Job:
Entire House Date:
Br•
QUICK CALCS, INC.
317 ST_ LUCIE LANE, FT. PIERCE, FL 34946 Pho-:772-466-6799 Email: QUICKCALCS@AOL.COM
For: WENDELL &TERESA FINCH
7991 PLANTATION LAKES DR., PORT ST LUCIE, FL
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db
Inside db
Design TD
Summer Design Conditions
42 °F Outside db
70 'F Inside db
90
75
°F
°F
28 °F Design TD
15
°F
Daily range
M
Relative humidity
50
Moisture difference
61
gr/Ib
Heating Summary
Structure
13541
Btuh
Ducts
1794
Btuh
Central vent (0 cfm) 0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
15335
Btuh
Method
Construction quality
Fireplaces
Area (ftZ
Volume (T)
Air changes/hour
Equiv.AVF (cfm)
Infiltration
Simplified
Average
0
Hea 792
Coo1791
7128
7128
0.61
0.32
72
38
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
100 EFF
Heating input
4.4
kW
Heating output
15157
Btuh
Temperature rise
18
°F
Actual air flow
787
c im
Air flow factor
0.051
cfm/Btuh
Static pressure
0
in H2O
Space thermostat
Sensible Cooling Equipment Load Sizing
Structure
13808
Btuh
Ducts
1189
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
14247
Btuh
Latent Cooling Equipment Load Sizing
Structure
2388
Btuh
Ducts
930
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
3318
Btuh
Equipment Total Load (Sen+Lat)
17565
Btuh
Req. total capacity at 0.70 SHR
1.7
ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN
Cond GSX160241F
Coil ASPT33C14A
AHRI ref 201498260
Efficiency 13.0 EER, 16 SEER
Sensible cooling
16520
Btuh
Latentcooling
7080
Btuh
Total cooling
23600
Btuh
Actual airflow
7$7
cfm
Air flow factor
0.052
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.82
Calculafions approved byACCA to meet all requirements of Manual J 8th Ed.
2020-0ec-10 06:4a30
�� """"' """"`^'"'• �'• Right SutepLkwersa1241919.0.21 RSU08101
...rlslWrighsofli-IUAC+INCH,VVENDELL&TERESA.rup Calc-MJ8 FrorlDoorfacesN Page
+�- wrightsofi- Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY:
317 ST. LUCiE LANE, FT. PIERCE, FL 34945 Phone: 772-466-6799 Fmni�- ni urur� o
Calculations aPProved b ACCA to meet all requirements of Manual J Sth Ed.
�— wragFatsaYt�
ght-SuteU Urnversaf 2019 19.0.21 RSU08101 2020-Dec-10 08:49:30
...r%swFightsoft I-i5/AMPINCH, WENOELL & TERESA-rq) Ca1c= MJ8 Front Odor PaceS: N Page 1
wrightsoft® Duct System Summary ate:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Prone: 772-466-6799 Emaii: QUICKCALCS@AOL.COM
For: WENDELL &TERESA FINCH
7991 PLANTATION LAKES DR., PORT ST. LUCIE. FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest fiction rate
Actual air low
Total effective length (TEL)
Heating
0
in H2O
0
in H2O
0
in H2O
0.000 / 0.000
in H2O
0
in/100ft
787
cfm
192
Cooling
0 in H2O
0 in H2O
0 in H2O
0.000 / 0.000 in H2O
0 in/100ft
787 cfm
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
GARAGE
c 3749
197
197
0
0
Ox 0
VIFx
5.0
95.0
GARAGE -A
C 3749
197
197
0
0
Ox 0
MFx
12.4
95.0
GARAGF-a
c 3749
197
197
0
0
Ox 0
VIFx
22.6
95.0
GARAGE-C
c 3749
197
197
0
0
Ox 0
\AFx
25.1
95.0
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(Cfm)
Cig
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb2
Ox 0
787
787
72.2
0
1002
12.0
ox o
VIFx
Boh riitalk values have been manually overridden
w rightsoTt- 2020-Dea10 08:49:30
aM o.•,�,��,,. ,, •, N. Rio-Srito5 Uriversal 201019.0.21 RSUC8101 Page 1
XCA „risVrig}tsoR I NACIFINCH, WENDEC L & TERESA.rr{i Calc= W8 Frorr Door faros: N
FORM R405-2017
FLORIDA ENERGY EFFICIENCY
CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance
Method
ProjectName: WENDELL & TERFSA FINCH
BuilderName:
Street: 7991 PLANTATION LAKES DR.
