Energy Calculation Form & Manual J's
Job: LotffarponFlats Manual S Compliance Report Date: 01.18.14 QDEL-AIR s i,AM CO Mumm Entire House By: ER DEL-AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project • • For;: Phoenix Realty Homes Inc, Model A FL Cooling Equipment Design Conditions Outdoor design DB: 90.5°F Sensible gain: 32850 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.8°F Latent gain: 8358 Btuh Entering coil WB: 63.8°F Indoor design DB: 7510°F Total gain: 41208 Btuh Indoor RH: 50% Estimated airflow: 1567 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer: Trane Model: 4TWR6048H1+TEM6AOD48H41++TDR Actual airflow: 1567 cfm Sensible capacity: 35378 Btuh 108%of load Latent capacity: 11146 Btuh 133%of load Total capacity: 46524 Btuh 113%of load SHR: 76% Heating Equipment Design Conditions Outdoor design DB: 43.0°F Heat loss: 34228 Btuh Entering coil DB: 68.8°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Trane Model: 4TWR6048H1+TEM6AOD48H41++TDR Actual airflow: 1567 cfm Output capacity: 45008 Btuh 131%of load Capacity balance: 36 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF i i Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1567 cfm Output capacity: 0 kW 0%of load Temp. rise: 0 OF Meets are all requirements of ACCA Manual S. A wri htsoft' 2017-Jan-3113:49:22 �.�.. g Right-Suite®Universal 2017 17.0.16 RSU24011 A ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE Page 1 I i Job: Lot6TarponFlats +M Component Constructions DEL-AIR- p Date: 01.18.14 xlt�mxs:amcax�ttt Entire House By: ER DEL-AIR HEATING &AIR CONDITIONING I 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project • • For: Phoenix Realty Homes Inc, Model A FL Design Conditions Location: Indoor: Heating Cooling Vero Beach Muni, FL, US Indoor temperature(OF) 70 75 Elevation: 30 ft Design TD (OF) 27 16 Latitude: 280N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) -0.1 59.41 Dry bulb(OF) 43 91 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(OF) - 78 Construction quality Semi-tight Wind speed(mph) I 15-.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM ;Gain fF BWhfiF--°F ft2--°FBWh BWhtftz BWh MOM Btuh Walls 13A-2ocs:Blk wall,stucco ext,r-2 ext bd ins,8"thk,1/2"gypsum ne 240 0.201 0 5.43 1304 4.98 1197 board intfnsh se 413 0.201 0 5.43 2239 4.98 112056 sw 300 0.201 0 5.43 1630 4.98 �1497 nw 361 0.201 0 5.43 1958 4.98 111798 all 1314 0.201 0 5.43 7131 4.98 6548 Partitions 12C-Osw:Frm wall,r-13 cav ins,1/2"gypsum board int fnsh,2"x4" 315 0.091 13.0 2.46 773 1.62 510 wood frm,16"o.c.stud Windows 2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,cir innr, ne 8 0.660 0 17.8 149 27.8 232 1/4"gap,1/8"thk;NFRC rated(SH1310=0.32);50%drapes,medium;2 ft overhang(4.17 ft window ht,0.33 ft sep.);6.67 It head ht 2A-2om:2 glazing,cir low-e outr,air gas,mtl no brk frm mat,cir innr, ne 31 0.660 0 17.8 552 27.8 861 1/4"gap,1/8"thk;NFRC rated(SH1313=0.32);50%drapes,medium;2 It overhang(5.17 ft window ht,0.33 ft sep.);6.67 ft head ht 2A-2om:2 glazing,cir low-e outr,air gas,mtl no brk frm mat,cir innr, ne 31 0.660 0 17.8 552 27.8 861 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);50%drapes,medium;3 ft overhang(5.17 ft window ht,0.25 ft sep.);6.67 ft head ht i 2B-2fm:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, ne 11 0.660 0 17.8 190 32.2 343 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);9.17 ft overhang(8 ft window ht,0.17 It sep.);6.67 ft head ht 2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,cir innr, se 13 0.660 0 17.8 238 23.3 311 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(5 ft se 27 0.660 0 17.8 475 23.3 622 window ht,0.33 ft sep.);6.67 ft head ht all 40 0.660 0 17.8 713 23.3 934 2A-2om:2 glazing,cir low-e outr,air gas,mtl no brk frm mat,clr innr, sw 34 0.660 0 17.8 602 25.2 853 