Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB # :205916-3pd/MH/ct CONTRACTOR:AEM & Associates PERMIT #:2010-0011 JOB LOCATION:12094 Harbor Ridge Boulevard NUC #630 Palm City, Florida Nuc Model:MC-1DR-P Nuc Serial #:30630 ITEM TESTED :Pool Fill in Compaction - Retest TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE PERCENT COMPACTION 1 South 0'-1'45 106.7 109.0 97.9% 2 1'-2'45 -"95.0% + 3 2'-3'50+-"95.0% + 4 3'-4'50+-"95.0% + 5 Center 0'-1'45 107.4 109.0 98.5% 6 1'-2'45 -"95.0% + 7 2'-3'50+-"95.0% + 8 3'-4'50+-"95.0% + 9 North 0'-1'45 106.3 109.0 97.5% 10 1'-2'45 -"95.0% + 11 2'-3'50+-"95.0% + 12 3'-4'50+-"95.0% + Soil Description: Brown Sand In Place Moisture: 7.5% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 109.0 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum Requirement for Unplumbed Backfill Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 12/10/2020 Email to: andre@aemandassociates.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 December 9, 2020 Disclaimer:Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been altered from the approved inspected condition. Proudly Serving Florida since 1990 106.0 107.0 108.0 109.0 110.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight