HomeMy WebLinkAboutProduct Approval (2) lit
3 t
®R
£.A.. A...:.,.,.,F,....,,m.................... a.,., .,, .. .,_... >,.........m ..w.,,...... ...«.».....,..max.. & ..t'&.�i;'c,.,,..,.fn,,.,.r..�—...a � ,...c l.s..k....a^.. ".dWka'u+`.0
BCIS Home Log In E User Registration S Hot Topics t. Submit Surcharge Slats&Facts Publications ? FBC Staff CIS Site Map Links Search I
Ist�,�'ProductApproval
USER:Public User
RE C
" P !r,-v.
Product Approval Menu>Product or Application Search>Application Lis[>Applimtion Detail
FL FL15220-R1 a +sat
FEB 2 c; Kl?
Application Type Revision PERM11 Tins:.;
Code Version 2014 5t. LUCID :,OttDi? �L
Application Status Approved
a
vii
z-4F � r
Comments i'i
I (7 j (; 'S,
Archived
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES,CA 90045
(440)969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440) 969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440) 969-9773 Ext 16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F. Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King,P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL15220 R1 COI CERTIFICATE of IN DEPENDENCE.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1929 1996
ASTM D2843 1999
ASTM D635 1998
ASTM D638 2003
ASTM E1300 2004
ASTM E84 2005
ASTM G26 1995
TAS 202 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL15220 R1 Eauiv Eauivalencv Of Standards.odf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/24/2015
Date Validated 04/26/2015
Date Pending FBC Approval 04/28/2015
Date Approved 06/23/2015
Summary of Products
FL# Model, Number or Name Description
15220.1 a.Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Single Door-
Grain/Rustic/Mahogany Series N Inswing/Outs wing (X-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.1.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15220.1 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.1.pdf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.2 b. Smooth/Wood 68"Non-Impact"Glazed Fiberglass Single Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelite-Inswing/Outswing(OX or XO-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.2.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15220.2 for Design Pressure Ratings,any FL15220 RI AE Eval 15220.2.1)df
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.3 c.Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Single Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing(OXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 TI Inst 15220.3.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15220.3 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.3.pdf
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15220.4 d.Smooth/Wood 68"Non-Impact"Glazed Fiberglass Double Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing (XX-Configuration)
Fiberglass Door
Limits of Use ::`r` Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.4.13df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST'15220.4 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.4.1)df
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.5 e.Smooth/Wood 6'8"Non-Impact"Glazed Fiberglass Double Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing(OXXO-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 -II Inst 15220.5.pdf
Approved for use outside HVHZ: Yes Verified-By: Lyndon F.Schmidt,P.E.43409
i
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.5 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.5.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.E f. Smooth/Wood 6'8"Non Impact"Opaque Fiberglass Single Door-
Grain/Rustic/Mahogany Series N Inswing/Outswing (X Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.6.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.6 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.6.1)df
additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15220.7 g. Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Single Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelite-Inswing/Outswing(OX or XO-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.7.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.7 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.7.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.8 h.Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Single Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelites-Inswing/Outswing(OXO-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.8.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.8 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.8.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.9 i. Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Double Door-
Grain/Rustic/Mahogany Series N Inswing/Outs wing (XX-Configuration)
Fiberglass Door
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.9.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.9 for Design Pressure Ratings,any FL15220 R1 AE Eval 15220.9.odf
additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.10 j. Smooth/Wood 6'8"Non-Impact"Opaque Fiberglass Double Door with"Non-
Grain/Rustic/Mahogany Series N Impact"Sidelites-_Inswing/Outswing (OXXO-
Fiberglass Door Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.10.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15220.10 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.10.pdf
any additional use limitations,,installation instructions and Created by Independent Third Party: Yes
product particulars. € `a
15220.11 k.Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Single Door-
Fiberglass Door Inswing/Outs wing (X-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.11.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 152.20.11 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.11.1)df
any additional use limitations, installation instructions and Created by Independent Third Party.: Yes
product particulars.