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);2 ft overhang(6.33 ft sw 32 0.660 0 17.8 564 25.2 799 window ht,0.33 ft sep.);6.67 ft head ht all 65 0.660 0 17.8 1166 25.2 1652 ge wri htsoft* 2017-Jan-3113:49:22 9 Right-Suite®Universal 2017 17.0.16 RSU24011 ...nstruction\Lot6T Page 1 arponFlats\Lot6TarponFlats.rup Calc=MJB House faces:NE , i i 2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, sw 38 0.660 0 17.8 677 22.1 1 841 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);50%drapes,medium;2 ft overhang(6.33 ft window ht,0.33 ft sep.);6.67 ft head ht 2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, sw 51 0.660 0 17.8 903 15.0 ! 761 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);50%drapes,medium; 13 ft overhang(6.33 ft window ht,0.33 ft sep.);6.67 ft head ht 2A-2omd:2 glazing,clr low-e outr,!air gas,mtl no brk frm mat,clr innr, sw 96 1.010 0 27.3 2618 21.9 2107 1/4"gap,1/8"thk;NFRC rated(SHGC=0.30);13 ft overhang(8 ft window ht,0.33 ft sep.);6.67 ft head ht I 1 OC-m:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, nw 20 0.660 0 17.8 356 22.5 450 1/4"gap,1/8"thk;NFRC rated(SHGC=0.32);31 ft overhang(8 ft window ht,0.33 ft sep.);6.67 ft head ht 2A-2om:2 glazing,clr low-e outr,air gas,mtl no brk frm mat,clr innr, nw 6 0.660 0 17.8 113 27.8 176 1/4"gap,118"thk;NFRC rated(SHGC=0.32);50%drapes,medium;2 ft overhang(3.17 ft window ht,0.33 ft sep.);6.67 ft head ht Doors 11 DO:Door,wd so type ne 24 0.390 0 10.5 253 11.4 274 n 21 0.390 0 10.5 225 11.4 244 ` all 45 0.390 0 10.5 477 11.4 518 Ceilings 16X19-Omd:Attic ceiling,mtl roof mat,r-20 roof ins,1/2"gypsum board 1976 0.408 19.0 1.53 3020 1.50 12973 int fnsh Floors 22A-tpl:Bg floor,light dry soil,on grade depth 186 0.989 0 26.7 4967 0 0 wri htsoft' 2017-Jan-3113:49:22 9 Right-Suite®Universal 2017 17.0.16 RSU24011 Page 2 ..nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE I 1 f I 1 DELJ�� © Job: LotffaiponFlats —A.1I"V P;roject Summary Date: 01.18.14 Hume-mcii ilt thdre House By: ER DEL-AIR HEATING & AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32761 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Prooect Information i For,:l Phoenix Realty Homes Inc, Model A FL Notes) Rvsd to 15 seer 12.18.2015 RH RVSD TRANE 16 SEER 11/29/2016 NMB LS 1/31/17 JA i Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily.range L Relative humidity 50 % Moisture difference 59 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26727 Btuh Structure 27798 Btuh Ducts 5780 Btuh Ducts 4064 Btuh Central vent(58 cfm) 1721 Btuh Central vent(58 cfm) 988 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34228 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32850 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2734 Btuh Ducts 3286 Btuh Central vent (58 cfm) 2339 Btuh Heating Coolingg Outside air Area(ft2 1976 1976 Equipment latent load 8358 Btuh Volume(ft3) 18431 18431 Air changes/hour 0.26 0.14 Equipment total load 41208 Btuh Equiv.AVF(cfm) 80 43 Req.total capacity at 0.76 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR6048H1 Cond 4TWR6048H1 AHRI ref 7563627 Coil TEM6AOD48H41++TDR AHRI ref 7563627 Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER Heating*input Sensible cooling 35720 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 11280 Btuh Temperature rise 26 OF Total cooling 47000 Btuh Actual air flow 1567 cfm Actual air flow 1567 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.44 in H2O Static pressure 0.44 in H2O i Space thermostat Load sensible heat ratio 0.80 Capacity balance point=36 OF Backup: Input=0 kW, Output=0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- wrilghtsoft• 2017-Jan-31 13:49:22 � Right-Suite®Universal 2017 17.0.16 RSU24011 Page 1 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE a �I I ' DEL:AIR Right-J®Worksheet Job: Lot6TarponFlats Entire House Date: 01.18.14 DEL-AIR HEATING &AIR By: ER 9PFax:531 CODISCO WAY,SANFORD,FL 3277 hone:407-333-2665 407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Entire House Mstr Bdrm 2 Exposed wall 186.0 ft 41.0 ft 3 Room height 9.3 ft 9.3 ft heat/cool 4 Room dimensions 16.0 x 15.0 ft 5 Room area 1975.5 ft2 240.0 ft2 Ty Construction 'U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/Wz*F) (BtutVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 2ocs a 0201 :ne 5 43' 4 98 345 240 1304 _ 1197 0 0 0 ,0 2A 2om ' 0660-ne 17:82 27 79 6 0 149 232 0 0 0 `0' �2A 2om O'660 he. . 17 82 : 27 79 31 0 5S2 881 0 0 0 0 2A tom 0.660 ne 17 82 27 79 31; :0 552 851 0 0 0 0; 11 262fm 0.660 "rie- 1782 ,r_32.15 11! ,A 190 343 0 0 0 (`0' __0 AlD0_ _ 0 390-ne L .,10:53">" ,,.11,43 29 __ 24 ?53 w 274 __.0 r 0 'L-G13A-2ocs 0.201 se 5.43 4.98 453 413 2239 2056 140 140 760 697 2A 2om 0.660 se 17.82 23.34 13 16 238 311 0 0 0 0 2A 2om 0.660 se 17.82 23.34 27 31 475 622 0 0 0 0, `13A 2ocs 0201 sw` :4 4 98 650 300 163f1 1497 149f 84 455 18 2A 2om 0860 sw"= 1782, 2524 3d 31 &02 853 34 16 602 853 2A 2om i 0.660 sw 1782 v 25.24 39 29 564� 799 ;;32 15 584 799'. 2A 2om 0660 sw 17.82 2213 2A 2om 0660 sw' Y7$2 15 02 51' 101 „'9Q3 761 0 :` . 0 0 0 2A.2omd .__. 1.016 sw_-._2727.; 2i 94, 96 192-__ .2618 �_w 107... ._0 __0 2_v..0. 13A-2r-s 0.201 nw 5.43 4.98 387 361 1958 1798 93 73 398 365 i--G tOC-m 0.660 nw 17.82 22.51 20 0 356 450 20 0 356 450 III------CGGi 2A 2om 0.660 nw 17.82 2779 6 0 113 176 0 0 0 0 12C-0sw 0091 246 ` 1 62 336 315 773 510 0 0 0 0 0390 �nw 10 53" 1Y.43� 21: a 21_ 225_ 244 C 16X19-0md 0.408 1.53 1.50 1976 1976 3020 2973 240 240 367 361 F '22ASpl . .. ..._. _ .._._.., ., ._ -. �a= u._ 777777 6 c)AED excursion 2520 821 Envelope loss/gain 24358 22286 4597 4765 12 a) Infiltration 2370 732 522 161 b) Room ventilation 0 0 0 10 13 Internal gains: Occupants @ 230 5 1150 1 1 230 Appliances/other 3630 600 Subtotal(lines 6 to 13) 26727 27798 5119 5756 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26727 27798 5119 5756 15 Duct loads 22% 159/6 5780 4064 22%1 15% 1107 842 Total room load 1&2Air required(cfm) 13%7 37 s 6598 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed L 'F Wrightsa t' 2017-Jan-31 13:49:22 Right-Sulte®Universal 2017 17.0.16 RSU24011 Page 1 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE I `DEL:AIR Right-J®Worksheet Job: Lot6TarponFlats rmere`.msararnaa+s Entire House Date: 01.18.14 DEL-AIR HEATING &AIR By: ER 531 CODISCO WAY,SANFORD,FL 32771 POhNrD40077ION6NCax:407-333-3853 Web:WWW.DEL-AIR.COM r 1 Room name Mstr WC Mstr WIC 2 Exposed wall 6.0 It 0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room 5 Room area nsions 24.0 ft2 4.0 x 6.0 ft 6.0 x 11.5 It 69.0 ft2 Ty Construction ,B value Or HTMz Area (ftz) Load Area (ft2) Load number ( F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 :13A2ocs = 0201 ne- 543 498 l7' l3 0 0 0 0 0 0 2A 2om O f60 ne 1782: 27 79 0 0 0 0 0 0 0: 2A2om .`` 0660 met Y782 - 0 _0 '0 2779 -0 0 0 0 0 ; 2A 2om _ 6 660 ne 17 82 27 79 0 0 0 0 0 0 11 2B 2fm -y 0 fi60 ne 17 82 3215 __ 00 '0 0 0 Q` 1i43 °0 0 .___ _,w_0 _. 0. 13A 2ocs 0.201 se 5.43 4.98 56 43 231 213 0 0 0 0 2A 2om 0.660 se 17.82 23.34 13 8 238 311 0 0 0 0 2A tom 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 13A 2acs 0.201 sw 5 43 4 98 0. _- U 0 0 0 0 0` 2A 2om �� 0 660 sw• 17 82 25 24 0 _0 0 0 0 0 0 2A 2om a 0:660 sw 17 82 25 24 -� 0 0 1) 0 0 0 0 0: 2A 2om 0 660 sw 17 82 2213 0 0 0 0 0 D 0 0: ?A 2om O'660 sw 17 82 15 02 x 0 0 ''D 0 0 0 0 a :2A.2omd 0 OiO Sw_.` ._27.27_x. 21 94 0 ..__ _ .0 _0 0 0 0 __.. U. L13A-2ocs 0.201 nw 5.43 4.98 0 0 0 0 0 0 0 0 —G 10C-rn 0.660 nw 17.82 22.51 0 0 0 0 0 0 0 10 2A 2om 0.660 nw 17.82 27.79 0 0 0 0 0 0 0 0 72C-0sw 0 091 - 2 46 1 62 0�. 0 0 0 0 0 0 0 11DO 0390 n i053 `;...11"43 . _ 0 _ 0 _ __. 