FL17443
i la { FL# New
Application Type 2014
Code Version Approved
Application Status
Comments
Archived
J A TAYLOR ROOFING
Product Manufacturer 302 Melton Drive
Address/Phone/Email FT PIERCE, FL 34982
(772)466-4040
kylew hite228@aol.com
Kyle Taylor
Authorized Signature kylewh1te22B@a0l.c0m
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Roofing
Category Metal Roofing
Subcategory
Evaluation Report from a Florida Registered Architect or a Licensed
compliance Method Florida Professional Engineer Received
?" Evaluation Report-Hardcopy
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report PE-49704
Florida License Keystone Certifications,Inc.
Quality Assurance Entity 04/11/2021
Quality Assurance Contract Expiration Date Hermes F. Norero, P.E.
Validated By Validation Checklist-Hardcopy Received
r mriwnend Inck�Bow en P.E.• d
F"744' an r Oi GerSi�l+�rss�, — _�•„—
Certificate of independence
Year
Referenced Standard and Year(of Standard) O 58�� 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted 03/02/2015
Date Validated 03/02/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015
Summary of Products
-_........
FL# Model,Number or Name Description
17443.1 5 V Crimp 26GA 1/2"rib height over 15/32" plywood
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17443 RO IT 5 V Crimp Fastening Detail.p2 j
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-129.25 Evaluation Reports
Other:-129.25 @ 6"o.c. -69.25 @16"o.c. margin of safety FL17443 RO AF FL 17443 3. A. Taylor Roofinc_5 V Crimp
2:1 with 24"max. coverage Install per manufacturers detail. Re orrt-ss.1df
Not for use in HVHZ. Created by Independent Third Party: Yes
contact Us::7601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.if you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional Mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts;
U® et�ed M
Credit Card
Safe
1
Locke Bowden, P.F.
9460 Alysbury Place
Montgomery,AL 36117 FL# 17443
,TA Taylor Rooting Inc
302 Melton Drive
Fort Pierce,FL 34982
i
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel, 24" net coverage,
26GA min. over min.15132" thick CDX plywood decks.
Compliance: Florida Building Cede(FBC)2014; Section.1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580"Tests for Uplift Resistance"
Description: Architectural metal roof panel,26 gauge metal panels; over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1.507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure: -129.25 psf @ 6"o.c. and-69.25psf@16"o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2"annular ring shank nails spaced 6" o.c. reroofing,with less than 19/32" plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment. Deck,attachment to be by
other design professional.
Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8
Thru-fastened over min.15/32" plywood
Fasteners: # -15 HWH corrosion resistant fasteners with sealing washers, metal to wood connections with
9 b
fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use: Not for use in HVHZ. Install per manufacturer's instructions and must be designed
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021
Evidence Submitted:
a. UL 580/TAS 125 Tests for Uplift Resistance
b. Reference-Test Report 0224-0501-06 Hurricane Test Laboratory ���Rtlrtl>rr��
C. "Pest equivalency standard—the UL 580-94 test standard is equixnto
�d. Quality Assurance Procedures and Documentation "CiC��,a
o r
o s
r
^- 0 No. 49/04 e �-
sTn Cra`�z�,.z�
p
r
This report does not guurantee or warranty any product validated or installed.Manuf cturer's warranty applies.
5 V Crimp
Fastener-#9-15 corrosion resistant w/sealing washers
24°coverage
a
'. C.nW xx 4z
Y
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main Field fastening12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel