Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance it .i Planning& Development Services Department a Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance t. �- PO FLATS LOT 6 - MODEL A t Pr6jba-Name:i'�� Project Address: 3917 Shore Side Drive Ft. Pierce, FL. i Permit#: I Occupancy Type: R-3 Construction Type:V-B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with,all permit applications involving the following:i o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph ASD x LRFD End Zone Width: 4.98 ft 5. Mean Roof Height 15.33' ft Roof Pitch: 6 :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:-44.63 Zone 2: -74.76 Zone 3: -74Y76 Zone 4:-45.6 Zone 5:-57.8 Garage: 7. Design Loads: Floor: 138 PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: PSF Dock: N/A PSF Deck: NSA PSF Stairs: NSA PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural eleme is depicted on these plans provide adequate resistance to the design forces sRq�Oldd:l I I I l,,, AS U Farid Abugattas PE 72471 �C , LICEN 9 �'�� Print Name Cert#&Co.Cert Auth. * No Z = Project Classic LLC 4, Si®ature, Dat ,and Seal ,:. = 7318 Texas Trail, Boca Raton, FL. 33487 �O E pF �\ Company Name&Address�IDA C09 Revr�eti�/ 5/2014 ''GN \� �//,,/AL,IE,*CHECKED JAN 2 7 2017