Loading...
HomeMy WebLinkAboutProduct Approval; SwingingExterior Door Assembliesa uw l a Florida Eluding Code Unline r aCIS Home I Log In I User Registration I HotToples I Submit Surcharge I Stats & Facts- I Publications I Contact Us 1, BUS Slte Map, I Unks I Search, I Florida . (L, "mil Product Approval p USER, Pubilc User Praduct Aooroval Menu > Product or Aofillcation Seare:h•> Application Ust> Application Detail FL #, FL15225-114 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the'Commission if necessary. Comments Archived Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive "Edgerton, OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com. Authorized Signature 'Vivian Wright rickw@rwbidgconsultarimcom Technical" Representative Address/Phone/Email Quality Assurance Representative.. Address/Phone/Email Category '. 'Exterior Doors . Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute validated By Ryan J. King, P.E. Validation Checklist r Hardcopy Received Referenced,Standard and Year (of .Standard) Standard Year 101/I.S.2 1997 ASTM E1886 2002 ASTM P-1996 2002 ASTM E330 2002 TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or. Architect FL15225 R4 EaWy_(g),€qu va a cy of Standards.odf Product Approval Method Method' 1 Option A https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZIQRASQx6OG%2b2JlO2u6xAbaUKJ!jphgF6ilTIA%3d%3d 113 o, ucv:v 1-Iona tsullding:Code Online Date Submitted 09/21/2017 Date Validated 12/20/2017 Date Pending FBC Approval Date Approved 12/22/2017 Summary of Products FL # Model, Number or Name Description i5Z25.1 a. "Classic -Craft" and "Benchmark by .6/8 and 8/0 Opaque and Glazed Fiberglass Door with and Thermo Tru" without Sidelites. Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLI5225 R4 C CAC 15225.1 NAMI certs.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 Design Pressure: N/A Installation. Instructions Other: See INST 15225.1-68 (6'8 Door Products), INST FLI5225 R4 II (a) Inst 15225.1-68.pdf 15225.1-80 (8'0 Door Products) and INST 15225-68M (6-8 FL15225 R4 It (a) Inst 15225.1=80.pdf Door Products Direct to Masonry) for installation Instructions: FLI5225' R4 IT '(a) Inst 15225•68M.pdf . (Note - Glazing Shall comply with ASTM E3300-04) FL15225 R4 II. FL-15225.1 Glazing Det..odf Verified By: Lyndon F. Schmidt, P.E-43409 Created by Independent Third Party: Yes Evaluation Reports . FLI5225 R4 AE '(a) EV6I 15225.1-68.pd FLI5225 R4 AE (a) Eval 15225.1-80.pdf FLI5225 R4 AE' (a-)-Eval 15225-68M.pdf Created by Independent Third Party: Yes 15225.2 b. "Construction Series" and 6/8 Opaque Steel Door with and without Sidelites. Inswing and "Benchmark by Thermo Tru" Outswing Limits of Use Certification Agency Certificate Approved for. use In HVHZ: No FL15225 .114 C CAC 15225.2 NAMI certs pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2021 Design Pressure: N/A Installation Instructions Other: See INST 15225.2-68 (6'8 Door Products) and INST FLI5225 R4 II (a)_ Inst 15225.2-68.pdf .15225-68M (6'8 Door Products Direct to Masonry) for FLI5225 R4 II (a) Inst FL45225-68M-AAdf Installation instructions. (Note- Glazing Shall comply with FLI5225 R4 II FL-15225.2 Glazing Det..pdf ASTM E1300-04) Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FLI5225 R4 AEA) Eval 15225:2-68.odf FL15225 R4 AE (a)_FL-15225-68MA.pd Created by Independent Third Party: Yes 15225.3 c. "Fiber -Classic" and "Benchmark by 6/8 and 8/0 Opaque and Glazed Fiberglass Door with and Therma-Tru" without Sidelites. Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FLI5225 114 C CAC .15225 3 NAMI certs ndf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date impact Resistant: No 12/31/2021 Design Pressure: N/A Installation: Instructions Other: See INST 15225.3-68 (6'8 Door Products), INST FL15Z25 R4 II (a) Inst 15225.3-68.pdf 1S225.3-80 (8'0 Door Products) and INST 15225-68M (6'8 FLI5225 R4 II (a) Inst 15225.3=80.pdf Door Products Direct to Masonry) for installation instructions. FLI5225 R4 II (a)_Irist 15225-68M.pdf Note - Glazing Shall comply with ASTM E1300-04. (This product FLI5225 R4 II FL-15225.3 Glazing D- et..pdf approval requires the use of "P' part number doors, and . . Verified By: Lyndon F Schmidt, P.E. 43409 sidelites, which have been stained or painted within 6 months Created by Independent Third Party: Yes of installation - Excludes Opaque Benchmark Door Panels.) Evaluation Reports FLIS225'R4 AE (a)_Eval15225.3-68.odf FLI5225 R4 AE (a) Eval 15225.3-80.pdf FL15225 114 AE (a) Eval 15225-68M.pdf Created by Independent Third Party: Yes 15225.4 d. "Premium Series" and "Benchmark 6/8 and 8/0 Opaque Steel Door with and without Sidelites. by Thermo Tru" Inswing and Outswing Limits of Use Certification Agency Certificate Approved for use in HVHZ: No 1`05225 R4 C CAC 152�5 a Nnnnr'�art� Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2021 Design Pressure: N/A Installation Instructions Other: See INST 15225.4-68 (6'8 Door Products), INST FLI5225 R4 II (a) Inst FL-15225-68MA.pdf 15225A-80 (8'0 Door Products) and INST 15225-68M (6'8 FLI5225 R4 II (b) Inst 15225.4-68.pdf boor Products Direct to Masonry) for installation Instructions. FL15225, R4 II fb) Inst 15225.4-80.pdf (Note - Glazing Shall comply with ASTM E1300-04) FL15225 R4 II FL-1 5225.4 Glazing Det..pdf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Evaluation Reports FLI5225 R4 AE (a) FL-15225-68MA.pdf https://www.floridabuilding:orgfprlpr app dtl.aspx?param=wGEVXQwtbgv3yWKJZlQRASQx6OG%2b2JI02u6xAoauKJijphgF6uTlA°/a3d%3d 2l3 a licu la Florida Building Code Online FL15225 R4 AE (b Eval 15225.4-68.od� FL15225 114 AE',(, Eval 1S225A-80.0df Created by Independent Third Party: Yes 15225.5 ITherrila-Tru" e. "Smooth -Star" and "Benchmark by 6/8'and 8/6 Opaque•and Glazed Fiberglass. Door with and without Sidelites. Inswing and Outswing. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FLIS225 R4 C GAG 15225.5 NAMI:certs.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2021 Design pressure: N/A Installation Instructions Other: See INST 15225.5768 (6'8 Door Products), INST FLIS225 R4 II (a)_Inst 15225.5-68.pdf 15225.5-80 (8'0 Door Products) and INST15225-68M (6'8 . FL15225 R4 II {a) Inst-15225.5-80.pd . Door Products Direct to Masonry). for Installation Instructions. FL15Z25 R4 II • (a) Inst 15225-68M.odf, Note : Glazing.Shall comply with ASTM E1300-04. (This product 'FL15225 .R4 II FL-15225.5 Glazing Det:.odf approval requires the use of "J" part number doors and Verified By: Lyndon F. Schmidt, P.E. 43409 sidelites, which have -been stained or painted within 6 months Created by Independent Third Party: Yes of installation - Excludes Opaque Benchmark Door Panels.) Evaluatlon Reports FL15225 R4 AE (a) Eval 15225.5-68.od� FL15225' R4 AE' {a) Eval 15225.5-80.0dif ' FLIS225 R4 AE (a) Eval 15225-68KIldf Created by Independent Third Party.: Yes 15225.6, f. "Premium Series", "Construction 6/4 and 8/0 Opaque and Glazed Steel Doorwith•Traesoms. Series" and "Benchmark by Therma- With and without Sidelites. Inswing and Outswing Tru" with Transoms Limits of Use Certification Agency Certificate _ Approved for use in HVHZ:. No FL15225 •R4 C CAC 15225.6 NAMI certs.odf . Approved foe. use outside HVHZ: Yes QualityAssurance Contract Expiration Date. Impact Resistant: No 12/31/9021 . . Design Pressure: N/A Installation Instructions Other: See INST.15225.6-68 (6'8 Door- Products) and FLI52Z5 R4 II (a) Inst 15225.6-68.odf 15225.6780 WO Door Products) for installation instructions.. FLIS225 R4 II (a) Inst 15225.6-80:Ddf (Note'- Glazing.Shail comply with ASTM E3300-04) FL15225 R4 II FL-15225.6 Glazing Det..odf Verified By: Lyndon R.-Schmidt, P.E. 43409 Created by. Independent Third Party: Yes Evaluation Reports FL15225 R4 AE (a) Eval 15225:6-68.edf FLIS225 R4 AE (a) Eval 15225.6-80.Ddf. Created by Independent Third Party: Yes r3acic :ve;;t .. Contact Us :: 2601 Blair Stone Road, Tallahassee FL32399 Phone: 8so-487-1R24- The State of. Florida is an AA/EEO employer. ggapyd ht 2007-2013 State of Florida;:: PrIVdN Statement :. Accessibility Statement::, Refund Statement Under Florida law, email addresses are public records; If you do not wantyoure-mail address released In response to a publk-records request, do not send electronic mall to this entity. Instead, contact the'office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section 455,275(1), Florida Statutes,.effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Departmentwlth an email address If they one. The emalls provided may be used for offlclal communication with the licensee' However email addresses are public record. If you do not wish to supply a'personal address, please provide the Department with an email address which cen.be made available to the public. To determine if you.are a.licensee under Chapter 455, F.S., please dick here . Product' Approval Accepts; Ri•�i Credit Safe securitym Eriucs https:IANww.floddabuilding:orgfprlpr_app_dtl.aspx2param=wGEVXQwtDgv3yVVKJZ1QRASQx6OG%2b2JI02u6xAoauKJijphgF6uTIA%3d%3d 3/3 ® T.H-ERMA ITRU 105.50" MAX, OVERALL FRAME WIDTH --�{ 68.50'' MAX, OVERALL WIDTH 7 � = THERMA TRIJi. OOOR5 118 INDUSTRIAL DR.. EDGERMN. DH_43517 4 r�, n n Classic-Craft > 4 I 1lI, "i ' J 1l }7 _4 1,'I , '' 6'8" SINGLE AND DOUBLE OPAQUE OR GLAZED PANELS - 5 5 �'• I� �( II Fr� r� �I 1� 5 �I 1� O �I 1� �1 1( W/ & W/OUT SIDELITES INSWING /OUTSWING 1 `� ' `� `�"' JJ INSULATED FIBERGLASS DOOR WITH WOOD FRAMES R P P P General Notes 1. This product anchoring drawing has been developed in compliance with the 6th Edition .