HomeMy WebLinkAboutEnergy Code` FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: Walpole Residence
BuilderName:
Street:
Permit Office:
City, State, Zip: Fort Pierce, FL, 32949-
Permit Number.
Owner.
Jurisdiction:
Design Location: FL, ST LUCIE CO INTL
1. New construction or existing
New (From Plans)
9. Wall Types (3492.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block- Int Insul, Exterior
R=4.0 3492.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (2543.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2543.00ft2
6. Conditioned floor area above grade (It)
2543
b. NIA
R= ft2
c. N/A
R= ft2
Conditioned floor area belowgrade ff)
0
11. Ducts
R ft2
7. Windows (396.0 sqft.) Description
Area
a. Sup: First Floor Main, Ret: First Floor Main, AH: Firs 6 321
a. U-Factor: Sgl, U=0.47
396.00 ft2
b. Sup: Attic, Ret: office, AH: office
6 192
SHGC: SHGC=0.30
c. Sup: Attic, Ret 2nd floor, AH: 2nd floor
6 220
b. U-Factor. N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
a. Central Unit
17.6 SEER:16.00
SHGC:
b. Central Unit
35.0 SEER:16.00
c. U-Factor. N/A
ft2
c. Central Unit
17.6 SEER:16.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
ft2
a. Electric Strip Heat
17.1 COP:1.00
SHGC:
b. Electric Strip Heat
34.1 COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
c. Electric Strip Heat
17.1 COP:1.00
Area Weighted Average SHGC:
0.300
14. Hot water systems
a. Electric
Cap:40 gallons
8. Floor Types (2541.8 sqft.)
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1990.10 ft2
b. Conservation features
b. Raised Floor
R=19.0 551.70 ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.156
Total Proposed Modified Loads: 43.08
PASS
Total Standard Reference Loads: 55.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
Qf't1 STgT..
this calculation are in compliance with
the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
DATE. April 15th, 2014--�-
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this b ildi g,
d, is in compliance
Florida Statutes.
with the Florida Ene d
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 1 of 6
PROJECT
Title: Walpole Residence
Bedrooms: 3
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 2543
Lot#
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
BuilderName:
RotateAngle: 0
Street:
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
Fort Pierce,
FamilyType: Single-family
FL, 32949-
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design DailyTemp
DesignLocation TMYSite Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO INTL FL ST LUCIE_CO INTL 2 39 90
70
75 722
58
Medium
BLOCKS
Number Name Area
Volume
1 First Floor 1510
13590
2 Garage Office 481
4329
3 Second Floor 552
4968
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 First Floor Main 1510
13590 Yes 2
1
1 Yes
Yes
Yes
2 office 390
3510 No 0
1 Yes
Yes
Yes
3 cl 25
225 No 0
1 Yes
Yes
Yes
4 bath 66
594 No 0
1 Yes
Yes
Yes
5 2ndfloor 552
4968 No 2
2
1 Yes
Yes
Yes
FLOORS
# FloorType SpacePerimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation FirstFloorMain
176.5ft 0
1509.6ftz
____
1 0
0
2 Slab -On -Grade Edge Insulation
office 63 ft 0
389.7 ft2
1 0
0
3 Slab -On -Grade Edgelnsulation
cl 8.3 ft 0
24.8 ft2
1 0
0
4Slab-On-Grade Edge Insulation
bath 17.3ft 0
66ft2
—
1 0
0
5 Raised Floor 2nd floor __- _-_
551.7 ftz
19
0 1
0
4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 2 of 6
ROOF
Roof
Gable
Roof
Solar
SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color Absor.
Tested
Tested
Insul.
