HomeMy WebLinkAboutProduct Approval, underlayment ' .._x..-.ar,t_..rase:r' ....�_n�S: .y+r. t_«•.vt..__ ,.,..
+:
. ' ECIS Home ; Log In ` User Registration i Hat Topics Submit SurChaige Scats&Facts Publications FEC Staff BCIS Site Flap Links Search
Business- ``-,
Professional 0-1l-
)Product licUerOVaO
1'er-j1.1 llC-
t'roduct Approval Menu>Nodixt or 4ovlirat-on`vAi Ui>A plitation. List>Application Detail
FL# FL9777-117 THESE PLANS AND ALL PROPOSED WORK
Application Type Revision
Code Version 2014 71"ARE SUBJECT TO AWpa CORRECTIONS !
Application Status Approved REQUIRED BY-FIELD INSKCTORS THAT;
qpp �,j p g��pg�9 ® �'ST�
Comments `F @l�q® yB��g"" �7QyR .4g0�9 F�B1p® �1�y�T®0
Archived .0Qf�11F'Li,.A�AeH.ALLP4II�KIQABLE- 9,P9%4
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keel er@owenscorning.co
Technical Representative ST.LLTC�'C471T__ PUi7PPiTC?tWISlDoi
Address/Phone/Email R.EEWEED FOR C01' PAN-'CE
REvF:VED B
Quality Assurance Representative DATE �,
Address/Phone/Email PLANS AND EkAIIT MUST BE KEPT ON JO .
OR NO INSPECTION WJIL BE NLUDE.
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
i
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract-Expiration Date 12/31/2020
Validated By Locke Bowden
J Validation Checklist- Hardcopy Received
Certificate of Independence FL9777 R7 COT OCR14007 4A FBA�014� ration Report Weatherl2Sk
fypn-HVHZ - final,-piff
i
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2009
ASTM G 155 2005
TAS 103 1995
UL 1897 2004
Equivalence of Product Standards
Certified By
Sections from the Code
I
I
I.
i
I '
I
I
Product Approval Method Method 1 Option D �,
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/21/2016
Date Approved 06/08/2016
Summary of Products_
--- ---?---_Y._. _- -- — — — —
FL# j Model,Number or Name Description
be _.
9777.1 Weatherlock G Weatherproofing Underlayment�
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9777 R7 11 OCR14002^4A FBG 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ_ - final.odf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021 i
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCRI4002AA FBC 2.014 Evaluation Report
Weatherlock Non-HVHZ- fi%al.pdf
Created by Independent Third Party: Yes
9777.2 Weatherlock MAT --__� — Waterproofing Underlayment
Limits of Use � InstaRation Instructions
Approved for use in HVHZ: No FL9777 R7 if OCR14002 4A FBC 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ - final.odf
Impact Resistant: N/A Verified By: Zachary R. Priest 7402.1
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002AA FBC 2014 Evaluation Re-port
Weatherlock Non-FIVIIZ-final,pd�
Created by Independent Third Party: Yes
9777.3 �__--- Weatherlock Metal — Weatherproofing Underlayment
Limits of Use Installation Instructions ,E
Approved for use in HVHZ:No FL9777 R7 11 OCR]4002.4A FBC 2014 Evaivationae or
it
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf 1
Impact Resistant: N/A Verified By: Zachary R, Priest PE-74021
Design Pressure:N/A Created by Independent Third Party: Yes 4
Other:See evaluation report for limits of use. Evaluation Reports {
FL9777 R7 AE OCR14002 4A FBC 2014 Evaluation Report
Weatherlock Non-HVHZ- fin@l.odf
Created by Independent Third Party: Yes
9777.4 —y WeatherLock Metal (Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes fJ 9777 R7 11 OCR14002.48 FBC 2014 Evaluation Report
Approved for use outside HVHZ:No Weatherlock Met0.LUVH -final.odf
Impact Resistant: N/A i Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002.48 FBC 2014 Evaluation Itcp«rt I
1 Weatherlock Metal HVHZ -final.pdf t
t Created by Independent Third Party: Yes
9777.5 I WeatherLock Specialty Tile&Metal Weatherproofing Underlayment
Limits of Use ,Installation Instructions
Approved for use in HVHZ:No ! FL9777 R7 1[ OCR1gQQ2AA FBC 2014 L n Ren)rt
Approved for use outside HVHZ:Yes Weatherlock Non-1iVH7-final.pdF
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-105 Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
y FL9777 R7 AE OCRH 02.4A FBC 2014 Evaluation Report
I,Weatherlock Non-HVHZ final ndf
Created by Independent Third Party: Yes
—
'0 0
i
I Contact Vs:: 19-10 North Monroe Street.Tallahassee FL 32399 Phone:850-487.1R2.7
The State Of Florida is an AA/EEO employer.Copydribt 2007-2013 State or Florida. ::Privaol Statement::Accessibility StLtemen ::Refund Stadaiieot
I�
I
i v fir,
Certificate A o z ti 24���,'
1
t. EdiYt' urg Drive
Tampa, FL 336471
f ^ (813)480-3421I
TECHNICAL SERVICES, LLC
EVALUATION REPORT FLORIDA BUILDING CODE 5 THEDITION(2014)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016
1 Owens Corning Parkway
Toledo,OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Location: Brentwood,NH
Quality Assurance: UL LLC(QUA9625)
SCOPE _
Category: -Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5,1507.4.5.2, 1507.5.3,
1507.5.3.2, 1507.7.3, 1507.7.3.2
Properties: Physical properties
REFERENCES _n
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OGF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock®G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq, rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
I'
WeatherLock®Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed from'
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock®Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
OCR14002.4A FL9777-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not
specifically addressed herein.