15220.12 L Smooth/Wood Grain Series N
Fiberglass Door
8'0"Non-Impact"Glazed Fiberglass Single Door-with"Non-
Impact"Sidelite-Inswing/Outswing (OX or XO-
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.12.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.12 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.12.pdf
any additional use limitations,installation instructions and Created by'Independent Third Party: Yes
product particulars.
15220.13 m.Smooth/Wood Grain Series N 8'0"Non Impact"Glazed Fiberglass Single Door with"Non
Fiberglass Door Impact"Sidelites-Inswing/Outswing(OXO-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.13.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.13 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.13.odf
any additional use limitations,installation instructions and Created by Independent Third Party: Yes
product particulars.
15220.14 n.Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Double Door-
Fiberglass Door Inswing/Outs wing (XX-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.14.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15220.14 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.14.1)df
any additional use limitations,installation instructions and Created by Independent Third Party:Yes
product particulars.
15220.15 0. Smooth/Wood Grain Series N 8'0"Non-Impact"Glazed Fiberglass Double Door with"Non-
Fiberglass Door Impact"Sidelites Inswing/Outswing(OXXO
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15220 R1 II Inst 15220.15.pdf
Approved for use outside HVHZ:.Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15220.15 for Design Pressure Ratings, FL15220 R1 AE Eval 15220.15.1)df
any additional use limitations, installation instructions and Created by Independent Third Party: Yes
product particulars.
Back Next
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
sw
n Plastpro .\\� - ^
m FRAME -,0
WIDTH o J_d
f-----37.5 ALL_ U?� a z
5200 W. CENTURY BLVD. �•` --
LOS ANGELES, CA 90045
`N z
��'' •�pj` F `Nn
i Smooth Wood Grain White Wood Grain ''��rr `111� ° n••..z
U N
Q
Rustic /Mahogany v a a N0
Series N Fiberglass Door �, a m a Q.e
INSWING/OUTSWING " z ? LL°Z 3 E 0
"NON-IMPACT" i o o �Ta
GENERAL NOTES w O (D o
x = E) v,z
1. This product has been evaluated and is incompliance with the 5th Edition(2014)Florida Building Code w o o
(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). LL o z
w
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base < a a m
ski
material shall be beyond wall dressing or stucco. > ��h w
O Dam¢ ¢cc
3. When used in the"HVHZ"this product is required to be protected with an impact resistant covering that
complies with Section 1626 of the FBC. oUj
a a
4. When used in areas outside of the"HVHZ"requiring wind bome debris protection this product is required
to be protected with an impact resistant covering that complies with Section 1609.1.2 of the FBC. Co
a
5. For 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x buck
d masonry construction.
g
.6. Site conditions that deviate from the details of this drawing require further engineering analysis by a
licensed engineer or registered architect. fn o
?'i w rn
7. Outswing configurations meet water infiltration requirements for"HVHZ". r"
0
- 8. Inswing configurations do not meet the water infiltration requirements for the"HVHZ".Inswing units shall
be installed only in non-habitable areas or at habitable locations protected by an overhang or canopy o
a such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. - '
TABLE OF CONTENTS MAX:. DESIGN PRESSURE(PSI) f N Uj
SWING FRAME.: - a
a SHEET N DESCRIPTION
6 DIMENSION. POSITIVE .NEGATIVE
s 1 Typical elevation,design pressures,&general notes
2 Door panel details 37.50" yam^ '�z
3 Horizonfalcrosssections INSWING x +50.0 -50.0 L>. -=� DATE:02120112 Z
2 81.63" SCALE: N.T.S.
