HomeMy WebLinkAboutDensity Reports - Dollar General Store, 12.14.20UES Project No.:
Date Typed:
0310.2000358.0000
December 14, 2020
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materials Testing Services
FIELD AND LABORATORY REPORT COVER PAGE
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
As requested, Universal Engineering Sciences, LLC. (UES) representative(s) performed construction materials testing and/or
field inspection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. The contents of this package are summarized below:
Scope of Work
Work Order No.Date Type of Report
132390-1 12/10/2020 In-Place Density Test Report w/Activity Record
132390-2 12/10/2020 In-Place Density Test Report
132390-3 12/10/2020 In-Place Density Test Report
132390-4 12/10/2020 In-Place Density Test Report
We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the undersigned.
Sincerely,
Universal Engineering Sciences, LLC.
Certificate of Authorization No. 00000549
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
This item has been electronically signed and sealed by
Richard E. Hoaglin, P.E. using a Digital Signature. Printed
copies of this document are not considered signed and
sealed and the signature must be verified on any electronic
copies.
ICC Email: brandon.paul@fulcrumgroup.com; brian.k@fulcrumgroup.com
UES Project No:
UES DOCS No:
UES Report No:
On-Site Time (hrs):
Lab Time (hrs):
Travel Time (hrs):
Total Time (hrs):
0310.2000358.0000
132390-1 ARC 121020
1.75
0.00
2.00
3.75
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
Date of Activity:Thursday, 10 December, 2020
Technician:Russell Brause
As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose
of earthwork testing for the Building pad.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
Building Pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to
meet the project compaction requirements of 100% of the maximum dry density per ASTM D-698.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
Building pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 100% of the maximum dry density per ASTM D-698.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
Building pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 100% of the maximum dry density per ASTM D-698.
While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for
Building pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet
the project compaction requirements of 100% of the maximum dry density per ASTM D-698.
UES Project No:
UES DOCS No:
UES Report No:
0310.2000358.0000
132390-1 DT 121020
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In-Place Density Test Report
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
Area Tested:Building pad 8"
Type of Test:Field:ASTM D-6938 Nuclear Gauge Method Date of Test:12/10/2020
Lab:ASTM D698 Standard Proctor
Technician:Russell Brause
Requirements:100% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.Location of Test Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
1 SW corner.0 to -8
inch
8.00 26523 110.2 9.6 101 A
2 NW corner.0 to -8
inch
8.00 26523 109.7 9.6 101 A
3 NE corner.0 to -8
inch
8.00 26523 111.0 10.1 102 A
4 SE corner.0 to -8
inch
8.00 26523 110.4 9.5 101 A
(1)Ref. Datum: 0 = Top of Final Grade (3) Comments Key
(2)
Proctor
#
Maximum
Dry
Density
Optimum
Moisture
Content
26523 109.0 12.0
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UES Project No:
UES DOCS No:
UES Report No:
0310.2000358.0000
132390-2 DT 121020
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In-Place Density Test Report
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
Area Tested:Building pad
Type of Test:Field:ASTM D-6938 Nuclear Gauge Method Date of Test:12/10/2020
Lab:ASTM D698 Standard Proctor
Technician:Russell Brause
Requirements:100% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.Location of Test Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
5 SW corner.-8 to -16
inch
8.00 26523 109.4 10.0 100 A
6 NW corner.-8 to -16
inch
8.00 26523 110.4 10.1 101 A
7 NE corner.-8 to -16
inch
8.00 26523 110.2 10.6 101 A
8 SE corner.-8 to -16
inch
8.00 26523 109.2 12.6 100 A
(1)Ref. Datum: 0 = Top of Final Grade (3) Comments Key
(2)
Proctor
#
Maximum
Dry
Density
Optimum
Moisture
Content
26523 109.0 12.0
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UES Project No:
UES DOCS No:
UES Report No:
0310.2000358.0000
132390-3 DT 121020
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In-Place Density Test Report
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
Area Tested:Building pad
Type of Test:Field:ASTM D-6938 Nuclear Gauge Method Date of Test:12/10/2020
Lab:ASTM D698 Standard Proctor
Technician:Russell Brause
Requirements:100% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.Location of Test Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
9 SW corner.-16 to -24
inch
8.00 26523 110.8 10.0 102 A
10 NW corner.-16 to -24
inch
8.00 26523 110.7 10.3 102 A
11 NE corner.-16 to -24
inch
8.00 26523 109.8 10.4 101 A
12 SE corner.-16 to -24
inch
8.00 26523 110.2 12.7 101 A
(1)Ref. Datum: 0 = Top of Final Grade (3) Comments Key
(2)
Proctor
#
Maximum
Dry
Density
Optimum
Moisture
Content
26523 109.0 12.0
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.
UES Project No:
UES DOCS No:
UES Report No:
0310.2000358.0000
132390-4 DT 121020
820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
In-Place Density Test Report
Client:Fulcrum Construction Group, LLC
810 Manci Ave
Daphne, AL 36526
Project:Dollar General Store 8736 Ft. Pierce
Virginia Avenue & 38th Street, Ft. Pierce, St. Lucie County, FL
Area Tested:Building pad
Type of Test:Field:ASTM D-6938 Nuclear Gauge Method Date of Test:12/10/2020
Lab:ASTM D698 Standard Proctor
Technician:Russell Brause
Requirements:100% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
only and do not address the condition of the underlying soils below the tested depths.
Test
No.Location of Test Range
Depth
(inch)
Proctor
(2)
Field Dry
Density
(PCF)
Field
Moisture
%
%
Compaction
Comments
(3)
13 NW corner.-24 to -32
inch
8.00 26523 109.7 11.1 101 A
14 SW corner.-24 to -32
inch
8.00 26523 111.3 11.6 102 A
15 SE corner.-24 to-32
inch
8.00 26523 111.4 12.5 102 A
16 NE corner.-24 to -32
inch
8.00 26523 110.5 12.0 101 A
(1)Ref. Datum: 0 = Top of Final Grade (3) Comments Key
(2)
Proctor
#
Maximum
Dry
Density
Optimum
Moisture
Content
26523 109.0 12.0
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E. Recompacted, Retested, Meets Requirements
This test was performed without deviation from ASTM procedures.
This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.