0 ,_. '0 C 16X19-0md 0.408 1.53 1.50 24_ 24 37 36 69 69 105 104 777 m -.ram 27 -----�-• ___ --w--N_ �_— -_-_ __.._ _ _.w_ ._..... :ass w , 6 c)AED excursion 42 -3 Envelope loss/gain 666 602 105 101 12 a) Infiltration b) Room ventilation 76 24 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 l) Appliances/other 01 0 Subtotal(lines 6 to 13) 742 625 105 101 Less external load 0 0 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal 742 62 105 100 15 Duct loads 22% 15% 161 91 22% 15/ 23 15 Total room load Air required(cfm) 4444 735 126 115 6 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Aft"*" wrightsoft• -2017Jan-31 13:49:22 Right-Suite®Universal 2017 17.0.16 RSU24011 Page 2 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE i I � MDEL:AIR Right-J®Worksheet Job: Lot6TarponFlats Entire House Date: 01.18.14 By: ER DEL-AIR HEATING &AIR 531 CODISCO WAY,SANFORD,FL32779 one:D40-��2665 ax:407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Mstr Bthnn Great 2 .Exposed wall 12.5 ft 24.5 ft 3 Room height 9.3 ft heat/cool 9.3 ft heattcooi ' 4 Room dimensions 1.0 x 157.5 ft 1.0 x 503.5 ft 5 Room area 157.5 ft2 503.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftZ°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool' 6 13A 2ocs 62 nem 4:98 rv0 0 61 26 14i 129 2A2om,� 660 ne 1782 2179 Q 0p U 0 0 0 00'. 2A tom �0!660 66: 17.82 27.7$ 0 0, 0 0 0 0 0 0 2A tom D.660 ne 1782 27 79` U 0 0 0 _ 0 0 0 p 11 26 2fm 0:660 no 1782E 3215 0 0 0 0 11 0 180 �343` 0:3� ne 1p531143 ' ._ :Q '0._..aQ .__ _' 0_ .24 24 2532%4 W 13A-2ocs 0.201 se 5.43 4.98 117 90 488 448 0 0 0 1 0 2A tom 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 2A 2om „ 0.660 se 17.82 23.34 27 16 475 622 0 0 0 0 13A 26es 0.201 'sw' 5.43 4 98 _¢ 770 0 S 687777,72 390 359' 2A 2om 0660 `sw _: 17 82 25 24 0 0 0 0 0 0 0 Q 2A2om `_ !. 0:660 sw 1782 '25.24 0 11 fp 0 0 0 0 (} 2A 2om 0660 sw 17 82 22 13 0 0 0 0 0 0 0 0; 2A 2om 0.660 sw= ' 15 02 0 0 fl 0 " 0 0 fl 0' _ 29.2omQ -_ x 1010 uswv 2727_ _ 21:94' w_� 0 ._.2618 _ ZlQ7- 13A-2ocs 0.201 nw 5.43 4.98 0 0 0 0 0 0 0 1 0 V 10C-m 0.660 nw 17.82 22.51 0 0 0 0 0 0 0 ! 0 2A 2om 0.660 nw 17.82 27.79 0 0 0 0 0 0 0 0 12C Osw 0"091 2 46 1 62 -0 0 0 0 0 p p p 11p0 u 0390 n A '.. a1.43 C 16X19-0md 0.408 153 150 158 158 241 237 504 504 770 758 25 .26.Z0 Q.00=58� a,- a e.� Z. 777 77 6 c)AED excursion 78 673 Envelope loss/gain 1538 1385 5016 4t 42 12 a) Infiltration 159 49 312 96 b) Room ventilation 0 01 0 � 0 13 Internal gains: Occupants @ 230 0 0 3 690 Appliances/other 0 1230 Subtotal(lines 6 to 13) 1697 1435 5328 6859 Less external load 0 0 0 i 0 Less transfer 0 0 0 '0 Redistribution 0 0 0 0 14 Subtotal 1697 1435 5328 6859 15 1 Duct loads 220/6 15/ 367 210 22°/u 151/6 1152 1003 Total room load Air required(cfm) 1200 168 63312 986� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed _rk- Wrilghtsoft- Right-Suite®Universal 2017 17.0.16 RSU24011 2017-Jan-31 13:49,:22 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE Page 3 i II i iDJob: Lot6TarponFlats EL AIR Right-J®Worksheet "° `�� Entire House Date: 01.18.14 DEL-AIR HEATING &AIR By ER !CQ Fax:q 531 CODISCO WAY,SANFORD,FL 32771 hone:407-333-2665 407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Nook Bdrm 3 2 Exposed wall 18.0 ft 26.5 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 127.0 ft 1.0 x 199.0 ft 5 Room area 127.0 ft2 199.0 ftz Ty Construction U-value Or HTM Area (ftq Load Area (ftq Load number �Btuh/11:2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 137\2ocs Q201 neW 543 498 A 2A 2om fl 660 ne 1782 2779 Q 0 fl 0 a 0 0 0' 2�2om fl660 ne i782 2779 0 0 0 0 2A 2om 0 660 ne 17 82 27 79 0 0ff 0 0 0 11 2fm a660 ne: i782 32 l5. 0 0 0 a a 0 _..03 _.ne` 1fl.53 ...1i.93 :a .- mo fl .. ... Q ......._.a_ a ......