A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
SPAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-Or ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY. A
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less A 30' to 60' Span A
o degrees Sprea er Bar
or less
2 Approx 2/3 to
TIgLine �;:�Gn approx. Line r-- 1/2 of Span
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane used. Truss must be set this way if crane used.
Truaa le an -.ample, your truss may not match. This is an example, truss may not match.
Insist crane operator sets truss this way. Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
A1F=:Z_ h1fh%I"®IL—EF2 "OTI�
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
Carrying Girder
For Truss to Truss
Connections seeI
hanger/connector ails must be as
bs o
schedule in engineering Dome angle nashown. Guide ils.
package.
Carried Truss
SEAT PLATES BY CHAMBERS
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF V-0"
ABOVE FINISHED FLOOR
Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers A
' V L
METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN
i , I
�_ 26 8' -- 1 21'
upset=1/4" heel=4 3/16"
SQUARE CUT END
2 x 4 Top Chord
WALL HEIGHT 9'
TYPICAL END DETAIL
FABRICATION AGREEMENT
TRUSSES CANNOT SE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal descdPtion of the property where the trusses will be Installed Is:
The undersigned acmowledges and agrees:
1. Trusses will be made In strict accordance with this true placement diagram layout,
whtdt is the sob eult alfty for determIndng "St"'
fabrication attire
ruesee.
2. All dlrnensbn5 In this layout have been verified by the undersigned.
3. Unlew written notice Is provided by cerlfied mall to Chambers Truss within tan (10)
days of delivery the undersigned agrees that
no beckMargas velll lea -day'
the event
such written notice Is fumished Chambers True- -hall have three (3) bu�neas days in which
to begin "i required, or to eubetaute other !ueses, at Chambers opfbn.
4. The undesigned acknowledges receipt of'BCSI 1-03"=try sheet by TPI 8 WTCA.
4.6. Delivery la to job site. It Ia the buyens rssponelbllity 90 make t'utishe Job atta suitable for
Portion of the Job site for delivery. Chambers ss stith
ll belr aponalblebfo d14 Dmp delivery only.
The buyer Is resport Ii ie for additional delivery expenat d Chambers Tru le has to redeliver
Duyersi presponslble to Ch mien Trual I,,VGtZ 8 r�r due tnot o a t. condltred 10, ��ls.ary of trusses.
8, prow se sbowri in paragraph 7 below is subject to change If any changes are made In
this layout. A $50 per hour fa for revisions may be charged by Chambers Trua,
7. This is a PURCHASE ORDER to Chambers. True$ of the sum agreed to, or it nd-
agreement a reasonable price. Invoice will be made on delivery and paid within terms of net
on delhrery lni may be made at scheduled date of delivery If buyer cannot accePI
delivery of fabricated trusses. The undersigned agrees to pay Chambers Trues reasonable
attomeys fee for collections In event of payment not timely made. 1-1R %per month service
charge will be added for all sums not paid within terms.
8. Signature or In8lals anywhere on this shear constitutes agreement to all terms herein.
9. In conaidaretk�n of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and all indebtedness aver to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Induding attomeye fees, it default In payment for material be made by the
recipient.
10. In the event of any litigation concerning this agreement, the gems furnished hereunder
or Payments referred to herein, theparties agree that the sale venue far any such action will
be Saint 6ucle County, Florida.
11. Design responslbllldes are per "National Standard And Recommended Guidelines On
Rasponslbllitles For Construction Using Metal Plate Connected Wood Trusses
ANSVMVWrCA 4 - 2002'"
A spreader Err may lea regn�led per'19CSI 1 �" te Pint Muy &
Multiple ply trusses must be fastened together per engineering
before they, are not failure to do so can resuk In roof collapse"
Temporary mind permanent bracing are required and can save life
and property and Is the responsibility of the truss erector.
Study the contents of the Information packet Included on delNerl
before settling trusses.
ryldwea rntatbssstand!seed pwdodp to prensdk*" &
Tnuasss must be sot plumb and square
Do not salt bunks or stack of plywood, roofing material or any
other cont:entrated loads on trusses, this can cause collapse"
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVEREDpWITH TRUpS>3E8 TO SETT®R�USSES
CHAMBERS TRUSS INC
moo
3105 Oleander Avenue
Fort Pierce; Florida 34982-6423
00-551-5932
Fort Pierce 772466-2012 Fax 772-465"8711
vero Beach 772-589-2012 Stuart T72-288J302
Web Site: CHAMBERSTRUSS-COM
Frr all• MAII rraf:MAMRFRSTR11S3.G0M
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method Main Wind Force Resisting
Roofing Material Metal Roof
Loading in PSF Roof R.D.L.
