Loading...
HomeMy WebLinkAboutMEAD-REVISED R-30-MANUAL JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Dec-10 10:35:57 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...UICK\Documents\Wrightsoft HVAC\MEAD, GERARD.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information GERARD ADDITIONFor:5519 PINE TREE DR., FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh11235 Structure Btuh11424 Ducts Btuh2000 Ducts Btuh2870Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh13235 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh13579 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh1412 Ducts Btuh809Central vent (0 cfm) Btuh0 CoolingHeating (none)704704Area (ft²) Equipment latent load Btuh2221 63366336Volume (ft³)Air changes/hour 0.320.61 Equipment Total Load (Sen+Lat)Btuh15800 Equiv. AVF (cfm) 3464 Req. total capacity at 0.70 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make Make TraneTrade Trade TRANE Model Cond 4TTR4018L1AHRI ref Coil TEM6A0B24H21++TDR AHRI ref 7567539Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW3.8 Sensible cooling Btuh13160Heating output Btuh12812 Latent cooling Btuh5640 Temperature rise °F50 Total cooling Btuh18800Actual air flow cfm233 Actual air flow cfm627 Air flow factor cfm/Btuh0.018 Air flow factor cfm/Btuh0.044Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Dec-10 10:35:57Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1...UICK\Documents\Wrightsoft HVAC\MEAD, GERARD.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BATH 2 Exposed wall 120.0 ft 44.0 ft 3 Room height 9.0 ft 9.0 heat/coolft 4 Room dimensions ft256.0x1.0 5 Room area 704.0 ft²256.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 144 144 367 282 144 144 367 282 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 396 366 933 716 126 126 321 247 .GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 87.0687.06 30 2 1067 2612 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 144 144 367 282 0 0 0 0 11 WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 396 339 864 664 126 110 280 215 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 88.1488.14 41 2 1451 3596 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.4541.45 16 1 251 663 16 1 251 663 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 704 704 631 1126 256 256 229 410 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 704 120 3323 0 256 44 1218 0 6 c) AED excursion 926 367 Envelope loss/gain 9253 10867 2667 2183 12 a) Infiltration 1982 557 727 204 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)11235 11424 3394 2387 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 11235 11424 3394 2387 15 Duct loads 18%25%2000 2870 18%25%604 600 Total room load 13235 14294 3998 2987 Air required (cfm)Air required (cfm)233 627 70 131 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Dec-10 10:35:57Right-Suite® Universal 2019 19.0.21 RSU08101 Page 2...UICK\Documents\Wrightsoft HVAC\MEAD, GERARD.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name WIC WIC 2 2 Exposed wall 8.0 ft 8.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft8.0x6.0 ft8.0x6.0 5 Room area 48.0 ft²48.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 0 0 0 0 72 72 183 141 .GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 87.0687.06 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0 11 WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 72 72 183 141 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 88.1488.14 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.4541.45 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 48 48 43 77 48 48 43 77 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 48 8 222 0 48 8 222 0 6 c) AED excursion 0 0 Envelope loss/gain 448 218 448 218 12 a) Infiltration 132 37 132 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)580 255 580 255 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 580 255 580 255 15 Duct loads 18%25%103 64 18%25%103 64 Total room load 683 319 683 319 Air required (cfm)Air required (cfm)12 14 12 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Dec-10 10:35:57Right-Suite® Universal 2019 19.0.21 RSU08101 Page 3...UICK\Documents\Wrightsoft HVAC\MEAD, GERARD.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM 2 Exposed wall 60.0 ft 3 Room height 9.0 heat/coolft 4 Room dimensions ft22.0x16.0 5 Room area 352.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-0sw 0.091 n 2.55 1.96 0 0 0 0 .W 12C-0sw 0.091 e 2.55 1.96 198 168 428 329 .G 1A-c1om 1.270 e 35.56 87.06 30 2 1067 2612 .W 12C-0sw 0.091 s 2.55 1.96 144 144 367 282 11 W 12C-0sw 0.091 w 2.55 1.96 198 157 401 308 G 1A-c1om 1.270 w 35.56 88.14 41 2 1451 3596 G 4A5-2ob 0.560 w 15.68 41.45 0 0 0 0 C 16B-30ad 0.032 -0.90 1.60 352 352 315 563 F 22A-tpl 0.989 -27.69 0.00 352 60 1662 0 6 c) AED excursion 560 Envelope loss/gain 5690 8249 12 a) Infiltration 991 279 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)6681 8527 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 6681 8527 15 Duct loads 18%25%1189 2142 Total room load 7870 10669 Air required (cfm)139 468 Bold/italic values have been manually overridden 2020-Dec-10 10:35:57 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...UICK\Documents\Wrightsoft HVAC\MEAD, GERARD.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information GERARD ADDITIONFor: 5519 PINE TREE DR., FT. PIERCE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.28in H2O0.28 Available static pressure in H2O0.22in H2O0.22 Supply / return available pressure 0.110 / 0.110 in H2O in H2O0.110 / 0.110 Lowest friction rate in/100ft0.080in/100ft0.080 Actual air flow cfm627cfm233 Total effective length (TEL) ft88 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 70.09.0VlFx0x07.00.080131702987cMASTER BATH 70.04.1VlFx0x08.00.080234695335cMASTER BEDROOM 70.018.0VlFx0x08.00.080234695335cMASTER BEDROOM-B 70.03.6VlFx0x04.00.0801412319cWIC 70.03.6VlFx0x04.00.0801412319cWIC 2 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 2330 627 0 0 0 0 x0 0 VlFx