Loading...
HomeMy WebLinkAboutProject Information (2) r FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department,of Business and Professional Regulation - Residential Performance Method Project Name: Lot6TarponFlats Builder Name: Phoenix Realty Homes Inc Street: 3917 Shoreside Drive Permit Office: City,State,Zip: Hutchinson Island,FL,34949 Permit Number. Owner: Jurisdiction: 661100 Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2072.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1736.00 ft' b.Frame-Wood,Adjacent R=13.0 336.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1976.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 1976.00 ft' 6. Conditioned floor area above grade(ft) 1976 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft', 7. Windows(397.4 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 395.2 ` a. U-Factor: Dbl,U=0.66 301.44 ft' SHGC: SHGC=0.32 b. U-Factor: Dbl,U=1.01 96.00 ft' 12.Cooling systems kBtu/hr Efficiency; SHGC: SHGC=0.30 a.Central Unit 47.0 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 45.5 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 7.789 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1976.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1976.00 ft' b. Conservation features EF:0.950 b.N/A R= ft' None c.N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.201 Total Proposed Modified Loads: 67.91 PASS Total Baseline Loads: 70.00 I hereby certify that the plans and specifications covered by Review of the plans and O1tB S this calculation are in compliance with the Florida Energy specifications covered by this Code. - calculation indicates compliance ''� with the Florida Energy Code. PREPARED BY: 4� 4fNt Before construction is completed r C DATE: 1L31117 this building will be inspected for compliance with Section 553.908 * g I herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9, 9 with the Florida Energy Code. Op y OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. 1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pagel 1 of 5 RE coin :: FORM R405-2014 PROJECT Title: Lot6TarponFlats Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1976 Lot# Owner: Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Phoenix Realty Homes Inc Rotate Angle: 0 Street: 3917 Shoreside Drive Permit Office: Cross Ventilation: No County: St.Lucie Jurisdiction: 661100 Whole House Fan: No City,State,Zip: Hutchinson Islandi, Family Type: Single-family FL, 34949 New/Existing: New(From Plans) Comment: CLIMATE i / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1976 18376.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1976 18376.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 186 ft 0 1976 ft2 ___ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. • (deg) 1 Gable or Shed Composition shingles 2210 f12 494 ft2 Medium 0.85 N 0.85 No 20 26.6 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1976 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0.01 Blown 1976 ft2 0.11 Wood 1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 i i FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar I Below# Qmt TO Wall Type SpaceR--Vaftfp Et _ 1 NE Exterior Concrete Block-Int Insul Main 4.1 30 0 9 4 280.0 ftZ 0 0 0.6 0 _2 SE Exterior Concrete Block-Int Insul Main 4.1 48 6 9 4 452.7 ftZ 0 0 0.6 0 3 SW Exterior Concrete Block-Int Insul Main 4.1 29 0 9 4 270.7 ft2 0 0 0.6 0 4 NW Exterior Concrete Block-Int Insul Main 4.1 31 6 9 4 294.0 ft' 0 0 0.6 0 _ 5 - Garage Frame-Wood Main 13 36 0 9 4 336.0 ft' 0 0.23 0.01 0 _6 NE Exterior Conlcrete Block-Int Insul Main 4.1 7 0 9 4 65.3 ft' 0 0 0.6 0 7 SW Exterior Concrete Block-Int Insul Main 4.1 30 0 9 4 280.0 ft' 0 0 0.6 0 8 NW Exterior Concrete Block-Int Insul Main 4.1 10 9 4 93.3 ft' 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Wood Main None .25 3 8 24 ft' 2 - Wood Main None .25 2 8 8 21.3 ft' � I WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Double Yes 0.66 0.32 8.3 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None 2 NE 1 Metal Low-E Double Yes 0.66 0.32 31.0 ft' 2 ft 0 in 0 ft 4 in Drapestblinds 'None 3 NE 1 Metal , Low-E Double Yes 0.66 0.32 31.0 ft' 3 ft 0 in 0 ft 3 in Drapes/blinds ,None 4 NE 6 Metal Low-E Double Yes 0.66 0.32 10.7 ft' 9 ft 2 in 0 ft 2 in None None 5 SE 2 Metal Low-E Double Yes 0.66 0.32 13.3 ft' 2 ft 0 in 0 ft 4 in None None 6 SE 2 Metal Low-E Double Yes 0.66 0.32 26.7 ft' 2 ft 0 in 0 ft 4 in None None 7 SW 3 Metal Low-E Double Yes 0.66 0.32 33.8 ft' 2 ft 0 in 0 ft 4 in None None 8 SW 3 Metal Low-E Double Yes 0.66 0.32 31.7 ft' 2 ft 0 in 0 ft 4 in None None 9 SW 3 Metal Low-E Double Yes 0.66 0.32 38.0 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None 10 SW 7 Metal Low-E Double Yes 0.66 0.32 50.7 ft' 13 ft 0 in 0 ft 4 in Drapes/blinds None 11 SW 7 Metal Low-E Double Yes 1.01 0.3 96.0 ft' 13 ft 0 in 0 ft 4 in None None 12 NW 8 Metal Low-E Double Yes 0.66 0.32 20.0 ft' 31 ft 0 in 0 ft 4 in None None 13 NW 4 Metal Low-E Double Yes 0.66 0.32 6.3 ft' 2 ft 0 in 0 ft 4 in Drapestblinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 595 ft' 595 ft' 64 ft 8 ft 1 I ' I I 1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 i FORM R405-2014 INFILTRATION I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1531.4 84.07 158.11 .2157 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:9 45.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block (Ducts 1 Central Unit Split SEER:16 47 kBtu/hr cfm 0.76 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 62.3 gal 120 deg None i SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS i / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 395.2 ft Attic 98.8 ftz Proposed Qn Garage —cfm 98.8 cfm 0.05 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Jan Feb Mar Apr Au rj Sep Oct Nov Dec Heating H Jan H Feb HX Mar Apr May jXj Jun Jul n rl Jul rl Aug Sep Oct Nov X Nov H Dec Venting 1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 i FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 w Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 58 0 0 1-Electric Heat Pump % 1-Central Unit I I i y 1/31/2017 3:54 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I