Evaluation Report M3571012.10-R11
Boral Roofing^f FL14317-RIO
7575 Irvine Center Drive,Suite 100 Date of Issuance:12/7-1/2010
Irvine,CA.92618 Revision 11:10/12/2018
(602)269-2298
SCOPE:
ule 63G20-3 and the applicable rules and regulations governing the use o
This Evaluation Report is issued under R
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the Su'Edition(2017)Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreementto notify Robert Nieminen,P.E.of any changes to the
product(s),the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPEMON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This.Evaluation Report consists of pages 1 through 8.
Prepared by: d�.� ="
Robert J.M.Nierr+ir+en P.E. ThefacsimilesealaPPearingwasauthorizedbyRobert
Nieminen,P.E.on 10/12/201&This does not serve as an
Florida Registration No.59156,Florida DCA ANE1983
electronically signed document.
CEFMFiCATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
elf—
ROOFING COMPONENT EVALUATION:
Product Category: Roofing �- -
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the Wh Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations
/Conditions of Use set forth herein.
7 „ 7 v 'ter
c.:✓�,� �_ s �} 7 3�w rr 35.^�.._. t C�a rG4 �:. x �c�'4 '!r:
1504.3.1 Wind Uplift UL 1897 201Z
1507.1.1,T1507,1.1, Physical Properties ASTM D1970 2015
1507-2.9.2
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
ERD(TST 6049) Physigl Properties M36790.07.11 09/30/2011
ERD(TST 6049) Physical Properties 840380.08.12 08/28/2012
ERD(TST 6049) Tensile Adhesion/LTA C41420.09.12-2 09/11/2012
ERD(TST 6049) Adhesion 841940.09.12 09/13/2012
ERD(TST 6049) Tensile Adhesion/LTA B47390.07.14-1 07/31/2014
ERD(TST 6049) Tensile Adhesion/LTA B41390.09.14 09/04/2014
OC(PDM1838) Physical Properties Equivalency statement 11/02/2017
PRI(TST5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI(TST5878) ASTM D1970 NEI-029-02 01:REV 12/03/2010
PRI(TST S878) Tensile Adhesion/LTA NEI-046-02-0IREV 12/17/2010
PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011
PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013
PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI(TST 5878) Tensile Adhesion/LTA DAPF-002-02-02 03/08/2018
PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018
UL,LLC.(QUA 9625) Quality Assurance Service Confirmation Exp.08/21/2020
•��,�.` r -v a� 3-Ct� h5...,r+ti "et 3 °�. � � c N x; --_"'" __'.$"-+ .
4.1 Boral® TileSeal 50"T is a nominal 50-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.2 Boral° 'ileSeal' is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI 04-12.
4.3 Boras© MetalSeal"T is a nominal 60-mil thick, polyester-surfaced, self-adhering SBS modified bitumen roof
underlayment;meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSeal°is a nominal 55-mil thick,granular-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.5 Citadel°Plus is a nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,self-adhering SBS modified bitumen
roofing underlayment for use as a base-layer in multi-ply underlayment systems,meets ASTM D1970.
PIEN10 ETC,LLC Evaluation Report M35710.1210-R21
cemficate ofAuthonzndon a2455 a"rt c'4 E Ti 0 Al 120:7)ro'C i@'01"!-iti i;%E1111.L U47i 1,0M 1 a P
:3Fi-M-1 0
Boras Roof Underlayments;(602)269-2288 Revision 11:10/12/2018
Page 2 of 8
tlf'i {t+ ' .,.yxz-tr 2�.
~5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report;refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof
covers. Refer to the installation instructions for multi-ply underlayment options.
Asphalt Adhesive-set Wood Shakes
Underlayment Shingles Nail-On Tile Tile Metal &Shingles Slate
Boral Tile5eal 501 Yes No No Yes Yes Yes
Boral TileSeal"T Yes Yes Yes(See 5.5.1) Yes Yes Yes
-
Boral,MetalSeal"T Yes Yes Yes Yes Yes Yes
(See 5.5.1)
GatorSeal Yes No No No Yes Yes
5.5.1 "Adhesive-set Tile"is limited to use of following Approved file adhesives/underlayment combinations.
Adhesive Florida Product Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL14506 Boral TIleSealHT or Boras MetalSeal"T
DAP Foam Touch'n Seal StormBond 2 Two-Component FL21374 Boral TileSeal"T or Boral MetalSeal"T
Polyurethane Roof Tile Adhesive
Dow TILE BOND"Roof Tile Adhesive FL22525 Boral TileSealHT or Boral MetalSeal"T
iCP Adhesives PolyseV AH-160 FL6332 Boral TileSeai"T or Boral MetalSeal"s
ICP Adhesives Polyset°RTA-1 FL6276 Boral TlleSeal"T or Boral MetalSeal"T
s Refer to Trle Manufacturer's orAdhesive Manufacturer's Florida ProductApproval for Overturning Moment Resistance Performance.
NEN10 Z!C,LL% evaluation Report N135710.12.10-1111
Urtifl=eofAuthonzation#32455 6"'_DrnoK,,(2C3 )FSC�!0i';-ikl,-,7 VA. ,ON FL't3:.7-R_o
Boras Roof Underlayments,(602)269-2288 Revision 11:10/12/2019
Page 3 of 8
E II
5.6 Allowable Substrates: J
5.6.1 Direct-Bond to Deck:
Citadel Pius,Boral TileSeal 50",Boral TileSeal ,Boral MetalSeal"T or GatorSeal:
8 ;Plywood(unprimed or primed with ASTM D41 primer).
Boral TileSeal"T or Boral MetalSealw:
> OSB(unprimed or primed with ASTM D41 primer).
Note:Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the
overlying roof cover is adhesive-set tile roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus,Boral TileSeal 501,Boral TileSeal",Boral MetalSeal"T or GatorSeal:
a ASTM D226,Type If felt;Citadel Plus.
For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum
codified requirements. For installations under adhesive-set tile systems,base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate TvpeS:
Citadel Plus,Boral TileSeal 50",Boral TileSeal",Boral MetalSeal"T or GatorSeal:
ASTM D41 primed metal(e.g-,flashing metal,valley metal,etc.).
