Loading...
HomeMy WebLinkAboutProduct Approval 1tL tC Florida Building Code Online Page 1 of 4 • 1 , : e� , > F r d �x 1 ':�54. � z �i�yy CaR.;�� ��`�'� - az�' ♦ � k �� ��µ (g "ti BCIS Home Log In i User Registration j Hot Topics Submit Surcharge i Stats&Facts `s Publications i FBC Staff BCIS Site Map Links i_ Search Flarit"�3 Product Approval USER:Public User COMB FASTENERS OR ATTACHMENTS ' Product Approval Menu>Product or Application Search>Application List>Application N RF-SPONSIBILI Y OF THEtlon Detail ([j�nap t` 4a FL# FL14645-R2 l� �"" '�!�'1`='' n a,p Application Type Revision Code Version 2014 Application Status Approved Comments THESE HESE PLANS AND A ILL PROPOSED g OEIK Archived . ` ARE SUBJECT TO AW1 CORRECT10INS REQUIRE®OY FIELD @NVECTOPS T I°I+ Product Manufacturer Metal Sales Manufacturing CAP I Address/Phone/Email 545 South 3rd Street,Suite`W1Qe'.�� +m ��,y � c FIBi�C Louisville,KY 40202 @' d , o <E a; rr), (812) 218-7342 1�11�� + ;994 P l, 14 ��'PPLICA'21,2 E dstermer@metalsales.us.com Authorized Signature David Stermer dstermer@metaisales.us.com c (� ST VCR COLJN; RITiLnn:C7 nIVISION Technical Representative REWLEWED FOR IIIPL NNE Address/Phone/Email DATE 3 � Quality Assurance Representative PLANS AND PERAnT MUST BE KEPT ON JOB Address/Phone/Email OP NO LN-SIPECTIC N`MILL B NLA;:E. Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer r J: Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Bala Sockalingam the Evaluation Report Florida License PE-62240 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2020 Validated By Yoosef Lavi,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL14645 R2 COI CertificateIndeoendence.Ddf Referenced Standard and Year(of Standard) Standard Year FM 4470 1992 TAS 125 2003 UL 1897 1998 UL 1897 2004 UL 580 1994 UL 580 2006 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14645 R2 Eotliv TestEguivalentC2010 UL odf Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 2/22/2017 Florida Building Code Online• • Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 03/31/2015 Date Validated 04/14/2015 Date Pending FBC Approval 04/18/2015 Date Approved 06/23/2015 Summary of Products FL# Model, Number or Name -Description 14645.1 2.5"Corrugated Min. 26 ga., 21.33" wide coverage through fastened roof panel over min. 19/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 11 EvaluationReportC2010 1..pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86.0 Evaluation Reports Other:Uplift load of 82.3 psf at fastener spacing of 36"o.c. FI.14645 R2 AE EvaluationRepo_rtC201_0 1..pdf and 86.0 psf at fastener spacing of 12"o.c. Created by Independent Third Party:Yes 14645.2 5V-Crimp Min.26 ga., 24 wide through fastened roof panel over min. 19/32"thick plywood deck with fasteners through panel flat. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 fI EvaluationReportC2010 2.1)df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-149.6 Evaluation Reports Other: Uplift load of 84.5 psf at fastener spacing of 24" Fl 14645 R2 AF EvaluationReportC2010 2..pdf o.c., 131.3 psf at fastener spacing of 18"o.c.and 149.6 psf Created by Independent Third Party:Yes at fastener spacing,of 12" o.c. 14645.3 5V-Crimp Min.26 ga., 24"wide through fastened roof panel over min. 19/32"thick plywood deck with fasteners through panel rib. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2. 11 FValuationReportC2010 3.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-196.75 Evaluation Reports Other: Uplift load of 41.6 psf at fastener spacing of 36" FL14 4$ R2 AE Ev?haa7 ionReportC201Q 3.pdf o.c.,74.8 psf at fastener spacing of 16"o.c.and 196.75 psf Created by Independent Third Party:Yes at fastener spacing of 8" o.c. 14645.4 5V-Crimp Min. 26 ga., 24"wide through fastened roof panel over min, 15/32"thick plywood deck or 7/16" thick OSB with fasteners through panel rib. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 4.2df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-172.5 Evaluation Reports Other:Uplift load of 30.0 psf at fastener spacing of 36"o.c. FL14645 R2 AE EvaluationReportC2010 4.odf and 172.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party:Yes 14645.5 Aluminum Classic Rib Nom.0.032" thick,36"wide,aluminum through fastened roof panel over min. 15/32"thick plywood deck or 7/16" thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 5.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-120 Evaluation Reports Other: Uplift load of 30 psf at fastener spacing of 36"o.c. FL14645 R2 AE EValuationReoortC2010 Sxdf and 120 psf at fastener spacing of 6"o.c. Created by Independent Third Party:Yes 14645.6 Aluminum Vertical Seam Nom.0.032" thick, 16"wide,aluminum standing seam roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 11211 Eva IuationReportC2010 6.odf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 2/22/2017 Florida Building Code Online• Page 3 of 4 Design Pressure: +N/A/-97.05 Evaluation Reports Other: Uplift load of 41.55 psf at clip spacing of 36" o.c., FI 14645 R2 AF EvaluationReportC2010 6.pdf 71.0 psf at clip spacing of 12"o.c.and 97.05 psf at clip Created by Independent Third Party: Yes spacing of 12"o.c.with sidelap adhesive. 14645.7 Aluminum Vertical Seam Nom.0.032" thick, 16"wide,aluminum standing seam roof panel over min. 19/32"thick plywood deck Limits of Use Installation Instructions Approved for use in HVHZ: No I°I 14645 R2 II EvaluationReportC2010 7.odf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-162.0 Evaluation Reports Other:Uplift load of 41.55 psf at clip spacing of 36" o.c., FL14645 R2 AE Evalu� ionRenortC2010 7.pdf 100.2 psf at clip spacing of 12"o.c.and 162.0 psf at clip Created by Independent Third Party: Yes spacing of 12"o.c.with support strap. 14645.8 Classic Rib Min. 26 ga., 36"wide through fastened roof panel over min. 19/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14('4! R2 II EvA1-vationReportC2010 8.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-133.9 Evaluation Reports Other: Uplift load of 74.8 psf at fastener spacing of 36" FL14645 R2 AE EvaluationReportC2010 8.1)df o.c.,92.3 psf at fastener spacing of 24"o.c.and 133.9 psf Created by Independent Third Party: Yes at fastener spacing of 18"o.c. 14645.9 Classic Rib Min. 29 ga., 36"wide through fastened roof panel over min. 7/16"thick OSB deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 9.1)df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-135.0 Evaluation Reports Other: Uplift load of 45 psf at fastener spacing of 24"o.c. FL14645 R2 AE EvaluationReportC2010 9.i)df and 135 psf at fastener spacing of 6"o.c. Created by Independent Third Party:Yes 14645.10 Classic Rib Min.29 ga., 36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 10.1)dF Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-138.5 Evaluation Reports Other: Uplift load of 68.4 psf at fastener spacing of 24"o.c. FL14645 R2 AE EvaluationReportC2010 l0.odf and 138.5 psf at fastener spacing of 12"o.c. Created by Independent Third Party:Yes 14645.11 Image II Min. 26 ga., 16"wide concealed fastened roof panel over min. 15/32"thick plywood deck or 7/16"thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL1 i6h5 R2 II Ev._�lua_tignRPportC�Q10 ,ii.pcif Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86.55 Evaluation Reports Other:Uplift load of 20.75 psf at fastener spacing of 24" FL14645 R2 AE EvaluationReportC2010 ll.pdf o.c.,63.50 psf at fastener spacing of 6"o.c.and 86.55 psf Created by Independent Third Party:Yes at fastener spacing of 6"o.c.with sidelap adhesive. 14645.12 PBR-Panel or R-Panel Min.26 ga., 36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 I1 EvaluationReportC2010 12.