_ fl :0 y1 13A 2ocs 0.201 se 5.43 4.98 0 0 0 0 0 0 0 0 2A 2om 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 2A 2om 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 13A toes 02ai sw 7778.43 4 98 i1�2 E 61 305 i21 83 441T5 2A 2om a xy 0 660 sw 17 82 t 25 24 " a 0 0 Q a r 0 fl a 2A 2om 0 660 sw 17 82 25 24 0 0 0 0 R 0 0 0' ?A 2om sw p86i sw , i7 82; 2213 it 0 0 0 38 18677 841= 2A 2om {3 66� 17.82 15 02 = 51; 51 903 61 7 0 0 a r 2727. 21.94 _._.. U . _, <_.:4._.<�,�_,_ a.....b 0 . .,.W 0 0 = V�1 13A-2ocs 0.201 nw 5.43 4.98 56 56 304 279 126 126 684 628 f -G 10C m 0.660 nw 17.82 22.51 0 0 0 0 0 0 0 0 I--G 2A 2om 0.660 nw 17.82 27 79 0 0 0 _0 0 0 0 10 iz12C a.os1 246; i 62 11 0 0 s0 37 5 37 92 60' 11A0._Osw _-.. _, a390 C 16X19-0md 0.408 1.53 150 127 127 194 191 199 199 304 299 .2,12Z 27 tr y : FW.:.- + .,.�,.._. . ....�.,, ,�_, w._ .. _...__ -.... _- _ ._, 711 �_- .....,a...w.... ...dwzM ......,µ a_._._-, - mow•, ...,.w.....u.'a.: .... .z.�..........m �m � 2.. 7 7 ..<.... w.....¢.....,...... «<«,...u_....__ ,_,-. van......«, 02 71 7. ___._> .....« < ......«�....,. _r.<„ -. .. .....•.naa...._ Fes, ......r -v...,a....<,... ,. s.............,...n..a.^a. �..«.,.,,,,_ .., " .,a..aw...... ..__:.<.r.-�...: ....<.a...s...- .........n...a.�:s _.-....a.v..:�...s, ....... .-.... _,...:....<.....x...<.......,.. _,_- ,,....ana:.x_.a ,....z.w .,.«....... u..._......_... nw..........:. ....<,..<.w".:._._ ..........n..,,,..- .�W...e...a.-x. ,_ .. ...:. ...........w...fA..•. Ma>. .. wi..s 6 c)AED excursion 485 375 11 Envelope loss/gain 2214 2022 2916 2619 12 a) Infiltration 229 71 338 1104 b) Room ventilation 0 0 0 10 13 Internal gains: 'Occupants @ 230 1 230 0 1 0 !Appliances/other 0 1 0 Subtotal(lines 6 to 13) 2443 2322 3254 27,23 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2443 2322 3254 2723 15 Duct loads 22%1 15%1 528 340 22% 15% 704 398 Total room load 2972 2662 3958 31121 Air required(cfm) 143 131 191 154 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Aft_rk- Wf ilght60Tt' 2017-Jan-31 13:49:22 Right-Suite®Universal 2017 17.0.16 RSU24011 Page 4 nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE i I I DEL:AIR Right-M Worksheet Job: Lot6TarponFlats Entire House Date: 01.18.14 r DEL-AIR HEATING &AIR By: ER CONDITIONING 531 CODISCO WAY,SANFORD,FL 3277 one:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Bthrrn 2 Kitchen 2 Exposed wall 6.0 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 11.0 x 14.5 ft 5 Room area 60.0 ft2 159.5 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/Wz*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 8 13A Zoos 0:201 ,no. 5 43• 4 98 0 0 0 0 0 0 0 0 2A 2om O',660 ne 17 82. 27 79_ 0 0 0 0 0 0 0 0 2A 2om 0;660 rie_ 1T82 27:79 0 0 0 0 D 0 0 0' 2A 2om _ni 17:82 27;79 0 0 0 0 0 0 0 =0 11 2B 2tm 0.660 ne; 17.82 32.15_ 0 =•p 0 0 0, 0 0 0 10.53 i ..11:. 0 13A-2ocs 0.201 se 5.43 4.98 0 0 0 0-. 0 0 0 0 2A-2om 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 2A 2om 0.660 se_ 17.82 23 34 0 0 0 0 0 0 0 0 13A 2ocs_ 0201 sw'- 5.43 4.98;� �0 00 0 0 _ 0 0 - 2A-2om -_ 01660'swr; 47.82 25.24.` 00 0 0 0 _. 0- 0 -, Q 2A 2om �� 0;860 sw- 17.82 �25.24 0 0 0 0 0 0 0 :0 2A 2om 0 560 sw 17 82 2213 ; 0 0 0 0 0 0 0 0 2A2ptp �� O'660 sw 1782 1602 .0 00 0 0 0 0p' �1 13A-20cs 0.201 nw 5.43 4.98 56 50 269 247 0 0 0 0 �G 10C-m I 0.660 nw 17.82 22.51 0 0 0 0 0 0 0 0 �--(a 2A 2om 0 660 nw 17.82 27.79 6 0 113 176 _ 0 0 0 0 "!2C Osw 0 091 2.46 Y 162 12& 126 309 N204 ^^v T T107 107 264 W 174' i1 D0 0390 n 10 53 " 0 0 0 0 0 C 16X19-0md 0.408 153 150 60 60 92 90 160 160 244 240 F 22A_tpi_m 0,989__-„,w 26,70 .000 160 : 0 160_._ w 5=.0=x Z 77, _.- ..... 