HomeMy WebLinkAboutProject Information (2) A
�117
MAR 15 2017
PERfAITTING
St. Lucie COUnty, FL
""' PY
.'f
Sheet 9
i•
i laundry th 74 cf
! office 5"
6 6 bedrm 2
8X8
8x8
14 x 1 151 cfm
8x8 7" •14x8
175 cfm 6
Air Handier in Closet over water
heater Louvered door. By-pass
( kitchen/nook 8 x 8 livin rm 1i3 cfm
grills over bedroom doors_
,.mstr bedrm mstr bath
8x8 8x8
91 cfm 135 cfm
r
THF_' 'E: i' D !;�_I� Pr'0 0 014t0,R: ST.LUCIE COUNTY
BUILDING DIVISION
ARE CSU:BVIECT T G ANY W'�I a����If�l'�� REVIEWED
`r�U-MU 10,'1 FREED INSPEC,PORS RIXT FOR COMPLI
WINter: ps��+ t';'q y ME rr REVIEWED BY
z[;N..;� 3':ECE31-11 P,rty IN 0F, 111 !01 DATE
C0,7jP..,VVIT!I AL A`'fUC"�,� C PLANS A PE IIT
J:��t 3eti I i 9 "� 4;r: r i,�;zj' `; . MUST BE KEPT O 'JOB OR
NO INSPECTION WILL BE MADE
Job#: Scale: 1 : 10;
Performed for: Page 1
Trevor Horvath Right-SuiteO Universal 2017
3521 Sunrise Blvd. 17.0.17 RSU06570
Fort Pierce,FI 2017-Mar-14 15:09:03 /
...Sunrise Blvd Trevor Horvath.rup
Job:
wrightsoft Project Summary Date: Feb 01,2017
Entire House By:
-Prok
For. Trevor Horvath TH E;r,�- C a..s Al'N D- A ji�1. P R,C;P 0 5-1,0 VVQ,R i,,,'
3521 Sunrise Blvd., Fort Pierce, FI A R'I:- CHUB i 17-CT'IF 0 A NI Y 0 0 IRM E C-17!0,@13,
Ez:QUI r 11-E�? S Y r-I CE.L D I i,I S P E C T 0 R S T I-I A T
s: M
7 AY
Note E; NKL�
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17480 Btuh Structure 19058 Btuh
Ducts 4067 Btuh Ducts 5382 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21548 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 23218 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Stricture 1901 Btuh
Ducts 1699 Btuh
Central vent(0 cfm) 0 Btuh
Heatin In 71 Cool' (gone)
Area(ft2) 11 1172 Equipment latent load 3601 Btuh
Volume (ft3) 9376 9376
Air changes/hour 0.45 0.23 Equipment total load 26819 Btuh
Equiv.AVF (cfm) 70 36 Req. total
capacity at 0.80 S HR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Goodman Mfg.Trade Trade GOODMAN; ANITROL;AMANA DIST[...
Model Cond GSX1 40311 K
AHRI ref coil AWUF370816B
AHRI ref 7516446
Efficiency 100 EFF Efficiency 12.2 EER, 14 SEER
Heating input 7.1 kW Sensible cooling 22400 Btuh
Heating output 24331 Btuh Latent cooling 5600 Btuh
Temperature rise 50 OF Total cooling 28000 Btuh
Actual air flow 443 cfm Actual air flow 933 cfm
Air flow factor 0.021 cfm/Btuh Air flow factor 0.038 cfm/Btuh
Static pressure 0 in H2O Static pressure 0.10 in H2O
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Mar-14 15:08:50
A+ wriightsofV Fugirit-suftee Universal 2017 17.0.17 RSU06570 Pagel