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: +N/A/-131.0 Evaluation Reports Other: Uplift load of 30.0 psf at fastener spacing of 48"o.c. FL14645 R2 AE Eva luationReportC2010 12.odf and 131.0 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes 14645.13 Pro-Panel II Min. 29 ga., 36"wide through fastened roof panel over min. 15/32"thick plywood deck. Limits of Use Installation Instructions Approved for use in HVHZ: No FL14645 R2 11 EvaluationRenortC2010 19 odf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-71.5 Evaluation Reports Other: Uplift load of 41.6 psf at fastener spacing of 24"o.c. FL14645 R2 AE EvaluationReportC2010 13 odf and 71.5 psf at fastener spacing of 12"o.c. Created by Independent Third Party: Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 2/22/2017 Florida Building Code Online Page 4 of 4 Sack Nezt Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.r'oovriah[2007-2013 State of Florida.::Privacy Statement::A ibili��.SyGtatement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-maii address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click her . Product Approval Accepts: ......... ........_........ Credit Carr Safe 1 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 2/22/2017 ' r EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA.5V-CRIMP PANEL' FLORIDA BUILDING CODE 5TH EDITION(2014) FLORIDA PRODUCT APPROVAL FL 14645.2-R2 ROOFING , METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street,Suite 200 Louisville,KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida Professional Engineer#62240 1216 N Lansing Ave.,Suite C Tulsa,OK 74106 Telephone: (918)492-5992 FAX: (918)493-3568 This report consists of Evaluation Report(3 Pages including cover) Installation Details (1 Page) --`**S0CKAQ& v •• No -2240 ' r Report No. C2010-2 Date: 3.27.15 C•�' STATE CF � �i Q••• ,�• P,•'�e� erg` { 41 3•'3C1. '2.�t�"" • FL 14645.2-R2 C2010-2 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) 131.3 psf @ fastener spacing of 18" o.c. 149.6 psf @ fastener spacing of 12" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through-the deck a minimum of 3/8". At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between ribs) At intermediate 4 fasteners per panel width. (4 located adjacent to ribs) Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation..Report. Refer to FBC 2014 Section 1505 and current approved `roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. • FL 14645.2-R2 C2010-2 3.27.15 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No.T235-07, Reporting Date 7/12/07 Project No.T172-08,Reporting Date 4/29/08 i' • e Daum Daum vn � os. .FASTENER aO.• wn PANEL SEE DETAIL 1 �- /=ins P SPACING PER LE.OWABLE 5V—CRIM PRESSURE TABLE k "' � . 3 19 UNDERIA MENT SHALL BE INSTALLED PLYWOOD MINIMUM ATTACHMENT: 19/32'THICK (MIN.) AS PER MANUFACTURER'S INSTALLATION 8d x 7 5" LONG RING SHANK NAIL MIN. 2X— WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD & AT PLYWOOD EDGES FASTENER PATTERN AT INTERMEDIATE LOCATIONS 24" d 5V—CRIMP SEE DETAIL 1 U N \ i t�-I- D 0 0 x � NI UNDERLAYMENT SHALL BE INSTALLED m AS PER MANUFACTURER'S INSTALLATION MINIMUM ATTACHMENF: 19/32" THICK (MIN.) n�Ogo 8d x 2.5" LONG RING SHANK NAIL J N MIN: 2X— WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS ? N TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD & 09 AT PLYWOOD EDGES FASTENER PATTERN AT PANEL ENDS TYPICAL PANEL INSTALLATION 'X-SECTION ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE L4 2 SPACING (PSF) a (IN) p u #9-16 OR #10-14 WOODSCREWS 24 84.5 a a ��� WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 24" O.C. 18 131.3a SV-CRIMP 12 MIN 26 GA. ln H GENERAL NOTES: , 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. UNOERLAYMENT PLYWOOD 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS 19/32" THICK (MIN.) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM q D ETAI L 1 REQUIREMENTS'OF THIS DRAWING & THE CODE,.THE CODE SHALL CONTROL 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS 2010-2 REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. %iEEr 1 OF 1