(deg)
1
Hip Metal 2680 ft2
0 ft2
Medium 0.5
No
0.9
No
0
18.4
ATTIC
in)
Area
RBS
IRCC
V
#
Type Ventilation
Vent Ratio (1
1
Full attic Vented
300
2543 ft2
N
N
CEILING
#
CeilingType Space
R Value
Area
Framing Frac
Truss Type
1
Under Attic (Vented) First Floor Main
30
1510ft2
0.1
Wood
2
Under Attic (Vented) office
30
390 ft2
0.1
Wood
3
Under Attic (Vented) cl
30
25 ft2
0.1
Wood
4
Under Attic (Vented) bath
30
66 ft2
0.1
Wood
5
Under Attic (Vented) 2nd floor
30
552 ftz
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Belo w
Space
R--Value Et
In
Et In
Area RAW-
EraCtinn
Ahqor
rrRfJP%
1
N
Exterior Concrete Block- Int InstEirst Floor Mai
4 42
6
9 0
382.5 ft2
0
0
0.8
0
2
E
Exterior Concrete Block - Int InsLEirst Floor Mai
4 45
9
9 0
411.8 ft2
0
0
0.8
0
3
S
Exterior Concrete Block - Int InsdFirst Floor Mai
4 42
6
9 0
382.5 ft2
0
0
0.8
0
4
W
Exterior Concrete Block - Int InstEirst Floor Mai
4 45
9
9 0
411.8 ft2
0
0
0.8
0
5
N
Exterior Concrete Block - Int Insul office
4 13
6
9 0
121.5 ft2
0
0
0.8
0
6
E
Exterior Concrete Block- Int Insul office
4 5
6
9 0
49.5 ft2
0
0
0.8
0
7
S
Exterior Concrete Block - Int Insul office
4 24
3
9 0
218.3 ft2
0
0
0.8
0
8
W
Exterior Concrete Block - Int Insul office
4 19
9
9 0
177.8 ft2
0
0
0.8
0
9
E
Exterior Concrete Block - Int Insul cl
4 8
3
9 0
74.3 ft2
0
0
0.8
0
10
N
Exterior Concrete Block- Int Insul bath
4 11
0
9 0
99.0 ft2
0
0
0.8
0
11
E
Exterior Concrete Block- Int Insul bath
4 6
0
9 0
54.0 ft2
0
0
0.8
0
12
S
Exterior Concrete Block- Int Insul bath
4 0
3
9 0
2.3 ft2
0
0
0.8
0
13
N
Exterior Concrete Block - Int Insul 2nd floor
4 41
3
9 0
371.3 ft2
0
0
0.8
0
14
E
Exterior Concrete Block - Int Insul 2nd floor
4 20
3
9 0
182.3 f12
0
0
0.8
0
15
S
Exterior Concrete Block - Int Insul 2nd floor
4 41
3
9 0
371.3 ft2
0
0
0.8
0
16
W
Exterior Concrete Block- Int Insul 2nd floor
4 20
3
9 0
182.3 ft2
0
0
0.8
0
DOORS
#
Omt DoorType Space
Storms U-Value Width
Height
Area
Ft
In
Ft In
1
N Wood First Floor Mai
None
.39
3
7
21 ft2
2
W Wood FrstFloorMai
None
.39
3
7
21 ft2
4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID Frame
Panes
NFRC
U-Factor SHGC
Area Depth
Separation IntShade
Screening
1
E 2 Metal
Low-E Single
Yes
0.47 0.3
30.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
2
S 3 Metal
Low-E Single
Yes
0.47 0.3
42.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
3
S 3 Metal
Low-E Single
Yes
0.47 0.3
30.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
4
S 3 Metal
Low ESingle
Yes
0.47 0.3
40.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
5
W 4 Metal
Low-E Single
Yes
0.47 0.3
25.0 ft2 2 ft 0. in
1 ft 0 in
None
Exterior 5
6
W 4 Metal
Low-E Single
Yes
0.47 0.3
30.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
7
W 4 Metal
Low-ESingle
Yes
0.47 0.3
10.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
8
S 7 Metal
Low-E Single
Yes
0.47 0.3
14.6 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
9
S 7 Metal
Low-E Single
Yes
0.47 0.3
15.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
10
W 8 Metal
Low-ESingle
Yes
0.47 0.3
42.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
11
W 8 Metal
low-ESingle
Yes
0.47 0.3
15.4 ft2 2 ft 0 in
1 ft 0 in
None
Extedor5
12
W 8 Metal
Low-ESingle
Yes
0.47 0.3
15.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
13
E 14 Metal
Low-ESingle
Yes
0.47 0.3
15.0 ft2 2 It 0 in
1 ft 0 in
None
Exterior5
14
S 15 Metal
Low-ESingle
Yes
0.47 0.3
42.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
15
W 16 Metal
Low-E Single
Yes
0.47 0.3
30.0 ft2 2 ft 0 in
1 ft 0 in
None
Exterior5
GARAGE
#
FloorArea
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
651.24 ft2
651.24 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Best Guess
.0003
2001.1 109.86 206.6 .225
5.246
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COP: 1
17.07 kBtu/hr
1
sys#1
2
Electric Strip Heat
None
COP: 1
34.13 kBtu/hr
2
sys#2
3
Electric Strip Heat
None
COP: 1
17.07 kBtu/hr