' `I
------_���� �
x����.O�"��B^� uvvo`"^""""`"
»~=^Q`�N�=��.K-� vvoa »vrL»oN0Se Ice&Water Barriers
� TECHNICAL SERVICES, LLC .
}
DVeatherLuoW®RK0eto! WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from
\ SB3 modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
| product io supplied\^2.O sq. roils with nominal dimensions of 3'ftx60J'h. /
VYoathnrLunk(9 k4etu| is permitted to be used with mechanically fastened asphalt
| shingles, roof metalpun�o or shingles, wood shakes or shingles, and slate roofing as
�
� prescribed in the FBC. Exposure on the roof deck shall bo limited to amaxknum 80
days.
VVpatherLookg) YVootherLnok@ Specialty Tile & Metal is an AOTMD 18TD self-adhesive ungoA n(
Specialty Tile&Metal constructed from SBGmndifiod asphalt and surfaced with u non-woven polyester fabric.
The product is supplied/o2.14 sq. rolls with nominal dimensions of 3'ftx71.34l.
WeatherLodkl&Gpedalty Tile& Metal is permitted to be used with mechanically fastened
asphalt sUingloa, clay orconcrete h|n` metal roof panels nr shingles, wood shakes o,
ohing|on, and slate roofing omprescribed in the F8C. VVaathorLook@ Specialty Tile &
Metal is permitted to be used with adhered clay or concrete tile roofing using either3Mrw
2-Component Foam Roof Tile Adhesive AH'100 (5K8 Company) or TILE BOND'~ Roof
Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall balimited
hou maximum Q0days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
� without bo#woa. Tile shall be stored on boVono for roof slopes greater than 6:12. Tiles,
! shall not be stacked greater 1O tiles per stack.
PRODUCT APPLICATION
Min. Roof Slope: 212orin accordance in with F8C
Application: Deck substrates shall be clean, dry, and free from any irregularities and debris, 40
fasteners hn the deck shall he checked for protrusion aodno/reohadprio/Aoundorlaymont
� application. Prior to beginning /nztoVa0bn. the vndedaymont ohe0 be unrolled and
allowed&n relax for a minimum of3'5minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
� into place to ensure complete contact with the deck. The underlayment shall be installed
� with the mU length parallel to the eavo, starting at the oavo, and with minimum 3~ side
. laps and minimum 0^ end )opu staggered 6-ft. from preceding course. End |opn for
VVootharLocW0 Specialty Tile& Metal shall ba primed with AGTMD41 primer orsealed,
with asphalt roof cement a minimum of34 inches across the width of the lap.
U is permissible to nail the undedoymnnt 18-inches on-center as needed (nails shall be,
installed perpendicular N deck with the nail heads flush W the top surface of the
undodaymont). VYeaihnrLock@ Specialty ll|o & k4oby/ ahm|/ he book nailed when
installed nn roof slopes greater than 312.
| For valley app|ioadono. the mU shall be applied non0areg along the valley prior to
installing the undoduyment at the eavo. Foroavo protection, the undodnymont should
extend 0ua point 24'nohen inside the exterior wall.
The undadayment shall bn installed over metal drip edge at the ou"o'and under the drip
edge at the rake or valley pan when used as a valley liner. AJtomo(o|y' it is pnnniooih|o
to install the underlayment under the drip edge in accordance Section 1507.2,9.3.
Min. Application 40°F: Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature,
OCn140024A FL9777'n7 Page u of*
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
/|
� ,
« ' OWENS CORNIN R QFlfvG AND ASPHALT LLC'I
1 RE ice, WeatherLockO Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLCI
i
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlayment System,No.1
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: Weatherl-ock® Specialty Tile & Metal shall be applied in accordance with'
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underiayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -105 psf
Pressure:
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published,
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC`
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be property ventilated in accordance with the FBC requirements:
6) All side lap seams shall be installed to shed water from the deck.
7) The underiayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underiayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
i
j
OCR14002AA FL9777-R7 Page 3 of 4'
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. -The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.,
This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not
specifically addressed herein.
'I
1
I
t y- OWENS CO
N 1G t� P. ALT LLC;Z E �'°�, WeatherLSelf Sealing Ice&:Water Barriers
t + �F�i�:�
`dam TECHNICAL SERVICES, LLC
I
COMPLIANCE.csTATEMENT _
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building','
Code 5M Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer.
t.0111111111111,
�G R' 2016.04.19
4 No 74021 '� �l 5.5 .1 1
rZ Q4.'00'
-33 STATE OF �1U
A'� Q P.����: Zachary R. Priest, P.E.
• R i. 6,o.` Florida Registration No. 74021
�01'tSI �
QNA �� Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products;
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
l
END OF REPORT
OCR14002.4A FL9777-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.