(2017) Florida Building Code (F8C) excluding the "High Velocity Hurricane Zdne'. See the Certification Agency Certificate for sizes, specifications and ratings. 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing, stucco, foam, brick and other wall coverings. 3. Wood screws shall be installed following installation instructions of ANSVAF&PA NDS 2015. . All other fastener types to be installed following fastener manufacturers installation instructions. 4. Fastener embedment depths, edge distances and center -center distances shall be as, specified by the fastener manufacturer but in no instance shall they be less than shown in this drawing. 5. Where shims are used, they must be a'tigid I stiff' material that complies with the requirements of the FBC. 6. Positive and negative design pressure requirements for use with this drawing shaft be determined by others for specific jobs in accordance with the governing code. 7. Site conditions not covered by this drawing are subject to further engineering analysis. TABLE OF.CONTENTS SHEET# DESCRIPTION I Typical elevations, design pressures & general notes 2 Buck anchoring 3 Frame anchoring 4 Frame anchoring & bill of materials 5 Horizontal &vertical cross sections 6 Vertical cross sections DOUBLE W/ SIDELITES OXXO MAX DESIGN PRESSURE +47.0 =47.0 SINGLE IV/ SIDELITES OXO MAX DESIGN PRESSURE +47.0 -47.0 37.50" MAX. OVERALL WIDTH I 74.50" MAX. - OVERALL WIDTH 1 2 3 4 ~s 1 I 110 4 4 O.H. > VI 5 0= I 1. ,I I, ,1 1, 1 1 I 1 5 5 I I 1' 1( I, 1 1 1 1 1, 1, 5 w 5 eL 31 L_y 5 5, o:H, ,I ,} �A j ,1. ` mil 5 5 5 SINGLE X DOUBLE XX ' MAX DESIGN PRESSURE MAX DESIGN PRESSURE +77.0 -77.0 +47.0 -47.0 - LOCK HARDWARE MFG & SERIES KWIKSETSIGNATURE SERIES iATCH KWIKSETSIGNATURE SERIES 780 OEAD00LT 53Z MAX. OVERALL WIDTH b� Ft r--P. f I I 1 1 I 1 I 1 L'_'1J I� r L SINGLE W/SIOELITE OX MAX DESIGN PRESSURE +47.0 -47.0 STALE; N.T.S. . Mr. Br.. JK CHK: BT: :LFS 0"Ma. Wa FL— 15225.1-68 R:\Cllents\Therma Tm PERMANENT\A - Florid. Product Approwls\FL-15225 Cm Mark - Install Only\C - Drawings\FL-1S225 (2017)\FL-1522S.Ldwg, 2 p, N t - o�3oaoO '_ Q•O C ro P W n m 4. OR, r^i-' x M Fail MO MN � D-0 o c^ n 3' $msz '^ c x c0a?� Qa>tp'Qoo= � W a IO O p 214 m Q:0) Z••- �-C m a. �a o'o n z �x 3 —� = 911 ca o� S a a 15.15" MAX. I I 4„ 0 03 m O.C. (TYp.)-tI ^ o m 33 o S x ve, C> stG{ C ryryrya c Z z tmD 7O m x C){ ,oaf X v Do m zz- a zz EP=m LDS A ;�t rn 1P� z = c •n0r- i x O mz0 Z a0 + co in zm m� o 1 D Z- --------__ — mF o z A m z °: 18.94" MAX. 11 f� I 4° c7 O.C. (TYP.) 0 ,1 ra mi3 ro x my co z C) z -1 C) 18.W MAX. O.C. (TYP.)r- x m0 taroN x - - - - - - - - - - av LO -T - cza A _ mxc: m0r- -------- �v----- m=c rz T------- m z m -n — mm=K z0 mm c a - r7 m mZz 0� rn m cci m o ------ - -=-------------- - - - - - - - - x � z:E r, 05 m 01 � 15.94" MAX. z_ m*l o 50 m i c ? O.C. (TYp.) 4 r- e mz0 m� z ,I vZ rn 1O.8.94" MAX. C. (TYP.) -1^7 2 9 27 17 UPDATE TO 8TH ED. 2017 FBC LFS - 1 2 OS 15 UPDATE TO 5TH ED.` 2014 FBC LFS NO DATE - BY z � to I' y N / Mw v , No.43409 -:` S0AI0mber21.2D17—.flfl- T: Oecu—r o Prepared Sys i Lyndon F. Sohmldt ii �" /ICA.....� ' THERMA-TRU FIBERGLASS DOOR P.E. No. 43409 /f�NALty;� 2 ASSEMBLY:. GDBUILDING CONSULTANI9, INO. BUCK ANCHORING P.O. Box 230, Voldco, 'FL 33595 Phone No.: 813.659.9197 FBPE C.A. No. 9813 i D,. "E„ "C" 4rJ�-�—J I--3,.I I I MULLION IIE SHOWN FOR ;�� - REFERENCE A W/2X BUCK INSTALLATION - - 9 W/1X BUCK INSTALLATION - TYP, HEAD &JAMBS - o , p "C" D" "E" VIEW "C"-"C" SINGLE DOOR W/SIDELITES „C„ "D" A„ ��^ o IN - PAIRS 30. TYP. `a 3 TYR. T OR -- L ~ LU W ¢ W I ? W m = Q U EZ w uD 0 C.1 ^O . Tl O J uJ SEE W DETAIL "4" `o SEES DErar� N � VIEW "E"-"E" ^ VIEW SHOWN W/ OPTIMA CORRUGATED FASTENERS, MEM 130 OV. ALL SIEUTE TO DOOR JAN9 EON MONS) SIDEUTE NOTES: 1. The sidelite is direct set into the jamb with (12) q8 x2" pfh. wood scram, there are (4) at each vertical Jamb, from the top down at US, 31 ", 48.6" & 66 There are (2) of the header at 4" from the outside comers of the frame. There are (2) at the sill, 4" from the.oulside comers. 2. For optional sidelite construction with staples, sidelite is direct set Into the jamb w(fh (4)/6"X I?/4 ' 16 ga. staples along each jamb (6" from ends and equally spaced thereafter). CONCREMANCHOR NOTES: 1. Concrete anchor locations at the comers maybe adjusted to maintain the min. edge distance to mortar joints. 2. Concrete anchor locations noted as MAX. ON CENTER must be adjusted to maintain the min. edge distance to mortar joints additional concrete anchors may be required to ensure the MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: 'ANCHOR ANCHOR' lNIN; :MIN. CLEARANCE MIN, CLEARANCE :• TYPE,, SIZE EMBEDMENT TO• MASONR.Y TO ADJACENL .:... , EDGE ANCHOR. . ' ITW ® 2" 4" TAPCON ITW TAPCON® 3/16" 1.1/4" 3" N wa )R Q E - � ATION of ATION V� U ^ CI L vi - SEE DETAIL "2' INSTALLATION wIX BUCK _ V1 INSTALLATION to Cl TYP. HEAD & o JAMBS z 0 Frtr 1tEE ,, d'mZ • 9 Y aZU � m m S 4 m c �Z rL o' SEE "D" A„ V A" SINGLE DOOR W/SIDELITE VIEW "B"-"8" SINGLE DOOR VIEW A A" 0 B QUAIL "6" W/2X BUCK 2 INSTALLATION, O. W/1X'BUCK INSTALLATION DETAIL "2 W/2X BUCK INSTALLATION2 B W/1X BUCK INSTALLATION 12 7 C 1 C DETAIL "I' DETAIL '4' PW -ft JK m :NK art. LFS DRAWING NO.: FL-15225.1-68 0 RHEA _�L OF 6 N s to J- i O �r d VIEW "C"-"C" 3_, LJL I 3 I 4f 3" 7�-'; . I_ II I I II I I II SEE NOTE 311 II _ SHEET 3 II SEE DETAIL "3" II �I II MULLION ASTRAGAL-' SHOWN FOR B SHOWN FOR _ REFERENCE If REFERENCE _ ONLY 0 u _ 16 Ifi6I A1216 5 II 5 L_ "E" DOUBLE DOOR WISIDELITES ic IN PAIRS 30 �^ _ of A" Q,. JTY� 6"U . z %INSTALLATION W/2X BUCKSEEDEfA1LINSTALLATION of II W/2X BUCK A W/1X BUCK v 3INSTALLATION �` w¢ 2 / W/1X