Loading...
HomeMy WebLinkAboutProject Informationw rihIxsa � Projecf Summary n Date: '� Entire House By. QUICK CALLS, .INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772466.6796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THESTERLINGIMPACT, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce,, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15. OF Daily range ' L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654- Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent.(0 cfm) 0. Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swin multiplier Equipmen 0.95 Infiltration sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Duets 2319. Btuh Central vent (0 cfm) 0 Btuh He a[ Area Coolin�gg (none) (11F) 1474 1474 Equipment latent load 5277 Btuh Volume (iN) 12227 12227 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 30370 Btuh Equiv AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0. ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade' CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A O30 AHRI ref 7914585 Coil FX4DN(B;F)037 , AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input_ Sensible cooling 24360 Btuh Heating output, 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfm . Airflowfactor 0.'049 cfm/Btuh Airflowf6dor 0.044 cfm/Btuh 'Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF Backup: Input = 7 kW, Output = 23009 Btuh,100 AFUE Calculations approved byACCA to m6et all requirements of Manual J 8th Ed. '� ervrigt•tssfb° 2020,1arr0816�4:12 ��` ro Right.SJte®Uriversa1201619.0.07RSU08101 Page l ,AM.s1WrigM .Oft FNAGWYNNE-THE STERLING-IMPACT.np Calo=NU8 Frord Door faoes: N r- wri9bbow Right-JO Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM Job: Date: BY 1 Room name Entire House MASTER BEDROOM 2 3 Exposed wall Room height 1562 it 8.3 It d 52.0 ft 8.0 it heaV000l 4. 5 Room dimensions Room area 1473.5 fts 1.0 x 329.0 ft 329.0 1P Ty Construction number U-value (Btuh/fl�°F) Or HTM (Btuhd2) Area or perimeter (ft) (Bhuh) orsperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W L�G 13A-4ocis AA�c1om - 13A-4ocs 1A-c1om 11D0 13A4ocs . 13A-4ocs 1A-c1om 13A-4ocs :1A-clom 0143 1270 0.143 1270 0.390 0.143 0.143 1270 0143 1270 ; ne 'he se se se ".. s sw sw ' riw nw. 4.00; 36BI3. 4.00 35.56 10.92 : 4.00. 00 35.56 . 4.0U 35.56 2.55 .:70.43 2.55 34.77 11.31 2.65 2.55 42.91 -2.55 : 4524 479 ' : 38 128 24 22 34 360 7 290 33 , 442 . ". • 0 83 24 22 .34 353 5 217 : 0 1768 1344 331 848 236 136. 1414 247 867 1162 : 1124 2662 210 829 244 86 899 298 551 1 1478 '80 0 0 0 0 0 224 0 112 33 80 10 0 0 0 .. 0 224 0 '79 -0 3.20 1 . : 0 0 0 0 • 0 897 0 318 1162 204' ' 0 0 0 0 .0 570 0 202 1478 v� �G W . N! -G IAI G P C F 4A5 tam . 12C-0sw 16A30md ". 22A tol . 0.770 0.091 0.032 0.689, nw - - 21.56 2.55 . 0.90 27.69 . 27.54 .128. 2.32 o.ob 41 192 -. 1474 1474 , 0: 192 1474 156 880 489 1320 4325 1124 246 . 3419 0 0 0 .329 329 0 0 - 329. 52 0 0 295 1440 0 0 763 0 6 c) AID excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 609 249 b) Room ventilation 0 0 0 0 13 Intemalgains: Oocupants@ 230 5 1150 2 460 Applianceslother 2000 0 Subtotal (lines 6to 13) 18188 17877 5341. 