Boral TileSeal"T:
v Huber Zip Deck(unprimed or primed with ASTM D41 primer);Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive-set Tile Applications: FRSA/TRI April 2012(04-12)does
not address wind uplift resistance of all underlayment systems beneath adhesive-set the systems, where the
underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TIII April 2012(04-12)and are used in adhesive-set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer
to FRSA/TRI April 2012(04-12),Appendix:A,Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41 to the plywood deck
Base Ply: Citadel Plus,self-adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga,x 1%"ring shank nails through 32 ga.,15/8"diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 usf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeall,self-adhered and back-nailed within the selvedge-edge side laps
using 12 ga.x 11/0'ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
f!E?AO ET=,LLC Evacuation Report M35710.12.10-R11
CertijlcateofAuthortw9an#32455 6"En;T MDi4(7-0 ;F SC i+ION4—l�::-EVALUAOHI ''-_`='� '0
- - Borai Roof Underlayments;(602)269-2288 —_......._._.. Revision=-10/12/2018
Page 4 of 8
#3 Maximum Design Pressure=-202.5 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"Tor Boral MetalSeall,self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga.x IN"ring shank nails through 32 ga,1-5/8"diameter tin caps spaced 12-inch o.c.
44 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer; KARNAK#89 Sta Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TIleSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side laps
using 12 ga.x 1'/a"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-220.0 osf
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional)Citadel Plus,self-adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal",self-adhered
5.6.4.1 Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design
pressure requirements may not exceed-120 psf.
5-7 Exposure Limitations:
CatorSeal shall not be left exposed for longerthan 30-days after installation,priorto placement of final roof cover.
Borai TileSeal 50";Boral TileSeal"T or Boral MetalSeal"T shall not be left exposed for longer than 180-days after
installation,prior to placement of final roof cover.
Citadel Picas,for use as a base-layer in a multi-ply underlayment system,shall not be left exposed for longer than
b 80-a1ai/s after installation,prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations(FRSA/TRI April 2022(04-12)]:
When loading roof tiles on the underlayment in direct-deck file assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Udderlayment 'File Profile Staging Method Maidmun Slope
Boral TileSeal"T or Flat Max.10-tile stack 6:12
I Boral MetalSeal"' Lugged Max.10-tile stack 6:12
y.. ... a # ^kart
6.1 Boral Roof Underlay ments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Install self-adhering underlayment when ambient and surface temperatures are minimum 407 and rising.
1,4[iv40 UC,LLC Evaluation Report M35710.=0-R12
Certificate ofAuthorization#32455 5"ED1171OP.!f2017)FSC NiOi:;V:Z EVA LU yIDid FU0317-R-10
Boral Roof Underlayments;(602)269-2288 Revision 31.10/12/2018
Page 5 of 8
r+
F Z51 S
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"T,
Boral TileSeall or GatorSeal.
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by%-inch.Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails &tin tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the
black-selvedge area,minimum 2 inches(horizontal lap)and minimum 6"end(vertical)laps.
Install final underlayment layer atop Citadel Plus per 'direct-to-deck' instructions for Boral TileSeal 501, Boral
TileSeal';Boral MetalSeallrr or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226,Type 11 felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi-ply system.
Install optional Citadel Plus as a mid-ply in accordance with Boral Roofing published installation instructions and
pY g
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per'direct-to-deck' instructions for Boral TileSeal 50"T, Boral
TMSeall or GatorSeal.
Note:For adhesive-set tile systems,if there is a base ply or mid-ply of Citadel Plus In the system,the project design
pressure requirements may not exceed-120 psf.
6.5 Boral TileSeal 50HT:
6.5.1 Shallbe installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.2.3.for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50'on roof pitches less than 2.12.
6.5.3 Non-Tile Applications.Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by%-inch.Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c.for slopes below 7:12 and maximum 12-inch o.c.for slopes
7:12 and greater. Overlap successive courses the entire width of the black-selvedge area,minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NE A0 E4C,LLC Evaluation Report M35710.12.10-R11
CertifimieofAuthora&jon#32455 5"'ED31IOi--_(21)17)FBC NIGH-PI aZ EaVALURFIONc
Boral Roof Underlayments,(602)269-2298 Revision 11:10/1212018
Page 6 of 8
6.5.4 Non-Tile Applications,to Base Sheet:
Install ASTM D226,Type li felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
install Boral TileSeal 50"T in accordance over ASTM D226,Type it felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3,except end(vertical)laps,described below.
Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shalibe installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non-Tile applications.Direct to Deck:
Cut the membrane into manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,
extending over by/d-inch_Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails,nails&tin-tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c.for slopes below 7:12 and 12-inch o.c.for slopes 7:12 and greater.
Overlap successive courses the entire width of the black selvedge area,minimum 34nch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top surface,rolling the interface into place with a
weighted roller,or using the inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non-tile Applications,to Base Sheet:
Install ASTM D226,Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral:Roofing published installation instructions and Section 6.4.
Install GatorSeal overASTM D226,Type Ii felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end(vertical)laps,described below.
Apply SBS Mastic under all side(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the granular top surface,rolling the interface into place with a weighted roller.
6.7 Boral TileSeall or Boral MetalSeali{T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 2507.1.1 for
the type of prepared roof covering to be installed_
6.7.2 Do not use Boral TileSeai"T or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non-Tile Applications,Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow-to dry prior to installation. Cut the membrane into
manageable lengths,typically 10 to 12 ft.Align the membrane parallel to the roof edge,extending over by X-inch.
Fold the membrane away from the edge onto Itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck,pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails,nails&tin-tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black-selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
i+':Ei:.lO E i C,LAC Evaluation Report M35710M.10-R11
Ceniftrate ofAutharizaUan 932455 0 E€3f fiON(2017)FOC i ION-MVIM=ci'ALUATfOlt F U14317-F.?0
Boral Roof Underlayments,(602)269.2288 Revision 11:10/12/2018
Page 7 of 8
6.7.4 Non=Tile Applications to Base Sheet L
Install ASTM D226,Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeall or Boral MetalSeal'over ASTM D226,Type Ii felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3,except end(vertical)laps,described below.
