HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida'Department of Business and Professional Regulation - Residential Performance. Method
ProjectName: WYNNE THE STERLING IMPACT
BuilderName: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE E. FL,
PermitNumber:
:
Owner: �'�j � 4�
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 1250.00 ft2 .
b. Frame- Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ftz
5. Is this a worst case? Yes
10.CeilingTypes (1504.0 sqft.)
Insulation. Area
a. UnderAttic (Vented)
R=30.0 1474.00 ftz
6. Conditioned floorarea above grade (ft2) 1474
b. Knee Wall (Vented)
R=19.0 30.00 ftz
Conditioned floorarea belowgrade (ft2) 0
c. NIA
R= ftz
11.. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. 0-Factor: SgI, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15:00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
.
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area.WeightedAverage SHGC: 0.284
14. Hot water systems
8. Floor Types (1473.5 sqft.) Insulation Area
a. Electric
Cap:.50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2
b. Conservation features
EF:0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads:, 47.94
PASS
Total Baseline Loads: 48.55
I hereby certify that the plans and specifications covered by
Review of the plans and.,8'
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance���
with the Florida Energy Code.
PREPARED �y: _ ..
Before construction is completed
DATE:'2p'2
this building will be inspected for
xx RG, r
compliance with Section 553.908
I hereby certify, that this building, as designed, is in compliance
Florida Statutes.
-< .
with the _Florida Energy Code.Q�:,
OWNEF!\� NET-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler, Unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance -with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH5,Q,(Rod .4 HIVED
FOR
FILE Co
E COMPLIANCE
P � UCIE COUNTY
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Complligoraia Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
StreetAddress
Building Type: User
ConditionedArea: 1474
Lot#
OwnerName:
Total Stories: 1 -
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuiiderName: WYNNE DEVELOPMENT RotateAngle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County.
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE ,
FamilyType: Single-family
FL ,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design DailyTemp
V DesignLocation
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792,
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM
329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes
6. BEDROOM 2
204 1632 No .0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY,
42 336 No 0
1 Yes
Yes'
Yes
9 GREAT/DINING
488 3904 ; No 0
1 Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 52 ft 0
329 ft2
____
0 1
0
2Slab-On-Grade Edge lnsulation
WIC 1 ft 0
63ft2
____
0 1
0
3 Slab -On -Grade Edge Insulation
M. BATH 8 ft 0
56 ft2
____
0 1
0
4Slab-On-Grade Edge Insulation
KITCHEN 1 ft 0
192ft2
_
0 1
0
5Slab-On-Grade Edge Insulation
BATH 5 ft 0
45 ft2
__
0 1
0
6 Slab -On -Grade Edgelnsulation
BEDROOM.2 32.2 ft 0
203.5 ft2
____
0 1
0
7Slab-On-Grade Edge Insulation
ENTRY 7ft 0
55ft2
____
0 1'
0
4/20/2020 3:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FI6Res2017 FBC 6th Edition (2017): Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY.'CHECKLI.ST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood Carpet
8Slab-On-Grade Edge Insulation LAUNDRY 6ft
0
42ft2
----
0
.1
0
9 Slab -On -Grade Edge Insulation GREAT/DINING 46 ft
0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
_ Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable orShed Metal 1553 ft2
246 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1.474 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic (Vented) BEDROOM
30
Blown
329 ft2
0.1
Wood
2 UnderAttic(Vented) WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic (Vented) M. BATH
.30
Blown
56 ft2
0.1
Wood
4 UnderAttic(Vented) KITCHEN
30
Blown
192ft2
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45ft2
0.1
Wood
6 UnderAttic (Vented) BEDROOM
30
Blown
204ft2
0.1
Wood
7 UnderAttic(Vented) ENTRY
30
Blown
55ft2
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42ft2
0.1
Wood
9 UnderAttic(Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) BEDROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Ornt To Uvall TypeSpace Cavity . Width
Ft In
Height
Ft In
Area
Sheathing Framing Solar
R41all,,& Fraction Ahqnr Grade%
Below
1 NE=>SW Exterior Concrete Block- Int Insul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block -Int Insul BEDROOM
4.1 28
0 8
0
224.0 ft2
0
01
0.4
0
3 NW=>SE Exterior Concrete Block - Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4 SW=>NE Exterior Concrete Block- Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int InsuBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int InsuBEDROOM 2
4.1 10
0 8,
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int InsuBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block- IntInsul ENTRY
4.1 6
0 8.