ACCK ...AManual J13521 Sunrise Blvd Trevor Horvat h.rup Calc=MJ8 Front Doorfaces: E
. �
wrightsoft° Righf-J®Worksheet Job:
Feb o�Date. ,2017
Entire House By:
1 Room name Entire House laundry
2 Exposed wall 146.0 ft 17.0 ft
3 Room height 8.0 ft 8.0 ft heat/cool
4 Room dimensions 9.0 x 8.0 ft
5 Room area 1172.0 ft' 72.0 ft'
Ty Construction U-value Or HTM Area (f?) Load Area (ft� Load
number (Btuh/ft'°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WI 12A-0sw 0.240 n 6.72 6.96 224 206 1384 1434 0 0 . 0 0
L-G 1A-.1om 1.270 n 35.66 34.77 -18 0 640 626 0 0 0 0
V�J 12A-0sw 0.240 a 6.72 6.96 360 315 2117 2192 0 0 0 0
�L-_Gp 1A-c1om 1.270 a 35.56 91.12 24 0 853 2187 0 0 0 0
11 11 PO 0.290 a 8.12 8.41 21 21 171 177 0 0 0 0
yJ 12A-0sw 0.240 s 6.72 6.96 224 194 1304 1350 64 52 349 362
II�G IA-c1om 1.270 s 35.56 34.77 12 24 427 417 12 12 427 417
7Aciom 1.270 s 35.56 34.77 18 36 640 626 0 0 0 0
12A4Osw 0.240 w 6.72 6.96 360 308 2071 2145 72 52 351 363
1A-clom 1.270 w 35.56 91.12 32 0 1138 2916 0 0 0 0
II PO 0.290 w 8.12 8.41 20 20 161 167 20 20 161 167
C 1613--30ad UK - 0.90 1.68 1172 1172 1050 1969 72 72 65 121
F 19A-Ocvcp 0.295 - 3.10 1.66 1036 1036 3215 1722 72 72 223 120
F 19A-19cvcp 0.049 - 1.08 0.58 136 136 146 78 0 0 0 0
E-
61 c)AED wcursion 0 1 -108
Envelope loss/gain 15316 18006 1576 1442
12 a) Infiltration 2164 592 252 69
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 17480 19058 1828 1511
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17480 19058 1828 1511
15 Duct loads 23% 28% 4067 5382 23% 28% 425 427
Total room load 21548 24440 2253 1937
Air required(cfm) 443 933 46 74
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
vvri hts®Ft' 2017-Mar-1415:08:50
9 RightSuiteO Universal 2017 17.0,17 RSU06570 Page 1
ACCk ...rlManual A3521 Sunrise Blvd TrevorHoneth.rup Cale=MJ8 Front Doorfaces: E
. R
wrightsoft° Righ�O Worksheet • Job:
Entire House Date: Feb 01,2017
By:
1 Room name kitchen/nook office
2 Exposed wall 29.0 ft 12.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 9.0 x 20.0 ft 12.0 x 10.0 ft
5 Room area 180.0 ft2 120.0 ft2
Ty Construction U-value Or HTM Area OF) Load Area (ft2) Load
number (Btuh/f L'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12A-0sw 0.240 n 6.72 6.96 0 0 0 0 0 0 0 0
1Ac1om 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0
12A-0sw 0.240 a 6.72 6.96 72 60 403 418 0 0 0 0
-G 1Aclom 1.270 a 35.56 91.12 12 0 427 1093 0 0 0 0
11 �D 11 PO 0.290 a 8.12 8.41 0 0 0 0 0 0 0 0
12A-0sw 0.240 s 6.72 6.96 160 142 954 988 0 0 0 0
IA-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0.
