HomeMy WebLinkAboutBuilding PlansEXISTING ROOFING EXISTING WOOD TRUSSES 24-c.c1 EXISTING FASCIA-/ EXISTING SOFFIT EXISTING STUCCO GRADE R30 INSUL. 1/2" GYP. BOARD EXISTING C.B.S. EXTERIOR WALLS -1 x 2 P.T. FURRING 24"o.c. R4.1 FOIL INSUL, OVER FURRING 1/2- GYP. D.W. EXISTING CONCRETE FOUNDATION Ext. C.B.S. Wall Detail MTS12 with (14) 10d x 1 1/2"at each Truss Top Plate 5/8" T-111 Siding fastened to studs as per Nailing Schedule Cover with one layer of House Wrap - \ Exterior Grade wI Min. (2) 2 x 4 Top Plate with (1) SP4 at each stud with (6) 10d `2 x 4 studs 16"o.c RI Batt Insulation —at frame section at Entry Door Interior (1) 2 x 4 p.t. Sill Plate with (1) SP4 at each stud with (6) 10d nails Fasten to concrete with 5/8" dia. x 8" long wedge bolt 32"o.c. and $ from ends with 1/8" x 3" washer Existing Concrete Foundation Ext. Frame Wall Detail 24 s.h. 24 s. h. s'-0" +/ $ ,m Cord of Wood Truss 2 x 4 top plate Fasten with (2) 16d at each truss `1/2" gyp. d.w. 2 x 4 studs 24"o.c. 2 x 4 p.t. sill plate wood base _Cased Hard Coil Nails 12-o.c. max. 0.00' F.F.E. _ \-Existing Conc. Foundation Interior Wall Section Non Load Bearing Wall Non Brng. Header Storage Non Air Conditioned Non Bring Header Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy New Exterior Frame Infill Wall Porch (2) 24 s. h. o CBS Infill Living \_New Exterior Exist. 28-x 24" Frame Infill Wall Opening 3068 New Kitchen Layout Ref. Cabinet Drawings by Carport water Others p line Range & O� Kit. Exhaust Hood 10011 Renovated Floor Plan scale: 1 /4" = V-0" aim Family Dining 23 (2) 24 s.h. s.h. NO CHANGE TO THE EXISTING INTERIOR LAYOUT OTHER THAN WHAT IS NOTED IN THESE PLANS S.G.D. E. Project Data Project Name: Mike T. Foster Street Address: 176 NE Estia Lane City: Port St. Lucie County: St. Lucie State: Florida Scope of Work Residential Demo & Renovation Update Kitchen & Bathroom Replace all Drywall Update Electric Service to 200A Upgrade Electrical Reconfigure Bathroom and Air Handler Location New Windows and Doors to their existing sizes Design Loads Roof Live Load: 20.0 p.s.f. Wind Speed: 150 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent:.18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Bdrm. 3 (2) 23 s.h. 4068 1., m N 23 s.h. Planter Safety Glass Building Data Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 1,911 s.f. Building Code 2017 Florida Building Code: Residential 2017 Florida Building Code: Existing Bldgs. Alteration Level II 2014 National Electrical Code: NFPA 70 Area Tabulation U � CV ® W 0 Z M _ U- L, d- W W L y a I co (n Q Z i1 ai U {a LU N Living: 1,178 > O Carport: 219 LO Porch: 292 N Entry: 38 > Storage: 184 _N Total 1,911 Cubic Volume: 10,458 c.f. v z r � v O s � <D - `Y. u- V_ Al U 3 r\ J LID W CV a til M W q T \J O 04 C /y C) {L r\ `/ Z M (2) 24 s.h. _ .._ O Ll LL Z O ^� N W 4068 > Q -J J O U- Bdrm. 2 24 s.h.LU J 0 Z W co New Condenser Upit fastened to Concrete Pad W 2668 Louver a+s 5068 A r New Air Handler N Location s. ,.:�,1 . gF. date revision r(w 1.0/31/19 `Client Review a Master Bdrm. 24 s.h. drawn Checked :. J. date 10/31/19 scale as noted (3) 23 s.h. job number 19070 sheet A-1 Corigated Metal Masonry Ties 8-o.c. vertical in each mortar joint, Fastened to existing masonry jamb Existing Cast in Place Tie Beam Existing CBS Exterior Wail Existing Masonry Opening Masonry Opening "In Fill" Fill in the existing openings with CBS 8 x 16 x 8 and mortar m 0 0 o. 0 0 W .y N LX w 3/8- continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck - e wbo r= Ov0 O'm ;4 C =®W �Ooc J c m E O OB N U to N d o B o N d U m'm M T 0 stucco finish perimeter caulk / Attach p.t. bucks J with 8d coil nails at 12"o.c. Typ. Alum, window _ jamb or sliding glass doorjamb QM Min. 1 1/4" embedment at windows and min. 1 1 /2" embedment at a a sl. gl. doors ° a d" d 1/2" drywall \--1/4" max. struct. shim caulk attach as per manufacturers product approvals NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Coat Bucks with Protecto LMW200 Coating after they have been installed and Chaulked Window & Door Flashing Detail at CBS Wall (Existing) 2" v.t.r, To Existing Plumbing contractor to provide a Sewer Main shut off valve at each fixture each fixture Insulate all hot waier lines Plumbing Riser Diagram n.t.s BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 1/4" DIA. TAPCONS WITH 1 1/2'" EMBEDMENT INTO C.B.S. SET A 6" FROM CORNERS AND AT 12"o.c, MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS 4" FROM ENDS AND 12"o.c. STRUCTURAL NOTES: All wood in contact with masonry shall be pressure treated or approved seperating material. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before proceeding. Ceramic Tile Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, All 18.1, Al 18.3, A136.1, & A137.1. Fiber mat reinforced backer shall be used behind wall applied ceramic tiles in the tub and shower areas and conform to ASTM C1325. Per Durock, cement board exceeds ASTM C1325. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION All Design and Construction shall be inaccordance with the current Gypsum Note American Concrete Institute (ACI). and the American Institute of Steel Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047 SHEATHING NAILING ruction (RISC), The Florida Building Code and all applicable C1177, C1178, C1278, 01396, or C1658 and installed per FBC residential loon code. Per USG, Wallboard conforms to C1396. Nailing Schedule Structural Concrete shall attain a minimum ultimate compressive strength Gypsum Board & Gypsum Panel Products (Fc') in 28 days as follows: ROOF &FLOOR DIAGRAM Use sheathing with #8 gun nails at 6"o.c. Column Footing and Wall Footing: g g: 3000 p.s.i. Gypsum board and gypsum panel products shall be applied at right angles or parallel to framing members. All edges and at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. Column and walls from foundation to roof: see column schedule. All other concrete: 3000 ends of gypsum board and gypsum panel products shall p.s.i. occur on framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum ROOF SHEATHING TO GABLE END FRAME All wood members shall have a minimum fiber stress in bending board shall not be installed where it is directly exposed to weather or to water. Use #8 gun nails at 4-o.c. of 1200 p.s.i. with 1 /360 max, deflection. EXTERIOR SHEATHING All bolted connections shall be 1 /2"" Cadmium plated or better. Wall and ceiling gypsum board shall be fastened with screws spaced at 12"o,c. Screws for attaching gypsum board and gypsum Use #8 gun nails at 4'"o.c. at panel edges and #8 gun nails at 4""o.c at panel top and La bolts to be used only g y in shear connections with minimum panel products to wood framing shall be Type W or Type S in accordance with ASTM 01002 andshall penetrate thewood not bottom and 6" o.c. in field 4"" threaded penetration past steel plate. less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel products shall be attached to cold formed steel framing less Lag bolted conditions shall be drill tapped no larger than the than 0,033°" (1 mm) thick shall be Type S in accordance with internal thread diameter and shall not be hammer driven. ASTM 01002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8" to 0.112" shall be in accordance with ASTM or (1mmhe GENERAL REQUIREMENTS bugle head style in accordance with ASTM 1513. Screws for d style s for 6" 10/10 attaching gypsum board or gypsum panel products to structural New Plumbing Wy`y M Pipes All work to be as per the current edition of the Florida Building Code insulated panles shall penetrate the wood structural panle facing not less than 7/16""o.c. (11.1 mm). and meet or exceed all applicable local requirements. Saw Cut for New Existing Cone. Foundation General contractor is responsible for all labor, materials, utilities, testing, Gypsum board used as the base orbacker for adhesive application of ceramic the or other required nonabsorbent finish material shall Plumbing waste removal, storage, securing of site, accomodation, transport/freight, conform to ASTM C1396, C1178, C1278. Use of water resistant and all other cost related to the completion of this project., unless explicitly gypsum backing board shall be permitted on ceilings. Water identified here. resistant gypsum board