City, State, Zip: PORT ST. LUCIE FL,
Permit Office: ST. LUCIF COUNTY
,
Owner: WENDELL & TERESA FINCH
PermitNumber:
Jurisdiction: 6611000
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (747.0 sgft)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 747.00 ft2
3. Number of units, if multiple family 1
b. NIA
R= ft2
4. Number of Bedrooms (Bedrms In Addition) 0(0)
c. NIA
d. NIA
R= ft2
5. Is this a worst case? No
10. Ceiling Types (792.0 sgft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade (ft2) 792
a. Roof Deck (Unvented)
b. NIA
R=20.0 792.00 ft,
Conditioned floor area belowgrade(ft2) 0
c. NIA
R= ft2
R= ft2
7. Windows(36.0 sgft.) Description Area
11. Ducts
a. Sup: Attic, Rot: Attic, AH: Attic
R ft2
a. U-Factor, Sgl, U=0.50 36.00 ft,
6 45
SHGC: SHGC=0.30
b. U-Factor. NIA ftz
12. Cooling systems
kBtuthr Efficiency
SHGC:
a. Central Unit
23.6 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
d. I}r: N/A ft2
13. Heating systems
kBtulhr Efficiency
SHGC: GG:
a. Electric StripHeat
15.2 COP:1.00
Area We]ghtedAverage Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems -Nonerequired
8. Floor Types (792.0 sqft.) Insulation Area
a.
Cap: NIA
a. Slab -On -Grade Edge Insulation R=0.0 792.00 ftz
b. Conservation features
EF: 2.24377F027
b. NIA R= ft2
c. NIA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.045 Total Proposed Modifies!
Total
Loads: 22.22
PASS
AS
Baseline
Loads: 22.35
I hereby certify that the plans and specifications covered by
this calculation
Review of the plans and
Jki$ 5T
are in compliance with the Florida Energy
specifications covered by this
Cade.
calculation indicates compliance,,,,r''•
y©�
PREPARED BY:
with the Florida Energy Code.
Before
_ _
DATE: 2-� a- za
construction is completed
_
this building will be inspected for'.
t7
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
WE
OWNER/AGENT:. - �.
BUILDING OFFICIAL:
DATE:
DATE:
�....
- Compliance requires certification by the air handler unit manufacturer
that the air handier enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1
and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2),
1211012020 9:16 AM EnergyGauge�D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
)RM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
WENDFLL & TERESA FINCH
Bedrooms:
0
Building Type:
User
ConditionedArea:
792
Address Type:
Street Address
OwnerName:
WENDFLL & TERESA FINCH
Total Stories:
1
Lot#
# of Units:
1
Worst Case:
No
Block/Subdivision:
BuilderName:
RotateAngle:
0
PlatBook:
Permit Office:
ST. LUCIE COUNTY
CrossVentilation:
No
Street:
7991 PLANTATION LA
Jurisdiction:
6611000
Whole House Fan:
No
County:
St. Lucie
FamilyType:
Single-family
City, State, Zip:
PORT ST. LUCIE ,
New/Existing:
Addition
FL,
Comment -
CLIMATE
DesignLocation
TMYSite
Design Temp
Int Design Temp Heating
Design Daily Temp
�—
97.5% 2.5%
Winter Summer Degree Days
Moisture Range
FL, Fort Pierce
FL_VERO_BEACH_MUNI
39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
792 7128
SPACES
Number
Name
Area Volume
Kitchen Occupants
Bedrooms InfiIID Finished
Cooled
1
GAR
792 7128
No 0
1 Yes
_Heated
Yes Yes
FLOORS
#
FloorType
Space Perimeter R-Value
Area Tile Wood Carpet
1
Slab -On -Grade Edge Insulation
GAR 83ft
0
792 ft2 -__-
0 1 0
ROOF
/
v #
Type
Roof
Materials
Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
Area
Area Color
Barr Absar. Tested
Tested lnsul. (deg)
1
Hip
Ftattile/slate 835 ft'
0 ft2 Medium
N 0.9 No 0.9
No 20 18.4
ATTIC
/
V
#
Type
Ventilation
Vent Ratio (1 in) Area RBS IRCC
1
Fulf attic
Unvented
0 792 ft2 N N
CEILING
#
Gelling Type
Space
R-Value Ins Type
Area Framing Frac
Truss Type
1
UnderAttic {Unvented) GAR
0 Blown
792 ft� 0.1
Wood
12/10/2020 9:16 AM EnergyGaugeS USA6.0.02 (Rev. 1) - FtaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Cavity Width Height
C�rnf To .—W,3]L y-pe Space 9 Sheathing Framing Solar Below
�-;{� .,, R—l_lue Ft ln,—.Ft In Areaa R ValUo—Eractinn Absor—GradeJ0
1 5E Exterior Concrete Block - Int Insul GAR 4.1 26 0 9 0 234.0 ft2 0 p 0.6 0
2 SW Exterior Concrete Block - Int Insul GAR 4.1 24 0 9 0 216.0 fif' 0 0 0.6 0
3 NW Exterior Concrete Block - Int Insul GAR 4.1 33 0 9 0 297.0 ft2 ❑ 0 0.6 0
DOORS
V # Omt DoorType Space Storms U Value Width Height