1A-clom 1270 s 35.56 34.77 18 18 640 625 0 0 0 0
Wj 12A-0sw 0.240 w 6.72 6.96 0 0 0 0 96 84 564 5B5
I-G 1Aclom 1270 w 35.56 91.12 0 0 0 0 12 0 427 1093
�-D II PO 0.290 w 8.12 8A1 0 0 0 0 0 0 0 0
C 16B 30ad 0,032 - 0.90 1.68 180 180 161 302 120 120 108 202
F 19A-Ocvcp 0.295 - 3.10 - 1.66 180 180 559 299 120 120 372 199
F, 19A-19cvcp 0.049 - 1,08 CIM 0 0 0 0 0 0 0 0
6 c)AEDex;ursion -257 323
Envelope loss/gain 3144 3470 1471 2402
12 a) Infiltration 430 118 178 49
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 35741 3588 16491 2450
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3574 3588 1649 2450
15 Duct loads 23% 28% 832 1013 23% 28% 384 692
Total room load 7 14405 4601 2033 3142
Air required(cfm) 91 176. 42 120
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2017-Mar-1415:08:50
Mri 1t50ft' RightSuite®Universal 2017 17.0.17 RSU06570
Page 2
ACC.A ...rlManual A3521 Sunrise Blvd Trevor Honath.rup Calc=MJ8 Front Door faces: E
t
. •
+ -wrightsoft° RighAO Worksheet Job:Entire House Bate: Feb 01,2017
By:
1 Room name bath bednn 2
2 Exposed wall 7.0 ft 20.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat1cool
4 Room dimensions 7.0 x 8.0 ft 9.0 x 12.0 ft
5 Room area 56.0 ft2 108.0 ft'
Ty Construction U-value Or HTM Area (ftz) Load Area (ft� Load
number (Btuh/ftz-*F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 V 12A-Osw. 0.240 n 6.72 6.96 0 0 0 0 88 76 511 529
L-( IA-clom 1.270 n 35.56• 34.77 0 0 0 0 12 0 427 417
12A-0sw 0.240 a 6.72 6.96 0 0 0 0 0 0 0 0
11 i-G IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0
11 PO 0.290 a 8.12 8.41 0 0 0 0 0 0 0 0
V6212A-0sw 0.240 s 6.72 6.96 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
IA-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
UrJ 12A-0sw 0.240 w 6.72 6.98 56 48 323 334 72 60 403 418
IE---Gp IA-clom 1.00 w 35.56 91.12 8 0 284 729 12 0 4r 1093
11 PO 0.290 w 8.12 8.41 _ 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.90 1.68 56 56 50 94 108 108 97 181
F 19A-0cvcp 0.295 - 3.10 1.65 56 56 174 93 108 108 335 180
F 19A-19ovcp 0.049 - 1.08 ' 0.58 0 0 0 0 0 0 0 0
T P)y
61 c)AED mcursion 224 1 181
Envelope loss/gain 831 1475 2199 2999
12 a) Infiltration 104 28 296 81
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 935 1503 2496 3080
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 935 1503 2496 3080
15 Duct loads 23% 28% 217 424 23% 28% 581 870
Total room load 1152 19271 3076 3950
Air required(cfm) 24 74 63 151
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
W t'1 67tSOft' 2017-Mar-14 15:08:50
9 RightSuiteO Universal 2017 17.0.17 RSU06570 Page 3
ACCrF. ...r\Manual J\3521 Sunrise Blvd Trevor Horath.rup Calc=MJ8 Front Doorfaces: E
. • Job:
wrightsoft° Righ @ Worksheet Date: Feb 01,2017
Entire House By:
1 Room name mstr bedrm mstr bath
2 Exposed wall 12.0 ft 33.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 12.0 x 16.0 ft 8.0 x 17.0 ft
5 Room area 192.0 ft' 136.0 ftz
Ty Construction U-value Or HTM Area M2) Load Area (ft') Load
number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 w 12A-0sw 0240 6 6.72 6.96 0 0 0 0 136 130 874 905
'--G 1A-c1om 1.270 n 35.56 34.77 0 0 0 0 6 O 213 209
11 VLZ12A-Cisw 0.240 a 6.72 6.96 96 84 564 585 64 43 289 299
IA-c1om 1270 a 35.56 91.12 12 0 427 1093 0 0 0 0
11130 0.290 a 8.12 8.41 0 0 0 0 21 21 171 177
ViV 12A-0sw 0.240 s 6.72 6.96 0 0 0 0 0 0 0 0
I�_-�G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
UtJ 12A-0sw 0.240 w 6.72 6.96 0 0 0 0 64 64 430 445
EL-GD 1A-c1om 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0
11 PO 0,290 w8.12 8.41 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.90 1.68 192 . 192 172 323 136 136 122 _ 22B
F 19A-0cvcp 0.295 - 3.10 1.66 192 192 596 319 0 0 0 0
F 19A-19cvcp 0.049 - 1.08 0.58 0 0 0 0 136 136 146 78
6 c)PEDecursion -65 -165
Envelope loss/gain 1759 2254 2245 2176
12 a) Infiltration 178 49 489 134
b) Room ventilation 0 0 0 0
