Loading...
HomeMy WebLinkAboutNotice of Acceptance � t •a��:i ,;J3 �v 1%tL"I DADE COUNTY MIAMI.- - PRODUCT CONTROL SECTION • kgliiilal 11805 SW 26 Street,Room 208 DEPARTiVENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADAUNISTRATION DIVISION T(786)315-2590 F(786)315 2599 NOTICE OF ACCEPTANCE (NOA) %viy .miamidad&zav1eeonomX Entegra Roof Tile,LLC 1289 NE 91b Ave Okeechobee,FL 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement_ Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change j in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA#14-1120.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMi DADE COUNTY NOA No::15-0721.04 Expiration Date:12/08/20 Approval Date:11/05/15 Page 1 of 7 S ROOFING.ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Plantation Tile Length: 16YV TAS 112 Flat concrete roof tile for direct deck or Width: 13" battened nail-on,mortar or adhesive set applications. Trim Pieces L=varies TAS 112 Accessory trim,concrete roof pieces for W=varies use at hips,rakes,ridges and valley Varying thickness terminations. Manufactured for each file profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee,FL 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0624.05-14 TAS 112 07/03/14 Florida Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102&PA 102(A) The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering,Inc. 94-084 PA 101 (Adhesive Set) May 19.94 (Mortar Set) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix 1I PA 108(Nail-On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108(Nail-On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108(Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs.smooth shank nails The Center-for Applied Project No.307025 Wind Driven Rain Oct. 1994 Engineering,Inc. Test#MDC-76 PA 100 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 April 1999 Walker Engineering,Inc. Calculations 25-7183 March 1995 25-7094 February 1996 25-7496 April 1996 NOA No.:15-0721.04 MAMMADECOUNTY Expiration Date:12/08120 Approval Date: 11/05/15 Page 2 of 7 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Renort Date Walker Engineering,Inc. Calculations 25-7584 December 1996 25-7804b-8 25-7804-4&5 25-7848-6 Walker Engineering,Inc. Calculations Two Patty Adhesive Set System April 1999 Farabaugh Engineering and T295-11 TAS-108 10/05/11 Testing Inc. Farabaugh Engineering and T306-11 TAS-108 10/04/11 Testing Inc. Farabaugh Engineering and T279-11 TAS-108 09/23/11 Testing Inc. 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.:15-0721.04 MLAMIOADECOUtmm Expiration Date:12/08/20 Approval Date: 11/05/15 Page 3 of 7 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W)and Dimensions(I x w) Tile Profile Weight-W(Ibf) Length-[(ft) Width-w(ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers -7.(0) Tile %(ft3) X(ft3) Profile Batten Application Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity-M (ft-Ibf) Tile Greater than Profile 2": 12" 3":12" 4": 12" 5": 12" 6": 12" 7":12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile i ill . NOA No.:15-0721.04 MIAMI-DADE COUNTY Expiration Date:12/08/20 Approval Date:11/05/15 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-ibf) For Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 15132" (Min. 19132" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2#8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail- Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail Eave Clip) 2-10d Smooth or 35.5 , 35.5 34.8 Screw Shank Nails Field Clip) 2-10d Smooth or 31.9 31.9 32.2 Screw Shank Nails Eave Clip) 2-10d Ring Shank 50.3 65.5 48.3 Nails' 1 Installation with a 4'tile headlap and fasteners are located.a minimum of 2W from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 31.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. 3M-2-Component Foam Roof Tile Adhesive AH-160.Average weight per patty 8 rams. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) For Single Patty Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile 3M'2-Component Foam Roof Tile Adhesive AH-160 118.94 3M-2-Component Foam Roof Tile Adhesive AH-160 40.4s - 4 Large paddy placement of 45 grams of 3W 2-Component Foam Roof Tile Adhesive AH-160 S Mediumbaddy placement of 24 grams of 3M'2-Component Foam Roof Tile Adhesive AH-160. NOA No.:15-0721.04 MIAMI-DADE COUNTY Expiration Date:12/08/20 Approval Date: 11105/15 Page 5 of 7 Table 7:Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Seespecific mortar manufacturer's Notice of Acceptance: 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami-Dade CountyProduct Control Approved". OR ENTEURA PLANTATION ROOF TILE LABEL(LOCATED ON UNDMSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. , 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.:15-0721.04 MIAMI•DADECOUNTY Expiration Date:12/08120 Approval Date:11/05/15 Page 6 of 7 PROFILE DRAWING PLANTATION FLAT CONCRETE TILE I6 END OF THIS ACCEPTANCE NOA No.:15-0721.04 MMI•DADeCOUNr�r Expiration Date: 12/08/20 Approval Date:11/05/15 Page 7 of 7