BUCK g o w (ry\l1 & J HEAD a w = ASTRAGAL (INSTALLATION 4 �? $ N \ j & JAMBS iv SHOWN FOR IITYP. HEAD' & •- of \v'i L- - - REFERENCE II JAMBS' _ ONLY II _ 1 IF " SEE _ DETAIL. "4- a o _ II SEE 16 II 16 DETAIL o I i6 a En 12 II. If e1 ,A" VIEW "E"-"E" DOUBLE DOOR VIEW sHOWN w/ DenomL CORRWATEn iAVENERS, M 130 (rw, AM SIDW M TO DOOR .W/S CCNNECRONS) - W/2S( BUCK 2 INSTALLATION W/1X BUCK INSTALLATION 12 1 C W/2X BUCK Item DESCRIPTION Material ;F 10 x 2-1 2 PFH WOOD SCREW STEEL EF #10 X 1-3 4 PFH WOOD SCREW STEEL C TO X 1 PFH WOOD SCREW STEEL 1 10 x 3 4 I.G. PFH WOOD SCREW Hine to Frome STEEL 2 #10 x 2" LG. PFH WOOD SCREW STEEL 3 S x 2-1 2 LG. PFH WOOD SCREW STEEL 4 1 4" x 2-3 4" PFH ELCO OR ITW CONCRETE SCREW STEEL 5 1 4" x 1-3 4"ITW PFH CONCRETE SCREW STEEL 9 1 4" x 3-3 4" ITW. PFH CONCRETE SCREW STEEL 11 3 16" x 3-1 4"ITW PFH CONCRETE SCREW STEEL 12 1 4" x 3-1 4" ITW PFH CONCRETE SCREW STEEL 13 MASONRY - 3000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 16 1 4" X -1/4" PFH ITW CONCRETE SCREW STEEL 20 HEADER JAMB SUGAR PINE SG >= 0.34 WOOD 27 3 4" THK. PRESSURE' TREATED SIDELITE PAD WOOD 30 1 2" X 1" X 25 GA. CORRUGATED FASTENER STEEL INSTALLATION 3 1 W/1X BUCK 11 0 DETAIL "I INSTALLATION DETAIL 3" ATTACH ASTRAGAL THROW BOLT B STRIKE PLATE TO FRAME 1 C 1 DETAIL "4' AS SHOWN. n �j cmw `� F n co \\\ n a mz U C4 u gores p oa N"a makT oZ 9 coi 3d O p� IMF 2/21 12 12 N.T.S. c er JK m Dr: LFS 3 N 15225.1=68 c 4 of-6 N Wfients\Therma Tru PERMANENTVI- Florida Product ApprovalslFL-1522S Celt Mark - Install OnW - Drawings\FL-15225 (2017AFL-15225.1.dwg, 5 3p m �'Ptr' 9�O vZ X at s m m � > .� I s1 . p Im N o z y Im I y�yN 2- 9.27 77 UPDATE TO.6TH ED. 2017 FBC Lf5 1 .2 05 T5 UPDATE TO 5TH ED. 2014 .FBC. LFS NO. I - BY X Z c C) 0 I- l7 Cr n no, y� o, .75 a , 25'MAXSIMSPACE: 1.W MI 4 MAY H aN O A s T. > �m Im0.1sMIH._ — CSINK � 0.25'MAX. X A Z to 0 Tls W •. =ox > SHIMAx. SMSPACE 1.13' MIN, EMB. 1.?S'MIN. EMB. TYP. •1k ' September2i,2017 PRODUCT. 7HERtM-TRU FIBERGLASS DOOR. Doeumento P"wed Mn-,,BTATEOF Lyndon F. Schmitlf ��i�` '.ci07119� •'��� P.E. No. 43409 `OL,\���. GDQ/f/ BUILDING CONSULTANTS, INC.. PART'OR ASSEM8LY:, HORIZONTAL do VERTICAL CROSS SECTIONS !!�/ P•O. Box 23D• Vatrico; FL 33595 Phone Nos 813.659.9197 . FBPE CA No. 9813 RA0ienls%Therma Tm PERMANENTVI. Flodda Product ApprowlslFL-15225 Cen Mark -Install OrlIAC- DrawingskFL-1522S (2017)\FL-15225.1Lwg, 6 1-I /4' MIN_ 1-114•MIN. m EMB. (TYP.) O I I-1/4'MIN. I EMB.(TYP.) EMB. (TYP.)+� �. O tr a n =n o� �o d y Z = rn m 20 C) Z � a.. z Z rn I0 c =7N 1-1/4'MIN. p EMB. (IYP.) a 22 0 X 2 9 21 17 UPDATE TO M ED. 2017 FSC L.FS 1 2 OS 15 20 UPDATE TO 5TH ED. 14 FBC LFS NO DATE BY .... IA N T n \ D O tx}t T L O.4S MNK N 1414-MIN, �� $CFi �G � `�,,.� EMB. (►YP.) No.43409 •� * Sepfemhar2l, 2DI7 = - WDUCT. THERMA=TRU FlBEROLASS DOOR Dec —to Pmp—d By.—, ` Lyndon F. Setanldt � ••'•.;;tOF.....����� P.E. No. 43409 �iDBUILDING CONSULTANTS; INC. W OR ASSEMBLY. - VERTICAL CROSS SECTIONS YY P.O: Box•230, VaIrk6..FL M95 Phone Nos 813.659.9197 FBPE CA No. 9813