HomeMy WebLinkAboutProject Information (2) r
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department,of Business and Professional Regulation - Residential Performance Method
Project Name: Lot6TarponFlats Builder Name: Phoenix Realty Homes Inc
Street: 3917 Shoreside Drive Permit Office:
City,State,Zip: Hutchinson Island,FL,34949 Permit Number.
Owner: Jurisdiction: 661100
Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2072.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1736.00 ft'
b.Frame-Wood,Adjacent R=13.0 336.00 ft'
3. Number of units,if multiple family 1 c.N/A R= ft'
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1976.0 sqft.) Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 1976.00 ft'
6. Conditioned floor area above grade(ft) 1976 b.N/A R= ft'
Conditioned floor area below grade(ft') 0 c.N/A R= ft'
11.Ducts R ft',
7. Windows(397.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 395.2
` a. U-Factor: Dbl,U=0.66 301.44 ft'
SHGC: SHGC=0.32
b. U-Factor: Dbl,U=1.01 96.00 ft' 12.Cooling systems kBtu/hr Efficiency;
SHGC: SHGC=0.30 a.Central Unit 47.0 SEER:16.00
c. U-Factor: N/A ft'
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft' a.Electric Heat Pump 45.5 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 7.789 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (1976.0 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1976.00 ft' b. Conservation features EF:0.950
b.N/A R= ft' None
c.N/A R= ft' 15.Credits Pstat
Glass/Floor Area: 0.201 Total Proposed Modified Loads: 67.91 PASS
Total Baseline Loads: 70.00
I hereby certify that the plans and specifications covered by Review of the plans and O1tB S
this calculation are in compliance with the Florida Energy specifications covered by this
Code. - calculation indicates compliance
''� with the Florida Energy Code.
PREPARED BY: 4� 4fNt Before construction is completed r C
DATE: 1L31117 this building will be inspected for
compliance with Section 553.908 * g
I herebycertify that this building,as designed,is in compliance Florida Statutes.
fY 9, 9
with the Florida Energy Code. Op y
OWNER/AG BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house.
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pagel 1 of 5
RE coin
::
FORM R405-2014
PROJECT
Title: Lot6TarponFlats Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1976 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Phoenix Realty Homes Inc Rotate Angle: 0 Street: 3917 Shoreside Drive
Permit Office: Cross Ventilation: No County: St.Lucie
Jurisdiction: 661100 Whole House Fan: No City,State,Zip: Hutchinson Islandi,
Family Type: Single-family FL, 34949
New/Existing: New(From Plans)
Comment:
CLIMATE
i
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Blockl 1976 18376.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1976 18376.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 186 ft 0 1976 ft2 ___ 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. • (deg)
1 Gable or Shed Composition shingles 2210 f12 494 ft2 Medium 0.85 N 0.85 No 20 26.6
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 1976 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) Main 0.01 Blown 1976 ft2 0.11 Wood
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
i
i
FORM R405-2014
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar I Below# Qmt TO Wall Type SpaceR--Vaftfp Et
_ 1 NE Exterior Concrete Block-Int Insul Main 4.1 30 0 9 4 280.0 ftZ 0 0 0.6 0
_2 SE Exterior Concrete Block-Int Insul Main 4.1 48 6 9 4 452.7 ftZ 0 0 0.6 0
3 SW Exterior Concrete Block-Int Insul Main 4.1 29 0 9 4 270.7 ft2 0 0 0.6 0
4 NW Exterior Concrete Block-Int Insul Main 4.1 31 6 9 4 294.0 ft' 0 0 0.6 0
_ 5 - Garage Frame-Wood Main 13 36 0 9 4 336.0 ft' 0 0.23 0.01 0
_6 NE Exterior Conlcrete Block-Int Insul Main 4.1 7 0 9 4 65.3 ft' 0 0 0.6 0
7 SW Exterior Concrete Block-Int Insul Main 4.1 30 0 9 4 280.0 ft' 0 0 0.6 0
8 NW Exterior Concrete Block-Int Insul Main 4.1 10 9 4 93.3 ft' 0 0 0.6 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 NE Wood Main None .25 3 8 24 ft'
2 - Wood Main None .25 2 8 8 21.3 ft'
� I
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 NE 1 Metal Low-E Double Yes 0.66 0.32 8.3 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None
2 NE 1 Metal Low-E Double Yes 0.66 0.32 31.0 ft' 2 ft 0 in 0 ft 4 in Drapestblinds 'None
3 NE 1 Metal , Low-E Double Yes 0.66 0.32 31.0 ft' 3 ft 0 in 0 ft 3 in Drapes/blinds ,None
4 NE 6 Metal Low-E Double Yes 0.66 0.32 10.7 ft' 9 ft 2 in 0 ft 2 in None None
5 SE 2 Metal Low-E Double Yes 0.66 0.32 13.3 ft' 2 ft 0 in 0 ft 4 in None None
6 SE 2 Metal Low-E Double Yes 0.66 0.32 26.7 ft' 2 ft 0 in 0 ft 4 in None None
7 SW 3 Metal Low-E Double Yes 0.66 0.32 33.8 ft' 2 ft 0 in 0 ft 4 in None None
8 SW 3 Metal Low-E Double Yes 0.66 0.32 31.7 ft' 2 ft 0 in 0 ft 4 in None None
9 SW 3 Metal Low-E Double Yes 0.66 0.32 38.0 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None
10 SW 7 Metal Low-E Double Yes 0.66 0.32 50.7 ft' 13 ft 0 in 0 ft 4 in Drapes/blinds None
11 SW 7 Metal Low-E Double Yes 1.01 0.3 96.0 ft' 13 ft 0 in 0 ft 4 in None None
12 NW 8 Metal Low-E Double Yes 0.66 0.32 20.0 ft' 31 ft 0 in 0 ft 4 in None None
13 NW 4 Metal Low-E Double Yes 0.66 0.32 6.3 ft' 2 ft 0 in 0 ft 4 in Drapestblinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 595 ft' 595 ft' 64 ft 8 ft 1
I
' I
I
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
i
FORM R405-2014
INFILTRATION
I
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000295 1531.4 84.07 158.11 .2157 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:9 45.5 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block (Ducts
1 Central Unit Split SEER:16 47 kBtu/hr cfm 0.76 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None i
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftZ
DUCTS i
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 395.2 ft Attic 98.8 ftz Proposed Qn Garage —cfm 98.8 cfm 0.05 0.50 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Jan Feb Mar Apr
Au rj Sep Oct Nov Dec
Heating H Jan H Feb HX Mar Apr May jXj
Jun Jul n rl Jul rl
Aug Sep Oct Nov
X Nov H Dec
Venting
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
i
FORM R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
w Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
Runtime Vent 58 0 0 1-Electric Heat Pump % 1-Central Unit
I
I
i
y
1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
I