4606 Less extemal load 0 0 0 0 Lesstranskr 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 6341 4606 15 Dud loads 31% 48% 5654 8536 31% 48% 1660 2199 Total room load 23842 26413 1 7001 6805 Air required (dm) 1160 1160 341F 299 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -�`�- wfrNrigla ofJt" 2020-Jan-081624:12 -41-M Right-Sufe®Uriversal 201919.O.OZ RSU08101 Page 1 .:.s\WdghlsoftHVAC\WVNNE--THESTERLING-IMPACT.np Calc=MJ8 FrontDoorfaces: N -- wrghtsoii Right-J® Worksheet Job Entire House babe: QUICK CALM, INC. By 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone:772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M BATH 2 3 Eased wall Room height 0 It .8D It heaftol EID It 8D ft heaVcool 4. 5 Room dimensions Room area 7D x 9D It 63D T 7.0 x 8D ft 56D flz Ty . Construction number U-value (BhjhNP-°F) Or HTM (Bhuh/IN) Area or perimeter (ft) Load (Btuh) or�perimeetter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool. Gross NOS Heat Cool 6 11 13 . Aom. ;,1Aclom 13A� 1Ao1om 1100 ,13AAocs 13AAocs 1A-c1om 0:143 1270 0.143 1270 0.390 0.143 0.143 1270 rie .'oe' se se se s sw sw 4.00 . 35.56: 4.00 35.56 10.92 4.00 4.00 35.56 2;55 Z0.43 2.55 34.77 11.31 2.55 2.55 42.91 0 ' . 0 . 0 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 7 0 : 0 0 0 0 0 57 5 0 0 0 0 0. 228. 247 0. 0 0 0 0 145 298 D W: VN �G 13AAocs 1A-clom 0.143 1270'_nw. 'nW 4.00' 35.56 2.55 , 4524 0' 0 0 0 0 0 0 0, 0 0 '0 0 0_ U " ' .'0 : 0 4Ai5 tom 12C-Osw =A 30md 22A-tpl rO.770,:nw, 0.091 0.'032 0.989 - 21.56 2.55 7 0.90 27.69 27.54 128 , 2.32 0.00 0 0 63, 63 . 0 0 63 0 - 0 0 56 0 A 0 -146 0 0 0 56 56 0 0 ` . 56 .8 0 0 . :60 222 . 0 0 " 130 0 P `C F 6 c)AEDexarsion -2 225 'Envelopelossigain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Intemalgains Oavpants.@ 230 0 0 0 0 Applianoes(other 0 0 Subtotal (lines 6to 13) 56 145 •887 836 Less exlemal load 0 0 0 0 Lesstransfer 0 0 0 0 14 Redistribution Subtotal 0 56 0 145 0 887 0 836 15 Ductloads 31% 48% 18 69 31% 48%1 276 399 Tonal room load. 74 214 1162 1235 Air required (dm) 4 9 57 54. Calculations approved bvACCA to meet all requirements of Manual J 8th"Ed. " 9 2020-Jao-081624:12 C� Right-SUteO Universal 201919.0.07 RSU08101 Page 2 s\WrighlsoftWAQWYNNE-THE STERLING-IMPACT.rup Calc=W8 Front l)oorfaces: N IF wrightsoft =use Worksheet Job: Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax T72-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 ,Exposedwall 0 ft. 5.0 3 Room height 8.0 ft . heat/000l .ft 8.0 ft heaftol 4. Room dimensions 1.0 x 192.0 ft 9.0 x 5D , ft 5 Room area 192.0 ft' 45.0 fF Ty U-value Or HTM Area (W) Load Area - (T) Load number�on ( F) (BtuhlfF) or perimeter (ft) (Btuh) or perimeter (ft) (Ekuh) Heat Cool Gross • N/P/S Heat Cool Gross N/P/5 Heat Cool 6 13A-0as 0.143 ne 4.00 -2,55 : 0 ' 0 0 . '- 0 . 40 40 160 102 1Ac1om = 1.270 = ne 35.56 .. 70.43 - : - 0:.' : '0 0 .0; 0 0 :0 : ' ' ---0 13AAocs 0.143 ' se 4.00 2.55 0 0 0 0 0 0 0, 0 1A-Glom 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W.:- :. =13A-40cs. 0.143 s 4.00 '255 0 0 0 0 0 0 0 0 �G 13AAo s 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1Ao1om 1270 sw 35B6 42.91 0 0 0 0 0 0 0 0 13,4 o 0.143 twit 4.011 -2.55 0 0 0 0 0 0 -0 0 1A1om 1270 nw 35.56 4524 0 0' 0 0 p 0 0 0 4A5 2am.: 0.770 nw 21.56, 27.54 0. 