Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFO
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WENDELL & TERESA FINCH Builder Name: Street: 7991 PLANTATION LAKES DR. Permit Office: ST. LUCIE COUNTY City, Slate, Zip: PORT ST. LUCIE , FL, Permit Number: x Owner: WENDELL & TERESA FINCH Jurisdiction: 6611000 Lu Design Location; FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed, Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier, Windows, skylights The space between windowldoorjambs and framing, and and doors skylights and framing shall be sealed. Rtm joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation, maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the cravdspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall (,xignd behind piping aUd wiring, Showerltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tugs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids -between fore sDri9kIq.[ cover ylates and walls or i u „ uuI —T1, IE13peuilull u[ Icig Walls slid l WC Ili cluuulud#IL:C VVILII ihu pluvisiunb of ICC-400. 12/10/2020 9:17 AM EnergyGaugeO USA 6.O.D2 (Rev, 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12, Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 23.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Groundiwater source SEER/GOP 6. Conditioned floor area (sq. ft.) 6. 792 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.500 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.300 14. Heating system: Capacity 15.2 c) Area 7c. 36.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11, Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Fiarida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 7991 PLANTATION LAKES DR. Gity1FL Zip: PORT ST. LUCIE, FL 12/10/2020 91 T04 AM SnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 +�- wrightsoft� Project Summary Job: Entire House Date: Br• QUICK CALCS, INC. 317 ST_ LUCIE LANE, FT. PIERCE, FL 34946 Pho-:772-466-6799 Email: QUICKCALCS@AOL.COM For: WENDELL &TERESA FINCH 7991 PLANTATION LAKES DR., PORT ST LUCIE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 °F Outside db 70 'F Inside db 90 75 °F °F 28 °F Design TD 15 °F Daily range M Relative humidity 50 Moisture difference 61 gr/Ib Heating Summary Structure 13541 Btuh Ducts 1794 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 15335 Btuh Method Construction quality Fireplaces Area (ftZ Volume (T) Air changes/hour Equiv.AVF (cfm) Infiltration Simplified Average 0 Hea 792 Coo1791 7128 7128 0.61 0.32 72 38 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 4.4 kW Heating output 15157 Btuh Temperature rise 18 °F Actual air flow 787 c im Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Space thermostat Sensible Cooling Equipment Load Sizing Structure 13808 Btuh Ducts 1189 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 14247 Btuh Latent Cooling Equipment Load Sizing Structure 2388 Btuh Ducts 930 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3318 Btuh Equipment Total Load (Sen+Lat) 17565 Btuh Req. total capacity at 0.70 SHR 1.7 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160241F Coil ASPT33C14A AHRI ref 201498260 Efficiency 13.0 EER, 16 SEER Sensible cooling 16520 Btuh Latentcooling 7080 Btuh Total cooling 23600 Btuh Actual airflow 7$7 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.82 Calculafions approved byACCA to meet all requirements of Manual J 8th Ed. 2020-0ec-10 06:4a30 �� """"' """"`^'"'• �'• Right SutepLkwersa1241919.0.21 RSU08101 ...rlslWrighsofli-IUAC+INCH,VVENDELL&TERESA.rup Calc-MJ8 FrorlDoorfacesN Page +�- wrightsofi- Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. BY: 317 ST. LUCiE LANE, FT. PIERCE, FL 34945 Phone: 772-466-6799 Fmni�- ni urur� o Calculations aPProved b ACCA to meet all requirements of Manual J Sth Ed. �— wragFatsaYt� ght-SuteU Urnversaf 2019 19.0.21 RSU08101 2020-Dec-10 08:49:30 ...r%swFightsoft I-i5/AMPINCH, WENOELL & TERESA-rq) Ca1c= MJ8 Front Odor PaceS: N Page 1 wrightsoft® Duct System Summary ate: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Prone: 772-466-6799 Emaii: QUICKCALCS@AOL.COM For: WENDELL &TERESA FINCH 7991 PLANTATION LAKES DR., PORT ST. LUCIE. FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual air low Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 787 cfm 192 Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 787 cfm Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk GARAGE c 3749 197 197 0 0 Ox 0 VIFx 5.0 95.0 GARAGE -A C 3749 197 197 0 0 Ox 0 MFx 12.4 95.0 GARAGF-a c 3749 197 197 0 0 Ox 0 VIFx 22.6 95.0 GARAGE-C c 3749 197 197 0 0 Ox 0 \AFx 25.1 95.0 Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Cig (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb2 Ox 0 787 787 72.2 0 1002 12.0 ox o VIFx Boh riitalk values have been manually overridden w rightsoTt- 2020-Dea10 08:49:30 aM o.•,�,��,,. ,, •, N. Rio-Srito5 Uriversal 201019.0.21 RSUC8101 Page 1 XCA „risVrig}tsoR I NACIFINCH, WENDEC L & TERESA.rr{i Calc= W8 Frorr Door faros: N FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WENDELL & TERFSA FINCH BuilderName: Street: 7991 PLANTATION LAKES DR. City, State, Zip: PORT ST. LUCIE FL, Permit Office: ST. LUCIF COUNTY , Owner: WENDELL & TERESA FINCH PermitNumber: Jurisdiction: 6611000 DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (747.0 sgft) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 747.00 ft2 3. Number of units, if multiple family 1 b. NIA R= ft2 4. Number of Bedrooms (Bedrms In Addition) 0(0) c. NIA d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (792.0 sgft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 792 a. Roof Deck (Unvented) b. NIA R=20.0 792.00 ft, Conditioned floor area belowgrade(ft2) 0 c. NIA R= ft2 R= ft2 7. Windows(36.0 sgft.) Description Area 11. Ducts a. Sup: Attic, Rot: Attic, AH: Attic R ft2 a. U-Factor, Sgl, U=0.50 36.00 ft, 6 45 SHGC: SHGC=0.30 b. U-Factor. NIA ftz 12. Cooling systems kBtuthr Efficiency SHGC: a. Central Unit 23.6 SEER:16.00 c. U-Factor: NIA ft2 SHGC: d. I}r: N/A ft2 13. Heating systems kBtulhr Efficiency SHGC: GG: a. Electric StripHeat 15.2 COP:1.00 Area We]ghtedAverage Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems -Nonerequired 8. Floor Types (792.0 sqft.) Insulation Area a. Cap: NIA a. Slab -On -Grade Edge Insulation R=0.0 792.00 ftz b. Conservation features EF: 2.24377F027 b. NIA R= ft2 c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.045 Total Proposed Modifies! Total Loads: 22.22 PASS AS Baseline Loads: 22.35 I hereby certify that the plans and specifications covered by this calculation Review of the plans and Jki$ 5T are in compliance with the Florida Energy specifications covered by this Cade. calculation indicates compliance,,,,r''• y©� PREPARED BY: with the Florida Energy Code. Before _ _ DATE: 2-� a- za construction is completed _ this building will be inspected for'. t7 compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. WE OWNER/AGENT:. - �. BUILDING OFFICIAL: DATE: DATE: �.... - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2), 1211012020 9:16 AM EnergyGauge�D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 )RM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WENDFLL & TERESA FINCH Bedrooms: 0 Building Type: User ConditionedArea: 792 Address Type: Street Address OwnerName: WENDFLL & TERESA FINCH Total Stories: 1 Lot# # of Units: 1 Worst Case: No Block/Subdivision: BuilderName: RotateAngle: 0 PlatBook: Permit Office: ST. LUCIE COUNTY CrossVentilation: No Street: 7991 PLANTATION LA Jurisdiction: 6611000 Whole House Fan: No County: St. Lucie FamilyType: Single-family City, State, Zip: PORT ST. LUCIE , New/Existing: Addition FL, Comment - CLIMATE DesignLocation TMYSite Design Temp Int Design Temp Heating Design Daily Temp �— 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 792 7128 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled 1 GAR 792 7128 No 0 1 Yes _Heated Yes Yes FLOORS # FloorType Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation GAR 83ft 0 792 ft2 -__- 0 1 0 ROOF / v # Type Roof Materials Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Area Area Color Barr Absar. Tested Tested lnsul. (deg) 1 Hip Ftattile/slate 835 ft' 0 ft2 Medium N 0.9 No 0.9 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fulf attic Unvented 0 792 ft2 N N CEILING # Gelling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic {Unvented) GAR 0 Blown 792 ft� 0.1 Wood 12/10/2020 9:16 AM EnergyGaugeS USA6.0.02 (Rev. 1) - FtaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height C�rnf To .