4 Vertical cross sections
S Buck and frame anchoring-2X buck masonry construction 37.50" DWG.BY: JK m
0 6 Frame anchoring-IXbuckmasonryconstruction OUTSWING x +50.0 -50.0 CHK.BY: LFS 3
7 Bill of materials&components 80.50" DRAWING NO.: D
FL-15220.6
o
SHEET 1 Of 7 N
f�
R; ients\Flastpra,Inc PERMANENT\Florida Product A royals\FL-15220\C-Drawin s\Current\FL-15220.6-10.dw,1-3
3�
O �O
m
0
10
Op= 14
0=0
A
o�O V &'y 0410
o-O n coo _
=r..• G � A W o
F3
N 0 ~
T � �
y0 A A v A N
W W W N
X Z
m
W W E2 A_
O O
Z7 ."i7
op
N CD
�O
X y Oe
U r V
Q'(7
c�p
�0 � N
0
m
X Z
W N M T
�;a Z n
M A O y
i
0 L j N 09
OrO Z N 'C' ° e r-•
m 0 —r 00 p °
O.? O J n N c v
o
Av
0
z n
m
O
P °
v v
v �
SCHIy��
/ No.43409 '
fe $ x E y PRODUCT: Documents Prepared By: '
Lyndon F. SchmidtPLASTPRO INC. �js•'•�OR1DR •G�`�
IC n ? s K Z N FIBERGLASS DOOR P.E. No. 43409 /S..�ALI.
N r- -I o PART OR ASSEMBLY: /«i BUILDING CONSULTANTS, INC.
o �7 Z (n\ 1 04/22/15 UPDATE H ED. (2014) FBC JK HORIZONTAL CROSS SECTIONS eJ�
P.O. Box 230, Valrico, FL 33595
m N NO DATE BY Phone No.: 813.659.9197
ISION$ FBPE CA. No. 9813 r
0 2012 R.w.BUILDING C015LII—NTS INC.
,�._k+:nslFie;nro,:nc�Efi�1kNlNT\Flyida N viucl,App1C KyL-1S220\C-Drawings\Current\FL-15220.6-ID.dwg,1-4 '
i
I
f
1 i r4°MIN.' C7
I � EMS.(TYP.).
M
( m n 0 v
72 R
p A J A C av I
Lell °
C
i r)n
(7 v' Es rb-
mon
0
°
Im
M 70
O
Z ,v o Q Z °
v °
t� C
ov
Z
m
1-I M MIN.
m EMS.)TYP.)
T
T
A N
v C A O n
o O
C
° C A
Cr n.
A a n
T
rn n
fp n ^ O A A V
0 T
O Q
O y °
� H e
rn
T °
f4
Z ° CD
° 1-114 MIN.
Z EMS.PP.)
H° to C3 M
1-11N MIN. A
EMS.)TYP.)
No.43409
$ PRODUCT: Documents Prepared 13y'i `
Fn Lyndon F. Schmidt �j�•••
K m\ FIBPLASrPRO INC.
ERGLASS DOOR P/'/E� No. 43409 S�O►VA1�fill,;
PART OR ASSEMBLY: /�p��BUILDING CONSULTANTS, INC.
hp V7\ 1 04 22 15 UPDATE TO 5TH ED. (2014) FSC JK rl 1iVU P.O. Box 230, Valdco, FL 33595
v rn ro NO DATE 6Y VERTICAL CROSS SECTIONS Phone No.: 813.659.9197
REVISIONS FBPE CA No. 9813
C zo12 R.W.BUILDING DaNSU-TS INC. ' '
50 41 INTERIOR 46 42 i o = Lo
d 01
o m
o o m zm
43 43 lj o N o
o Z o=C)
N Em m m
EXTERIOR ut a ''An 'm a a T
� L ,
2 HORIZONTAL CROSS SECTION o J a
2
` 35.75"MAX.
