Loading...
HomeMy WebLinkAboutEnergy Code` FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: Walpole Residence BuilderName: Street: Permit Office: City, State, Zip: Fort Pierce, FL, 32949- Permit Number. Owner. Jurisdiction: Design Location: FL, ST LUCIE CO INTL 1. New construction or existing New (From Plans) 9. Wall Types (3492.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.0 3492.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2543.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2543.00ft2 6. Conditioned floor area above grade (It) 2543 b. NIA R= ft2 c. N/A R= ft2 Conditioned floor area belowgrade ff) 0 11. Ducts R ft2 7. Windows (396.0 sqft.) Description Area a. Sup: First Floor Main, Ret: First Floor Main, AH: Firs 6 321 a. U-Factor: Sgl, U=0.47 396.00 ft2 b. Sup: Attic, Ret: office, AH: office 6 192 SHGC: SHGC=0.30 c. Sup: Attic, Ret 2nd floor, AH: 2nd floor 6 220 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 17.6 SEER:16.00 SHGC: b. Central Unit 35.0 SEER:16.00 c. U-Factor. N/A ft2 c. Central Unit 17.6 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heat 17.1 COP:1.00 SHGC: b. Electric Strip Heat 34.1 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. c. Electric Strip Heat 17.1 COP:1.00 Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap:40 gallons 8. Floor Types (2541.8 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1990.10 ft2 b. Conservation features b. Raised Floor R=19.0 551.70 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.156 Total Proposed Modified Loads: 43.08 PASS Total Standard Reference Loads: 55.47 1 hereby certify that the plans and specifications covered by Review of the plans and Qf't1 STgT.. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE. April 15th, 2014--�- Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this b ildi g, d, is in compliance Florida Statutes. with the Florida Ene d OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 1 of 6 PROJECT Title: Walpole Residence Bedrooms: 3 Address Type: StreetAddress Building Type: User ConditionedArea: 2543 Lot# Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce, FamilyType: Single-family FL, 32949- New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design DailyTemp DesignLocation TMYSite Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO INTL FL ST LUCIE_CO INTL 2 39 90 70 75 722 58 Medium BLOCKS Number Name Area Volume 1 First Floor 1510 13590 2 Garage Office 481 4329 3 Second Floor 552 4968 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 First Floor Main 1510 13590 Yes 2 1 1 Yes Yes Yes 2 office 390 3510 No 0 1 Yes Yes Yes 3 cl 25 225 No 0 1 Yes Yes Yes 4 bath 66 594 No 0 1 Yes Yes Yes 5 2ndfloor 552 4968 No 2 2 1 Yes Yes Yes FLOORS # FloorType SpacePerimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation FirstFloorMain 176.5ft 0 1509.6ftz ____ 1 0 0 2 Slab -On -Grade Edge Insulation office 63 ft 0 389.7 ft2 1 0 0 3 Slab -On -Grade Edgelnsulation cl 8.3 ft 0 24.8 ft2 1 0 0 4Slab-On-Grade Edge Insulation bath 17.3ft 0 66ft2 — 1 0 0 5 Raised Floor 2nd floor __- _-_ 551.7 ftz 19 0 1 0 4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 2 of 6 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2680 ft2 0 ft2 Medium 0.5 No 0.9 No 0 18.4 ATTIC in) Area RBS IRCC V # Type Ventilation Vent Ratio (1 1 Full attic Vented 300 2543 ft2 N N CEILING # CeilingType Space R Value Area Framing Frac Truss Type 1 Under Attic (Vented) First Floor Main 30 1510ft2 0.1 Wood 2 Under Attic (Vented) office 30 390 ft2 0.1 Wood 3 Under Attic (Vented) cl 30 25 ft2 0.1 Wood 4 Under Attic (Vented) bath 30 66 ft2 0.1 Wood 5 Under Attic (Vented) 2nd floor 30 552 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space R--Value Et In Et In Area RAW- EraCtinn Ahqor rrRfJP% 1 N Exterior Concrete Block- Int InstEirst Floor Mai 4 42 6 9 0 382.5 ft2 0 0 0.8 0 2 E Exterior Concrete Block - Int InsLEirst Floor Mai 4 45 9 9 0 411.8 ft2 0 0 0.8 0 3 S Exterior Concrete Block - Int InsdFirst Floor Mai 4 42 6 9 0 382.5 ft2 0 0 0.8 0 4 W Exterior Concrete Block - Int InstEirst Floor Mai 4 45 9 9 0 411.8 ft2 0 0 0.8 0 5 N Exterior Concrete Block - Int Insul office 4 13 6 9 0 121.5 ft2 0 0 0.8 0 6 E Exterior Concrete Block- Int Insul office 4 5 6 9 0 49.5 ft2 0 0 0.8 0 7 S Exterior Concrete Block - Int Insul office 4 24 3 9 0 218.3 ft2 0 0 0.8 0 8 W Exterior Concrete Block - Int Insul office 4 19 9 9 0 177.8 ft2 0 0 0.8 0 9 E Exterior Concrete Block - Int Insul cl 4 8 3 9 0 74.3 ft2 0 0 0.8 0 10 N Exterior Concrete Block- Int Insul bath 4 11 0 9 0 99.0 ft2 0 0 0.8 0 11 E Exterior Concrete Block- Int Insul bath 4 6 0 9 0 54.0 ft2 0 0 0.8 0 12 S Exterior Concrete Block- Int Insul bath 4 0 3 9 0 2.3 ft2 0 0 0.8 0 13 N Exterior Concrete Block - Int Insul 2nd floor 4 41 3 9 0 371.3 ft2 0 0 0.8 0 14 E Exterior Concrete Block - Int Insul 2nd floor 4 20 3 9 0 182.3 f12 0 0 0.8 0 15 S Exterior Concrete Block - Int Insul 2nd floor 4 41 3 9 0 371.3 ft2 0 0 0.8 0 16 W Exterior Concrete Block- Int Insul 2nd floor 4 20 3 9 0 182.3 ft2 0 0 0.8 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood First Floor Mai None .39 3 7 21 ft2 2 W Wood FrstFloorMai None .39 3 7 21 ft2 4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation IntShade Screening 1 E 2 Metal Low-E Single Yes 0.47 0.3 30.