0 0 0 0 0 0. 0 P 12C 0snr 0.091, - 2.55 . 128 64 64 163 82 0 0 0 0 16A30md 0.032 '- 0:90 . =2.32 '. 192 192 . 172 445 , 45 ; : 45 ' 40 104 F 22A tpl 0.989 - 27.69 0.00 192 0 0 0 45 . 5 138 0 6 c)AEDexcursion -27 -2 Envelope lossigain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 •0 0 0 13 Internal gains: Occupants@ 230 0 0 0 • 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) .335 2501 426. 228 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 228 15 Ductloads 31% 48% 104 1194 31% 48% 133 109 Total room load F I 439 3695T 559 336 Air required (dm) 21 162 27 15 Calculations appmvedbvACCAto meet all requirements of Manual J 8th Ed. �'� wr>igtiatsoft^ 2020-Jarr08.1624:12 Right+SuteOUriversal201919.0.07RSU08101 Page slWdgHsoftWAQWYNNE-THESTERLING-IMPACT.np CaIc=MJ8 FrorRDoorfaces: N - WrIghtsoW Right.,J® Worksheet Job: Entire House bate: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 .F�posedwall 322 it 7.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/000l 4 Room dimensions . 1.0 x 203.5 ft ID x 55.0 ft 5 Room area 203.5 T 55.0 iP Ty Construction U-value Or HTM Area (1F) Load Area (fP) Load' number (131uh/IP--°F) (BWh/fP) or perimeter M (Btuh) or perimeter (ft) h) Heat Cool Gross N/P!S Heat Cool Gross N/P/S Heat Cool 6 V�1 L-G ] 3A-4ocs ' .0.143,:; he • 4.00 2.55 128 128 ' :513 326 0 0 0, 0. 1A c1.om 1270 ne , 35:56' 70:43 0 0 . 0 0 0 0 0 U VLG 13A-4ocs 0.143 se 4.00 2.55 .80 56 225 143 48 26 106 67 1A-c1om 1270 se 35.56 34.77 24 24 848 829 0 0 0 0 11 D 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 . 244 W .,, ;13A4ocs. 0.143 : ; s 4.00 -2.55 34 ,' 34 ., 136 86 ' 0 0 0 : 0 t-G 13A-4ocs 0.143 sw 4.00 2.56 16 16 64 41 . 8 8 32 20 IA-c1om 1270 sw 35.56 42.91 D 0 0 0 0 0 0 0. 13A�oCs 0.143 nw - 4.00 2.55 0 0 0 0 0 0 0 ,.0 1A�dom 1270 nw, 35.58 4524 0 0 0 0 0 0 0 0 i4A5 tom : `0:770 ,. nw . 21:56 27.54 D - 0 p 0 0 ' . 01 : 0 .: p P, 12C-0sv 0.091. - 2S5 128 0 0 0 0 72 72 183 92 C . ..::16"Orr d 0.032 .;-= "' ' 0.90 2.32 '' 204'I -204 . 182 472 . - 55 55 49 F 22/.tpl 0.989 27.69 0.00 204 32 891 0 . 55 7 194 ...928 0 ' 6 c) AED wcursion -24 ' -g Envelope loss(gain 2859 1873 800 545 12 a)Infiltration 564 . 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Oowpants@ 230 1 230 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 3422 2257 922. 579 Less eidemal load 0 0 0 0 Less transfer 0 0 0. 0. Redistribution 0 0 0 0 14 15 Subtotal Ductloads 3422 .2257 , 922 579 31% 48°/a 1064 . 1078 31% 48% 287 276 Total room load 4486 3335 1209 855. Air*uired(dm) 218 146 59 38 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. Right•Sdte®Universal201919.0.07RSU08101 2020-Jarr081624:12 ...s\WdghtsoftWAQWYNNE-THESTERLING-IMPACT.rp Ca•Ic=MJ8 Front Door faces. N Page -9- vurightsoft, Right-JO Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: By. 1 Room name LAUNDRY GREATIDINING 2 3 Exposed wall. Room height 6.0 It 8.0 it heaV000l 46.0 ft 8.9 ft heaV000l 4 5 Roam dimensions Room area 7.0 x 6.0 ft 42.0 fF ID x 488.0 ft 488.0 fN Ty Construction number U-value (BtuhfiF--°F) Or HTM (BUh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (fly or perimeter- (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 G 13A-0acS , :'1Ac1cm '. 