DOOR
PANEL WIDTH 1.22" 81" o
p 41 zo 0
ncL
(5 w a
3 0FE-11 �. U ar o
o
�1 LATCH/HINGE STILE TCH 8 HINGE STILEo
o
Cellularpvc Reinforcement
9 SEE a a
= HARDWARE 1 39" iv m
h }
< CHART �r I--1.59" i I 1.59"�{
` 0r777 71
i� 0 v, a
0 2 o
L z
LOCK BLOCK iOP RAIL BOTTOM RAIL 46 w N
50 20 Long 42 Cellularpvc 45 Cellularpvc
HARDWARE CHART
w =
N Q �
1 MANUFACTURER MODEL o o
2 ^o
z LOCK SIGNATURE SERIES 45 Dn E:02 20 12 z
DOOR PANEL KWIKSET d
40 DEADBOLT: SIGNATURE SERIES 760 SCALE: N.T.S.
5
m
V YALE LOCK: YH COLLECTION DWG.BY: JK 3
DEADBOLT: YH COLLECTION(80 SERIES) CHN.BY: LFS
1�VERTICAL CROSS SECTION DRAWING NO.: N
2 FL-15220.E 0
n
SHEET_�L OF 7
z
.
�� ► -;� yy
a N
�''�� urrP��``` on°z°
U N •;
O
I D TYP.HEAD TYP.HEAD �l 2 u o z v
&JAMBS &JAMBS
maa�...
MASONRY J MASONRY .
OPENING OPENING r E `o i
' c�i
8 �a
FRAME x
NZ
UO
2XBUCK-\ D _ _ zo zz
Qo
2X BUCK a 3 m w�
N 15 o
U m Q.D]a o
O kINSWING — Oom_
~ u
N N
BUCKANCHORING STRIKEJAMS FRAMEANCHORING HINGEJAMB w o
Masonry 2X buck construction N
CONCRETE ANCHOR NOTES: o
I. Concrete anchor locations at the comers may be adjusted to maintain the min.
o edge distance to morforioints.
2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to a
a maintain the min.edge distance to mortarjoints,additional concrete anchors E i
omay be required to ensure the"MAX.ON CENTER"dimension are not exceeded. w F
—Ai
3. Concrete anchor table: N a F
0 AN MIN
MIN.CLEARANCE .MIN.:CLEARANCE 28 M K
GHUR ANCHOR ` , . ' •'
SIZE EMBEDMENT TO.MASONRY :. TO ADJACENT:. 10 O
WI TYPE EDGE ANCHOR _z
a
:r W ® 11 DATE:02/20/12 =
iAiCON 1/4" 1-1/4" 2" 4° 27 D M SCALE: N.T.S.
a DWG.BY: JK m'
® 1/4" I 1-1/4" 1" 4" 3 �
o UL7RAELCO CON cHN.BY: LFS
WOOD SCREW INSTALLATION NOTES: MA NG NO.: ¢
1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of LATCH d DEADBOLTDETAIL HINGE DETAIL
FL-15220.E
Uwood screws to prevent the splitting of wood. SHEET 5 OF 7 f
♦``............
=2:
`N,u
7 z y W• m ro
�C�♦ N "_
a N ••
" Eo 5 ° m W
m
H 9 28 G amn 9 °OIL
g LL
1. C Z°
10 J TYP.HEAD w
11 ❑ - �J &JAMBSCS
�To
MASONRY cYi
OPENING D]0
LATCH d DEADBOLT DETAIL 30 o ^`
HINGE DETAIL 3 0
FRAME a 5 m ZZ o
B0-MN QCr
U
�a 40
c 1XBUCK o
rn Cyi, a a
h
rV � �m
LINSWINGCONCRETE ANCHOR NOTES: z
s 1. Concrete anchor locations at the corners maybe adjusted to maintain the min. W o
edge distance to mortarjoints.. N
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to 0
maintain the min.edge distance to mortar joints,additional concrete anchors "
maybe required to ensure the"MAX.ON CENTER"dimension are not exceeded. Q
3. Concrete anchortoblo: STRIKEJAMB FRAME ANCHORING HINGE JAMB a
MIN.:CLEARANCE MIN.CLEARANCE Masonry I buck construction E
ANCHOR.* ANCHOR MIN j
oTO MASONRY 70.ADJACENT'.' w i
YPE. SIZE EMBEDMENT EDGE -ANCHOR'
a
O H
LLI :TW m
TA'C!ONO ' 1/4" 1.1/4" 2" 4" ^o 0
LCO`g a 1/4' I 1"1!4" 1" 4" DATE-02120112
°
SCALE: N.T.S.