Apply SBS Mastic under all end(vertical)laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface,rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/THI April 2012(04-12)Installation Manual and Table 1 herein,using the instructions
noted above as a guideline.
For mechanically fastened tie roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRi April 2012(04-12),Table 1.
For adhesive-set file app►ications,refer to Section 5.6.4 herein.
Note:For adhesive-set the systems,if there is a base ply or mid-ply of Citadel Plus in the system,the project design
Pressure requirements may not exceed-120 psf.
Refer to Section 5.8 fortile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"T
or Boral MetalSealHT with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
.. - ,_„_,_.ti _c..� ,x ram.... c -_"'tr, z_ pY`'§�p..-r-•:_—We f ;..::� " �v..fir _.�E., a. �- 4 . t :.
As required bythe Building OfFicial or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
UL,
END OF EVALUA I ION REPORT-
WEiv)D r-eC,LLC
Certilicate afAuthorroton#32455 5"!EDITION.)'-G_i} _ _ c ti Evaluation Report M35710. 30-R31
e
,n F 4377-ii0
Boral Roof Underleyments,(602)269-2298 Revision 1110/12/2018
Page 8 of 8
' ExM101t RESEARCH&DESIGN,LLC-
GeWfrcate of AatltortwdOn:.9503
353 CHRiS11AN STREET,UNIT#13
gg' _ E� , VM �� ® PHO
�,� 4NE!(243)52-9245
i l
CODECOMPLIANCE FAX:(203)262 9243
EIfAWATION REPORT ' COUT. NTY
Report E`+0240.0s.08-R4
East Coast Metals,111c. O C C FL5374•R4
2301 Test 8 Lane Date of Issuance:09103/2008
Hialeah,FL 33010 Revision 4:0311 712 01 5
SCOPE: ladons governing the use of
This Evaluation Report is issued under Rule 61G20-3 and th Ii � e 1
P.E.for
construction materials in the State of Florida-
Cade and documentation
ntatFlorida Building Code,Residential Volume. Th proobert lducts described
use of the product under the Florida g
herein have been evaluated for compliance with the Sth Edition(2014)Florida Building Code sections noted herein-
DEscRIPTION: East Coast Metals Channel Metals
d Quality Assurance Agency noted herein.
LABEUNG: Labeling shall be in accordance with the requirements the Accredite
CONTINUED COIYPUANCE: This Evaluation Report is valid unfit such time as the named product(5)
changes, the referenced
or the
Quality Assurance documentation changes,or provisionementto notify Robert N em enr P.E.if the od product chuct change. anges ce of this
Evaluation Report by the named client constitutes ag of this Evaluation Report
ERD re wires a complete review
referenced Quality Assurance documentation changes. Trinity q
relative to updated Code requirements with each Code Cycle. be displayed in
ADVER�samENT: The Evaluation Report number preceded by the words "Trinity ERD Evacuated" may
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
IDISPECn0KI: Uponj request,a copy of this entire Evaluation
Report
a the all be provided
vide Build a user
b .the manufacturer or its
distributors and shall be available for inspection atth J
This Evaluation Report consists of pages 1 through 7.
Prepared by:
_�: s
- _ .: _ •O'c: tii_3 snsassthoieEd Irr ac6en trtenc�+.
rayMASd4 !i d
• - aeef rmtse3+z u an cleecci='alft di�
.�. �iC:r Ps on®/E1i7a75. Leentmm�lted io the
Robert l.M_Nteininen,P %Fs •-••=�:c a „�L s .seaw +'sh-�
Florida RegbIradan No-59166,Ronda DCR ANE1983 _`;J1i,�,�,ni �- PmdutiaFGrlAdmhistrawtothenancdc'n:nc
CERTIFICATION OF INDEPEnDENCE: manufacturing or
2. Trinity(ERD does not have, nor does it Intend to acquire or will it acquire,a financial interest in any company
distributing products it evaluates. products itevaluates.
2. T rinityI ERD is not owned,operated or controlled by any company evaluates-
manufacturing or distributing p anufacturing or distributing products for
3. Robert Nieminen, P.E.does not have ear will acquire,a finandal interest in any company m
which the evaluation reports are being issued. approval process of the
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the app
product. i way,the Designer of Record for any
5. This is a building code evaluation. NeitherTrinitylERD nor Robert Nieminen,P.E_are,in any
project on which this Evaluation Report,or Previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose. Reviewed For
Code Compliance
Wayyi,&S7wnvvla kv
01/22/2019
07,f a r;-
I
i
t
j '� 2 b V L I
`dt
RoomvG GompaNsa EVAWAnant:
1. .SCOPE:
Produce Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement_ East Coast Metals Channel Metals,as produced by East Coast Metals,have demonstrated compliance
with the following sections of the Florida Building Code through testing In accordance with the following Standards. Compliance
Issubjectto the Installation Requirements and limitations/Conditions of Use set forth herein.
. 2. STANDARDS:
Section i PropertyStandard Year
1507.33 i Installation,non-HVHZ FRSA/Ml April 2012(04-12) 2012
1528.8.1 Installation,HVHZ RAS LT8,119-9-220 1995
1523.6S-2 2 Static Upfiftilesistance TAS101 1995
1711.21 Static Uplift Resistance 5BCC155TD 11 1997
i
3. REFERENCES:
Entity Examination Reference Date
ERD(.ST6049) Static Uplift Resistance E42730.08.3 08/23/2023
ERD 95 5049) Static Upliftilesisance EMPSC679512.14-1 02/27/20a
ERD UM049) Static Uplift Resistance ECNI-SC6795JZ14-2 02127/2015
RoridaTEC(rSi7393) TAS 101 Slo 528R 10/27/2010
PRI(rST5878) TAS 202 ECM-001-0Z-01 09/31/2001
PRI(TSTS878) TAS 101 ECM-003-02-01 06/23/2008
PRI i �87B) TAS 101 ECWI-004-02-01 06/13/2008
PRI(T 5T5878) TAS 101 ECM-005-OZ-02 06/13/2008
PRI i IS878) TAS 101 ECM-006-02-01 06113/2008
= i PRI 878) TAS 101 ECM-007-02-01 (16/23/2008
PRI(TSi5878) TAS 101 EUv1-0o8.02-01 06/13/2008
Florida Building fade AttachmentReQuirementr FRSA/1'RI A 812{04 0412012
Florida Building Code-HVHZ Attachmentilequrrements RAS ,219 and 12f1 1g95
East Coast Metals Metal Quality r Certifications Various
Architectural Testing(QUA1844) Quality Control Participation Letter - .12/31/20i8
4. PRoDUCr DEsaupnom
4.1 Hip & Ridge Channel Metal: Pre 4ormed metal c nnel
designed for use as a hip and ridge base to which ftiles
are banded in FSCApproved roof tile adhesive.