—W,3]L y-pe Space 9 Sheathing Framing Solar Below �-;{� .,, R—l_lue Ft ln,—.Ft In Areaa R ValUo—Eractinn Absor—GradeJ0 1 5E Exterior Concrete Block - Int Insul GAR 4.1 26 0 9 0 234.0 ft2 0 p 0.6 0 2 SW Exterior Concrete Block - Int Insul GAR 4.1 24 0 9 0 216.0 fif' 0 0 0.6 0 3 NW Exterior Concrete Block - Int Insul GAR 4.1 33 0 9 0 297.0 ft2 ❑ 0 0.6 0 DOORS V # Omt DoorType Space Storms U Value Width Height Ft In Ft In 1 NW Insulated GAR None .28 20 7 Area 140 f1x WINDOWS Orientation shown is the entered, Proposed orientation. / Wail Overhang 1/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade 1 SW 2 Metal Single(Clear) Yes 0.5 0.3 N 36.0 ft' 2 ft 0 in 1 ft 4 in None Screening None INFILTRATION # Scope Method SLA CFM 50 FLA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000286 594 32.61 61.33 .1039 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity _ _ Block 1 Electric Strip Heat/Existing eon None COP:1 15.16kBtulhr 1 Ducts sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow_ SHFZ Block 1 CentralUnit/Exisfing/confirmed Split Single SEFR: 16 23.6 kBtu/hr cfm 0.9 1 Ducts sys#1 SOLAR HOT WATER SYSTEM FSFC Cert # CompaRyName System Model# Collector Storage CollectorModel# Area Volume FEF ft' -- DUCTS / -- Supply-- --- Return — Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 45 ft' Attic 15 ft2 DefaultLeakage Attic (Default) c(Default) c 1 1 12/10/2020 9:16 AM EnergyGauge4D USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Cooling Jan Feb M Heating Jan Venting Jan Feb Feb ar Mar Mar X A r Apr May May Jun Jun X Jul Jul X Au Aug rX] Sepp Oct Oct Nov Nov Dec — - — Apr May Jun Jul Aug [[ ]15e Se Oct Nov Dec Dec ThermostatSchedule: HERS 2 006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 — 10 11 12 Cooling(WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 80 80 80— 80 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 Heating (WEN) AM 66 66 66 66 66 68 68 68 68 68 68 66 66 PM 68 68 58 68 68 68 68 68 68 68 68 Mass Type Default(8 ibs/sq.ft. 68 68 68 68 68 66 66 MASS Area Thickness FurnitureFraction Space 0 ftz 0 ft 0.3 - GAR 12t1012020 9:16 AM EnergyGaugeg USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 _ S AHRI Certified Reference Number: 201498260 � Date : 06-29-2019 Model Status: Production Sto Old AHRI Reference Number: 10206644 PPed AHRI Type: RCU-A-CB Series: GSX16 Outdoor Unit Brand Name: GOODMAN Outdoor Unit Model Number (Condenser or Single Package) : GSX160241 F- Indoor Unit Model Number (Evaporator and/or Air Handler) : ASPT33C14A" MT, Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, Ms, Territories) NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, Rl, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRf 2101240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing; Cooling Capacity (A2) - Single or High Stage (95F), btuh : 23600 SEER : 16.00 EER (A2) - Single or High Stage (95F) : 13.00 t°Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced 'Production stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratin s that are accom anied by WAS indicate an involunta re -rate. DISCLAIMER The new niibiished ratin is shown along with the previous i.e. WAS rating. AHRI does not endorse the Product(s) listed on this Certificate and makes no representations. warranties or guarantees as to. and assumes no unauthorized attetation of data listed on this Certificate. Certified ratings are valid only for models and responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the directory at www.ahridlrectory.org. configurations listed in the TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, persona[ and confidential reference. AM CERTIFICATE VERIFICATION AIR-CONDITIONING. HEATrHa, The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link & REFRIGERATION INSTITUTE and enter the AHRI Certified Reference Number and the date on which the certificate was issued, we make life better - which is listed above, and the Certificate No., which is listed at bottom right. 02019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132062832995120155