Top Chord Live 20
Top Chord Dead 7 4.2
Bottom Chord Live ' 10 Non -Concurrent
12 Bottom Chord Dead 5 3 `
6.00 TOTAL Load 32 7.2
Duration Factor 1.25
Wind Speed 160mph
000 14.00 s" Top Chord C.B. Sheeting by builder.
12 — Bottom Chord C.B. Sheeting by builder.
'87 Highest Mean Height 15'-0
Building Type ENCLOSED
2' Building Category II:Non Restrictive
upset=1l4" heel 4 3/16" Exposure Category C
Barrier Island No
SQUARE CUT END Conforms to FBC 2010
2 x 4 Top Chord R.D.L.=Restrainin Dead Load C.B.=Continuous Bracing
WALL HEIGHT 9' Verify DESIGN CRITERIA shown above with the
END DETAIL: TYPICAL VAULT building department and your engineer.
Design Criteria is the responsibility of the -
Building Designer and/or Engineer of Record.
T REVIEWED Chambers Truss Inca Drawing Name: 71772
/API'Rl) o Scale: 1 /4 = 1'
COMPLIANCE H 38 total trusses, 11 different trusses.
AWW"TURAL DRAWMvtis MI 4: RLC ACAD: RLC Reviewed By:
Date: 03/21 /14
FOR
Z ART KRIEGER CONSTRUCTION
DESCRIPTION:
WALPOLE GARAGE
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
11 TRUSS DRAWINGS ARE ATTACHE® To LAYOUT _ 71772frail
FILr.
Lumber desigh Values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
MiTek'
RE: 71772 - Walpole Garage
Site Information:
Customer Info: Art Krieger Construction
Lot/Block:
Address: unknown
City: St. Lucie County
Project Name: Walpole Garage Model:
Subdivision:
State: FL
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: ASCE 7-10 [All Heigh][I Wind Speed: 160 mph
Roof Load: 32.0 psf Floor Load: N/A psf
This package includes 11 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
I Seal#
Truss Name
I Date
1
IT6219697
JA1
3/21/014
12
I T6219698
J A
1 3/21 /014
13
IT6219699
113
1 3/21/014
4
IT6219700
I GEAi
3/21/014
5
1 T6219701
I GEA
3/21/014
16
I T6219702
I GEB
1 3/21/014
17
I T6219703
I V4
1 3/21 /014
18
I T6219704
I V8
1 3/21 /014
19
I T6219705
I V 12
1 3/21 /014
110
I T6219706
I V16
1 3/21/014
11
I T6219707
I V20
1 3/21 /014
The truss drawing(s) referenced above have been prepared by MiTek
Industries, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Albani, Thomas
My license renewal date for the state of Florida is February 28, 2015.
IMPORTANT NOTE: Truss Engineer's responsibility is solely ,for
design of individual trusses based upon design parameters shown
on referenced truss drawings. Parameters have not been verified
as appropriate for any use. Any location identification specified is
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer,
per ANSI/TPI-1, Chapter 2.
A„ A
•G E N S 'eI
39 0
0'.• S TAT E OF : �44/
NA-
FL Cert. 6634
March 21,2014
Alban, Thomas 1 of 1
Job
Truss
Truss Type r
y
ly
Walpole Garage
T6219697
71772
Al
COMMON
11
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri Mar 21 15:22:26 2014 Page 1
ID:AOC7XCMOgKF_KpnBzSK9G6yf5j F-2r21 EYoevUyb7Y_oTj F6QTyEXfyb22wA1 XVp76zYhGB
-2-0-0 , 6.5-15 13-8-0 20-10-1 27-4-0
2-0-0 6.5-15 7-2-1 7-2-1 6-5-15
Scale = 1:50.5
4x5 =
8 1?
IT
0
SA= 3X4 = 3X6 = 3X4 = 3X4
3x4 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FBC2010/TP12007
CSI
TC 0.29
BC 0.36
WB 0.72
(Matrix-M)
DEFL in
Vert(LL) -0.22
Vert(TL) -0.33
Horz(TL) 0.03
(loc) 1/defi Ud
9-11 >999 360
9-11 >911 240
8 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 134 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-10-11 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 8=719/0-8-0 (min. 0-1-8), 12=965/0-8-0 (min. 0-1-8)
Max Horz 12=318(LC 7)
Max Uplift8=-470(LC 8), 12= 844(LC 8)
Max Grav8=836(LC 14), 12=1071(LC 2)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3= 660/477, 3-4=-446/370, 4-5=-432/401, 5-6=-979/603, 6-7= 12137757,
7-8=-1432/819
BOT CHORD 2-12= 5351799, 11-12=-337/1005, 11-19=-227/770, 10-19= 2271770, 10-20= 227/770,
9-20— 227/770, 8-9=-662/1211
WEBS 6-11=-91/292, 6-9=-294/609, 7-9=-447/388, 5-12= 1392/1060
NOTES
1) Unbalanced roof live loads have been considered for this design. 41/11111/
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. II;,,
Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60 `��� �P`S. . ,.14e
3) The solid section of the plate is required to be placed over the splice line at joint(s)10. �%��� , • • . G E N S _
4) Plate(s) at joint(s) 10 checked fora plus or minus 5 degree rotation about its center. ; A� V
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will * O 39389
fit between the bottom chord and any other members, with BCDL = 5.Opsf. /
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 470 lb uplift at joint 8 and 844 lb uplift at
joint 12.