0
48.0 ft2
0
0
.0.4
0
11 SW=>NE Exterior Concrete Block- Int Insul ENTRY
4.1 1
0 8
0
8.O ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block- Int Insul LAUNDRY
4.1 6
0 8
0
48.0.ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int InsuIGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block- Int InsulGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/20/2020 3:04 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
Height Sheathing Framing Solar Below
_15 N=>S Garage Frame -Wood
KITCHEN 11 24 8
192.0ft2 0.23 0.4
0
DOORS
# Omt
DoorType
Space Storms
U-Value Width Height
Ft In Ft In
Area
1 SE=>NVV
Insulated
ENTRY None
.39 3 1 6 8
20.6 ft2
WINDOWS
Orientation shown its the entered.orientation => chan ed to Worst Case.
Wall
V # Omt ID Frame
Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening.
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.11 0.27 N
.32.9 ft2 1 ft0 in- 1 ft 5 in Drapes/blinds
6.9 ft2 1 ft0 in 1 ft 5 in None
24.0 ft2 6 ft 0 in 1 ft 5 in None
37.5 ft2 1 ft 0'in 1 ft 5 in None
40.0 ft2 8 ft 0. in 1 ft 5 in Drapes/blinds
Exterior5
None
None
None
Exterior5
GARAGE
# FloorArea
CeilingArea Exposed Wall Perimeter
Avg. Wall Height Exposed.Wallinsulation
1 315ft2
315ft2 24ft
8ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000356 1375.7 75.53 142.04 .1233 7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnit/
Split Single SEER:15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use SetPnt Conservation
1 Electric
None
Garage 0.97 50 gal 60.9 gal 120 deg None
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 4 of 5
FORM R405-2017 INPUT -SUMMARY::CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
SystemMcdel#
CollectorModel# Area Volume
FEF
None None
ft2
DUCTS
--Supply---
--- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 .175 ft2
Attic
65 ft2
DefaultLeakage
Attic
(Default) c(Default) c
-
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
Heatin�J Jan HFeb'
Mar
Mar
A r
E Apr
Ma
f May
Jun
Jun
Jul
Jul
Auge
AuSep
Oct .
. E Oct
Nov'
Nov
Dec
Dec
Venting [[ ]].Jan Feb
X Mar
[X] Apr
[ May
lun
Jul
Aug
Se
[X] Oct .
Nov
Dec
TherniostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
61
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78 -
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68.
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68.
.68
68
68
68.
68 .68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH_
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Defauit(8lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft •
0.3
LAUNDRY
Default 8Ibs/s .ft..
ft2
ft
-0.3
GREAT/DINING
4/20/2020 3:04 PM EnergyGauge® USA 6.0.02 (Rev; 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 4.02.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE'STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: Jurisdiction:
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the. building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a. continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ed ceiling/soffit
g /soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space. between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation.
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut -to fit, -or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
. Recessed light fixtures installed in the building thermal: envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall'be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
PytPnd behind piping and wiring.
Shower/tub
The air barrier installed'at exterior walls adjacent to showers land
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers. shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cailmnas,
a. In addition, inspection of log walls shall be in accordance with"the provisions of [CC-400.
4/20/2020 3:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
•' 2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, thel more'efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2r Single-family or multiple -family
2. Single-family
b) Return' ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. IS this a worst case? (yes/no)
5. Yes
b) Single package SEER .
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a). U-factor:(weighted average) 7a. 1.060
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284
c) Area 7c. 141.3
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab-on=grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior: .
1. Wood frame (Insulation R-value)
2. Masonry:(Insulation. R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
1101311. 11.0
1062.
14. Heating system:
Capacity 34.8
a) Split system heat pump
. HSPF 8.5
b) Single package heat -pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas.
AFUE
e) Gas furnace,. LPG
AFUE
f) Other
15. Water heating system.
a) Electric resistance EF, 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat.recovery unit. HeatRec%o
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 36.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c. 19.0
d) Multizone cooling credit
11d. No
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code; Energy, Conservation, through the above energy
saving features which wile be installed (or exceeded) in this home before final inspection. Otherwise, anew EPL _
display card will be completed based ,on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING a > A\�VQ'n'-6City/FL Zip: FT. PIERCE. FL"«
4/20/2020 3:05:01 PM EnergyGauge® USA 6.0.04 (Rev; 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1