Loading...
HomeMy WebLinkAboutProduct Approval; Roof Deck Structural Componentsr x p t Ak,:r ro{) 7' (r� r ftM7lJ �S ti #r Ali SCISHome lag in UstrReglstradon' HotTapics 5ubft5wd.,ge SUtg&Fads I PubllcatWasContactus aCISSIteMap Unlrs Search Florida n r, Product Approval a USER! Publle User Product Aoprovai Menu > Product or Aopilddon Seacd» AWkjuan Ust> Applfgtfon Oatall. RECEIVED ;.•ar . y Fl- FL27402-RL . Application.Type Revision NOV 112020 Code Version 2017 Application Status Approved Permitting Department St. Lucie County Comments Archived Product Manufacturer carpoitsAnywhere Address/Phone/Email 10858 S..E. County Road 221 REVIEWED FOR Starke, FL bodom carpo6 ��DE, com LIANCE bodom@carportsanywhe o �a ST'. LUCIE COUNTY Authorized Signature Brendle Odom ® bodom@carportsanywhere.com ®®V C Technical Representative Address/Phone/Email Quality Assurance'Representative Address/Phone/Email FILE Category Structural Components m" y Subcategory Roof Deck Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Terrence E. Wolfe Evaluation Report Florida License PE-44923 Quality Assurance Entity PRI Construction Materials Technologles, LLC Quality Assurance Contract Expiration Date. 06/23/2023 Validated By Brian Saks, P.E. Validation Checklist Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27402 R1 COI Letter of Certification.pdf Standard Year ASTM E 1992 2005 FM 4471 1992 Product Approval Method Method 1 Option D Date Submitted 08/08/2019 Date Validated 08/09/2019 Date Pending FBC Approval 08/26/2019 Date Approved 10AS/2019 Contact U :: 2601 Wall; Stone Road, Tallahassee FL 32399 phone: 850.07-1824 The State or Florida Is an AA/EEO employer. Coovrloht 2007-2013 State of Florida.:: Privacy Statement :: Accossiblllty StatemenC :: Refund Statement Under Florida law, email addresses are public records. If you do not want youre=mall address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail, If you have arty questions,please contact 850AB7.1395. -Pursuant to Section 455.275(1); - Florida Statutes, effective October 1, 2012, licensees licensed under Chapter'455, F.S. must provide the Department with an email address If they have one. The email% provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please. provide the Department with an email address which can he made available to the public. To determine If you are a licensee under Chapter459, F.S., please dick hqre . Prod_ uct Approval Accepts: r--��w Credit Card Safe Force Engineering & Testing. Inc. 19530 Ramblmood Drive Humbl ,77C 77338 Product Evaluation deport CARPORTSANYWHERE Hampton Rib R®of Pdnel over open firaao ing_ Florida Product Approval # 27402.1 R1 Florida Building Cade 2017 Per Rule 61G20-3 Method: l —D Category: Structural Components Subcategory: Roof Deck Compliance Method: 616203.005(1)(d) NON HVHZ Product Manufacturer: Carport Anywhere 108S8 S.E. County Road 221 Starke, Florida32091 Engineer Evaluator: Terrence E. Wolfe, P.E. 944973 Florida Evaluation ANE IM 1926 Validator: Brian Jaks, P.E. 4701S9 Contents' Evaluation Report. Pages 1-4 CENSs4e i. No. 40e b' SrAYE OF OR 11) FL# 27402.1 RI August 8, 2019 UForce Engineciing & Testing Inc.. . U 19530 Rdmblewood Drive Humble,TX 77338 Compliance Statement: The product as.described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2,1504.7: Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel,-ASTM A792 orASTM A653 690 Grade 50 29 Ga. Steel, ASTM A792 or ASiM A653 690 Grade 80 Conforming to Florida Building Code 2017 'Section 1507.4.3. Optional paint finish. Corrosion Resistance: Panel Material shall comply with.Fiorids Building Code 2017, Section 1507.4.3. Panel Dirdension(s)i Thickness: 26 Ga.:0.0185" min. order