8) "Semi -rigid phchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. r ATE (V
LOAD CASE(S) Standard R
is
&/0 N
����/1111114444�
FL Cert. 6634
March 21,2014
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M TEKREFERENCE PAGEMI-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an individual building component.
Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction isthe responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
A
eka
M i IT
fabrication, quality control, storage, dellvery, erection and tracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
If Sauthem Pine (SP) lumber is specified, the design values are those effective 06/01/2013 by ALSC
Tampa, FL 33610-4115
Job
Truss
cuss ype r
Qty
y
Walpole Garage
T6219698
71772
A
COMMON
12
1
Job Reference (optional)
.er. rru. mc., ron riarce n. a4aoz ID:AOC7XCMOgKF—KpnBzSK9G6yf5j F-aeUfl DnD9AgIOOPcv7jtuGP3q FcMJbglotmGTfzYhGC
-2.0-0 6.5.15 13.8-0 20-10.1 27-4-0 29.4-0
2 0.0 6-5-15 7-2-1 7-2-1 6.5-15 2-0-0
Scale = 1:51.9
4x5 =
3x4 = "^-' — aao — axv — 3x4
3x4 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FBC2010frP12007
CSI
TO 0.29
BC 0.36
WB 0.72
(Matrix-M)
DEFL in (loc) Udefl Ud
Vert(LL) -0.22 11-13 >999 360
Vert(rL) -0.33 11-13 >908 240
Horz(TL) 0.03 9 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 138 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 14=964/0-8-0 (min. 0-1-8), 9=811/0-8-0 (min. 0-1-8)
Max Harz 14=-332(LC 6)
Max Upliftl4=-842(LC 8), 9— 624(LC 8)
Max Grav 14=1070(LC 2), 9=949(LC 14)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-666/477, 3-4= 444/370, 4-5=-430/401, 5-6= 978/601, 6-7= 1206/746,
7-8=-1320/807, 8-9= 1424/795
BOT CHORD 2-14=-535/807, 13-14=-251/1027, 13-21=-1401791, 12-21=-1401791,
12-22= 140/791,
11-22=-1401791, 9-11=-542/1192
WEBS 6-13— 92/292, 6-11=-284/602, 7-11= 443/382, 5-14— 1392/1055
NOTES
1) Unbalanced roof live loads have been considered for this design. ►111111
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. ll; ♦♦♦a�,PS A q �
Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed ;Lumber DOL=1.60 plate grip DOL=1.60 ♦ �e ♦�
3) The solid section of the plate is required to be placed over the splice line at joint(s) 12. ♦�♦ 0 •' Ci E.
4) Plate(s) at joint(s) 12 checked for a plus or minus 5 degree rotation about its center. ��,`�: • \,� SF •'.9�%i �i
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide wild O 3938..
;.
fit between the bottom chord and any other members, with BCDL = 5.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 842 lb uplift at joint 14 and 624 lb uplift at +
joint 9. =
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ATE
0 •• <C/
LOAD CASE(S) Standard ,'ice . •c� O R 1 O Q ;.• ��`♦♦
.,'f;s1 /0 N AL ��C��♦♦
111111111
FL Cert. 6634
March 21,2014
0 WARMNG - Verify design p...ters and READ NOTES ONTEIS AND INCLUDED MITEKREPERENCE PAGE MTI-7473 BEFORE USE.
v
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and Is for an individual building component.
Applicability of design parameters and proper Incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responabllity, of the
erector. Additional bracing the is the the
MiTek•
permanent of overall structure responsibility of building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312 Alexandria, VA 22314.
If Sauthem Pine (SP) lumber is specified, the design values are these effective 06101/2013 by ALSO