shall not be installed over a Class 1 or _ Class 2 vapor retarder in a shower or tub compartment. Cut or Owner is responsible for all municipal related charges such as impact exposed edges, including those at wall intersections, shall be _ fees, and water connection, except building permit fees, which are to be sealed as recommended by the manufactuer. Water resistant ` included in the construction bid. sum backing board shall not be used where there will be gypsum direct exposure to water, or areas subject to continuous high .006 Visquine 4" 2500# cone. General contractor to check all drawings for errors and ommissions and humidity. min. bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors Wood Framing Note Before compaction and and ommissions are not reported in writingto the architect, any resulting Clean, Compacted, Cover provide support of damages or costs shall be born entirely by the general contractor. Wood framing supporting gypsum board and gypsum panel Termite Treated Fill drain pipes with concrete products shall be not less than 2"' (51 mm) nominal thickness to maintain required slope Architect is not responsible for the contractors method or means of in th least dimension except that wood furring strips not less Conc. Repair at Plumbing construction. than 1"" by 2'" (25mm x 51mm) nominal dimension shall be permitted to be used over solid backing or framing spaced General contractor is to keep the site in a clean and safe state through not more than 24"o.c. (610mm) out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Wire Lath Attachment PLUMBING NOTES: _ Unless otherwise noted, the installation of specified hardware shall Over wood framing the paper conform to the manufacturers instructions and standard practice. backed wire lath shall be installed Plumber to consult with contractor and equipment ordered over one layer of approved plastic for rough in dimensions. All plans and drawings are not considered complete until they have been house wrap. Lath shall be attached reviewed and approved by the City of Port St. Lucie Building Department horizontal framing members with 1.5' Verify all dimensions with the floor plan. The floor plan and the building permit has been issued. roofing nails and to vertical wood dimensions dictates all other dimensions on other sheets. framing members with 6d common nails or 1- roofing nails driven to Do not scale drawings, if any conflicts arise, contact the INTERIOR WALL FRAMING NOTE penetration of not less then 3/4"' of an inch, or 1 "" wire staples Architect or Engineer for clarification prior to construction. driven flush with the plaster base. All sanitary lines 2" or less shall have a slope of 1/4" per Interior non bearing walls to be 2 x 4 studs 24"o.c. Staples shall have crowns not less foot minimum.. Spruce, Pine, Fir (SPF) #2 Grade lumber or better than 3/4'" and shall engage not less than three strands of lath and All sanitary lines above 2"" shall have a slope of 1/8°" per MTS12 10d x 1 with (14) penetrate the wood framing members 1/2"at each not less than 3/4". The fasteners must foot minimum. THRESHOLD NOTE Truss penetrate the wood framing members not less than 3/4-. Fasteners shall be Provide Anti -Scalding Valve in all showers. At egress door (Entry Door) the max. hgth. 7" o.c. max. of the threshold shall be 1/2" Plate 8'-0Top PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures Head: 6" max. from corners & 13.75" max. o.c. Jambs: FL#: 75412.3 Windows Series 7700 Singlehung Lawson Ind. Impact 6" max. from corners & 10.25"o.c. above meeting rail and 9 7/8" max. o.c. below meeting rail. Use 1/4" dia. Tapcons +38.7 -42.1 +/- 60.0 with 1 1/4" embedment into concrete. Head, Sill, & Jambs: 6" max. from corners. Head & Sill 13.25" FL#: 15441.4 Sliding Glass Dr. g SGD-9200 Lawson Ind. Impact p max, o.c. Jambs: 13.75"'max. o.c. Use (2) fasteners at each location. Use 1 /4" dia. Tapcons with 1 3/4" embedment into +38.7 -42.1 +/- 65.0 concrete Jambs: 12"" max. from corners & 36-o.c. Use #8 x 2"' Wood FL#: 7091.1 Swing Doors Wood Edge Steel Masonite Inter. N.A. screw at frame and 3/8"" Conc. screw with 1 