Loading...
HomeMy WebLinkAboutProduct Approval ,metal IWO . .tom. -�r^_(,.t,...`fi`S� .T'��•h,;y 1C�',t °,'ti,�`��,I"� "�' '�` '.Y� .�. _ S ae r.:rs.=^n' F�� ray, �,.� N �. •i � �a ' *M . . y�,yam y +'' .'[5, AZ µ1� �. •A j iir.3w ..A.c-,'- y�.a- S :�:h5n'`�'�`.��.:i.,��.�1' BCISHome Log In ! User Registration Hot Topics Submit Surcharge ; Stats&Facts i Publications ; FBC Staff ' BCIS Site Map Links Search ;i 4f{. Product Approval USER:Public User - Pr durs ApLroval Menu>Product or noel'Calion Search>nunlicati0n List>Application detail RN C ; FL# 117443 .' Application Type Code Version 2014 Application Status Approved Comments Archived Product Manufacturer 7 A TAYLOR ROOFING Address/Phone/Email 302 Melton Drive FT PIERCE, FL 34982 (772)466-4040 kylewhite228@aol.com Authorized Signature Kyle Taylor kylewhite228@aol.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory M 4W =RooFtrij; Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 4Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone,Certifications, Inc. Quality Assurance Contract Expiration Date 04/11/2021 Validated By Hermes F..Norero,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL17443 R0 COI Certificate of Indeoend Locke Bowden P.E..ndf Referenced Standard and Year(of Standard) Standard .Y�k ULS80 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D j e } F Date Submitted 03/02/2015 Date Validated 03/02(2015 Date Pending FBC Approval 03/05/2015 Date Approved 04/15/2015 Summat r"f products FL# Model,Number or Name f Description 17443.1 5 V Crimp 1 26GA 1/2"rib height over 15/32"plywood Limits of Use Installation Instructions 1 Approved for use in HVHZ:No FL17443 RO 1T 5 V Crimp Fastening_p.ejajLp if Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC i Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-129.25 Evaluation Reports Other:-129.2S @ 6"o.c. -69.25 @16"o.c. margin of safety FL17443 RO AF FL 17443 l A Taylor Rooting S V Crimes 2:1 with 24"max. coverage Install per manufacturers detail. �pQrs.Ddf Not for use In HVHZ. Created by Independent Third Party: Yes ,7;r r:lt ttiE Contact :: 2601 Mali`Stone Road Tallahassee FL 32399 phone:f150-487.1H24 The State of Florida 15 an AA/EEO employer.Coovrl ht 2007-2013 State of Florida ::pr)vacv Statement::Arcessibility Statement::Rsfund 5ratement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity,instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.•Pursuant to section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,Please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: EM ® r.rdl Credit Card Safe I ' r l Locke Bowden, P.E. 9450 Alysbur/Place Montgomery,AL 36117 FL# 17443 ,IA'Taylor Roofing Inc 302 Melton Drive Fort Pierce,FL 34982 Product: 5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage, 26GA min_ over min.l5/32" thick CDX plywood decks. Compliance: Elorida Building Code(FBC)2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3 UL580 `°Pests for Uplift Resistance" Description: Architectural metal roof panel,26 gauge metal panels;over min. 15/32"CDX plywood and shall comply with Florida Building Code 2014, Section 1507.4.3 Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2 Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2. Design Pressure: -129.25 psf @ 6"o.c. and-69,25psf@16"o.c.; Fasten along the crown of the rib in the center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3" of panel edges. Min. 8d x 2"annular ring shank nails spaced 6"o.c. reroofing, with less than 19/32" plywood 91nin. 15/32"), this attachment is to be used in addition to existing attachment. Deck attachment to be by other design professional. Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8 Thru-fastened over min.15/32"plywood Fasteners: #9-15 I•IWH corrosion resistant fasteners with scaling washers, metal to wood connections with fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4 Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein manufacturer complies under a quality assurance program audited by approved Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021 Evidence Submitted: a. UL 580/TAS 125 Tests for Uplift Resistance b. Reference-Test Report 0224-0501-06 Hurricane Test Laboratory ���tt,tnrrrr, C. 'rest equivalency standard—the UL 580-94 test standard is equiXin�offv f6,�0-06 d. Quality Assurance Procedures and Documentation ��C�°'G ' No.49704 0.� 1✓6� o�J4. c� 2 /X_j FLe� cm p� (1 .�``• Tlris report ducts riot guarantcc or wamrnty any product vtdidrricd or instnilcd.Manuracturcr's warranty applies. I 1h i 5 V Crimp Fastener-#9-15 corrosion resistant w/sealin9 washers I it 24" coverage t'Ai JfY I, I ® yew 4 Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with 2014 Florida Building Code, Section 1507.4.4 Perimeter fastening: 6"o.c. Main Field fastening12"o.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel I, i