thickness 29 Ga.:0.0142" min. order thickness Width: 36" maximum coverage Rib Height: VVmajor rib at9"O.0 Panel Rollformem MRS Metal Roliforming Systems Panel Fastener: 912-14.x °Y." HWH SDg3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4.4. Substrate Description: Minimum 14 Ga. (Grade.50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Go. (Grade SO) Steel framing: See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: , 5'-0" O.C. 4'-0" O.C.. 4'-01 ox. 5'-01 O.C; 4'-V O.C. Substrate: Min.14 Ga. Steel Framing Min.14 Go. Steel Framing Min.18 Ga.. Steel Framing Min.19 Ga. Steel Framing Min. Is Ga. Steel Framing ve5%n rreSSUTe mquoes a Safety Factor= 2.U. {111rl4rfl, i C E NSF. ` No. 48Z9 STATE OFID p► 44`�� ORAL 10 FL# 27402.1 Rl August 8,- 2019 a Porce.Engineering& Testing Inc. . 19530 Rmnblewood Drive Humble,'TX 77338 Maximum Design Pressure: -57.3 psf -150.9 psf +39.0 psf +143.1 psf Fastener Fattem: 6"4"-6"-3" 6"-3"-6" 6"-3"-6"-3 6"3" fl' . 6"-3" 6"-3"-6"-3" 6" 6"4"4`4.'0-3`-6" FastenerSpacing: 4' 0 O.G.. Y 0" O.G 4'-0" O.C. 2'-0" O.G Substrate: MIn.16 Ga. Steel Framing Min.16 Ga., Steel Framing Min.16 Ga: Steel Framing Min.16.G; Steel framing - .+car�rcamc mciuues a aa:ery raaor=e.v. _ ' , . , Code Compliance:.. The product described herein has demonstrated compliance with The Florida Building Code 2017, Sectian'1504.33,1564.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61G203. Performance Standards: The product described herein has demonstrated compliance with: ■ ASTNI E 1592-05 (1012) Test method for structural performance of sheet metal roof and sfding,systems by uniform static air pressure difference ■ FM 4471-92 -Foot Traffic Resistance Test Reference Data: 1. .ASTIVI E 1592-05 (201Z) Test Force Engineering & Testing, Inc. (FBCOrganization # TST 5328) Report No. 667-0060T 18A-E, 667-0061T-18A-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test ..Force Engineering &Testing,,Inc. (FBC Organization # TST-5328) Report No. 667-0060T 18F, 667-0061T-18E 3.Certificate of Independence By Terrence E. Wolfe, P:E: '(No.44923) @ Force Engineering & Testing, Inc. (FBC Organization# ANE ID:1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92, Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20.-3.005 (3) for FL# 27402.1 R1 41 'If STATE OF J seu Adri. ��� SS 0 arm Ilf{: �`, August 8, 2019 rForceEntgineering &:Tcs�ting Inc. 19530 RimblewooAve Humbtc,77C 77338 manufacturing under quality assurance program audited by an approved - quality assurance. entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, Including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12; lap sealant must be used in the panel side laps. Installation: Install per manufacturers recommended details. Insulation: Manufacturers approved product (Optional). .Roof Panel Fire Class cation: fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions ofthe structure, appropriate wind loads are. determined using.Chapter 16 of the Florida Building Code 2617 for roof cladding Wind, loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings.for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Cad .e2017 Chapter 22 forsteel, and Chapter.16 for structural loading. �aflflr�r�r ♦♦��,E 1%C E� -F.. jy,,fix i `��• �' 499� .' STATE OF ; FL# 27402.1 Rl August S, 2019 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 12-14 x 3/4- HWH 503 V//'14PAM.80NOE0 NEOPRENE V/ASf1LR 29'Gk. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3"-6"-3"-6" 6 3.. R. 3. 6. 3• r. 3" }� c /112-14 x 3/4" HWH S03 W/ 14MM. OONOEO NEOPRENE WASHER 6IM of FloddO C.O.A. awns 1p �Q�Q Ng`.0 Flo.44923 '.x , '• STATE OF %,,oS,s R l0 , q�� �0N't``\\```` [ 111\ August 8, 2019