HomeMy WebLinkAboutProject Information FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index,the more efficient the home.
3917 Shoreside Drive, Hutchinson Island, FL, 34949
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1736.00 ft2
b.Frame-Wood,Adjacent R=13.0 336.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Roof Deck(Unvented) R=20.0 1976.00 ft2
6. Conditioned floor area(ft2) 1976 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor. Dial,U=0.66 301.44 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:Attic,AH:Garage 6 395.2
SHGC: SHGC=0.32
b. U-Factor: Dbl,U=1.01 96.00 ft2
SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 47.0 SEER:16.00
SHGC:
d. N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
SHGC:Area Weighted Average Overhang Depth: 7.789 ft. a.Electric Heat Pump 45.5 HSPF:9.00 �
Area Weighted Average SHGC: 0.315
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1976.00 ft2 EF:0.95
b.N/A R= ft2 b. Conservation features
c.N/A R= ft2 None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed(or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. ti ru„•
Builder Signature: Date: 02'/'WiZ
Address of New Home City/FL Zip: C�
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 1
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
i
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FILE
copy