HomeMy WebLinkAboutMEAD-ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 412/10/2020 10:38 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY GERARD MEAD MEAD ADDITION Street: City, State, Zip: FT. PIERCE , FL , 5519 PINE TREE DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) Addition Single-family 1 No 396 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 15.00 ft² SHGC=0.30 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 396.00 ft² R=f t ² R=f t ² 9. Wall Types a. Frame - Wood, Exterior R=13.0 485.33 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 396.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: ADDITION 12. Cooling systems 13. Heating systems 14. Hot water systems a . Cap: N/A b. Conservation features d. N/A R=f t ² Area Weighted Average Overhang Depth:2.000 ft. Area Weighted Average SHGC:0.300 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None - None required (Bedrms In Addition) 0(0) (15.0 sqft.) (485.3 sqft.) (396.0 sqft.) (396.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 18.8 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 79 EF: -9.6369E036 Glass/Floor Area: 0.038 Total Proposed Modified Loads: Total Baseline Loads: 10.94 12.23 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply) FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 12-10-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY 1 GERARD MEAD MEAD ADDITION Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 396 0 Addition Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FT. PIERCE , St. Lucie 5519 PINE TREE DRIV Street Address Comment: Building Type: User Cross Ventilation: Whole House Fan: TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Block1 396 3168 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 ADDITION 396 3168 No 1 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS R-ValueSpace Perimeter 1 396 ft² 0 0 1______ Slab-On-Grade Edge Insulation - - - -078 ft ADDITION # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 429 ft² Medium 0.6 0 22.6______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 396 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 30 396 ft² 0.11 Wood______ ADDITION Blown 12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 13 0ADDITION 0816 8W Frame - Wood 0.60.25Exterior 133.3 ft² ____ 2 13 0ADDITION 022 8N Frame - Wood 0.60.25Exterior 176.0 ft² ____ 3 13 0ADDITION 022 8S Frame - Wood 0.60.25Exterior 176.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 S Low-E Single 0.65 0.3 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 369.6 720.29.000356Wholehouse .123338.16Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/Supplement COP:1 17 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/Supplemental for a SEER: 16 18.8 kBtu/hr 564 cfm 0.8______ sys#1None 1 Single FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 79 ft² Attic 20 ft² Default Leakage ADDITION (Default) c______ 1 1 (Default) c 12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 Heating (WEH) AMPM 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 ADDITION 12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT