Loading...
HomeMy WebLinkAboutREVISED-A2 12.11.20BRG. PARTITION WALL - 4" (U.N.O.)1/2" GYP. BD. ON EACH SIDE OF 2x4 WD. STUDS @ 16" O.C.WALL LEGENDCMU WALL - 8" (U.N.O.) BRG. HT. @ 8'-0'' AFFINTERIOR SIDE TO PAINTED SMOOTH FINISHEXTERIOR SIDE TO BE STUCCO COATED CMUSYMBOLREPRESENTSBRG. PARTITION WALL - 6" (U.N.O.)1/2" GYP. BD. ON EACH SIDE OF 2x4 WD. STUDS @ 16" O.C.CMU KNEEWALL - 8" (U.N.O.) BRG. HT. @ 3'-0'' AFFBOTH SIDES TO BE STUCCO COATED CMUCMU WALL - 8" (U.N.O.) BRG. HT. @ 11'-0'' AFF1/2" GYP. BD. OVER 1x2 P.T. FURRING STRIPS OVERSPRAY APPLIED FOAM INSULATION OVER 8" CMU WALL.EXTERIOR SIDE TO BE STUCCO COATED CMUCMU WALL - 8" (U.N.O.) BRG. HT. @ 8'-0'' AFF1/2" GYP. BD. OVER 1x2 P.T. FURRING STRIPS OVERSPRAY APPLIED FOAM INSULATION OVER 8" CMU WALL.EXTERIOR SIDE TO BE STUCCO COATED CMULIVINGGARAGELANAIENTRYTOTALLIVING C.F. +/- 17,81520454102331422830SQUARE FOOTAGETYPE DESIGNATIONF = FILLED WITH GROUT / U = UNFILLEDGRAVITY LOAD8F16-1B/1TNOMINAL WIDTHNOMINAL HEIGHTADDED REBAR AT TOP OFQUANTITY OF #5 FIELDCOMPOSITE U-LINTEL FORUPLIFT LOADTOP OF COMPOSITE#5 FIELD ADDED REBAR ATU - LINTEL MIN. (1) REQ'D1-1/2" CLEARFIELD PLACED C.M.U.GROUT8" NOMINAL WIDTH7-5/8" ACTUALBOTTOM REINFORCING#5 FIELD ADDED REBAR ATPROVIDED IN U-LINTEL(SEE REINFORCING SCHEDULE)For a 5’-10” overall length U-lintel Type 8F16-1B/1T:Safe superimposed gravity load = 4360 PLFSafe superimposed uplift load = 2080 PLFSafe superimposed lateral load = 339 PLFBOTTOM OF U-LINTEL CAVITYBOTTOM OF U-LINTEL CAVITY FORQUANTITY OF #5 FIELD ADDED REBAR AT16" NOMINAL HEIGHT15-5/8" ACTUAL CASTCRETE PRECAST LINTEL SCHEDULEBeamCompositeSafeGravityLoadAppliedGravityLoadSafeUpliftLoadAppliedUpliftLoad24'-4''8F16-1B-1T6113<10002707<50044'-6''8F16-1B-1T61132707<1000<5005'-6''8F16-1B-1T4360<10002080<50056'-2''8F16-1B-1T3480<10001868<50067'-4''8F16-1B-1T2661<1000<500162477'-6''8F16-1B-1T2661<10001624<50087'-8''8RF14-1B-1T1568<10001072<50098'-0''8F16-1B-1T1843<10001136<500109'-4''8F16-1B-1T<100018431136<5001110'-4''8F16-1B-1T1533<100091612r<5008F16-1B-1T10'-8''1366<1000800<5001312'-8''8F16-1B-1T1075<1000607<5001417'-4''8F16-1B-1T950<1000405<5001519-4''7508F16-1B-1T348<1000<5005'-10''4360<10002080<5008F16-1B-1T13'-8''8F16-1B-1T6113<10003060<50034'-6''8F16-1B-1T61132707<1000<5004'-8''8F16-1B-1T5365<10002276<500161718193'-0''8F16-1B-1T6113<10003524<500POST SCHEDULETHREE 2x4 STUDS NAILED TOGETHER WITH 16d NAILS EACH FACE AT 12"o.c. STARTING AT 6" FROM ENDS; ATTACH TO GIRDER/TRUSS AT TOP W/(2) SIMPSON "HTS20" & AT BOTTOM W/ (1) SIMPSON "HTT4" PERMANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS.NOTE: FOR 2x6 WALL USE 2x6 STUDSP-1 POSTTHREE 2x4 STUDS NAILED TOGETHER WITH 16d NAILS EACH FACE AT 12"o.c. STARTING AT 6" FROM ENDS; ATTACH TO GIRDER/TRUSS AT TOPW/ (1) SIMPSON "MGT" & AT BOTTOM W/ (2) SIMPSON "HTT4" PER MANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS.NOTE: PAD TRUSS AS REQUIRED @ TOP TO ALLOW FOR TRUSS CONNECTORP-2 POSTTWO 2x4 STUDS NAILED TOGETHER WITH 10d NAILS EACH FACE AT 12"o.c. STARTING AT 6" FROM ENDS; ATTACH TO GIRDER/TRUSS AT TOPW/ (2) SIMPSON "MTS20" & AT BOTTOM W/ (1) SIMPSON "HTT4" PERMANUFACTURER'S RECOMMENDATIONS FOR NAILS AND BOLTS.NOTE: FOR 2x6 WALL USE 2x6 STUDSP-3 POSTMARKSPECIFICATIONSNOTE: FOR 2x6 WALL USE 2x6 STUDS127'-8''8F16-1B-1T1843<10001136<500PRESTRESSEDPRESTRESSEDSIMPSON HTS20CONNECTED TOEACH TRUSSALONG FRAMED BEARING WALLSU.N.OSIMPSON HTS20 CONNECTED TO EACH TRUSS ALONG FRAMED BEARING WALLS U.N.O P1 POSTCHRISTOPHER D. BEERS, P.E.FLORIDA LICENSE NO. 64594W A T E R - A I R - L A N D5109 Grand Palmetto WayNorth Port, Florida 34291-8049941-628-0635fax 413-687-9013chrisbeers@byu.net8CRESTVIEW KW JSBA JONATHAN SANTANA & BRITTANY AUTRY S. BROCKSMITH RD FT PIERCE FL 34945 511 SW PORT SAINT LUCIE BLVD. PORT ST. LUCIE, FL 34953P1 05/22/20P2 06/09/20P3 07/03/20P4 07/07/20P5 09/22/20P6 12/04/204 SHLV WWHR&S R&S R&S 36'' GAS RANGE W/ HOODVENT (THROUGH ROOF)KNEEWALL W/BARTOP @ CABINET HTR&SR&SR&SR&S FG TUB/SHOWERVAULT TO 10'-0'' FLAT CLG10'-8'' FLATCLG AFFT&G CLGCRASHPOLE42'' KNEEWALLGLASS ABOVEDWREFmirror2X6 WALL R-11 INSULATION R-11 INSULATIONa/h inattic22'' X 54''ATTIC ACCESSFIELD LOCATE10'-0'' FLAT CLG8'-0'' FLAT CLG AFF8'-0'' FLAT CLG8'-0'' FLAT CLG8'-0'' FLAT CLG8'-0'' FLAT CLG8'-0'' FLAT CLGMASTER SUITELANAIBATH 2BEDROOM #2BEDROOM #3BEDROOM #4LIVING ROOMKITCHENDININGENTRYFOYERGARAGEMASTER BATH20 MIN FIRE RATEDSELF CLOSINGDRYVENTTHRUROOF16' X 7' OHDSH 352868 SC28684068 BF 2 SH 25 EGRESS SH 25 EGRESS 4068 BF 2 4068 BF 2 2868 2868 SH 25 EGRESS2668 28682068 BF 38'' ARCH38'' ARCH 2868 SH25 EGRESS 2668 4068 BF 2 30684'-6"2'-10"2'-0"16'-0"2'-0"3'-2"1'-4"3'-2"19'-4"15'-7"3'-2"4'-4"28'-4"23'-1"20'-0"8"8'-8 1/2"2'-5"10'-7 1/2"8"8"12'-5 1/2"8'-3 1/2" 8"20'-2"11'-4"10'-10"11'-8"8"18'-8"8"1'-6 1/2"18'-8"8"7'-6 1/2"3'-8"13'-0 1/2"8"2'-5"10'-7 1/2"8"7'-0"2'-5"10'-7 1/2"8"8"20'-2" 7'-4"4'-0"3'-10"7'-0"3'-2"2'-10 1/2"5'-7 1/2"8"9'-4"1'-4"20'-7"8"8'-4"17'-5 1/2"20'-9 1/2"3'-8"2'-0"3'-0"3'-4" 12'-5 1/2"SH 3530688'-0'' FLAT CLG AFF7'-4"1'-4"8'-8"1'-4"1'-4"6'-0"10'-0"51'-0"7'-4" 4'-4"8"8'-0'' FLAT CLG AFFT&G CLGSH 251'-4"12'-7"1'-4"12'-8"27'-11"51'-0"22'-0"7'-0"1'-4" 42'-8"8'-4" 58'-4"12'' COFFER CLG W/ CROWNRECESSSHOWER5' TUB6'' COFFER CLGW/ CROWN8"12'-2"4'-0"28688"4'-6"1'-4"10'-1"4'-6" 8" 21'-3 1/2"8"3'-0"4'-6"1'-10"8"2'-4"4'-6"2'-10"8"8"12'-2"5'-10 1/2"3'-10"8"5'-10"3'-0"3'-4"3'-11"9068 PKT SGD58'-4" 2"6"6'-8"PORCH1'-0"5'-4 1/2"2'-5"3'-6"5'-0'' OPEN 1'-6 1/2"11'-9"VAULT TO 10'-0''FLAT CLG2068 BFPANTRY2'-4"2'-6"6'-3 1/2"5'-0" WALL OVEN DOUBLE FARM SINK8"12'-5 1/2"5'-312"3'-5"8"9'-4"11'-8"4'-4"8'-0"3'-2"17'-6"3'-4"3'-0"55'-4"3'-0"10'-5"3'-2"3'-8"8"3'-0"7'-4"5'-712"812"2'-634"2868PKTJOB NO.SHEETwww.bluestreamdesignstudio.comCAD@bluestreamdesignstudio.comResidental CAD Drafting3D RenderingsGraphic Design ServicesDESCRIPTION12345678Port Charlotte, Fl(941) 275-9931DATECHECKED BY:DESIGN BY:DESIGNSTUDIOBLUESTREAMBSDSREVAlthough every effort is made toensure the accuracy of theseplans it is the responsibility ofthe builder to verify alldimensions, details andspecifications shown.Bluestream Design Studio willnot be held liable for any errorsor omissions on these plans.Design and layout or conceptsfor this design were provided toBluestream Design Studio bythe builder shown. Anysimilarities to other plans orblueprints is solely theresponsibility of the builder.Plans may not be reproduced orcopied without the expresswritten consent of the Buildershown.Builder:Project:SCALE:OFTMBLBB1/4" = 1'-0"CRESTVIEW KW JSBA PermitSet rev 120420.dwg12/11/20A2FLOOR PLAN3NOTES:R20 spray foam in whole housew/thermal barrier betweengarage and a/c spaceInsulation in all interior wallsthroughout home (R11 batts)