6904 Parke East Blvd.
Tampa, FL 33610-4I15
o
Truss
Truss Type
Oty
Ply
Walpole Garage
T6219699
71772
B
COMMON
7
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MI I eK Inaustnes, Inc. Fn Mar 21 15:22:28 2014 Page 1
ID:A0C7XCM0gKF Kpn8zSK9G6yf51F-_DAofEgvR5CJFr8Ba7HaVulcrTgWW5zTUr_w4__XYhG9
-2-0-0 5-6-12 10-6-0 15-5.4 21-0-0 230 0
2-0-0 5 6 12 4-11-4 4-11-4 5.6-12 2 0 0
4x4 =
Scale = 1:41.5
Iv
0
3x4 = 3x4 =
3x4 =
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in
(loc)
Udefl
Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.18
Vert(LL)
0.06
8-10
>999
360
MT20 244/190
TCDL 7.0
Lumber Increase
1.25
BC 0.20
Vert(rL)
-0.09
8-10
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.17
HOrz(rL)
0.03
6
n/a
n/a
BCDL 5.0
Code FBC2010/TP12007
(Matrix-M)
Weight: 100 lb FT = 0%
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS (lb/size) 2=658/0-8-0 (min. 0-1-8), 6=658/0-8-0 (min. 0-1-8)
Max Horz2=265(LC 7)
Max Upli t2= 564(LC 8), 6=-564(LC 8)
Max Grav2=784(LC 2), 6=784(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1112/671, 3-4=-973/668, 4-5=-973/668, 5-6— 1112/671
BOT CHORD 2-10=-426/1033, 9-10=-166/655, 8-9=-166/655, 6-8= 426/942
WEBS 4-8= 224/401, 5-8= 318/272, 4-10=-224/400, 3-10=-318/272
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. ,1111111 I I llo��
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ♦♦a� PS A • ,q ����
fit between the bottom chord and any other members. ♦ �1 • , , .
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 564 lb uplift at joint 2 and 564 lb uplift at `♦�%_ �o • • • C E N S •'
joint 6. ♦ �� :: �, !%i i
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. : • r��l
LOAD CASE(S) Standard
• 0 39380 ,
.,
.• STATE
/1111111/
FL Cert. 6634
March 21,2014
WARNING - Verlfg design paramedem and READ NOTES ON72YIS AND INCLUDED WIFKREFERENCE PAGE blf1-7473 BEFORE USE.
SAW[
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
on
is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the
erector. Additional bracing the Is the the building designer.
iUliTek`
permanent of overall structure responsibility of For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/rPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Solely Information available from Taus Plate Institute, 781 N. Lee Sheet, Suite 312 Alexandria. VA 22314.
ifsouthem Pine (SP) lumber is specified, the design values are thase effective 06/01/2013 by ALSC
Tampa, FL 33610-4115
Job
Truss
Truss Type .
Oty
Ply
Walpole Garage
T6219700
71772
GEA1
GABLE
1
1
Job Reference (optional)
unambers I russ Inc., t-on rIeree H. 34982
2-0-0 ' 13-8-0
7.350 s Sep 27 2012 Mi-rek Industries, Inc. Fri Mar 21 15:22:32 2014 Page 1
ID:A0C7XCM0gKF Kpn8zSK9G6yf5jF-t7OIVctPVKjlkTRypzLWgkCHU431Swu3PTy7DIzYhG5
4x4 =
3x6 =
Scale = 1:50.5
A =
Iv
0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr NO
Code FBC2010/rP12007
CSI
TC 0.20
BC 0.08
WB 0.11
(Matrix)
DEFL in (loc) I/defl Ud
Vert(LL) -0.00 1 n/r 120
Vert(rL) -0.02 1 n/r 90
Horz(TL) 0.00 17 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 156 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
REACTIONS All bearings 27-4-0.
(lb) - Max Horz2=319(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 17, 25, 29, 31 except 2=-268(LC 8), 26=-100(LC 8), 27=-108(LC 8),
28=-107(LC 8), 30=-142(LC 8), 23=-100(LC 8), 22=-109(LC 8), 21=-104(LC 8), 20— 106(LC 8), 19=-105(LC 8),
18=-11O(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 17, 2, 25, 26, 27, 28,
29, 30, 31, 23, 22, 21, 20, 19, 18
FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL--3.Opsf; h=15ft; B=40ft; L=48ft; eave=2ft; Cat.
II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to Wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVrPI 1.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
1rfI�
,�� p,S A. q '
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
`% Ci E N Si •. .�
,rQ �. F •'. �%i i
~- �••, r%j
8) • This truss has been designed for alive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
% -
O 3938
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 25, 29, 31 except *
Qt=lb)2=268,26=100,27=108,28=107,30=142,23=100,22=109,21=104,20=106,19=105,18=110.
10) "Semi -rigid pltchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
l
=��'�•`.ATE
LOAD CASE(S) Standard
OR
/ONAI
FL Cert. 6634
March 21,2014
© WARNING - Verify design p...ters and READ NOTES ON THIS AND INCLUDED MTMK REFERENCE PAGE M17473 BEFORE OSE.
Design valid for use only with MTek connectors. lhls design Is based only upon parameters shown, and is for an individual building component.