3
sys#3
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow SHR
Block
Ducts
1
Central Unit
Split
SEER: 16
17.6 kBtu/hr
cfm 0.7
1
sys#1
2
Central Unit
Split
SEER: 16
35 kBtu/hr
cfm 0.7
2
sys#2
3
Central Unit
Split
SEER: 16
17.6 kBtu/hr
cfm 0.7
3
sys#3
4/15/2014 3:44 PM EnergyGauge®USA- FlaRes2010Section405.4.1 Compliant Software Page 4 of 6
HOT WATER SYSTEM
# SystemType
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # CompanyName
System Model# CollectorModel# Area
Volume
FEF
None None
ftZ
DUCTS
—Supply—
— Return —
Air
CFM25 CFM25
HVAC#
# Location R Value Area
Location
Area
LeakageType
Handler
TOT OUT
QN
RLF
Heat Cool
1 First Floor Mai
6 321 ftZ
First Floor Mai 175 ftZ
DefaultLeakage
First Floor
(Default) c(Default) c
1 1
2 Attic
6 192 ftZ
office
192 ftZ
DefaultLeakage
office
(Default) c(Default) c
2 2
3 Attic
6 220 ftZ
2nd floor
220 ftZ
DefaultLeakage
2nd floor
(Default) c(Default) c
3 3
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Feb
Jan HFeb
Heating Jan Feb
Coolin HJan
ar
ar
Mar
[ ] Apr
[ } Apr
[ ] May
] May
[X] Jun [X] Jul
[ ] Jun Jul
[X] AugX]
3 AuE
Se [ Oct
] Sep [) Oct
Nov
Nov
MNov
(] Dec
[X] Dec
Venting
[X] Apr
l ] may
[[ ] Jun ]Jul]
E
l Aug
E
l Sep [X] Oct
[ j Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2 3
4
5 6
7
8 9
10
11
12
Cooling (WD) AM
PM
78
80
78 78
80 78
78
78
78 78
78 78
78
78
78 80
78 78
80
78
80
78
80
78
Cooling (WEH) AM
PM
78
78
78 78
78 78
78
78
78 78
78 78
78
78
78 78
78 78
78
78
78
78
78
78
Heating(WD) AM
PM
66
68
66 66
68 68
66
68
66 68
68 68
68
68
68 68
68 68
68
68
68
66
68
66
Heating (WEH) AM
PM
66
68
66 66
68 68
66
68
66 68
68 68
68
68
68 1 68
68 68
68
68
68
66
68
66
4/15/2014 3:44 PM EnergyGauge®USA - FlaRes2010 Section405.4.1 Compliant Software Page 6 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
Fort Pierce, FL, 32949-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with'mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters
minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool
heaters minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into
two or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
4/15/2014 3:44 PM EnergyGauge®USA -FlaRes2010 Section405.4.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 78
The lower the EnergyPerformance Index, the more efficient the home.
, Fort Pierce, FL, 32949-
1. Nev/ construction or existing
New (From Plans)
9. Wall Types
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.0 3492.00 ft2
2. Single family or multiple family
Single-family
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
3
d. N/A
R= ft2
4. Number of Bedrooms
10. Ceiling Types
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 2543.00 ft2
6. Conditioned floor area (ft2)
2543
b. N/A
R= ft2
c. N/A
R= ft2
7. Windows** Description
Area
11. Ducts
R ft2
a. U-Factor: Sgl, U=0.47
396.00 ft2
a. Sup: First Floor Main, Ret: First Floor Main, AH: Fi 6 321
SHGC: SHGC=0.30
b. Sup: Attic, Ret: office, AH: office
6 192
b. U-Factor: N/A
ft2
c. Sup: Attic, Ret: 2nd floor, AH: 2nd floor
6 220
SHGC:
12. Cooling systems
kBtu/hr Efficiency
c. U-Factor. N/A
ft2
a. Central Unit
b. Central Unit
17.6 SEER:16.00
35.0 SEERA6.00
SHGC:
c. Central Unit
17.6 SEER:16.00
d. U-Factor. N/A
ft2
13. Heating systems
kBtu/hr Efficiency
- SHGC:
a. Electric Strip Heat
17.1 COP:1.00
Area Weighted Average Overhang Depth:
2.000 ft.
b. Electric Strip Heat
34.1 COP:1.00
Area Weighted Average SHGC:
0.300
c. Electric Strip Heat
17.1 COP:1.00
8. Floor Types
Insulation
Area
14. Hot water systems
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
1990.10 ft2
a. Electric
EF: 0.97
b. Raised Floor
R=19.0
551.70 ft2
b. Conservation features
c. N/A
R=
ft2
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code
Builder Signature: Date:'"
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
,mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405A.1 Compliant Software