HomeMy WebLinkAboutEngineering M/ALUM ROOF AALUMROOF DMUDEOALUM ATTACNRgL .Dl.._..(ROOfWNF.OVFR
YRDGEO POLYSTYRENE INSULATION rRIDGED POLYSTYRENE INSULATION WSBXI 1H eM.9.]'O.C. PDGEW FACi0RY5EMA9 /B'O.0
FASCIAEOGEOETAL OR ®
EXISTWpM031lEHOMEROOF EYTNUOED,LLUN.ATTACHRVL FJ05TINOPATIOROOF
/ WSBXI III S.M.S.J'O.C. BUTYL RUSBERSEAM. GUTTER EDGEOETALCOACH ROOF C
BUIYLRUBBERSFAI i r 024 ALUM FLASHINOINTO PAN S _ CONNECTION DETAILS
/yl.'+ -a ANOGI MOCONTINUE •.______ ___ _
I i ,
BUM RUBBER SEAL '�,�'� FIASHINO TOO UTTER ' �L _ _, fOUiWSUUTDN Cy
INSULATION M4ALUIMROOF
UDt smsLATMCN RNL j� / WASHERS TO TOPOFEACHPAN 1� 1
/jbiJ IFS%11N 961.S9'O.C. \ `
SOP...Wy WAtlI�FI1', .024 ALUNROOF 11 ` , EXISTING % ~,\ ~ s b DO P.T.PTWONO'W.S. 8'O.C. TT c�
/ INSULATION ��l`�-T A / MOBILE NONE ROOF
2X3 P.T.BLOCN9 CUT TOF! 0
PMS./R)USJLS.PERPAN \PATIOPANROOF pj m
EnsnNpta EXISTING01 ��� s
OVERHANG
TYPICAL ROOF SECTION' ATTAcxNEN DErA +
FRAME POLYSTYRENE FOAM EXST(NGPAMROOF N
E%ISTWGkULt .T.B.
COLABEAM WERT EACH PAN
EXISTINGWALL
CHANNELATIO ItOWSTAIMESS STEEL HEXHEAD
FASTINGWAILCHANNEL D24ALUMROOF FROM ATTAOOAENTRAILTO EXISTING
ALTERNATE COACH&PATIO ROOF ATTACHMENT#1 ALTERNATE PATIO PAN ROO ATTACHMENT DETAIL" MOBREHOMEFMAE®SO.C.MIN.
2'RDGEDPMYSTYREN•E IN IMOBExIHOMS FRAME@ wrl¢uslnmourw
O Ch WALL N.T.S. F11EIAL1,11ATTACK RAIL
CONNECTION DETAIL(TITS) (N ) FIDSTING MOBLEHOME ROOF M 114 SA1.&YO.C. r JDMDEOALUMATTACHRAR fRYI'WfOEBUfTL R1/BSERO°NL r
A2/ALUM ROOF wl/eXt 1//S.M8.7'O.C. i i�/y y D1/ROLLAIUMD M r
3NFELT OHMPOF -BUll,RUBBERSELL INSULATION wY1F10®ATNL
MI ALUM ROOF PARS BUMRUSBFRSEA. / ',',/� ROOF A m Fc aN 0
7FUDGED POLYSTYRENE INSULATION X24ALWFWIINGWWPAN ,� Z
ANOCALLKOftCONTINUE Q
EOSTWGMOBILE HOME ROOF FXTRUOEOALUM.ATTACHPAL /j�j�/ ATTACHCOM.2Y1'P.T.10EA9TWO :
FLISHINO.TO GUTTER 2X3P.T.W//BKt'W. ®B
WSaYI V(SM8.70.0 i �T t 24$MSWNEOPRENE INTO EXWION4�fUACH FRAME MOBILE
0 HOMEFRA GWIIBd'W000 O p
BIRYLRIIBBERSFAL �/'- / ® AGNGTOSTR/JGNfEN
WASHERS TO TOP OF EACH PAN // ` WOOD ONLY,IN LIEU OF FULL FRAMING U
M/AlUIM ROOFFLlSFI1JG E2(ISTWO PANSd a 4t T D2IALUM GUTTER ATTACHNENT,PEROETAIS .
EXTRUDEDALUNLATTACH RAIL INSULATION INSERTS ,`� T`U�T�T1i E2ISTINGCOACH F2(iitUDEOAlUMWUMATIACHNFNT
WIB%11l/&.MS J'0.0 1A P.T.BLOCN9 CUTTOFITWTO 1 L FRAME RAILd/&1-1HSTANLESSSTEEL mN
WPP.T.WIINOAWFFRAMtE PANSW(1)189.M.&.PER PAN PCAEW9®E HOLES
?X1 P.T.WI S.® BUM RUBSERSFAL EXISTING EXISTING MOBLEHOME
.024ALUMROOF OYEAIWYO FMMW06ROOFING
POLYSTYRENE FOAM
PANS TONTOPOF �68 W9FATEAGHPAN GUTTER EDGE DETAIL ALTERNATE ATTACHMENT RAIL FASTENING#1 �i�m
EAM
N.T.S. N.T.S.
