NOTICE OF ACCEPTANCE (NOA) %viy .miamidad&zav1eeonomX
Entegra Roof Tile,LLC
1289 NE 91b Ave
Okeechobee,FL 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement_ Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
j in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA#14-1120.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMi DADE COUNTY
NOA No::15-0721.04
Expiration Date:12/08/20
Approval Date:11/05/15
Page 1 of 7
S
ROOFING.ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
1. PRODUCT DESCRIPTION
Manufactured by Dimensions Test Product
Applicant Specifications Description
Plantation Tile Length: 16YV TAS 112 Flat concrete roof tile for direct deck or
Width: 13" battened nail-on,mortar or adhesive set
applications.
Trim Pieces L=varies TAS 112 Accessory trim,concrete roof pieces for
W=varies use at hips,rakes,ridges and valley
Varying thickness terminations. Manufactured for each file
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee,FL
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
American Test Lab of South RT0624.05-14 TAS 112 07/03/14
Florida
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III PA 102&PA 102(A)
The Center for Applied 94-060B Static Uplift Testing March, 1994
Engineering,Inc. 94-084 PA 101 (Adhesive Set) May 19.94
(Mortar Set)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix 1I PA 108(Nail-On)
Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994
PA 108(Nail-On)
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
PA 108(Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs.smooth shank nails
The Center-for Applied Project No.307025 Wind Driven Rain Oct. 1994
Engineering,Inc. Test#MDC-76 PA 100
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
April 1999
Walker Engineering,Inc. Calculations 25-7183 March 1995
25-7094 February 1996
25-7496 April 1996
NOA No.:15-0721.04
MAMMADECOUNTY Expiration Date:12/08120
Approval Date: 11/05/15
Page 2 of 7
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Renort Date
Walker Engineering,Inc. Calculations 25-7584 December 1996
25-7804b-8
25-7804-4&5
25-7848-6
Walker Engineering,Inc. Calculations Two Patty Adhesive Set System April 1999
Farabaugh Engineering and T295-11 TAS-108 10/05/11
Testing Inc.
Farabaugh Engineering and T306-11 TAS-108 10/04/11
Testing Inc.
Farabaugh Engineering and T279-11 TAS-108 09/23/11
Testing Inc.
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications,a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.:15-0721.04
MLAMIOADECOUtmm Expiration Date:12/08/20
Approval Date: 11/05/15
Page 3 of 7
4. INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118,RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W)and Dimensions(I x w)
Tile Profile Weight-W(Ibf) Length-[(ft) Width-w(ft)
Plantation Tile 11.6 1.375 1.08
Table 2: Aerodynamic Multipliers -7.(0)
Tile %(ft3) X(ft3)
Profile Batten Application Direct Deck Application
Plantation Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity-M (ft-Ibf)
Tile Greater than
Profile 2": 12" 3":12" 4": 12" 5": 12" 6": 12" 7":12"
Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
Deck Deck Deck Deck Deck Deck
Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04
Tile
i
ill .
NOA No.:15-0721.04
MIAMI-DADE COUNTY Expiration Date:12/08/20
Approval Date:11/05/15
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-ibf)
For Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (Min 15132" (Min. 19132"
plywood) plywood)
Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2
Nails
1-10d Smooth or 7.3 9.8 4.9
Screw Shank Nail
2-10d Smooth or 14.0 18.8 7.4
Screw Shank Nails
1 #8 Screw 30.8 30.8 18.2
2#8 Screw 51.7 51.7 24.4
1-10d Smooth or 24.3 24.3 24.2
Screw Shank Nail-
Field Clip)
1-10d Smooth or 19.0 19.0 22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or 35.5 , 35.5 34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or 31.9 31.9 32.2
Screw Shank Nails
Eave Clip)
2-10d Ring Shank 50.3 65.5 48.3
Nails'
1 Installation with a 4'tile headlap and fasteners are located.a minimum of 2W from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile Tile Application Minimum Attachment
Resistance
Plantation Tile Adhesive 31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weights per patty 13.9 grams.
3M-2-Component Foam Roof Tile Adhesive AH-160.Average weight per patty 8 rams.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
For Single Patty Adhesive Set S stems
Tile Profile Tile Application Minimum Attachment Resistance
Plantation Tile 3M'2-Component Foam Roof Tile Adhesive AH-160 118.94
3M-2-Component Foam Roof Tile Adhesive AH-160 40.4s -
4 Large paddy placement of 45 grams of 3W 2-Component Foam Roof Tile Adhesive AH-160
S Mediumbaddy placement of 24 grams of 3M'2-Component Foam Roof Tile Adhesive AH-160.
NOA No.:15-0721.04
MIAMI-DADE COUNTY Expiration Date:12/08/20
Approval Date: 11105/15
Page 5 of 7
Table 7:Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar Set Systems
Tile Profile Tile Application Attachment
Resistance
Seespecific mortar manufacturer's Notice of Acceptance:
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade CountyProduct Control Approved".
OR
ENTEURA
PLANTATION ROOF TILE LABEL(LOCATED ON UNDMSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance. ,
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.:15-0721.04
MIAMI•DADECOUNTY Expiration Date:12/08120
Approval Date:11/05/15
Page 6 of 7
PROFILE DRAWING
PLANTATION FLAT CONCRETE TILE
I6
END OF THIS ACCEPTANCE