HomeMy WebLinkAboutproduct approval (2)BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts 'I Publications Contact Us BCIS Site Map Links ` Search
db, r Product Approval
4USER: Public User
1, 1 I I r Y
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL9777-1112
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg, keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/07/2023
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL9777 R12 COI OCR14002.9a
2017 FBC Evaluation Report Weatherlock
Non-HVHZ final.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D 1970
2015
ASTM D 226
2009
ASTM G 155
2005
TAS 103
1995
UL1897
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
C
Date Submitted
04/06/2020
Date Validated
04/06/2020
Date Pending FBC Approval
04/13/2020
Date Approved
06/02/2020
Summary of Products
FL # W Model, Number or Name
Description �-
9777.1 Weatherlock G—�
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R12 II OCR14002 9a 2017 FBC Evaluation Rep_
Weatherlock Non-HVHZ finai.pd
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9a 2017 FBC Evaluation Reps
Weatherlock Non-HVHZ finai.�df
Created by Independent Third Party: Yes
�—
9777.2
WeatherLock G (High Tear)
Weatherproofing Underlayment
Limits of Use _
Installation Instructions
Approved for use in HVHZ: No
FL9777 R12 II OCR14002.9a 2017 FBC Evaluation Rep_
Weathercock Non-HVHZ final.pd
Verified By: Zachary R. Priest PE-74021
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ final.pdf
--- `" �-
Created by Independent Third Party: Yes
9777.3
Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation instructions
Approved for use in HVHZ: Yes
FL9777 R12 II OCR14002.9b 2017 FBC Evaluation Repot
Approved for use outside HVHZ: No
a therl HVH fin p�
Impact Resistant: N/A
erified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9b 2017 FBC Evaluation Report
Weatherlock HVHZ final.pdf
Created by Independent Third Party: Yes
9777.4
Weatherlock MAT
Waterproofing Underlayment
_
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R12 II OCR14002 9a 2017 FBC Evaluation Reps
Weatherlock Non-HVHZ final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ
T
t Third
Created by Independent Third Party: Yes
— — �
9777.5 WeatherLock Metal
T---
Weatherproofing Underlayment v v
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R12 II OCR14002.9a 2017 FBC Evaluation Repor
Weatherlock Non-HVHZ final.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ final.pdf
Created by Independent Third Party: Yes
-�:f9777.E
—
WeatherLock Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL9777 R12 II OCR14002.9b 2017 FBC Evaluation Report
Weatherlock HVHZ final.odf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R12 AE OCR14002.9b 2017 FBC Evaluation Report
Weatherlock HVHZ final.p 1L
Created by Independent Third Party: Yes
9777.7 1 WeatherLock specialty Tile & Metal
Weatherproofing Underlayment
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-142.5
Other: See evaluation report for limits of use.
Installation Instructions
FL9777 R12 II OCR14002 9a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL9777 R12 AE OCR14002 9a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ final.odf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Qopyright 2007-2013 State of Florida.:: Pri y Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to
this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida
Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may
be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the
Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Rom
® cilreck
Credit Card
Safe
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6T" EDITION (2417)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Subcategory:
Code Sections:
Properties:
REFERENCES
Roofing
Underlayments
1504.3.1, 1507.1.1
Physical properties
Entity
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
Report No.
NEI-039-02-01
NEI-042-02-01 REV2
NE►-045-02-01
NEI-045-02-01
NEI-053-02-01
NEI-053-02-01
NEI-093-02-02
OCF-213-02-01
OCF-237-02-01
OCF-252-02-01
OCF-252-02-01
OCF-253-02-02
OCF-272-02-01
OCF-293-02-01
OCF-296-02-02
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
PRI Construction Materials Technologies (TST5878)
OCF-318-02-01
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
PRI Construction Materials Technologies (TST5878)
OCF-320-02-01
PRI Construction Materials Technologies (TST5878)
OCF-321-02-01
PRI Construction Materials Technologies (TST5878)
OCF-322-02-01
PRI Construction Materials Technologies (TST5878)
OCF-355-02-01
'Determined to be equivalent to ASTM D 226-09, Type I
and II
Standard
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
TAS 103
ASTM G 155
ASTM D 1970
ASTM D 1623
UL 1897
ASTM D 4798
ASTM D 1970
ASTM D 1970
TAS 103
ASTM D 1970
ICC-ES AC 188'
ICC-ES AC 48
ASTM D 1970
ASTM D 1970
TAS 103
ASTM G 155
ASTM D 1623
UL 1897
UL 1897
Issued April 3, 2020
Year
2015
2015
1995
2005a
1995
2005a
2015
2009
2012
2001
2015
2015
1995
2015
2012
2012
2015
2015
1995
2005a
2009
2012
2012
OCR14002.9a FL9777-R12 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock@ Undedayments (Non-HVHZ)
WeatherLock@ G
WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
(Brentwood, NH or
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
Houston, TX)
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a
mum 30 days.
WeatherLock@ Mat
therLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or
)-SBmodified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX)
olls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
--------- _._.__..
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLock@ Metal
WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH)
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@
WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal
constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or
The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft.
Houston, TX)
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock@ G (High
WeatherLock@ G (High Tear) is a self -adhered, underlayment used as an alternative to
Tear)
ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer
(Houston, TX)
modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 654
WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.9a FL9777-R12 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Underlayments (Non-HVHZ)
TECHNICAL SERVICES, LLC
PRODUCT APPLICATION
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3" side
laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if
applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underavment Svstem No 1_ - WeatherLock Specialty Tile & Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c.
Underlayment: WeatherLockV Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.9a FL9777-R12 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Undedayments (Non-HVHZ)
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
•�'�C E NSA. FSJ'�
No 74021
STATE OF : 41J
Nam:
�i40 /4f
CERTIFICATION OF INDEPENDENCE
2020.04.03
15:55:05
ayrn.gw ev n.xwar,n
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.9a FL9777-R12 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.