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 2 S 3 Metal Low-E Single Yes 0.47 0.3 42.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 3 S 3 Metal Low-E Single Yes 0.47 0.3 30.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 4 S 3 Metal Low ESingle Yes 0.47 0.3 40.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 5 W 4 Metal Low-E Single Yes 0.47 0.3 25.0 ft2 2 ft 0. in 1 ft 0 in None Exterior 5 6 W 4 Metal Low-E Single Yes 0.47 0.3 30.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 7 W 4 Metal Low-ESingle Yes 0.47 0.3 10.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 8 S 7 Metal Low-E Single Yes 0.47 0.3 14.6 ft2 2 ft 0 in 1 ft 0 in None Exterior5 9 S 7 Metal Low-E Single Yes 0.47 0.3 15.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 10 W 8 Metal Low-ESingle Yes 0.47 0.3 42.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 11 W 8 Metal low-ESingle Yes 0.47 0.3 15.4 ft2 2 ft 0 in 1 ft 0 in None Extedor5 12 W 8 Metal Low-ESingle Yes 0.47 0.3 15.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 13 E 14 Metal Low-ESingle Yes 0.47 0.3 15.0 ft2 2 It 0 in 1 ft 0 in None Exterior5 14 S 15 Metal Low-ESingle Yes 0.47 0.3 42.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 15 W 16 Metal Low-E Single Yes 0.47 0.3 30.0 ft2 2 ft 0 in 1 ft 0 in None Exterior5 GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 651.24 ft2 651.24 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 2001.1 109.86 206.6 .225 5.246 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 17.07 kBtu/hr 1 sys#1 2 Electric Strip Heat None COP: 1 34.13 kBtu/hr 2 sys#2 3 Electric Strip Heat None COP: 1 17.07 kBtu/hr 3 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 17.6 kBtu/hr cfm 0.7 1 sys#1 2 Central Unit Split SEER: 16 35 kBtu/hr cfm 0.7 2 sys#2 3 Central Unit Split SEER: 16 17.6 kBtu/hr cfm 0.7 3 sys#3 4/15/2014 3:44 PM EnergyGauge®USA- FlaRes2010Section405.4.1 Compliant Software Page 4 of 6 HOT WATER SYSTEM # SystemType SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ftZ DUCTS —Supply— — Return — Air CFM25 CFM25 HVAC# # Location R Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 First Floor Mai 6 321 ftZ First Floor Mai 175 ftZ DefaultLeakage First Floor (Default) c(Default) c 1 1 2 Attic 6 192 ftZ office 192 ftZ DefaultLeakage office (Default) c(Default) c 2 2 3 Attic 6 220 ftZ 2nd floor 220 ftZ DefaultLeakage 2nd floor (Default) c(Default) c 3 3 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Feb Jan HFeb Heating Jan Feb Coolin HJan ar ar Mar [ ] Apr [ } Apr [ ] May ] May [X] Jun [X] Jul [ ] Jun Jul [X] AugX] 3 AuE Se [ Oct ] Sep [) Oct Nov Nov MNov (] Dec [X] Dec Venting [X] Apr l ] may [[ ] Jun ]Jul] E l Aug E l Sep [X] Oct [ j Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 80 78 78 78 78 78 78 78 78 78 78 80 78 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 66 68 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 66 68 68 66 68 66 68 68 68 68 68 68 1 68 68 68 68 68 68 66 68 66 4/15/2014 3:44 PM EnergyGauge®USA - FlaRes2010 Section405.4.1 Compliant Software Page 6 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Fort Pierce, FL, 32949- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with'mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. , Fort Pierce, FL, 32949- 1. Nev/ construction or existing New (From Plans) 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=4.0 3492.00 ft2 2. Single family or multiple family Single-family b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 3 d. N/A R= ft2 4. Number of Bedrooms 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2543.00 ft2 6. Conditioned floor area (ft2) 2543 b. N/A R= ft2 c. N/A R= ft2 7. Windows** Description Area 11. Ducts R ft2 a. U-Factor: Sgl, U=0.47 396.00 ft2 a. Sup: First Floor Main, Ret: First Floor Main, AH: Fi 6 321 SHGC: SHGC=0.30 b. Sup: Attic, Ret: office, AH: office 6 192 b. U-Factor: N/A ft2 c. Sup: Attic, Ret: 2nd floor, AH: 2nd floor 6 220 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit b. Central Unit 17.6 SEER:16.00 35.0 SEERA6.00 SHGC: c. Central Unit 17.6 SEER:16.00 d. U-Factor. N/A ft2 13. Heating systems kBtu/hr Efficiency - SHGC: a. Electric Strip Heat 17.1 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. b. Electric Strip Heat 34.1 COP:1.00 Area Weighted Average SHGC: 0.300 c. Electric Strip Heat 17.1 COP:1.00 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1990.10 ft2 a. Electric EF: 0.97 b. Raised Floor R=19.0 551.70 ft2 b. Conservation features c. N/A R= ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code Builder Signature: Date:'" Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient ,mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405A.1 Compliant Software