6 c)AED excursion 75 49 Envelope loss/gain 944 793 507 365 12 a) Infiltration 76 24 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 1020 816 507 1565 Less external load 0 0 0J1763 Less transfer 0 0 0 Redistribution 0 0 0 14 Subtotal 1020 816 507 15 Duct loads 22% 15% 221 119 220 15% 110 Total room load 1241 936 617 Air required(cfm) 60 46 30 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed . A'*' wrightsOft' Right-SulteO Universal 2017 17.0.16 RSU24011 2017-Jan-31 13:age 5 Page 5 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE I i ``DEL-AIR Right-J®Worksheet Job: Lot6TarponFlats Entire House Date: 01.18.14 By: ER DEL-AIR HEATING &AIR C�p Fax:531 CODISCO WAY,SANFORD,FL 3277 hone:407-333-2665 407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Utility Bdrrn 2 2 Exposed wall 6.5 ft 27.0 ft 3 Room height 9.3 ft heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 52.5 ft 1.0 x 178.5 ft 5 Room area 52.5 ft2 178.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/Wz*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Ccol Gross N/P/S Heat Cool Gross N/P/S Heat Cool] 6 13A 2ocs` 0201 ne 5 49: 4 98: 61' 52 284 261 ' 112 81 439 403 2A 2om O,�D ne 17 82= 27.79 8 0 149 232 0, 0 0 0: 2A 2om „"O;fi60 ne` 17.B2 r 27.79 b 0 0 0 ."861 2A 20m 1 _0;660 ne; 17.82 2T79 0 `0 {0 0 0 0 D p 11 2B 2fm 0.660 fie 1T82: 3215 0 0 0 0 0 0 0w0 11DQ_ ,.0:390 arse,,_J0,53 _ li:43 yl 13A-2ocs 0.201 se 5.43 4.98 0 0 0 0 140 140 760 697 I�G 2A-2om 0.660 se 17.82 23.34 0 0 0 0 0 0 0 0 2A 2om 0,660 se 17.82 23.34 0 0 0 0 0 0 0 0 . 13A2ocs 6201 sw�. 0 0 2A 2om 0;660_sw, 17.82 25:24 ,A 0 0 0 0 0 0 6 2A 26m 0 660=sw, -17:82 25.24 d 0 0 - 0 0 0 0 .. 0 2A 2om - ;0;66D'sw 17.82�;�2213' 0 .0 0 �.0 - :0.. 0 0 ;0: 24 2om_ 0 660 sw, 17.82 15.02' 0 0 0 0 0 0 0 0 TIL",:_J:.010,°sw_,..._.27..27_ w21.94 _ .�_Q _ -0 0 __ ,0 .9 0._ _.' R_ 0. Vf/ 13A-2ocs 0.201 nw, 5.43 4.98 0 0 0 0 0 0 0 0 10C-m 0.660'rnw 17.82 22.51 0 0 0 0 0 0 0 0 2A 2om 0.660 nw 17 82 27 79 0 0 0 0 0 0 0 0 FFjj 12C-0sw 0091 mm 2 46 1 62 65 44 108 71 0 0 0 0, rtw_ _.10.53 11.43 _ 21; _...�_21._..>,_.,,_'225_ 244 0 _ __._0 __._0 0 C 16X19-0md 0.408 153 150 53 53 80 79 179 179 273 269 _.,.__._,_174=:___0 _ __ 6 c)AED excursion -46 -71 Envelope loss/gain 1019 840 2745 2159 12 a) Infiltration 83 26 344 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 0 Subtotal(lines 6 to 13) 1102 14MI 3089 2266 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redstribution 0 0 0 0 14 Subtotal 1102 1466 3089 2266 15 Duct loads 22% 15% 238 214 22% 15% 668 331 Total room load 1340 1680 3757 2597 Air required(cfm) 65 63 181 128 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed rCA� Wf ight50ft' 2017-Jan-31 13:49:22 A Right-Suite®Universal 2017 17.0.16 RSU24011 Page 6 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE ] ] ] '' DEL:AIR Right-J®Worksheet Job: LoWarponFlats " ROM-AM90 Entire House Date: 01.18.14 By: ER DEL-AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM 1 Room name Bdrm 4/Den Bthnn 3 2 Exposed wall 18.0 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 it heat/cool 4 Room dimensions 12.0 x 12.5 ft 10.0 x 5.5 ft 5 Room area 150.0 ftz 55.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/Wz*F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cocl Gross N/P/S Heat Cool Gross N/P/S Heat Coolj 6 13A 2ocS 0;20i _ne 5 43° 4 98 i12 81 439 403 0 0 0 0 :2A 2om 0;660 ne- 17.82 27 79 q 0 0 0 0 0 0 0 2om 0.660 ne. 7.82: 27 79 0 0 0 0 0 - 0 0 0 2A 2orr y 0660 "ne` i .82 2779 31' �;0 552 =861 0 0 0 4 2fm i0 860`ne- 1T82; ,::32.15�_ 0 0 .0 0 = 0 .. 11A0 "__...0 3 39t1 rlem? ]0.53 �1�Q_d._, 0 v_0._ 0 13A 2ocs 0.201 se 5.43 4.98 0 0 0 0 0 0 0 0 2A 2om 0.660 se 17.82 23.34 0 0 0 0 0 0 0 1 0 2A 2om 0 660 se 17 82 23 34 0 0 0 0 0 0 0 0 13A 2oCS t - _ a2ii1 i sw. 5 43.r a.98` 6 0 0 =:0 0 0 0i)' 2A 2om 0660 sw' 1T82' 25.24 Q 0 0 _ 0 0 0 0 Q 2A 2om. O;S6p Svi. 17 82= M24�: �0 0 0 0 0 0 0 2A 2om O'660 sw 1782 0 0 0 0 0 0 0 0 2A 2om _ 0 660 ,sw 17.82 16 02 0 b 0 0 0 0 -2omd_ _ _,ti a 9 Ot0 sww _2727... 21.94 2A .. 0 N.,_. 0 0 _,_9 0 - 0 i Q. 13A 2ocs 0.201 nw 5.43 4 98 56 56 304 279 0 0 0 0 10C m 0.660 nw 17.82 22 51 0 0 0 0 0 0 0 0 ��GCII --GGG 2A 2om 0.660 nw 17.82 27.79 0 0 0 0 0 0 0 0 .� i2C-0sw 0091 1 62=w 0 "0 0 0 0 0 0 U . 1ip0 ft390_A _LA0.53 ,,11,43 �Q wA � __ 0 A _0 L_ n 0 C 16X19-0md 0.408 1.53 1.50 150 150 229 226 55 55 84 83 77777� mow+.::...... �..,...w......._,.........xw.w._...._ dz............. ...C.-.:.'. ..a..w. ..F.,. .- ... � 3 +.., w .-.- -�.....m...w,wu..w_..wwe,... .5... ......... �< a>.._r.... ....,,., en..w..w.w...v. .......,tx ..a. 2, a ,... n.-..,....v ....wn.a ..,�aww ......,,x..., a....« ,,,,i,.w..� a.......uu . c7 6 c)AED excursion -ram I-0 Envelope loss/gain I 2006 1713 84 iI80 12 a) Infiltration 229 71 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2235 1784 1 841 g0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2235 1784 84 80 15 Duct loads 22% 15% 483 261 22% 15% 18 12 Total room load Air required(cfm) 21311 1�011 105 �5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed .4Z`P.'� wrightsoft' 2017-Jan-31 13:49:22 IRlght-SuiteQ�l Universal 2017 17.0.16 RSU24011 Page 7 ..nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE I - I I I i ® Duct System Summary Job: LotffarponFlats DEL-AIR y y Date: 01.18.14 CQN�"0N"6 Entire House By: ER DEL-AIR HEATING & AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Project • • For: Phoenix Realty Homes Inc, Model A FL Heating Cooling External static pressure 0.44 in H2O 0.44 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.38 in H2O 0.38 in H2O Supply/return available pressure 0.190/0.190 in H2O 0.190/0.190 in H2O Lowest friction rate 0.212 in/100ft 0.212 in/100ft Actual air flow 1567 cfm 1567 cfm Total effective length(TEL) 179 ft I SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bdrm 2 h 3757 181 128 0.248 7.0 Ox 0 VIFx 53.0 100.0 st3' Bdrm3 h 3958 191 154 0.343 8.0 Ox0 VIFx 25.8 85.0 st1 Bdrm 4/Den h 2718 131 101 0.262 7.0 Ox 0 VIFx 44.9 100.0 st3 Bthrm 2 h 1241 60 46 0.337 5.0 Ox 0 VIFx 27.7 85.0 st1 Bthrm 3 h 102 5 5 0.273 4.0 Ox 0 VIFx 39.4 100.0 st3 Great c 3931 156 193 0.290 8.0 Ox0 VIFx 31.1 100.0 st3 Great-A c 3931 156 193 0.279 8.0 Ox0 VIFx 36.0 100.0 st3 ' Kitchen c 1793 30 88 0.367 6.0 Ox 0 VIFx 18.5 85.0 sti Mstr Bdrm c 3299 150 162 0.215 7.0 Ox 0 VIFx 61.6 115.0 st4 Mstr Bdrm-A c 3299 150 162 0.212 7.0 Ox 0 VIFx 63.9 115.0 st4 Mstr Bthnn h 2064 100 81 0.225 6.0 Ox 0 VIFx 53.9 115.0 st4 Mstr WC h 903 44 35 0.219 4.0 Ox 0 VIFx 58.1 115.0 st4 Mstr WIC h 128 6 6 0.225 4.0 Ox0 VIFx 53.9 115.0 st4 Nook h 2972 143 131 0.339 7.0 Ox0 VIFx 27.2 85.0 st1 Utility c 1680 65 83 0.345 6.0 Ox 0 VIFx 25.2 85.0 st1 i Supply Trunk - • - 'I Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 449 446 0.212 572 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 1079 1066 0.212 610 18.0 0 x 0 VinlFlx sti sti Peak AVF 1567 1567 0.212 718 20.0 0 x 0 VinlFlx �. �.. �wrlghtsofC Right-SuRerel Universal 2017 17.0.16 RSU24011 2017-Jan-31 13:44:23 AM ...nstruction\Lot6T Page 1 arponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm), (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rbi Ox0 1567 1567 0 0 0 0 Ox 0 VIFx i I I II I C wril htsoft 2017-Jan-3113:49:23 9 Right-Suite®Universal 2017 17.0.16 RSU24011 Page 2 ...nstruction)\Lot6TarponFlats\Lot6TarponFlats.rup Calc=MJ8 House faces:NE I ,I FORM R406-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number. - FL, MANDATORY REQUIREMENTS See individual code sections for full details. +, C3 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitte8 to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. II 13 R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requiremelf nts of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. " 11402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of co truction. Where required by the code official,an approved third party shall inspect all components and verify compliance. R402A.1 2 Testing.-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an ` approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. I During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according toINFRC 400 or AAMAMIDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: 0ite-built windows,skylights and doors. i O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 10 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat'provision(Mandatory).At least one thermostat shall be provided for each separate heating and coaling system. 13 R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. I R403.2.2 Sealing(Mandatory)NII ducts,air handlers,and filter boxes and building cavities that form the primary air containment �I passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance i with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct.tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance Jth Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: I 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. I 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor,area when tested at a pressure differential of 0.1 Inches w.g.(25Pa)across the system,Including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handier is not installed at the time of the test,total leakage shall be less than or equal to 3 cfrn (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1 1/31/2017 1:46 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn ge f 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select waling-only equipment.This y selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. I R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. • R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. • R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. j O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or' at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 1/31/2017 1:46 PM I EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 II I I I li FORM R405-2014 j TABLE 402.4.1.1 i AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA 4 Project Name: Lot6TarponFlats Builder Name: Phoenix Realty Homes Inc Street: Permit Office: City,State,Zip: FL, Permit Number: Owner. Jurisdiction: 661100 j Design Location: FL,Fort Pierce I COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. j Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation ' Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. I Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. it Rim joists Rim joists are insulated and include an air barrier. j Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. rFireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1/31/2017 1:46 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 1 !I i , I FORM R405-2014 Duct Leakage Test Report Performance Method � I � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Lot6TarponFlats Builder Name: Phoenix Realty Homes Inc Street: Permit Office: City,State,Zip: FL, Permit Number: Design Location: FL,Fort Pierce Jurisdiction: 661100 Duct Test Time: Post Construction I Duct Leakage Test Results I • CFM25 Duct Leakage Test Values Line System Outside Duct Leakage • I 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) I 5 Total House Sum lines 1-4 Duct System Leakage Divide by i (Total Conditioned Floor Area) _ (Qn,Out) I I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified b S� not greater than the proposed duct leakage Qn g y O� 4 specified on Form R405-2014. testing to Section 803 of the RESNET Standards by an energy rater certified in 4,= accordance with Section 553.99, Florida Statutes. p SIGNATURE: t'3:. PRINTED NAME: 6'p� .t¢ '� DATE: BUILDING OFFICIAL: DATE: 1/31/2017 1:46 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 �0 i