Hip&Ridge Channel Metal is available in 119 /8-inch{_
3/8-inch)length by 25,3,35,4,5,6 or7-inc L�3/8-)nch)
heights with I5-inch(_1/16-inch)deck-flan es.
I _
Exterior Research`and Design,I.I.C. anon Report E1024n.09.a8-R4
-^erilrmte OfAuthcrrmtran a9s03
Revision a:a3iii7
4-
ol114.s
Page of 7
� 1
TWN
J ERD
4.2 Trim Lock Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perfarated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119 3/$-inch L
3/8")length by 3,3.5,4,5 or 6-inch L 3/84nch)heights
with 1.5-inch L=1/16-inch)deck-flanges.
4.2 Trim Lock Plus Channel Metal:Pre-formed metal channel !
/ t
designed for use as a hip and ridge base to which roof tiles ,��F
Approved roof tile adhesive. Trim Lock
I bonded in FBC App ;�• ,
plus Channel Metal is characterized by its profiled and f. F
perforated upper horizontal flange designed to receive
jr` I 1
'and allow for interlock with the overlying file adhesive
and its perforated deck flanges,designed for installation f''=�/r l
'atop the roof underlayment via placement in FBC �� K
Approved roof tile adhesive, which flows-through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in]19 3/8-inch , t
(T 3/8")length by 3,3.5,4,5 or 64nch(±3/84nch)heights
with 1.54nch(±1/164nch)deck flanges. IV
4.4 East Coast Metals Channel Metals are fabricated ofthe following metals:
1 > Galvanized Steel- Min.0.019 g 0.002-inch,ASiTA A653(G-90),min.33 iC51.
,� 6aivatume Steel: Min.0.019±0.002 inch,ASTM A792,A735,min.35 K51.
v� Aluminum: Min.0.032±0.002 inch,ASTM B2U9,3003-H14,min.21 KSL
min.35 KSf.
> Stainless Steel: Miq.0.019±0.002-Inch,ASTM A240/A480,T3041
$. UmITATIONS: bert Nierninen, Way.the Designer of
This is a building code evaluation. s Evaluation
Trinity]Report,
nor rev previous versions thereofeis/was used for permitting or
Record for any project on which this Evaluation Repo or p
design guidance unless retained specifically far that purpose.
Evaluation Report E10240083.08¢R4
Exterior Research and Design,LLG Revision 4•03/1712015
[ertilirntEojAuthodratraa119503 page3 of7
TRIM
5.2 FOR HVHZIURiSDICrIONS:
5.2.1 For Hip &Ridge Channel Metal or Trim Lack Channel Metal, refer to FBC RAS M, Drawing 3.3, Detail 3;RAS 139,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal,refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 218,119 and
3. 0,and the data inTables lA and IS is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance(M,)or uplift resistance(F,),
as:determined in accordance with RAS 127,not greater than the following•values.
Referto the-die adhesive manufacturer's published installation instructions for adhesive paddy placement details.
>1 `INDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in its own,single
foam paddy; file head laps are not bonded. This method is limited to 2-part Ile adhesives. Allowable
performance data below for"INDEPENDENT"paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
>- `INTERDEPENDENT"paddy placement means each individual Ile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the the head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT'paddy placement already has a 4 to 1
margin of safety applied to ultimate performance-
TABLEIA:PEtFoRmANcsLiMcsanoris-HVHZ,INDErenmaurPAoDYPwmvmavr
(2 Th 1 MARGM GFSA;TVALREADYAPPLED}
Htp/Ridge Metal Adhesive Allowable Performance.
Design Metal Type Tile MomentPlacement Moment Based Uplift Based
Mt(ft Ilig F(Ibf)
Hip&Ridge galvanized day or 3M"'2-Component Foam Independent 127 169
Channel Metal concrete RoofTile AdhesiveAH160
Trim Lack galvanized,Galvalume°, day or 3M"'2-Component Foam Independent 171 159
aluminum orstainlesssteel concrete Roof ileAdhesiveAH-160
Trim Lack Plus galvanized,Galvalume", day or 3Mm 2-Component Foam independent 177 l6s
aluminum or stainless steel concrete RoofTde Adhesive AH-160
Thsuil.B:PFRWRMANtELimiTATlows-HVHZ,INiERDEPENDENTPAODYPLAamENr
[4T0 1 MARGRP DFSAFMYALREADYAPPBW)
Hip/Ridge Metal Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design Metal Type Type Placement
Mr(ft lbf) F'(Ibf)
Trim Lodr orTrim gaivani ed,GaivalumeO, day or 3M-2-Component Foam Interdependent 95 88
Lack Plus aluminum or stainless steel concrete RoofTile AdhesiveAH-160
Trim Lode galvanized,Galvalume°, day or 3M-RoofTile Adhesive Interdependent 99 94
stainless steel concrete RTA 1
Trim Loci aluminum dayor 3M"'Foam RoofTrle Interdependent 90 84
concrete Adhesive RTA-1
Trim Lock Plus galvanized,Galvalume°, day or 3M"'Foam RoofTile interdependent 90 84
aluminum or stainless steel concrete AdhesiveRTA-1
Trim Loch galvanized,Galvalume°or day or TILE BONDS'RoofTOe interdependent 123 117
stainiewsteel concrete Adhesive
day or THE BOND"RoofTile
Trim Lock aluminum concrete Adhesive interdependent 79 73
gaivanized,Galvalume', clay or' TILE BOND"RoofTile +
Trim Lock Plus i Interdependent aluminum or stainless steel concrete Adhesive I 79 73
galvanized,Gaivalume°or day or Touch'n Seal StarmBond
Trim Lock stainless steel concrete RoofTileAdhesive interdependent 146 139
Trim Lack Aluminum day or Touch'n Seal StormBond Interdependent 58 54
I Iconcrete RoofTile Adhesive
Trim Lock Pius galvanized,Galvalume°, day or Touch'n Seal StormBond Interdependent 58 54
aluminum or stainless steel concrete Roof Tile Adhesive
Exterior Research and Design,LLC. Evaluation Report E30240.08.08-R4
[erd&rte ofAudror&atfan N9503 FLS374-R4
Revision 4:03(17/2015
Page 4 of 7
I - -
•
. I
IHIN( ERD
5.3 FOR NON-HWUL)RLSDICTIDNS:
53.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal,refer to FRSA/TRi April 2012(04-12). For Trim Lock Plus
Channel Metal,refer to the installation instructions herein
53-2 For non-HVHZ,installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation insizuctionsfor adhesive paddy placement details.