�e
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the
erector. Additional bracing the Is the
MiTek'
permanent of overall structure responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/IPII Quality Criteria, DSB-89 and BCSI Building Component
SafeifSouthemPinef5P)lumben available rrsssppecifie th desi N.Lee Street,Suite a Alexandria, %A22314.
gnvaluesarethaseeffective0b 01%20136yAL5C
6904 Parke East Blvd.
Tampa,FL33610-4115
Job
Truss
Truss Type
Oty
Ply
Walpole Garage
T6219701
71772
GEA
GABLE
1
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fn Mar 21 15:22:30 2014 Page 1
ID:AOC7XCMOgKF_KpnBzSK9G6yf5jF-wclY4wr9ziT1 U91aiYJ2bJ6x_GNk_??my9T18tzYhG7
-2-0-0 , 13-8-0 27-4-0 29-4 0 ,
2-0-0 13-8-0 13-8-0 2 0 0
4x4 =
Scale = 1:51.9
3Io
33 04 OI Ju du 40 G/ eo eq ell LL Y1 Lu
3x6 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 5.0
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
OTHERS 2x4 SP No.3
SPACING
2-0-0
CSI
Plates Increase
1.25
TC 0.20
Lumber Increase
1.25
BC 0.09
Rep Stress Incr
NO
WB 0.13
Code FBC2010ITP12007
(Matrix)
DEFL in (loc) Vdefl Ud
Vert(LL) -0.03 19 n/r 120
Vert(rL) -0.04 19 n/r 90
Horz(TL) 0.01 18 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 159 lb FT = 0%
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
REACTIONS All bearings 27-4-0.
(lb) - Max Horz2=-332(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 27, 28, 31, 33, 25, 22,20 except 2=-283(LC 8), 29=-109(LC 8),
30= 107(LC 8), 32= 142(LC 8), 24= 109(LC 8), 23=-107(LC 8), 21=-142(LC 8), 18= 283(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 2, 27, 28, 29, 30, 31, 32, 33, 25, 24, 23, 22, 21, 20, 18
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 9-10— 95/277, 10-11=-81/277
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=2ft; Cat. 11;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for Wind loads in the plane of the truss only. For studs exposed to Wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVrPI 1. 11111111111/1,
4) All plates are 2x3 MT20 unless otherwise indicated. `,`%% PS A /��e
5) Gable requires continuous bottom chord bearing. ``� 0\V` • •.. 4 I�
6) Gable studs spaced at 2-0-0 oc. ♦ E N
7) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. �� A`X • �,� Ci SE 9 �i
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will Z • �`�I
fit between the bottom chord and any other members. • • O 3938
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 31, 33, 25,'
20 except (jt=1b) 2=283, 29=109, 30=107, 32=142, 24=109, 23=107, 21=142, 18=283.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard O .� 5 AT
�� s •,.
FL Cert. 6634
March 21,2014
Q WARNING - Verify design parmneters and READ NOTES ON THIS AND INCLUDED MITEKREFERENCE PAGE MI-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the resporebllity of the
Additional bracing the
MiTek'
erector. permanent of overall structure Is the responsibility of the building designer. For general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI/1PI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 22314.
it 5outhem Pine (SP) lumber is specked, the design values are these effective 06/01/2013 by ALSC
Tampa, FL 33610-4i 15
m p
Job
Truss
Truss Type
cny
Ply
Walpole Garage
T6219702
71772
GEB
GABLE
1
1
Job Reference (optional)
unflmDBrs , russ,nc., r-on r,erce N. 34etlz /.35u s Sep z! vuiz MII eK maustnes, inc.rn Mar zl 1xzz:342o14 rage 1
ID:AOC7XCMOgKF KpnBzSK9G6yf5jF-pNX3wlug1xzTzmbLxOO_19HcztlowrDMsnREHezYhG3
-2-0-0 10-6-0 21-0-0 23-0-0
2-0-0 10-6-0 10-6-0 2-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 5.0
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
OTHERS 2x4 SP No.3
4x4 =
US =
SPACING
2-0-0
CSI
DEFL
in
(lox)
Vdefl
Ud
Plates Increase
1.25
TC 0.20
Vert(LL)
-0.03
13
n/r
120
Lumber Increase
1.25
BC 0.08
Vert(rL)
-0.05
13
n/r
90
Rep Stress Incr
NO
WB 0.06
Horz(TL)
0.00
12
n/a
n/a
Code FBC2010/TP12007
(Matrix)
Scale = 1:41.5
PLATES GRIP
MT20 244/190
Weight: 111 lb FT = 0%
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc Purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 21-0-0.
(lb) - Max Horz2= 265(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 19, 21, 23, 16, 14 except 2=-274(LC 8), 20— 106(LC 8), 22=-139(LC
8), 18=-106(LC 8), 15=-139(LC 8), 12= 274(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 2, 19, 20, 21, 22, 23, 18, 16, 15, 14, 12
FORCES (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Iv
0
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 8=40ft; L=48ft; eave=2ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVrPI 1.