ULTRACON °
1.
TA?CON"
3" 1.1/2" DWG.BY: JK m'
2 L=— CHK.BY: LFS ;
WOOD SCREW INSTALLAPON NOTES: DRAWING No.: rc
I.Maintoin a rnin:n:um 5/8"edge distance,I"end distance,&1"o.c.spacing of FL-15220.E
wood screws to prevent the splitting-of wood. a
SHEET 6 ar 7 N
s 0
4
�— BILL OF MATERIALS \\ v
IT:M d bESCR!.'7iON MATERIAL O10 �• �
A 1XBUCKSG>=0.55 WOOD
2Y BUCK SG>=0.55 WOOD Z * r
1 C /4"MAX.SHIM SPACE �j.., y� m
D 1 i4"X,2 3/4"ELCO OR ITW CONCRETE SCREW STEEL '. ) •.. ;Gy\\\ h a 0 m
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE ��'Y'' *P,`�`�C`_��`\ o d�Z
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 ALL!I t L, ° N
G .3/16"X 3-1 i4"PFH ITW CONCRETE SCREW STEEL a o z
H . 1/4"x 3-1/4"PFH"ELCO OR ITW CONCRETE SCREW STEEL 4.58' \ y g t° g m 0 W
I 1/4"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL I V` a in g m d a�
J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL ?
K #9 X 2-1/2"PFH WOOD SCREW STEEL ���LLL E o'z
L #8 X 2-1/2"PFH WOOD SCREW STEEL °W
1.1 48 Y,2"PFH WOOD SCREW STEEL I
2.36"
N l,N'x 3-1/4"PFH TTW CONCRETE SCREW-:. STEEL ! ~ --�
7. FORCE 5 WEATHERSTRIPPING BY ENDURA
NEAD d SIDE
8 CGMPRESSION WEATHERSTRIP QLONM BY SCHLEGEL 20 Jamb o —�N
9 �'X 4"BUTT HINGE STEEL Z o ww
10 #9 X 3/4"PFH WOOD SCREW STEEL Lo J o
11 #9 X 3/4"PFH WOOD SCREW STEEL 4.56 0 5 m
20 FINGER.JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD �w� �o
21 POLY FIBER JAMB COMP./VINYL a m� m.d
27- LATCH STRIKE PLATE STEEL [77�= 0
28 DEADBOLT PLATE STEEL I I o
29 OUTSWING THRESHOLD BY DLP ALUM./WOOD
30 ,INSWING VINYL DOOR BOTTOM SWEEP VINYL
33 INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM./WOOD 'm
21 HEAD d SIDE
40. DOOR PANEL-SEE DOOR.PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS '. rb.rlamb
41 DOOR SKIN(MIN.0.069'"THiCK)BY PLASTPRO FIBERGLASS m
42 TOP RAIL CELLULAR PVC a^
43 LATCH&HINGE STILE CELLULAR PVC 4.56 N
45 BOTTOM RAIL " CELLULAR PVC y z
s 46..Pi;POLYil_REIiAIct FOAM BY PLASTPRO`'- POLYURETHANE o 0
46 OLtI AND WNGE STILE REINFORCEMENT WOOD
wl Him
50 LOCK BLOCK(20"X 1.383') WOOD o
a ,, ADJUSTABLE INSWING THRESHOLD a d
c z I
n'
=
t 4.56' a
" i
F _O
2.03"
5 DATE:02/20/12
SCALE: N.T.S. °
DWG.BY: JK m
�I CNN.BY: LFS 3
`� --
UTSWING THRESHOLD BY DLP DRAWING NO.: Ix
FL-15220.6 N
0
SHEET ] OF 7 �
LL �