rl "INDEPENDENT'paddy placement means each individual Ile is bonded to the Channel Metal in its own,single
foam paddy-,the head laps are not bonded. This method is limited to 2-part tile adhesives- This method is limited
to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
?; "INTERDEPENDENT"paddy placement means each individual file is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap,or two tiles are bonded to the Channel Metal using a single
foam paddy- Allowable performance data below for'INTERDEPENDENT'paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE2A:PERFonmANCELINRrATiONs—IMON-HVHZ-iNDFPENDFRn•PADDYPLACEmENT
(1 To 1 MARGIN OFSAFETYALREADYA0110)
Hip/Ridge Metal Adhesive Allowable Uplift
Design i Metal Type Tile TypePlacement i11150
Hip&Ridge ! day or 3M"'2-Component Foam Roof
Channel Metal galvanized concrete Tile Adhesive AH 160 independent
169
galvanized,Gaivalumee,aluminum or day or (3M"'Z-Component Foam Roof
Trim Lock stainless steel concrete f Tile Adhesive AH 16Q independent 173
Trim Lock Plus galvanized,Galvalume',aluminum or day or 3M"'2-Component Foam Roof independent 178
stainless steel concrete Tile Adhesive AH 160
TABLE2B:PERF13RMANcELimrrATIDNS—Nc)"VH-1,INfE7i BmmENTPAODYPLAamw
(4T73 MARGIN OFSAFEIYALRFADYAPPMED)
Nip/Ridge Metal Adhesive Allowable Uplift
Design Metal Type Tile Type Placement IPsf}
Trim Lock or Trim galvanized,Galvalume,aluminum or day or 3Mr"2-Component Foam Roof Interdependent 98
Lock Plus stainless steel concrete Tile AdhesiveAH-160
galvanized,Galvalume�or stainless day or 3M"'Foam Rool Tile Adhesive
Trim Lock 1 interdependent 110
steel concrete RTA
Trim Lock aluminum day or 3M"'Foam RaoFT�leAdhesive interdependent 43
concrete RTA-1
galvanized,Gatvalumea,aluminum or day or 3M—Foam RoofTiie Adhesive interdependent 43
Trim Ladc Plus stainless steel concrete RTA 1
galvanized,Galva orstainless day or ,,,
Trim Lock steel concrete TILE BOND RaofTile Adhesive Interdependent 152
Trim Lack aluminum day or TILL BONDS'RoofTReAdhesive Interdependent 82
concrete
Trim Lock Plus galvanized,Galvalume9,aluminum or day or TILE BONDI"RoofTcle Adhesive interdependent 82
stainless steel concrete
Trim Lock galvanized,Galvalume`or stainless clay or Touch'n Seal StormBand Roof interdependent 148
steel concrete Tile Adhesive
day or Touch'n Seal StormBond Roof
Trim Lod: Aluminum interdependent 61
concrete TleAdhesnre
Trim Lod:Plus galvanized,Galvalumea,aluminum of day or Touch'n Seal StormBond Roof interdependent 61
stainless steel concrete Tile Adhesive
Eutertor Research!and Design,LLG Evaluation Report E10240.08.08-R4
t1:rc7rarte afAertha fiation 99503 Fi5374-R4
Revision 4:03/17/2015
-• _-.-. _ Page 5 of 7-
• ♦ I
ERD
TR
.1
6. INSTAUAMON:
6.1 The roof deck shall be minimum 15/32 inch plywood(non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6Z Hip&Ridge Channel Metal and Trim Lack Channel Metal shall be installed using min.11 ga.x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch oc. along both deck flanges. Fasteners shall he
positioned%rinch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to
FBC RAS 11.11,Drawing 13,Detail 3;RAS 119,Drawing 12.Detail 3;or RAS 120,Drawing 1.5,Detail 3.
63 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to setup prior to installation of roof tiles.
.� 0.- �
Grew of Polyset AH160 Placementfor Trim Lock Plus Channel Metal Installation
6.3.1 it is critical that the bond between the Trim Lock Pius Channel Metal,the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
63.2 'Approved underlayments are the codified'30/90'system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
exterior Research and Design,LLG Evaluation Report E10240.08.08-R4
P15374-R4
eerttirec[e ntairttewlraGon assa3 Revislon 4:03/1712025
?age 6 of 7
• ll RI@`CITY ERD
6.4 Tileishall be installed atop the Channel Metal in accordance with the tile adhesive manufacturees Approved,published
installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSAJTRI April 2012(04-12)or RAS
1-181,RAS 119,RAS 120 requirements.
,...� Hip/Ridge Tile
•�'�\ Tile Adhesive
Trim Lock Plus
��: •e :!
=; - Mortar or Weather Block
Adhesive
�i' -f Tile Adhesive
I
Viety of Trim Lock Plus Channel Metal installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive.
7. BUILDlive Pmf6irr REQUIREMEUM:
i
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
i
8. MANUFAM-URIt96 PIAUM.-
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements.
9. QUALFTYASSURAnice ENT ry:
Architectural Testing,Inc—QUA1844,(717)764-7700
-END OF EVALUATION REPORT-
Exterior Research and Design,LLG Evaluation Report E10240.08-138-R4
CardJEute of Aurharr=d=83503 FL5374-114
Revision 4:03/17/2015
Page 7 of 7
' RECEIVED
f Certificate of Authorization No.29824
i 4 K
x, Nov 1020 17520 Edinburgh Dr
T i Tampa,FL 33647
;ppe,m ng Department (813)480-3421
TECH RCCAL SFERV i� ucie County
EVALUATION REPORT FLORIDA BUILDING CODE 6T"EDITION{2017)
i
Manufacturer:I BORAL ROOFING LLC Issued February 19, 2019
7575 Irvine Center Drive
Irvine,CA 92618
www oralar a \LE Copy
www.boralamerica.com -
Manufacturing Plants: Lake Wales,FL
Okeechobee,FL
Quality Assurance: PRI Construction Materials Technologies(QUA9110) REVIEWEDFOR
SCOPE CODE COMW I
T. LUCIE COUNTY
Category: Roofing
Subcategory: Roofing Tiles
Code Sections: 1507.3.5, 1507.3.7, 1523.6.5, 1523.6.5.2, 1523. ind2, 15 n Rai. CC
W
Properties: Physical Properties,Attachment Requirements,Wind Driven Rain,Static Uplift
Resistance
REFERENCES!
Enti Report No. Standard Year
American Test Lab of South Florida Inc(TST3782) RT0201.01-19 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0130.01-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0426.01-14 TAS 112 1995
ASTM C 1492- 2003(2009)
American Test ab of South Florida Inc(TST3782) RT0615.02-11 TAS 112 1995
L
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.03-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0615.04-11 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.02-16 TAS C 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.03-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0617.04-16 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0623.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test Lab of South Florida Inc(TST3782) RT0624.04-14 TAS 112 1995
ASTM C 1492 2003(2009)
American TestLab of South Florida Inc(TST3782) RT0624.05-14 TAS 112 1995
ASTM C 1492 2003(2009)
American Test!Lab of South Florida Inc(TST3782) RT1210.02-15 TAS 112 1995
ASTM C 1492 2003(2009)
American TestLab of South Florida Inc(TST3782) R11210.03-15 TAS 112 1995
ASTM C 1492 2003(2009)
Miami-Dade BCCO(CER1592) 14 0408.06 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 14-0416.12 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 15-0721.04 FBC(HVHZ) 2017
2017
Miami-Dade BCCO(CER1592) 16-0112.07 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 16-0112.08 FBC(HVHZ) 2017
Miami-Dade BCCO(CER1592) 18-0509.15 FBC(HVHZ) 2017
Miami-Dade B;CCO(CER1592) 18-0509.16 FBC(HVHZ) 2017
Miami-Dade 5.CG0(CER1592) 18 0509.17 FBC(HVHZ)
BOR18003.1 j
FL28328-RI Page 1 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid:
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
z
i
i
BORAL ROOFING LLC
i Concrete Roof Tiles CEEK
TECHNICAL SERVICES, LLC
Enti Report No. Standard Year
Tile Roof Institutet Membership Confirmation TAS 100 1995
TAS 101 1995
TAS 102&102(A) 1995
BOR18003.1 FL28328-R1 Page 2 of 12
This evaluation'report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation 'report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
1
BOR
a AL ROOFING LLC
fl R1 K Concrete Roof Tiles
TEcHMICAL SERVICES. LLC
PRODUCT DESCRIPTION
Bermuda (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile,interlocking,class III concrete roof file
Allowable Applications: For mechanically fastened(direct deck or batten),mortar set or adhesive set applications
Dimensions: 16"x 10"
T71'
t
Figure 1. rnuda
Plantation (Okeechobee)
Profile/Description: AST 1492,TAS 112 Type 3a,flat profile,interlocking,class III concrete roof tile 1
Allowable Applications: Fo echanically fastened(direct deck or batten),mortar set or adhesive set app'cation
Dimensions: 1 -1/2"x 13"
A--1/
13�
Figure 2. Plantation
BOR18003.1 FL28328-RI Page 3 of 12
This evaluation report is provided for SNp of Florida product approval under Rule 61G20-3. Th anufacturer shall notify CREEK
Technical Services,LLC of any product cha s or quality assurance changes throughou duration for which this report is valid.
This evaluation report does not express nor imp rranty, installation,recomme use,or other product attributes that are not
specifically addressed herein.
BORAL ROOFING LLC
? E�l] Concrete Roof Tiles
T ECi 11.4CAL SERVICES, LLC
Saxony 9004!Slate, Shake and Split Shake (Lake Wales and Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 3a,flat profile,interlocking,class III concrete roof file
Allowable Applications: For mechanically fastened (direct deck or batten),mortar set or adhesive set applications
Dimensions: 17"x 13"x 1-5/32"(Slate)or 1-9/32"(Shake and Split Shake)
' II
o \
NDERLOi K
Figure 3. Saxony 900 Slate
NA HOLES
` L
Figure 4.Saxony 900 Shake
i NAIL HOLES
' 7
L
Figure 5.Saxony 900 Split Shake
BOR18003.1 FL28328-R1 Page 4 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation;report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
`-- BORAL ROOFING LLC
kkl� Concrete Roof Tiles
y a aEla
s+
TECHNjCAL SERVICES, LLC
Estate "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 1 b,low profile,interlocking,class III concrete roof file
Allowable Applications: For mechanically fastened(direct deck or batten),mortar set or adhesive set applications
Dimensions: 16-1/2"x 13"
Nail Holes
Tz':
•
`-,
Figure 6. Estate
Villa 900 (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 1 b,low profile,interlocking,class III concrete roof tile
Allowable Applications: For mechanically fastened(direct deck or batten),mortar set or adhesive set applications
Dimensions: 17.0"x 13"x 2-1/8"
NaH holes
I
12"
- Overlock
pile.,
17" t
Underlock I` }
f 13"
Figure 7.Villa 900
BOR18003.1
FL28328-R1 Page 5 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
1
F-- �, BORAL ROOFING LLC
CRE ' Concrete Roof Tiles
TECHNICAL SERVICES,. LL C
Barcelona 900 (Lake!Wales)
ProfilelDescription: ASTM C 1492,TAS 112 Type la,high profile,interlocking,class III,'S'shaped concrete
roof the
Allowable Applications: For mechanically fastened(direct deck or batten),mortar set or adhesive set applications
Dimensions: 17"x 13"x 3-518"
MAIL VOLES
r.,
1 OVERL OCK
1ii/
3 Z's
ti
UNt?ERLOCK ,
Figure 8. Barcelona 900
i
Galena Spanish "S" (Okeechobee)
Profile/Description: ASTM C 1492,TAS 112 Type 2a,high profile,interlocking,class III'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened(direct deck),mortar set or adhesive set applications
Dimensions: 17"x 10"x 2.7"
Fastener Holes
\\\\,
10
Figure 9. Galena Spanish "S"
BOR18003.1 FL28328-R1 Page 6 of 12
This evaluation'report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation!report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
i
BORAL ROOFING LLC
Cr"i , RAC Concrete Roof Tiles
TECHNICAL SERv[CES, LLC
Spanish "S" Nuevo (Lake Wales)
Profile/Description: ASTM C 1492,TAS 112 Type 2a,high profile,interlocking,class III'S'shaped concrete
roof tile
Allowable Applications: For mechanically fastened(direct deck or batten),mortar set or adhesive set applications
Dimensions: 17"x 9-3/4"x 2-27/32"
Fastener Holes"
-o
17"
9-3/4"
Figure 10.Spanish "S" Nuevo
APPLICATION METHOD
Installation I
Limited to slopes 3:12 or greater in the HVHZ;Outside the HVHZ, shall be in accordance
Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition Revised or RAS 118, RAS 119, or RAS 120, as
applicable.
Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction
Roof Deck: at max.24 in.span;In the HVHZ,new construction shall be min.19/32 in,plywood at max.
24 in.span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ,the minimum underlayment
Underlayment: shall be installed as described in RAS 118,RAS 119,or RAS 120,as applicable.
BOR18003.1 FL28328-Rl Page 7 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Servlces, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
— --- — -------specifically-addressed herein. -- -----—— ... - — ---- - -- ------ -—— - ---- - ---- --
f t SORAL ROOFING LLC
FConcrete Roof Tiles
TECHNICAL SERvicEs, LLC
Data for Attachment Calculations for Direct to Deck Applications
Aerodynamic
Nominal Weight(W)and. Restoring Moments due to Gravity:-,Ms(ft-lbf) .
Multipliers
Dimensions(I x w) 3 Direct Deck
Roof Tile (ft )
VII Ib I'(ft) = w(ft) Direct Deck 3":12 4":12" 5"_12" 6":12 >7":12" .
( Application
Bermuda 9.7 1.33 0.833 0.205 6.97 6.86 6.71 6.54 6.35
Plantation 11.6 1.375 1.08 0.289 7.79 7.67 7.52 7.32 7.04
Saxony 900 10.9 1.417 1.08 0.315 7.62 7.5 7.34 7.16 6.95
Estate"S" i 10.0 1.375 1.08 0.289 6.74 6.64 6.50 6.33 6.14
Villa 900 10.9 1.42 1.08 0.315 7.62 7.50 7.34 7.15 6.95
Barcelona i 900 11.5 1.417 1.08 0.301 7.00 6.90 6.76 6.60 6.42
Galena 8 5 1.42 0.833 0.235 6.13 6.03 5.89 5.74 5.57
Spanish"S"
Spanish"S" ;8.95 1.417 0.8125 0.233 5.93 5.83 5.70 5.56 5.39
Nuevo
Data for Attachment Calculations foe`$att6n Applications ,
Aerodynamic
Nominal Weight-.(W)and: Restoring,Moments;due;to Gravity-M9(ft-lbf)
Multipliers
Roof Tile j Dimensions.(I:x:w): ( 3 Direct.Deck
Batten..
W(lbf) I(ft) w(ft). Application 3":12" 4":127: 5":12" 6":12" >7"-12"
Bermuda 9.7 1.33 0.833 0.189 6.53 6.43 6.29 6.14 5.97
Plantation 11.6 1.375 1.08 0.267 6.85 6.75 6.61 6.44 6.26
i
Saxony 900 10.9 1.417 1.08 0.291 - 6.61 6.48 6.31 6.13
Estate"S" 10.0 1.375 1.08 0.267 5.91 5.82 5.70 5.66 5.40
Villa 900 10.9 1.42 1.08 0.291 - 6.56 6.42 6.26 6.08
Barcelona 11.5 1.417 1.08 0.286 6.19 6.19 6.06 5.92 5.76
900
Spanish"S" ;Nuevo 8 95 1.417 0.8125 0.215 5.30 5.21 5.09 4.96 4.82
BOR18003.1 FL28328-R1 Page 8 of 12
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
_ � BORAL ROOFING LLC
�y� h Concrete Roof Tiles
TECHNICAL SEPVICES, 3 L C
Attachments Resistance Expressed as-a Mornent for Mechanically Fastened Applications
Tile Fastener Mi.(ft-lbf)
Roof Tile Direct Deck =Ditect Deck
Type Count Size Shank Clip (min.15/32 (min.19132" Battens
plywood)' plywood)
Nail 2 10d Ring N/A 30.9 38.1 17.2
Nail 1 10d Smooth N/A 7.3 9.8 4.9
or Screw
Nail 2 10d Smooth N/A 14.0 18.8 7.4
or Screw
Screw 1 #8 N/A N/A 30.8 30.8 18.2
Bermuda, Screw 2 #8 N/A N/A 51.7 51.7 24.4
Plantation or .
Saxony 900 Nail 1 10d Smooth Field 24.3 24.3 24.2
or Screw
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth Field 35.5 35.5 34.8
or Screw
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Nail 2 10d Ring N/A 50.3 65.5 48.3
Nail 2 10d Ring NIA 27.8 37.4 28.8
Nail 1 10d Smooth N/A 8.8 11.8 4.1
or Screw -
Nail 2 10d Smooth NIA 16.4 21.9 7.1
or Screw
Screw 1 #8 N/A N/A 25.8 25.8 22.9
Estate"S"Z, i Screw 2 #8 N/A N/A 47.1 47.1 49.1
Villa 900
Nail 1 10d Smooth Field 24.3 24.3 24.2
or Screw
Nail 1 10d Smooth Eave 19.0 19.0 22.1
or Screw
Nail 2 10d Smooth or Screw Field 35.5 35.5 34.8
Nail 2 10d Smooth Eave 31.9 31.9 32.2
or Screw
Estate"S" Nail' 2 10d Ring NIA 43.0 67.5 50.9
I
E
I !
Continued on following page
BOR18003.1 FL28328-RI Page 9 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
-+ - BORAL ROOFING LLC
_ff Concrete Roof Tiles
T ECHNI'CAL SERVICES, LLC
Attachment,,Resistance Expressed as a Moment for Mechanically Fastened Applications
Tile Fastener Mf(ft-lbt)
Roof Tile Direct Deck Direct.Deck
Type Count Size, Shank Clip (min:.15/32"- (min.19/32° Battens
plywood):. 'plywood)
Nail 2 10d Ring N/A 28.6 41.2 19.4
Nail 1 10d Smooth NIA 5.1 6.8 2.8
or Screw
Nail 2 10d Smooth N/A 6.9 9.2 7.3
or Screw
Screw 1 #8 N/A N/A 20.7_ 20.7 18.1
Barcelona 9001, Screw 2 #8 N/A N/A 43.2 43.2 29.8
Galena or
Spanish"S" Nail 1 10d Smooth Field 23.1 23.1 19.0
Nuevo or Screw
Nail 1 10d Smooth Eave 29.3 29.3 24.0
or Screw
Nail 2 10d Smooth or Screw Field 27.6 27.6 38.6
Nail 2 10d Smooth Eave 38.1 38.1 41.8
or Screw
Nail 2 10d Ring N/A 33.1 48.1 45.2
Notes_ 1)Not for,Saxony 900,Villa 900 or Barcelona 900. Installation with a 4"file headlap and fasteners are located a min.2-1/2"
from head of tile.
2)When using only one fastener,use the hole that is approximately 4-3/4"away from interlocking edge.
3)Direct Deck applications only.
Attachment Resistance Expressed as a Moment for Adhesive or M.orta.r,
Paddy. Average Paddy.
Roof Tile Adhesive Product-Approval Count ;Weight(grams)`
_. Mr(ft-lbf)
Dow Chemical TILE BONDn' NOA 16-0222.01 2 13.9 31.3
Bermuda, ; 2 8 31.3
Planation and ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 40.4
Saxony 900
1 45 118.9
2 8 59.0
DAP Foam Inc.Touch N'Seal® NOA 17-0829.12 1 24 45
Saxony 900I Storm BondTm 2 Two-Component 1 45 93
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 43.9
Dow Chemical TILE BONDT"'' NOA 16-0222.01 2 11.4 26.1
2 8 26.1
Estate"S"or, ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 45.5
Villa 900 1 54 86.61
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 20.6
2 8 55
DAP Foam Inc.Touch N'Seal® NOA 17-0829.12 1 30 40
Villa 900 Storm BondTm 2 Two-Component 1 60 70
BOR18003.1 FL28328-R1 Page 10 of 12
This evaluation'report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation;report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
• BORAL ROOFING LLC
I C R EK Concrete Roof Tiles
TECi-NI.CAL SERVICES, LLC
Attachment Resistance Expressed as a Moment for Adhesive or Mortar Set
Paddy Average.Paddy _ Mr it-Ib
Roof Tile Adhesive Product Approval ( fl
Count Weight(grants)
Dow Chemical TILE BOND-RI NOA 16-0222.01 2 10.7 29.3
Barcelona 900,1 2 8 29.3
Galena Spanish ICP Adhesives Polyset AH-160 NOA 17-0322.03 1 24 38.7
"S"or Spanish 1 1 63 66.5
"S"Nuevo
Premix Marbletite, Inc.TILE-TITE NOA 17-1016.07 N/A N/A 24.5
2 8 66.0
Barcelona 900E DAP Foam Inc.Touch N'Seal® NOA 17-0829.12 1 30 63
Storm Bondn"2 Two-Component 1 60 82
Notes: 1)See manufacturers product approval for installation requirements.
LABELING
1) All tiles shall bear the identifiable marking of the manufacturer's name or logo as follows:
Manufactured in Lake Wales, FL
Manufactured in Okeechobee, FL
OR
BOR18003.1 FL28328-RI Page 11 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
' r
BORAL ROOFING LLC
1 CREEK Concrete Roof Tiles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Fifth Edition Revised and the manufacturer's published
application instructions. Installations in the HVHZ shall comply with RAS 118,RAS119 and RAS 120.
3) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
4) All product listed in this shall tested quarterly in accordance with TAS 112 Appendix A.
5) Installation of the evaluated products shall be limited to projects in areas subjected to weathering indices of
50 or greater as illustrated in ASTM C 1492-03,figure 1 (see below).
50 50
WEATHERING REGIONS
I NEGLIGIBLE WEATHERING
—I MODERATE WEATHERING
SEVERE WEATHERING
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest P.E. have demonstrated compliance with the Florida Building
Code,6"'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
eR a e�sssBB
2019.02.1
E
NSF S��s
No 74021 /2W5 - 9 10:10:22
-05'00'
�`.• S TAT E OF
441e
O R 1 P' ��°'® Zachary R.Priest, P.E.
Florida Registration No.o S••••-•.. . C?
organization No. 021
ANE9641
CERTIFICATION!OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R.Priest; P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest;P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
BOR18003.1 FL28328-R1 Page 12 of 12
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.