4) All plates are 2x3 MT20 unless otherwise indicated.
�11111IIIl/y1
5) Gable requires continuous bottom chord bearing. �i�P�J A qi,,f
6) Gable studs spaced at 2-0-0 oc. • • e �j
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �%% O •' C EN
8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ��,`�: • �.� S� q�i �i
fit between the bottom chord and any other members. 4 - J` - • r i�
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 21, 23, 16, 14 : 0 3938
except @=1b) 2=274, 20=106, 22=139, 18=106, 15=139, 12=274. * • '
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
�- ATE
i1'�sslo
FL Cert. 6634
March 21,2014
Q WARNING - V.,, fg design parameters and READ NOTES ONTNIS AND INCLUDED NITEKREPERENCE PAGE bill-7473 BEFORE USE.
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and is for an individual building component.
(-
Applicability of design parameters and proper incorporation of component Is responsibility of building designer - not fruss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
M iTek°
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 781 N. Lee Street Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
1f Southern Pine (SP) lumber is specified, the design values are those effective 06/01/2013 by ALSO
Tampa, FL 33610-4115
Job
Truss
Truss Type
Qty
Ply
Walpole Garage
T6219703
71772
V4
VALLEY
1
1
Jab Reference (optional
r.SSV s bep Z/ 'ZVlZ MI I eK maustnes, Inc. rn Mar zi 1 b:ZZ:bH ZU14 vage 1
ID:AOC7XCMOgKF_Kpn8zSK9G6yf5jF-h8naRxA5ATuSOv6AESwv7SLEV68sf4ynPPSQPzYhG7
4-0-0
2-0.0
3x6 =
2
3x4 5-
3x4
Scale = 1:7.8
Plate Offsets (X,Y): f2:0-3-0,Edgel
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.06
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber Increase 1.25
BC 0.12
Vert(fL) n/a n/a 999
BCLL 0.0
Rep Stress [nor YES
WB 0.00
Horz(TL) 0.00 3 n/a n/a
BCDL 5.0
Code FBC2010/rP12007
(Matrix)
Weight: 11 lb FT = 0%
LUMBER
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS (lb/size) 1=75/4-0-0 (min. 0-1-8), 3=75/4-0-0 (min. 0-1-8)
Max Horz 1=-29(LC 6)
Max Upliftl=-54(LC 8), 3=-54(LC 8)
Max Grav 1=88(LC 2), 3=88(LC 2)
FORCES (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
BRACING
TOP CHORD Structural wood sheathing directly applied or4-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=481t; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,j111111 I I1 Al��
fit between the bottom chord and any other members. �� /'*
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 3. `��` �P`S. A', 44e '
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. �� • • C E S' • •, '9
LOAD CASE(S) Standard
FL Cert. 6634
March 21,2014
Q WARMNG - Verify design parameters and READ NOTES ON 9TIIS AND INCLUDED MI7EKREPERENCE PAGE N7fL-7473 BEFORE USE.
Design valid for use only with MTek connectors. this design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of bulding designer - not buss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction Is the responsibility of the
erector. Additional bracing of the is the the building
M!Tek'
permanent overall structure responsibility of designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSlfrPll Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Irutihrte, 781 N. Lee Street, Suite 312 Alexandria VA 22314.
If southern Pine (SP) lumber is specified, the design values are t hase effective 06/01/2013 by ALSO
6904 Parke East Blvd.
Tam a
p , FL 33610-4115
Job
Truss
Truss Type
Qty
Ply
Walpole Garage
T6219704
71772
V8
VALLEY
1
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fill Mar 21 15:22:39 2014 Page 1
ID:AOC7XCMOgKF_KpnBzSK9G6yf5j F-ALLyz?yosTbl3YU Ijx_9SD_SCuRvb6m5039?zrzYhG_
4-0.0 8-0-0
4-0-0 4-D-0
3x4
2x3 II
4x4 =
3x4
Scale = 1:15.1
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.30
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber Increase 1.25
BC 0.15
Vert(rL) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.04
Horz(TL) 0.00
3 n/a n/a
BCDL 5.0
Code FBC2010frP12007
(Matrix)
Weight: 25 lb FT = 0%
LUMBER
BRACING
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size) 1=94/8-0-0 (min. 0-1-8), 3=94/8-0-0 (min. 0-1-8), 4=177/8-0-0 (min. 0-1-8)
Max Harz 1=-71(LC 6)
Max Upliftl=-85(LC 8), 3— 85(LC 8), 4= 96(LC 8)
Max Grav 1=113(LC 13), 3=123(LC 14), 4=208(LC 2)
FORCES (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. II
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
members.fit between the bottom chord and any other 6) Provide mechan cal connection (by thews) of trussto bearing plate capable of withstanding 100 Ib uplift at joint(s)1, 3, 4. ,`%�P J� A! f q
7) "Semi -rigid pitchbreaks including heels" Member end f idly model was used in the analysis and design of this truss. ,��� �\�'`. • G ENS'-.
