HomeMy WebLinkAboutEnergy Code' Component
Performance Method for
Commercial Buildings
Form 400B-97
ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department
of Community Affairs
r .
FLA/COM-97
Version 2.2
PROJECT NAME_TRI-COUNTY FEEDS___________
PERMITTING OFFICE:
ADDRESS:
ST. LUCIE COUNTY, _________
_Fort Pierce ________________
FORT PIERCE, FL
CLIMATE ZONE:
6 -----------
OWNER:
___________
PERMIT NO:
_XXXX____
AGENT:
_SAME
_'
JURISDICTION NO:_661100____
BUILDING TYPE: _Service Establishments_____
CONSTRUCTION CONDITION: New construction
DESIGN COMPLETION: Building__________
_Finished
CONDITIONED FLOOR AREA: _2200________-------------
NUMBER OF
ZONES: 1
MAX. TONNAGE OF EQUIPMENT PER SYSTEM:
5 ---------------------
• COMPLIANCE CALCULATION:
METHOD B
DESIGN
CRITERIA
RESULT
------
-----------------
^ENVELOPE PERFORMANCE
------
24-::32
--------
63.21
PASSES
OTHER.ENVELOPE REQUIREMENTS
PASSES
LIGHTING
INTERIOR LIGHTING
680.00
683.59
PASSES
EXTERIOR LIGHTING
120.00
576.00
PASSES
LIGHTING CONTROL REQUIREMENTS
PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER
10.00
10.00
PASSES
HEATING EQUIPMENT
1. Et
1.00
N/A
AIR DISTRIBUTION SYSTEM INSULATION
REQUIREMENTS
1. With Insulated Roof
6.00
6.00
PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATIdd EQUIPMENT
. PIPING INSULATION REQUIREMENTS
--------------------------------------------------------------------------=-
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE: -=sy` _=3E
I hereby certify that this building is
in compliance with the Florida Energy
Efficiency Code ,y�
-' OWNER/AGENT: �1
-- ---------
DATE :------- -` �=
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in accordance with
Section 553.908, Florida Statutes.
BUILDING OFFICIAL:
DATE:
I
BUILDING ENVELOPE SYSTEMS
UUM111-'L1h1a1JL,
CHECK
.:---------- ------------- -
401.------GLAZING--ZONE• 1------------------------
' `Area(Sgft)I
Elevation Type U Sc VLT Shading
----- ----------I
____
` North Commercial 0.58 .59 .47 Continuous Ove
I
301
North Commercial 0.58 .59 .47 Continuous Ove
Ove
601
West Commercial 0.58 .59 .47 Continuous
Ove
42I
" West Commercial 0.58 .59 .47 Continuous
Continuous Ove
81
West Commercial 0.58 .59 .47
Total Glass Area in Zone 1 =
1821
Total Glass Area =
1821
--------------------I--.-
402.------WALLS--ZONE- 1--------------------- U Insul R Gross(Sgft)I
Elevation Type -__________I
-----------4
____ ____ _____
. North 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151
1
East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4
3601
South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151
540
West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 4
1
18001
Total Wall Area in Zone
1e001
Total Gross Wall Area.=
403.------DOORS--ZONE 1---------------------- U Area(Sgft)I
Elevation Type --- - ------------_I
-- ------------------------------>-----
North 1-3/4 GLASSDOOR 1.3
1.3
421
,421
West 1-3/4 GLASSDOOR
Total Door Area in Zone 1 =
84I
Total Door Area =
841
404.------ROOFS--ZONE 1--------------
Insul R Area(S,gft)l
Color- U
Type ------- ---------,-I
___ ______
Sngl Ply/2"Iso/2" Conc/Mtl Deck Light .065 30
1 =
24001
I
Total Roof Area in Zone
Total_Roof_Area-=24001
405.------FLOORS-ZONE 1----------_-_^^--- Insul R Area($gft)l
Type ----------I
------------------
---- ----------- ----------- -----------
Slab on Grade/Uninsulated 0
1 =
24001
24001
Total Floor Area in Zone
=
24001
Total Floor Area
406.------INFILTRATION ------------------------------ -------------------.-I---
ICHECKI
Infiltration Criteria in 406.1.ABCD have been met.
I I
MECHANICAL SYSTEMS
CHECK
------------------------------------------ ------------- ----------1-----I---
HVAC load sizing has been performed. (407.1.ABCD)
I I
I ---
407.------COOLING SYSTEMS -------------------- -- ---------------�---------
IPLV
Tons I
,
No Ef-ficienc
- _
--------------
Type - -w--- ---
---------
I
-------------------
1 10 10
5,001
1. Split System
408.------HEATING SYSTEMS-------------------'T ---7
BTU/hr1
Effie
Type --------------I
1.0
340001
1. Electric Resistance 1
409.------VENTILATION --------
ICHECKI
Ventilation Criteria in 409.1.ABCD-have been met.
I I
410.-----AIR DISTRIBUTION SYSTEM ----------------------------------------- I---
CHECKI
--=---------------p-----�--
Duct sizing and design have been performed. (410.1.ABCD)
1 I
R-valuej
AHU Type Duct Location
-------------
-- I
1. Constant Volume With Insulated,Roof
61
CHECKI
------------------------- ---------------
Testing and balancing will be performed. (410.1.ABCD)
I, I
--1---
411.-----PUMPS AND PIPING -ZONE ---------------------------------__
- Basic prescriptive requirements in 411.1.ABCD have been met.
I I
PLUMBING SYSTEMS
411.-----PUMPS AND PIPING -ZONE I -----------------------------------
-Type R-value/in Diameter
-----=-----------=----•--------
Thicknessl
---------I
1. Non -Circulating 1
412.-----WATER HEATING -SYSTEMS -ZONE 1-------------------------- -------'-'I---
Type Efficlency StandbyLoss InputRate,
-------------------------------- ---- -___ .----
Gallons)
----------
ELECTRICAL SYSTEM$
CHECKI
413 . -----ELECTRICAL POWER DISTRIBUTION-=- - ----^----I--------- ------
Metering criteria in413_1_ABCDhave been met.
1 I
•
41 MOTORS-------- - - -----^--------------
Motor efficiencies in 414.1.ABCD have been met.
1 I
- _ 415.-----LIGHTING' SYSTEMS -ZONE 1---- ----.. -----1 ...---.-------_r
No Watts
�.------ I�--
Area(Sgft)l
Space Type No Control Type I No Control Type 2
-_ ..__-------
--------- I
------- --- ----- ----
Bulky Acti 1 On/Off 2 On/Off 1 680
22001
- Total Watts for Zone 168Q1
Total Area for Zone 1 r
22001.
Total Watts
6801
Total Area
22001
10HECKI
Lighting criteria in 415.1.ABCD have been met,
I I
-I-____I___
----------------=-----',----.T_--------
16.. Operation/maintenance manual will be provided to owner.(102,1)1 ^-_I---