13 1ntemal gains: Occupants @ 230 2 460 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1937 2763 2734 2310
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1937 2763 2734 2310
15 Duct loads 23% 28% 451 780 23% 28%1 636 652
Total room load I 1 88 3543 3370 2963
Air required(cfm) 49 135 69 113
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2017-Mar-1415:08:50
wri htsoft
Right-Suite®Universal 2017 17.0.17 RSUD6570 Page 4
ACCA ...r\Manual A3521 Sunrise Blvd TrevorHomth.rup Cslc=MJ8 Front Doorfaces: E
�+wrightsott° Right®Worksheet
Job:
Entire House Date: Feb 01,2017
1 Room name living rm
2 Exposed wall 16.0 ft
3 Room height 8.0 ft heat/cool
4 Room dimensions 1.0 x 308.0 ft
5 Room area 308.0 ft2
Ty Construction U-value Or HTM Area (ftz) Load Area Load
number (BtuWftl--°F) (Btuh/ftiz) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WII 12A-0sw 0.240 n 6.72 6.96 0 0 0 0
G 1Ac1om 1.270 n 35.56 34.77 0 0 0 0
12A-0sw 0.240 a 6.72 6.96 128 128 860 891
1Aclom 1.270 a 35.56 91.12 0 0 0 0
11 11 PO 0.290 a 8.12 8.41 0 0 0 0
V11 12A-0sw 0.240 s 6.72 6.96 0 0 0 0
!L-�G, 1A-ciom 1.270 s 35.56 34.77 0 0 0 0
1Aciom 1.270 s 35.56 34.77 0 0 0 0
12A-Osw 0240 w 6.72 6.96 0 0 0 0 jo 1A-clom 1.270 w 35.56 91.12 0 0 0 0
11P0 0.290 w 8.12 8.41 0 0 0 0
C 168-30ad 0.032 - 0.90, 1.68 308 308 276 517
F 19A-0cvcp 0.295 - 3.10 1.66 308 308 956 512
F 19A-19cvcp 0.049 - 1.08 0.58 0 0 0 0
r
6 c)AED excursion -132
Envelope loss/gain 2092 1788
12 a) Infiltration 237 65
b) Room ventilation 0 0
13 Intemal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 2329 1853
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 2329 1853
15 Duct loads 23% 28% 542 523
Total room load 2871-T
2376
Air required(cfm) 59 91
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2017-Mar-14 1
wrightSOft" RightSuite®Universal 2017 17.0.17 RSU06570 Page 5
ACCA ...r\Manual A3521 Sunrise Blvd TrevorHonath.rup Calo=MJ8 Front Doorfaces: E
Flod Building Code, Energy Con anon
Residential Building Thermal Envelope Approach
FORM R402-2014 R Value Computation Method Climate Zone 2
Scope:Compliance with Section R402.1.1 of the Florida Building Code, Energy Conservation,shall be demonstrated by the use of Form R402 for
single and multiple-family residences of three stories or less in height,additions to existing residential buildings,renovations,and building
systems in existing buildings,as applicable.To comply,a building must meet or exceed all of the energy efficiency requirements on Table R402A
and all applicable mandatory requirements summarized in Table R402B of this form.If a building does not comply with this method, or by
the UA Alternative method,it may still comply under Section R405 of the Florida Building Code,Energy Conservation.
PROJECT NAME: Trevor Horvath BUILDER:
AND ADDRESS: 3521 Sunrise Slvd PERMITTING OFFICE: St Lucie Count
Fnrt Pierce-El JURISDICTION NUMBER:
OWNER: I revor Horvath PERMIT NUMBER:
General Instructions:
1.Fill in all the applicable spaces of the"To Be Installed"column on Table R402A with the information requested.All"To Be Installed"values
must be equal to or more efficient than the required levels.
Z Complete page 1 based on the'To Be Installed"column information.
3.Read the requirements of Table R402B and check each box to indicate your intent to comply with all applicable items.
4.Read,sign and date the"Prepared By"certification statement at the bottom of page 1.The owner or owner's agent must also sign and date the form.
1. New construction, addition, or existing building 1. _ Existing Check
2. Single-family detached or multiple-family attached 2, single family
3. If multiple-family, number of units covered by this submission 3.
4. Is this a worst case?(yes/no) 4.
5. Conditioned floor area(sq.ft.) 5. 1144
6. Windows type and area:
a) U-factor: 6a.
b) Solar Heat Gain Coefficient(SHGC): 6b.
c) Area: 6c.