30 9380
:= 5 ATE10
LOAD CASE(S) Standard
FL Cert. 6634
March 21,2014
0 WARNING - Verify design paz eters and READ NOTES ON THIS AAm INCLUDED i117TEKREFERENCE PAGE B4f1-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper Incorporation of component Is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the
erector. Additional bracing the is the the building designer. For
MiTek`
permanent of overall structure responsiblity of general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East BNd.
Safety Information available from Truss Plate Institute, 781 N. Lee Street,
eet, Suite 312, Alexandria, VA 22314.
IfSauthern ine(5P)lumber isspecifed, the design values are t�hoseeffective06101/2019byALSC
pa '
TFL 33610-4i 15
am
Job
Truss
Truss Type
city
Ply
Walpole Garage
T6219705
71772
V12
VALLEY
t
1
Job Reference (optional)
unamDe,s I russ Inc., ton Pierce m. 34932 7.3bo s 5ep 27 2012 MI l eK Incustnes, Inc. I-n Mar zl 1 b:z2:34 Zu14 Pagel
ID:AOC7XCMOgKF_Kpn8zSK9G6yf5j F-pNX3wlug 1 xzTzm bLxOOJgH WxthMwrSMsnREHezYhG3
6-0-0 12.0-0
6-0-0 6-0-0
3x4
4x5 =
2x3 11
3x4
Scale = 1:21.2
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.59
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 7.0
Lumber Increase
1.25
BC 0.36
Vert(rL)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
W B 0.06
Horz(TL)
0.00 3
n/a
n/a
BCDL 5.0
Code FBC2010ITP12007
(Matrix)
Weight: 39 lb FT = 0%
LUMBER
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING
TOP CHORD
BOT CHORD
REACTIONS (lb/size) 1=133/12-0-0 (min. 0-1-8), 3=133/12-0-0 (min. 0-1-8), 4=315/12-0-0 (min. 0-1-8)
Max Harz 1=-114(LC 6)
Max Upliftl=-112(LC 8), 3=-112(LC 8), 4=-198(LC 8)
Max Grav 1=162(LC 13), 3=178(LC 14), 4=371(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-280/208
Structural wood sheathing directly applied or 6-0-0 oc pudins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuh=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) , This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 1111111 p0l
fit between the bottom chord and any other members.
6 Provide mechanical connection
nnection ���1Pcj A.
(by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) 1=112, `� � • •,,.. �e '
3=112, 4=198. ♦�% • • • \ G E N S' • • "9 o
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ♦ ,`�: \. F •'. !li s
LOAD CASE(S) Standard
N 30 9380
i l--
Mir
:TE •
i-0 s, N A` is ;%%%.iil. ,
111111111
FL Cert. 6634
March 21,2014
0 WARNING - Verify design pa caneters and RE&D NOTES ON THIS At1m INCLUDED NB7EKREPERENCE PAGE N f1-7473 BEPORE USE.
Design valid for use only with MTek connectors. This design is based only upon parameters shown, and !star an individual building component.
�•
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not buss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibiliify of the
erector. Additional bracing the is the the building
MiTek•
permanent of overall structure responsibility of designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Taus Plate Institute, 781 N. Lee Sheet, Suite 312, Alexandria, VA 22314.
if Southern Pine (SP) lumber is specked, the design values are those effective 06/01/2013 by ALSO
6904 Parke East Bkd.
Tampa, FL 33610-4115
Job
Truss
Truss Type
Qty
Ply
Walpole Garage
T6219706
71772
V16
VALLEY
1
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fn Mar 21 15:22:36 2014 Page 1
ID:A0C7XCM0gKF_Kpn8zSK9 G6yf 5j F-Imf pLzwwZYDBC4lj2pQSgaMx9hRoOkRf K5wLMWzYhG 1
8-0-0 16-0-0
8-0-0 8-0.0
3x4-:--
FIRM]
4x4 =
2x3 11
16.0.0
ME
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Well
Ud
TCLL 20.0
Plates Increase
1.25
TC 0.28
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber Increase
1.25
BC 0.04
Vert(rL)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.07
Horz(TL)
0.00 5
n/a
n/a
BCDL 5.0
Code FBC2010/TPI2007
(Matrix)
LUMBER
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP M 30
OTHERS 2x4 SP No.3
BRACING
TOP CHORD
BOT CHORD
REACTIONS All bearings 16-0-0.
