HomeMy WebLinkAboutInspection Docs INSULATION INSTALLATION CERTIFICATE
TiO. Watlee Construction Inc LOT BLOCK_: SECTION:
JOB#: 110201 JOB NAME: McClory Res
JOB ADDRESS; 633 Nettles Blvd
` The uniiersi�ncd freieby c-ifies'th'at:insulaiign fins°been:inssaped.`a�the�above,desctibi d proprsty as,
follows:
1. Exterior CBS walls have been insulated with............................Check one ( )Spray on cellulose
to a thickness of N/A inches,which thickness,according to the ( )Fiberglass blankets
manufacturer, FiFoil (Xj Aluminum Foil
Density N/A will yield an"R"value of 4.1 ( ) Riaid
Exterior Frame walls have been insulated with............................Check one ( )Spray on cellulose
to a thickness of inches,which thickness,according,to the ( )Fiberglass blankets
manufacturer, ( )Aluminum Foil-
Density N/A will yield an"R"value of ( )Other Spray Foam'
2. Main Ceilings have been insulated with.........................Check one ( )Fiberglass blankets
to a thickness of 5.25 inches,which thickness,according to the ( )Fiberglass loose fill
manufacturer, SES Sucraseal ( )Aluminum Foil
Density NIA will yield an"R"value of 20 (X)Spray Foam
' Ceilings Cathedral have.been insulated with.........................
one ( )Fiberglass blankets
to a thickness of inches,which thickness,according to the O Fiberglass loose fill
manufacturer, O Aluminum Foil
Density N/A will yield an"R"value,of O Other Cellulose
3. Interior knee walls have been insulated with.................................Check one ( )Fiberglass blankets
to a thickness of inches,which thickness,according to the ( )Polyurethane
manufacturer, ( )Spray on cellulose
Density N/A will.yield an"R"value of ( )Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated whh................»,.:..:.,.:.....:.....,...................... ...........:..::Cheek one:: ( )Fiberglass blankets
to a thickness of inches,which thickness,according to the ( )Spray on cellulose
manufacturer, ( )Polyurethane
Density NIA will yield an"R"value of ( )Other Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated as follows-Frame/Metal stud walls R-I I (Min.);CBS or Concrete walls
R-3(Min.);by Energy Code requirements. See Energy Code Rev.1/87,paragraph 903.2(b),on page 9-17,
latest edition. These"minimums levels of insulation"are not included in the Energy Calculations,but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed-on site insulation shall be the P.C.F.
(lb/ft3)average of three(3)"DRY SAMPLES"of actual installatiork
MER Enterprises LLC
Insulation Contractor Insulation Conitractor Signature
MCIN6231 5/26/17
Insulation Contractor's CC# Date of Certification
Builder's Name-Builder's CC# _N P I c'
KELLY L YOUNG
•� A�r,
Notary Public Slate of Florida
E' My Comm.Expires Jul 1.2018'
Commission#FF 138101