7. Skylights,type and area:
a) U-factor. 7a.
b) Solar Heat Gain Coefficient(SHGC): 7b.
c) Skylight area: 7c,
B. Floor type, area or perimeter, and insulation:
a) Slab-on-grade(R-value) ga. P F=
b) Wood, raised (R-value) 8b. j f! f _CE
c) Wood, common(R-value) 8c ! j !;!, l r_ n.
,
d) Concrete, raised (R-value) 8d_
e) Concrete, common (R-value) 8e.
9. Wall type,area and insulation:
a) Exterior. 1.Wood frame (Insulation R-value) gal.
2. Masonry(insulation R-value) 9a2.
b) Adjacent: 1. Wood frame(Insulation R-value) 9b1.
2. Masonry(Insulation R-value) 9b2.
10. Ceiling type, area and insulation
a) Attic(Insulation R-value) 10a.
b) Single assembly(Insulation R-value) 10b.
11. Air distribution system:
a) Duct insulation 1la. R-6
b) AHU location 11b. Interior
c) Total duct Leakage,Test report attached 11c. NONE
12. Cooling system: a)type: 12a. Straight Cool _
b)efficiency 12b. 14 �L
13. Heating system: a)type: 13a. Electric _
b) efficiency 13b. 100
14. HVAC sizing calculation: attached 14. yes
15. Water heating system: a)type 15a.
b) efficiency 15b.
1 hereby certify that the plans and specifications covered by this Review of plans and specifications covered by this form indicate
form are in compliance with the Ftoridq,Bu#ding"Code, r compliance with the Florida Building Code,Energy Conservation
Energy Conservation./ j r Before construction is complete,this building will be inspected for
PREPARED Date .%.'.%f compliance in accordance with Section 553.908,F.S.
I hereby certify that this bull404A
Impliance with the"
Florida Building Code ation_ _1VfOWNER/AGENT: WWWWWW��I��I'''"'������ Date CODE OFFICIAL: Date
2/2/2017 4:56:56 PM EnergyGauge®/USRCSB v5.1-Section R405.4.1 Compliant Software Page 1 of 3
'FORM R402 2014TABLE 402A
•
BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES
Climate Zone 1 Climate Zone 2 Fens.U-Factor(Ave)=0.000 PASS
Windows U-Factor=0.652 U-Factor=0.402 U-Factor-
SHGC= 0.25 SHGC= 0.25 SHGC=
Skylights U-Factor=0.75 U-Factor=0.65 U-Factor-
SHGC= 0.30 SHGC= 0.30 SHGC=
Doors:Exterior door U-Factor= 0.653 U-Factor=0.403
Floors: Over unconditioned spaces" R-13 R-13 R-Value=
Common R-11 R-11
Walls:Ext.and Adj.
Frame R-13 R-13 R-Value=
Mass(Insulation on wall interior): R4 R-6 R Value=
Mass(Insulation on wall exterior): R-3 R-4 R-Value=
Ceilings:Exposed R-30 R-38 R-Value= Test report
Common R-11 R-11
Air infiltration: Blower door testis requl ed on the building Total leakage(ACH50)_
envelope to verify leakages 7 ACH50;test Test report attached?
report provided to code official. ❑Yes D No
Air distribution systems:
Air handling unit Not allowed in attic Closet-interior
Sealed
Duct R-Value R-value a R-8(supply in unconditioned attics)
or ZR-6(all other unconditioned duct locations). R-6
Air Leakages:
Duct test Air handler installed:Total leakages 4 cfm/100 s.f.
Air handler Not installed:Total leakage s 3 cfm/100 s f. Test report required? YES
Ducts in conditioned space Test not required if all ducts and AHU are in Location:Unconditioned
conditioned space.
Air conditioning systems: Minimum federal standard required by NAECAs
Central system s 65,000 Stu/h SEER=14.0 SEER= 14
EER[from Table C403.2.3(3)]
PTAC
Other:
Heating systems: Minimum federal standard required by NAECAS Electric
Heating Pumps 65,000 Btu/h HSPF=8.2 HSPF=
Gas Furnace,non-weatherized AFUE 780A(AFUE 80%after Nov.2015) AFUE=
Oil Furnace,non-weather zed AFUE 83% AFUE=
Other. L4:
Water heating system(storage type): Minimum federal standard required by NAECA6 ar Y
Electric:7 40 gallons:EF=0.95,50 gallons:EF=0.95FGas fired:B 40 gallons:EF=0.62,50 gallons:EF=0.60 �)
, *-'�
L I
Other(describe):
R-Value Calculation Method(circle one) - PASS FAIL
NR=No requirement
(1)Each component present in the As Proposed home must meet or exceed each of the applicable criteria in order to comply with
this code using this method.