(lb) - Max Horz1=-156(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-231(LC 8), 6=-231(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=335(LC 13), 6=335(LC 14)
FORCES (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8= 287/248, 4-6= 287/248
Scale = 1:28.1
3x4
PLATES GRIP
MT20 244/190
Weight: 58 lb FT = O%
Structural wood sheathing directly applied or 6-0-0 oc pudins
Rigid ceiling directly applied or 10-0-0 oc bracing.
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. 11;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) fitTbetwhis ensth bottom chord and anyhas been designed for a lother me bersP ve load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ,```>>PS A T P q
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except at=lb) `� \V` ...... �e Imo,
8=231, 6=231. ��` • • • G E N 5' • • •9
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ,`�.' �.
LOAD CASE(S) Standard
0 39380� ter,
•
A= x
E :• �U
Off. �U
�';sse0 N M_
FL Cert. 6634
March 21,2014
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MII REFERENCE PAGE b9fl-7473 BEFORE USE.
Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
ffm
is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the
Additional bracing the is the building
MiTek'
erector. permanent of overall structure responsibility of the designer. For general guidance regarding
fabrication quality control, storage, delivery, erection and bracing, consult ANSlfrPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East BNd.
Safety Information available from Truss Plate Institute, 781 N. Lee Sheet, Suite 312, Alexandria, VA 22314.
If Southern Pine (SP) lumber is specified, the design values are those effective 06/01/2013 by ALSC
Tampa, FL 33610-4115
Job
Truss
Truss Type
Qty
Ply
Walpole Garage
T6219707
71772
V20
GABLE
1
1
Job Reference (optional)
Chambers Truss Inc., Fort Pierce FI. 34982 7.350 s Sep 27 2012 MiTek Industries, Inc. Fri Mar 21 15:22:37 2014 Page 1
ID:A0C7XCM0gKF_Kpn8zSK9 G6yf5j F-DyDBYJxYKsL2q EKwcWxhNovi C5iO7ByoZlguuzzYhGO
10-0-0 20-0-0
laao 10-ao
05 =
3x4 - o n 7 A 3x4
2x3 II
2x3 11
3x6 =
Scale = 1:35.1
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 5.0
SPACING 2-0-0
Plates Increase 1.25
Lumber Increase 1.25
Rep Stress Incr YES
Code FBC2010frP12007
CSI
TC 0.59
BC 0.34
WB 0.12
(Matrix)
DEFL in
Vert(LL) n/a
Vert(rL) n/a
Horz(TL) 0.00
(loc) Vdefl Ud
n/a 999
n/a 999
5 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 72 lb FT = 0%
LUMBER BRACING
TOP CHORD 2x4 SP No.3 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
MTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance With Stabilizer
Installation guide.
REACTIONS All bearings 20-0-0.
(lb) - Max Harz 1=198(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8 except 9= 303(LC 8), 6=-303(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=337(LC 2), 9=440(LC 13), 6=440(LC 14)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-8=-274/136, 2-9=-388/334, 4-6= 388/334
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=40ft; L=48ft; eave=6ft; Cat. 11;
Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will 1,111111111 /1�
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at
�O`% S A Ili
joint(s) 1, 5, 8 except Gt=lb) �P,S , A. 11
`�% ,
,
9=30316=303. `-% , •' G E N S -y 0�
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.�: �. F�'.•!%?_
LOAD CASE(S) Standard
O 380
• *
VIr Z
:O.• ATE .<v:
/o N A1- E
%;�`>`�
41111111110
FL Cert. 6634
March 21,2014
Q WARNING - Verify design pa eters and REED NOTES ONTTIIS AAm INCLUDED MITEKREPERENCE PAGE MU-7473 EEPORE USE.
Design valid for use only with M7ek connectors. This design is based only upon parameters shown, and is for an individual bulding component.
Applicability of design parameters and proper Incorporation of component Is responsibility of building designer -not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stablity during construction is the responvbillity of the
erector. Additional bracing the is the the building designer.
MiTek`
permanent of overall structure responsibility of For general guidance regarding
fabrication, quality control, storage, delivery, erection and tracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
SIM Information available from Truss Plate Institute, 781 N. Lee Street, Suite 312, Alexandria VA 22314.
If tiouthem Pine j5P) lumber is specified, the design values are these effective OS/01/2013 by ALSC
Tampa, FL 3361 a4115
p
Symbols Numbering System ® General Safety Notes
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
offsets are indicated.
Dimensions.are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-'/td'
For 4 x 2 orientation, locate
plates 0-1/0 from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
el by text in the bracing section of the
output. Use T or I bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2
TOP CHORDS
5_
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Southern Pine lumber designations are as follows:
SYP represents values as published
by AWC in the 2005/2012 NDS
SP represents ALSC approved/new values
with effective date of June 1, 2013
© 2012 MiTek® All Rights Reserved
111111111011111110
MiTek Engineering Reference Sheet: Mll-7473 rev. 02/26/2013
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, Individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered,
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties,
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane atjoint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ff. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.