1/4" embed, into +38.7 -42.1 +/- 70.0 concrete #9-16 or #10-14 Hex Head Wood Screws with sealed washer FL#: 14645.3 Roofing 5V Crimp Metal Sales Mfg. N.A. Fastener to penetrate the deck a min. of 3/8". Screws to be - 45.0 - 196.7 6-o.c. across panel ends & 12"o.c. in field. (2) 2 x 6 header with 1 /2" plywood flitch bond together with 16d 6""o.c. staggered -\ SP4 at each stud and 16'"o.c. max. along header. Use (6) 10d 1 1/2r" long for each fastener (2)2x4 top plate Header to Stud Ir / with (1) MSTA18 with (14) 10d DOOR ROUGH OPENING Door Framin At Exterior Wall It - (1) 2 x 4 under header and (1) 2 x 4 along side of header, bond together with 16d 6"o.c. SPH4 at each stud Use (10) 10d X 1 1/2" 2 x 4 p.t. sill plate fasten as per exterior frame wall section (2) 2 x 4 Top Plate with (1) SP4 at each / stud with (6) 10d 5/8" T-111 Siding III I '-- 2 x 4 studs 16"o,c fastened to studs as III per Nailing Schedule Cover with one layer of House Wrap --\ V C Q C-4 00 ® w -t PR Z M �.J O J _ LL u5 b 0 v w �U) AD CL w r J LPL ^04 Q � � Z it U ® > O _ OC Lo w M a) �'4^-)-% VJ C J u_ ®_ ai Aq U 3 W J U ur t w el N ,r, i I— V T p� °^o < LL S r. A m r` /p� 6 V 6t �• Z N 00 r O IL Z O w Q iv N � -u O LL I m w 1 Lu O^ T LL Z LLJ U) w LY- Exterior Interior (1) 2 x 4 p.t. Sill Plate date revision with (1) SP4 at each stud with (6) 10d nails 10/31 /19 Client Review Fasten to concrete with 5/8" dia. x 12" long wedge bolt 32'"o.c. and 6"' from ends with 1/8" x 3" washer Coat the existing concrete with a bonding agent and pour 4" of 2500# fibermix cone. to level the foundation. New concrete to extend drawn under frame walls. aa. 0.00' FFE checked Grade J=M in' `r :i date 10/31/19 Existing Concrete scale Foundation as noted job number 19070 sheet Frame Wall Detail A-2 At New Concrete at Storage Area ELECTRICAL LEDGEND ORECESSED LIGHT WITH LENS @ EXTERIOR & WET LOCATIONS j WITH L.E.D. BULBS f 3- SURFACE MOUNTED LIGHT FIXTURE Te SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE c� UNDER CABINET FLUORESCENT FIXTURE FRECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN O EXHAUST FAN OUTLET LJ DOOR CHIMES THERMOSTAT SMOKE & CARBON SD MONOXIDE DETECTOR DUPLEX OUTLET - SWITCHED �* TELEVISION c DUPLEX OUTLET 220 V OUTLET TELEPHONE 't1Y SWITCH PUSH BUTTON THREE WAY SWITCH - DIMMER SWITCH D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46— A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS U IQ In N Q M L W Z M _ J W LO ho COJ d� W L N a I 00 L] J LL N N <C .. N r` J Z c06 ELL U U_ ® > _I o LU a) �4-) V J J LL 150A :o be J d LO N LO d `W O 00 y � V C) N C �! Z Lu )A on VIIG IVIIVIVVVQYO L GVVV VVgLLS LVVV Wa LL5 One Ref. 1500 watts One Bath 1500 watts 0 One Dryer 4500 watts LL One Washer 1500 watts Water Heater 5000 watts Z O L W Total 33,534 watts Q N a) U c J First 10 KVA at 100°% 10,000 watts Q LOL 'J Remainder at 40% 9,444 watts (3) #2/0 (THW) copper W N +M-., U) and (1) #4 ground (THW) W Total 19,414 watts copper in 2 galy, conduit F- One AC Heat at 100% 10,000 watts (3) #2/0 (THW) copper J r X p Total 29,414 watts and (1) #4 ground (THW) copper in 2- galy. conduit F.P.L. service L '- a Z 29,414 W / 240 V = 122.E Amps W� New 200 Amp Service v) Remove the existing 150 Amp Service W� Panel: 200 A.M.C.B. 200 Amp Smoke detectors wired to 120V Bathroom lights g 1,0, 3W 40 Circuit 420/240 Volt Panel Disc. Non Switchable, Non GFt Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate a.c. electrical schedule if loads are to be modified disc. date revision Electrical Notes 10/31/19 Client Review 1. All loads to be checked by a Florida Licensed Electrician 5/8` dia. x 10'-0" long ground rod 3/4"' copper 2. All work to meet the National Electrical Code water pipe 3. Calculations and panels below are for sizing conduit and overall building load requirements only drawn s.i. 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box checked for exterior lights on building; AC, MC, or EMT conduit elsewhere. J. date 5. Ensure min. 36" clear between equipment and disconnects, Typical. 10/31/19 &_� scale tie ground wire as noted to footing rebars job number 19070 Electrical Riser Diagram sheet A-3