(2)For impact rated fenestration complying with Section R301.2-1.2 of the Florida building Code,Residential or Section 1609.1.2 of the
Florida Building Code, Building the minimum U-factor shall be 0.75 in Climate Zone 1 and 0.65 in Climate Zone 2.An area-weighted
average of U-factor and SHGC shall be accepted to meet the requirements,or up to 15 square feet of glazed fenestration area are
exempted from the 1-1-factor and SHGC requirement based on Section R402-3.1,R402.3.2 and R403.3.3.
(3)One side-hinged opaque door assembly up to 24 square feet is exempted from this U-factor requirement.
(4)R-values are for insulation material only as applied in accordance with manutacturene installation instructions.For mass wags the"interior of wall'
requirement must be met except if at least 50 percent of the insulation required for the"exterior of wall"is installed exterior of,or integral to,the wall.
(5)Ducts&AHU installed"substantially leak free"per Section'R403.2Z Test required by an energy rater certified in accordance with Section
553.99,Florida Statues,or as authorized by Florida Statutes.The total leakage test is not required for ducts and air handlers located entirely
within the thermal envelope.
(6)Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are
subject to NAECA rules and regulations.For other types of equipment,see Tables C403.Z3(1-11)of the Commercial Provisions of the
Florida Building Code,Energy conservation.
M For electric storage volumes 5 55,min.EF=0.960-(0.0003`volume).For electric storage volumes>55,min.EF=2.057-(0.00113'volume).
(8)For natural gas storage volumes 6 55,min.EF=0.675-(0.0015'volume).For natural gas storage volumes>55,min.EF=0.8012-(0.00078'volume).
(9)For electric tankless,min.EF=0.93.For natural gas tankless,min.EF=0.82
202017 4:56:56 PM EnergyGauge®/USRCSB v5.1-Section R405.4.1 Compliant Software Page 2 of 3.
• FORM R402-2014
TABLE 402B MANDATORY REQUIREMENTS
Component Section Summary of Requirement(s) Check
Air leakage R402.4 To be caulked,gasketed,weatherstripped or otherwise sealed per Table R402.4.1.1.
Recessed lighting IC-rated as having s 2.0 cfm tested to ASTM E 283.
Windows and doors:0.3 cfm/sq.ft(swinging doors:0.5 cfm/sf)when tested to NFRC 400 or
AAMAtWDMAlDSA 101 A.S.2/A440.
Fireplaces:Tight-fitting flue dampers&outdoor combustion air.
Programmable thermostat R403.1.2 Where forced-air furnace is primary system,programmable thermostat is required.
Air distribution system R403.2.2 Ducts shall be tested to Section 803 of the RESNET standards by an energy rater certified in
R403.2.4 accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes.
Air handling units are not allowed in attics.
Water heaters R403.4 Comply with efficiencies in Table C404.2.Hot water pipes insulated to_>R-3 to kitchen outlets,
other cases.Circulating systems to have an automatic or accessible manual OFF switch.
Heat trap required for vertical pipe risers.
Cooling/heating equipment R403.6 Sizing calculation performed&attached. Special occasion cooling or heating capacity
requires seperate system or variable capacity system.
Swimming pools&spas R403.9 Spas and heated pools must have vapor-retardent covers or a liquid cover or other means
proven to reduce heat loss except if 70%of heat from site-recovered energy.Of itimer switch
required.Gas heaters minimum thermal efficiency is 82%.
Heat pump pool heaters minimum COP is 4.0
Lighting equipment R404.1 At least 75%of permanently installed lighting fixtures shalt be high-efficacy lamps.
I Ua P
ba
e7
S 'tls�d
2/2/2017 4:56:56 PM EnergyGauge®/USRCSB v5.1-Section R405.4.1 Compliant Software Page 3 of 3