i
2X3 P,T.BLOCKS CUT TO FIT INTO 021 GALVALUME CLEAT
PANSW(2)IBSNS.PERPAN ,48.D.C.(TYP)
ALTERNATE PATIO PAN ROO ATTACHMENT DETAIL"B" v
EYI97WOPAMSW .02A`ALUM
COSTING COACH WSIMTION INSERTS
FRAME EXISTNGALUM. !�
COLMBEAM
BVMRUBBERSFAL ry
EXTRUDED ALUM.ATTACH PNI
r WDGm POLYSTYRENE INSULATION wIPW(I 1I/SMSS'O.0 .021ALUMROOF .024'ALUM 'mil
ALTERNATE COACH&PATIO ROOF ATTACHMENT#2 0 EFLAPPW° 2X3P.T.,l#W 2 NOGED POLYSTYRENE INSULATION6*4
CONNECTION DETAIL(NTS) (w14th WALL) .024ALUNROOF D WA@3'0.C. EXISTING MOBILE HOVE ROOF 8RIUDEDALUM.ATTACH RAIL BTYRENEBUTACHENE C
IFBXIIIes.MB.J'o.C. FACTORY SEAM DESIGN FOR RUBBERSFAUNT O ' y
ALUMINUM ROOFCOVERTp�GS BETWEEN SHEET SCLEAT BumaueBERSEu OVERSOLIDROOFSONLYPRODUCTAPPROVALgFL5739 r�
/ ''�,•' N.T.S. � a
.021 ALUM ROOF / < //�.021 ALUMFASW IJ N .
2'RDGEO POLYSTYRENE INSULATION FOAM FIIIEfl ��//// / ATADMCENT PATIO ROOF NOTES:
EXISTING MOBILE HOME ROOF EXTRUDEDALUMATTACHMIL EXISTING ACH fRAMING 2X2 P.LWIIB%]W.S.®B'0.0 PROVDFM4FIASHING IT
SDESION CONFORMS TO THE 2014 FLORIDA BUILDING CODE FORA y�
/ W/BXI IRSALSJ'O.C. WTOEXI9TWGCMCN FRAME INTO PATIOROOF(MINB') EGORY JIBUILDINB FORWINDLOAOINGOF165MPH,EXPO.SURECAS
B'Y`R "` DOUBLE WIDE RIDGE DETAIL ////�� wM85119®12OC. ERMINEOBVA9CESTANDAR07S DESIGN CONFORMS TO FLORID STATI/TE 16G2AOBf FOR W g m
/AUNRWF MOBILEIMANUFACFURED HOME REPAIR AND REMODELING. F�
INSULATION N'T's' 9TIN0 EXTRUDED WALCHANNEL 3J ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY.IT
`7) EXISTING COACH SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
FRAME 4J THE ROOF COVERING SHALL NOT OVERHANG THE EXISTiNO ROOF. !fq
Ell • BUTYL RUBBER SEAL F%TftuDEDAlUII.ATMCN RAIL CV
RITY OF
INTOEXCIP. SRNGWil ]'WS. IB'0. F• ��S) K 8.M5.]'O.C• / 5) ROOF.THE STRUCTURE.OF THE EXISTING ROOF SHOULDRESPONSIBLE FOR BE ABLE ToISTINO eN
INTO E7091W6j'AALM FRAM <✓'�/ i r RIDGED POLYSTYRENE INSULATIONW
P.LWOOD BLOO(wl SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF B'YSTEM �N
-i OVERLAPPING B. MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 12-0. Od PSIO'W.S SPANNING )
.02/NUMROOF T09TRNGHTENW000ONLY •'FASCIA EDGE DETAIL 7J MAXIMUM WIDTH OF DOUBLE WIDE MOBILE HOME NOT TO EXCEE0IB'-0
D�-/� N.T.B. B.) INSULATION TO BE POLYSTYRENE FORM APROX.DENSITY I#PER B.F.
FRAME COACN ✓�'�i i, 9.) MAXIMUM HEIGHT'OF MOBILE HOME NOT TO EXCEED I5•-0'.
SPAN
ROOF b
FRAME lr,�i , ,�i i, 10.)THEMINIMUMR-ALLIEOFTHE2'ALL ROOF SULATIFLASHING TDBE.01/ALUM
.
MAXNAX SPAN 1/F ',', 11.)THE R�VALUE OF THE 2'EPS INBNLATION IS R-8.7.
TAPERED INSULATIONAS REQUIRED ' ' /' SHEETNa: S, O(2
EXiSTINOWALLCWVLNEL FOAM FILLER OWNER: a/>t'Lja ArLp, HAD.E,�A,..A N AID UNLESS. TE 4
d
ALTERNATE COACH&PATIO ROOF ATTACHMENT#3 O°sT°DCENTERG EXISTINGCOA
P OLFMMWG ADDRESS: o H J/loN C LfZ S BWI
E p CONNECTION DETAIL(NTS). (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL CITY:• P\,F ,-E STATE:FL_ ZIP.'"" A I �/,
UBING ALTERNATE 01 ATTACHMENT(NTS) JAMES BUSH U SE,F.E. Y
LOT# BLOCK#. RANGE PROFESSIONAL ENGINEER 2031l
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C STATE OF FLORIDA c=i
EXTRUDEDALUM.ATTACH RAIL BUT RUBBER SEAL I
wl NB%I 1/4 S.M.S.3'O.C.
2}4'PT CONT.w/KS�3'WOOD e.:REWS®6'
BO m
t7a12}.024 ALUM CAP O.C.TO RIDGE BEAM 61-H 'WOOD ` Np
SCREW TO EACH TRUSS
'�A , FiZj� \\ .024 ALUM ROOF T RIDGED POLYSTYRENE INSULATION �...•
v` 2}4'WOODTRUSS® V h f0
RULED ALUM.ATTACH RAIL
24'D.C.w/12'SHEATHING 1p
wl,RBX1IMS.M.S.3'O.C.
BUMRUBBER SEAL L� N
� k r o
EEOUTTE
FASCIA EDGE
&1 �9
DETAILS,
®2.P.T.
o c TOOFFA SCIA.114'eYW CREWS 4
MA%2B'WIDTH MAX 1B'O.H.—1 TO EACH TRUSS TAIL@24'O.C.
CONTINUOUS
EXTRUDEDALUN.ATTACH RAIL 2'FASCIA TYP.
B2IALUN ROOF vdtS1U 1119MS.Y0.G
7 RIOGEO POLYSTTAE It BUfriRUBBERSEAL PARK MODEL DETAIL A
UI9UURON BMDP ELINT%SOIEWS BYO.C.THRU N.T.S. Z
�BOAOEO PANEL IASHINGSTING BEAM
D21 ALUM FIA9NBI0 � 0
E%Ni MALUMATEACH fWI
MleXI Ill SM 'O.C. U
BUT1i RUBBERSEAL
YNPITHICKSONDEOPANFL BUMRUBBERSEAL N
��A2/ALUN F11519N0 EXTRUDED ALUM.ATTACH RAIL m
w/MB%11p S.M.S.31O.C. ', y
NOTE: ♦.
NAXI2SPAN BONDED PANEL 12}/Tc024 ALUM CAP 2}4'PT CONT.w12-MBx3'W000 SCREWS TO EACH TRUSS
j I'NAY OH E:qq
/ LAP OF ROOF ROLL TOE ON
WNWAR SIDE \ Thal q m
FIUSTINOALUN. FASTWO DOWNWARD BIDE _ ,
COL am / ° D / ���� .024 ALUM ROOF_ 2'RIDGED POLYSTYRENE INSULATION q
OR FRAMING .
,J �'l'I n4 WOOD muss® x-T
BONDED PANEL ROOF EDGE DETAIL#2 f' 24'O.C.w/1fYSHEATHING / TRUDED ALUM.ATTACH RAIL A$v
,e I//// wl YB2tl,p 6.M.9.3*G.0. (� � .
N.T.B. ` ��<� lz
BUTYL RUBBERSEAL
SEEGUTTER& r, N
FASCIA EDGE ^I q
jDETAILS,S-1
to
2
2s4 P.T.wlgBO'W0006CREWS
A1A%14'WIDTH MAX IB'O.H.--� ®12'O.C.TO FASCIAwl,4W' 11y �
TO EACH TRUSS TAIL®24'O.C. 1f<��. zk
CONTINUOUS
2'FASCIATYP. fY1 a
JD24ALUMRDOF PARK MODEL DETAIL B y b EXTRUDED ALUML ATTACH RAIL
IN RKXfOPOLY9TYRE1IE N.T.S.
INSULATION MIk7(1111 SAI.S.YO.C. W q�+
�p BUzIU9BERSEAL
U4ALUMRASKN0 r 'hh4 i
� Q�q
YNINTHICK BOHDEDPANEL
jj/ 7lTPf d2®0'SNS 04'INTO �Oto
NOTE: OBRUDEDNETAL&GONEUPANEL W
MAX 12SPAN BONDED PANEL \ g q
j-1'WXO.H F%fRIIG.I. bqW
COL&BBEAM EXISTING GRGUITFA1 �C� - SHEET Nay S2 O(2 O
V \\\\\ ;
OR FRAMING \ OWNER: NOT OWITLESSDATE 4
BONDED PANEL ROOF EDGE DETAIL#1 ADDRESS:
N.T.S. STATE: ZIP;CITY: DAMES BU6H E, Y
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C LOTq BLocXw RANGE PROFESSIONAL
2W11 =
O 6TATE OF FLORIOA U