Ft In Ft In
1 NW Insulated GAR None .28 20 7
Area
140 f1x
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wail
Overhang
1/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade
1 SW 2 Metal Single(Clear) Yes 0.5 0.3 N 36.0 ft' 2 ft 0 in 1 ft 4 in None
Screening
None
INFILTRATION
# Scope Method SLA CFM 50 FLA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000286 594 32.61 61.33 .1039 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity _ _ Block
1 Electric Strip Heat/Existing eon None COP:1 15.16kBtulhr 1
Ducts
sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow_ SHFZ Block
1 CentralUnit/Exisfing/confirmed Split Single SEFR: 16 23.6 kBtu/hr cfm 0.9 1
Ducts
sys#1
SOLAR HOT WATER SYSTEM
FSFC
Cert # CompaRyName System Model# Collector Storage
CollectorModel# Area Volume
FEF
ft'
--
DUCTS
/ -- Supply-- --- Return — Air CFM 25 CFM25 HVAC #
Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool
1 Attic 6 45 ft' Attic 15 ft2 DefaultLeakage Attic (Default) c(Default) c 1 1
12/10/2020 9:16 AM EnergyGauge4D USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
ProgramableThermostat: Y Ceiling Fans:
Cooling Jan Feb M
Heating Jan
Venting Jan
Feb
Feb
ar
Mar
Mar
X
A r
Apr
May
May
Jun
Jun
X Jul
Jul
X Au
Aug
rX]
Sepp
Oct
Oct
Nov
Nov
Dec
— -
—
Apr
May
Jun
Jul
Aug
[[ ]15e
Se
Oct
Nov
Dec
Dec
ThermostatSchedule:
HERS 2 006
Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
—
10
11
12
Cooling(WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
80
80
80—
80
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
Heating (WEN)
AM
66
66
66
66
66
68
68
68
68
68
68
66
66
PM
68
68
58
68
68
68
68
68
68
68
68
Mass Type
Default(8 ibs/sq.ft.
68 68 68 68 68 66 66
MASS
Area Thickness FurnitureFraction Space
0 ftz 0 ft 0.3 - GAR
12t1012020 9:16 AM
EnergyGaugeg USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
_ S
AHRI Certified Reference Number: 201498260 �
Date : 06-29-2019 Model Status: Production Sto
Old AHRI Reference Number: 10206644 PPed
AHRI Type: RCU-A-CB
Series: GSX16
Outdoor Unit Brand Name: GOODMAN
Outdoor Unit Model Number (Condenser or Single Package) : GSX160241 F-
Indoor Unit Model Number (Evaporator and/or Air Handler) : ASPT33C14A"
MT,
Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, Ms,
Territories) NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, Rl, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S.
Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions
until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for
which they meet the regional efficiency requirement.
The manufacturer of this GOODMAN product is responsible for the rating of this system combination.
Rated as follows in accordance with the latest edition of ANSI/AHRf 2101240 with Addenda 1 and 2, Performance Rating of Unitary
Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing;
Cooling Capacity (A2) - Single or High Stage (95F), btuh : 23600
SEER : 16.00
EER (A2) - Single or High Stage (95F) : 13.00
t°Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced 'Production stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering for sale.
Ratin s that are accom anied by WAS indicate an involunta re -rate.
DISCLAIMER The new niibiished ratin is shown along with the previous i.e. WAS rating.
AHRI does not endorse the Product(s) listed on this Certificate and makes no representations. warranties or guarantees as to. and assumes no
unauthorized attetation of data listed on this Certificate. Certified ratings are valid only for models and responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
directory at www.ahridlrectory.org. configurations listed in the
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated;
entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual,
persona[ and confidential reference.
AM
CERTIFICATE VERIFICATION AIR-CONDITIONING. HEATrHa,
The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link & REFRIGERATION INSTITUTE
and enter the AHRI Certified Reference Number and the date on which the certificate was issued, we make life better -
which is listed above, and the Certificate No., which is listed at bottom right.
02019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132062832995120155