13A-4ocs 0143 1270 0.143 ;;ne 'rie` se 4.00, 3556. 4.00 .2.55 70A3 2.55 0 0 0 0 0 0 0 0 0 0 0 231 38 0 194 0 0 775 " 1344 0. 493. 2662 0 11 1Ac1om 11DO 13A-4ocs 13A4ocs 1Aclom 13A4ocs %A Iom U5-2om'. 12C-0sw 16A-3Omd 22A-tol 1270 0.390 0.1.43 0.143 1270 0143 1270 0.770 0.091 0.032 0.989 se se . s sw snr •"riw ' .nw -'nw - ' = 35.56 10.92 4.00 4.00 35.56 4.06, 35:56 2156 2.55 0.90 27.69 34.77 11.31 2.52.55. 5 42.91 2.55 4524 27.54 128 2.32 0.00 0 0 0 48 .0 0, 0. 0 56 42 42 0 0 0 48 0 0 0 0 56 42 6 0 0 0 192 0 0 0 0 143 : 38 166 0 0 0 122 0 -0 0 0 72 - . 97 0 0 0 0 0 0 178 0 41 0 488 488 0 0 0 0 0 137 0 0. 0 488 46 0 0 0 0 0 549 0 880 0 437 1274 0 0 0 0 0 - 349 0 . 1124 0 ,. . • 1132 0 D .W T-G c-G P C -.. . F 6 c) AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Applianoeslother 0 0 Subtotal (lines 6 to' 13) 644 317 6154 6409 Lessextmalioad 0 0 0 0 Lesstransrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 151 Ductloads 31% 48% 200 151 31% 48% 1913 3060 Total room load 844 468 8067 9469 Air rouired (dm) 41 21 393 416 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - w"aftrSolt- 2020-Jan-081624:12 RightSiiteO Uriversa1201919.0.07 RSU08101 Page 5 s\WdgHsoftWAC\WYNNE-THESTERLING-IMPACT.np Calc=MJ8 FrontDoorfaces: N Duct System -Summary ' -- wlrightsoft� 'Job:Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phor e:772-466-6799 Fax 772.466-6796 Email: QUICKCALCS@,40L.COM . For: WYNNE DEVELOPMENT THE STERLING IMPACT, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250/0.250 in H2O 0.284 in/100ft 1160 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Lri (ft) Ftg.Equ Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox 0 VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 .0.374 6.0 OxO VIFx 18.6 115.0 st1 ENTRY h 1209 59 38 0.510 4.0 Ox 0 VIFx 3.0 95.0 GREAVDINING c 4735 196 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 Ox 0 VIFx 28.1 135.0 st2 KrrCHEN c 3695 21 162 0.375 7.0 Ox 0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0:366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 Ox 0 VI Fx 21.6 115.0 st1 MASTERBEDROOM•A h 3501 170 149 0.207 6.0 OxO VIFx 33.1 135.0 st2 MASTERBEDROOM•B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 WIC c 214 4 9 0.3104.0 Ox 0 VI Fx 1 26.3 1 135:0 1 st2 Trunk Htg Clg Design Veloc Diam H x W Duct. Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 ' 724 _ 0.284 938 12.0. 0 x 0 VinIFIX st1 st1 PeakAVF 1101 1122 0.284 1050 14.0 0 x 0 VinlFlx wright�soft- 2020-Jarr081624:13 ��� <mwvecunh.n.m®.r�.wn, Rigtt-Sute@Uriversal20l9l9.0.07RSU08101 Page 1 ...'slWrighisoftHVACIWYNNE-THE STERLING=IMPACT.nQ CaIc=MJB Front Door faces: N Return Branch Detail Table Name Grille Size (in) . Htg (cfm) . Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W . (in) . Stud/Joist Opening (in) . . Duct Mat Trunk. rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wrightsof - ��• au,nvemmn.wro�y�p, Right-SUte®Uriversal201919.0.07RSU08101 A ...sUrightsoftHVAQWYNNE-THE STERLING•IMPACT.rLp Calc=MJ8 Front Doortoes N 2020•Jarr081624:13 Page 2