HomeMy WebLinkAboutMEAD-ENERGY CALC (1)EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 412/10/2020 10:38 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
GERARD MEAD
MEAD ADDITION
Street:
City, State, Zip: FT. PIERCE , FL ,
5519 PINE TREE DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Addition
Single-family
1
No
396
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 15.00 ft²
SHGC=0.30
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 396.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Frame - Wood, Exterior R=13.0 485.33 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 396.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: ADDITION
12. Cooling systems
13. Heating systems
14. Hot water systems
a . Cap: N/A
b. Conservation features
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.300
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
- None required
(Bedrms In Addition) 0(0)
(15.0 sqft.)
(485.3 sqft.)
(396.0 sqft.)
(396.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
18.8 SEER:16.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 79
EF: -9.6369E036
Glass/Floor Area: 0.038
Total Proposed Modified Loads:
Total Baseline Loads:
10.94
12.23 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply)
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
12-10-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
1
GERARD MEAD
MEAD ADDITION
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
396
0
Addition
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FT. PIERCE ,
St. Lucie
5519 PINE TREE DRIV
Street Address
Comment:
Building Type: User
Cross Ventilation:
Whole House Fan:
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Block1 396 3168
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 ADDITION 396 3168 No 1 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
R-ValueSpace Perimeter
1 396 ft² 0 0 1______ Slab-On-Grade Edge Insulation - - - -078 ft ADDITION
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 429 ft² Medium 0.6 0 22.6______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 396 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 30 396 ft² 0.11 Wood______ ADDITION Blown
12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 13 0ADDITION 0816 8W Frame - Wood 0.60.25Exterior 133.3 ft² ____
2 13 0ADDITION 022 8N Frame - Wood 0.60.25Exterior 176.0 ft² ____
3 13 0ADDITION 022 8S Frame - Wood 0.60.25Exterior 176.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.65 0.3 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
369.6 720.29.000356Wholehouse .123338.16Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/Supplement COP:1 17 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/Supplemental for a SEER: 16 18.8 kBtu/hr 564 cfm 0.8______ sys#1None 1 Single
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 79 ft² Attic 20 ft² Default Leakage ADDITION (Default) c______ 1 1 (Default) c
12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868
Heating (WEH) AMPM 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868 6868
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 ADDITION
12/10/2020 10:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT