Loading...
HomeMy WebLinkAboutProduct Approval i • II Florida Building Code Online Page 1 of 2 I I . s f }'k rAl'e/An ate' a BCIS Home hLog In`; User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links ; Sea rich o Product ApprovaUSER:Public Userdb r Iaa E�al �q Product Approval Menu>Product or Application Search>Application List>Application Detail _ 4't{Fisc;33 I i FL# FL1654-1119 E Application Type Revision Code Version 2014 Application Status Approved THESE PLANS AND ALL PROPOSED WORK Comments ARE SUBJECT TO ANY CORRECTIONS Archived ❑ REQUIRE®BY FIELD INSPECTORS THAT Product Manufacturer POLYGLASS USA RMAY -NECESOARV,Iw ORD R T® Address/Phone/Email 150 Lyon Drive �C\tIB�� 1pyg 4AB B'��F�M�g ICA �ip CODES-c Fernley,NV 89408 .. d4��n 4�fi°ac+B�e@ �a �J en (570) 384-1230 Ext 242 jakins@polyglass.com I Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive [/1(\, _ Fernley,NV 98408 ST.LUCIE COU-N'TV BUMPTV1C.u1VI5ION (602)363-7139 FIFVUENV ,D FOR COWL I-CE stevew@polyglass.com � VII;�Er DATE Quality Assurance Representative James Akins PLANS AND p ,R MIT MjjST BE 1UPT 014 Jgn Address/Phone/Email 555 Oakridge Road OR NO INSPECTION WILL JJF°,hMXA Humboldt Industrial Pkwy Hazleton,PA 18201 (800)894-4563 ' jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich,PE R Validation Checklist-Hardcopy Received Certificate of Independence FL1654 R19'COI 2016 01 CO I Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 FM 4474 2004 I http://www.floridabuild ng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 2/7/2i017 � I ' I Florida Building Code Online Page 2:of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 SummarV of Produ cts FL# Model, Number or Name Description 1654.1 Polyglass SBS and APP SBS and APP modified bitumen roof systems Modified Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R19 II 2016 04 FINAL Al ER POLYGLASS MODBIT FL1654- Approved for use outside HVHZ: Yes R19.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.)The design pressure in this Evaluation Reports application relates to one particular assembly FL1654 R19 AE 2016 04 FINAL ER POLYGLASS MODBIT FL1654- over concrete deck. Refer to the ER Appendix for R19.Ddf other systems and deck types.2.) Refer to ER, Created by Independent Third Party: Yes Section 5 for other Limits of Use. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card' Safe t r I I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFg... 2/7/2017 • F_ h�.jl r7 ku1 3 TRINITY ERD APPENDIX I:ATTACHMENT REQUIREMENTS FOR WIND UPUFr RESISTANCE. Table Deck Application Type Description - Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 1B-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Banded Roof Cover 5-9 18-2 Wood New,Reroof(Tear-Oft)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover i 12 ID Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 13-14 IE Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 15-16 1F-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 17-19 1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 20-22 1G Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 22 2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 23 2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 24-25 2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 26-27 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28-32 3B Concrete New or Reroof(fear-Off) F Non-Insulated,Bonded Roof Cover 32 4A LWIC New or Reroof(rear-off) A-1 Bonded Insulation,Bonded Roof Cover 33-34 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 34 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 35-37 SA CWF New or Reroof(fear-Off) A-1 Bonded Insulation,Bonded Roof Cover 38 SB CWF New,Reroof(fear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 39 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 40 5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 40 SE CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 40 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-42 6B Gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Banded Roof Cover 42 6C Gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 42 6D Gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 42 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 43-45 7B Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 45 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper coded and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢Wood: Minimum 0.75-inch penetration. I ➢Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted,Insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,periite,gypsum-based roof board or mineral-wool roof board that meets the qA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 2505.1 and,forfoam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,U.C.d/b/a Trinfty)ERD Evaluation Report P9290.02.08-R17 for FL16544R39 Certificate of Authorization#9503 Revision 17:04/18/2016 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 1 of45 i I V I i I, TR N1TY Q_CIERD , 1 4. Minimum 200 psi,minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck.The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ.Load resistance of the roof deck shall be documented through proper coded and/or FBC Approval documentation. S. Unless otherwise noted,insulation adhesive application rates are as follows.Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢Hot asphalt(HA): Full coverage at 25-30 Ibs/square. ➢Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-Inch o.c. D Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. D OlyBand Classic(OB Classic): Full coverage at 1 gal/square. ➢ICP Adhesive&Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. D Note:When multiple layers(s)of insulation and/or coverboard are installed in ribbon-appfied adhesive,board joints shall be staggered. ➢Note:The maximum edge distance from the adhesive ribbon to the edge of the insulation boardsholl be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted.Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables,rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below maybe used as a drop-in for the equivalent thicker material listed in the table: ➢Millennium One Step Foamable Adhesive(M-OSFA): MDP -1575 psf (Min.0.5-inch thick) ➢OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) D OMG OlyBond 500(OB500): MDP -1875 psf (Min.0.5-inch thick ISO 95+GL) ➢OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) ➢OMG Oly8and 500(011500): MDP -4875 psf (Min.0.5-Inch thlckACFoam II) ➢ICP Adhesives&Sealants CR-20: MDP -1175 psf (Min.La-inch thick) 7. Bonded polyisocyanurate Insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded Insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 127 and FM LPDS 1-29. Assemblies marked with an asterisk'carry the limitations set forth in Section 2.2.15.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements. j 9. Forfully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 10. For mechanically attached components over existing decks,fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system.Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing In accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 orTAS 124. 12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC Is referenced,refer to current LWIC Product Approval for specific deck construction and limitations.For systems where specific LWIC Is not referenced,the minimum design mix shall be 300 psi.In all cases,the minimum top-coat thickness is 2-inches.For LWIC over structural concrete, reference Is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02-08-R17lfor F11654-1139 Certificate of Authorization n95D3 Revision 17:04/18/2016 Prepared try:Robert Nieminen,PE-59166 Appendix 1,Page 2 of 45 I � rs �qa I TRINITY ERD . 14. Unless otherwise noted,refer to the following references for bonded base,ply or rap sheet applications. ` .TABLE 1:POLYGWSS ROOF COVERS Reference Layer Material Applicable BP-AA Base Ply One or more plies Polyglass G2 Base,FBCApproved ASTM D4601,Type II (Base and Ply sheets,Asphalt- Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV orVl Hot Asphalt at 20-40 Applied) Nate: As halt-applied sheets or insulation shall not be applied topoly-film surfoaedmembranes. Ibs/square i Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Polyglass HT Base 650 SBS-CA1 Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastashield TS-G,Elastashield TS-G FR,PoIVFresko G PG350 at 1.5-2.0 Cap SBS(sand-backed),Polyfresko G SBS FR(sand-backed) gal/square . Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6 Polyplus 35 at 1.5-2.0 SBS{A2 Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G gal/square Cap SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Polyglass SBS AA HT Base 650 Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR, Hot Asphalt at 20-40 (SBS,Asphalt-Applied) Cap Elastoflex G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Ibs/square Note: Asphalt-applied sheets or insulation shall not beapplied to poly-jgmsudhoed membranes. SBS-TA Base Ply or Ply One or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Polyglass HT Base 650 (SBS,Torch-Applied) Cap Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield T56 FR, Torch-Applied Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed) Base Ply One or more plies Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR SBS-SA Cap Elastoflex SA P,Elastoflex SA P FR Polyreflect (SBS,Self-Adhering) Unless otherwise noted,permissible membrane substrates for SOS-SAare limited to the SBS-SA Base Ply options herein, Self-Adhering Note: Rastobase/poly/sand or Elastobase poi/poly). APP-TA Base Ply or Ply One or more plies Polyglass APP Base,Polyflex,Polybond (APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR Torch-Applied APP SA Cap Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool (APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering Elastobase(poly/sand)or Elastobase/poly/poly). 15. Any of the fallowing FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Nan-Fibered Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG700QS(Quick Set)High Quality Elastomeric Roof Coating or KM Acryl 25-QS(for granule-surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70Q5(Quick Set)Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS(for granule-surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.020S-R17 for FL16544119 Certificate of Authorization N9503 Revision 17:04/18/2016 Prepared by:Robert Nieminen,PE-59166 Y AppendixQ,Page 3 of 45 I I I � kipILI I i I TPJNI1Y ERD 16. The following represent priming requirements for gypsum-based coverboards: ➢ Dens Deck and Dens Deck Prime shall be field-primed with PG100 prior to self-adhering or torch-applied membrane application.No priming is required for hot-asphalt membrane applications. ➢ SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application. 17. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the fallowing Maximum Design Pressure(MDP)limitations.The lesser of the MDP listings below vs.those in Table 3A applies: VAPOR BI OPriONs;SYRUCfURAL CONcRM DECK;AnHEREO INSULATION PER TA111E3A Option ff Primer Vapor Barrier Insulation Adhesive MDP(psf) Type Attach 1 PG100 Elastoflex SA V Plus Self-Adhering Inta-Stik or CR-20,12-inch o.c. -60.0 2 PG100 Polyglass APP Base Torch-applied Into-Stik or CR-20,12-Inch o.c. -75.0 3 PG100 Elastoflex SA P Self-Adhering Insta-Stik,12-inch o.c. -75.0 4 PG100 Elastoflex SA P Self-Adhering Millennium One Step Foamable Adhesive,12-inch o.c. -157,5 5 PG100 Elastoflex SA P Self-Adhering CR-20,12-inch o.c. -270.0 18. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. i I Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-R17 for FL3654-R19 Certificate of Authorization R9503 Revision 17:04/18/2016 Pmpamdby:Robert Nieminen,PE-59166 Appendix 1,Page 4 of4S I I I i i i it - • • � ��� -ram ....,� ��`,, � ;x I i TRINII;Y I ERD TABLE 1F-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)ORREcOVER SYSTEMTYPEE:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(scREvvs&PLATES),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover(See Table 1) MDP No. Note 1) Type Fasten Attach Base Ply Cap (PA W 134 Min.19/32- Elastobase,Elastobase P(poly-film Dekfast Hex with Dekfast#14 or Trufast 3'Metal 12-inch o.c in 4-Inch lap and 12-inch o.c.in two 585-SA SBS-SA'APP-SA; -525• Inch plywood top) Insulation Plate with Trufast HD (2),equally spaced,staggered center rows SBS-TA,APP TA W-135 Min.19/32- Elastobase,Elastobase P(poly-film Dekfast Hex with Dekfast R14 orTrufast 3'Metal 12-inch o.c.in 4-Inch lap and 12-Inch o.c.in two Polyflex SA Base APP-TA -S2.5• Inch plywood top) Insulation Plate with Trufast HD (2),equally spaced,staggered center rows W-136 Min.19/32- Elastobase,Elastobase P(poly-film OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c in 4-inch lap and 12-inch o.c in two SBS-SA SBS-SA,APP SA' -60.0• Inch plywood top) N12 (2),equally spaced,staggered center rows SBS-TA,APP-TA W-137 Min.19/32- Elastobase,Elas[obase P(poly-film OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c in 44nch lap and 12-inch o.c in two Polyflex SA Base APP TA j -60.0• Inch plywood top) fl12 (2),equally spaced,staggered center rows TABLE 1G:WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(See Primer Roof Cover(See Table l) MDP(psf) No. Note 1) Jolrit Treatment Base Ply Ply Cap W 138 Min.15/32- (Optional)PG100 None (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS, Inch plywood SBS-SA TA,APP-TA TA,APP-TA -90.0 W-139 Min.15/32- (Optional)PG100 None Po Inch plywood lyflex SA Base (Optlanal)APP-TA APP-TA ! -90.0 Min.15/32- Plywoodjolnts are covered with 44nch wide strips of Elastoflex SAV Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-, W 140 Inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP TA -97.5 Min.15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-141 Inch plywood (Optional)PG300 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA -235.0 W-142 MIn.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Inch plywood (Optional)PG100 place to create continuous bond. Palyflex SA Base (Optional)APP TA APP TA -135.0 Exterior Research and Design,LLC d/b/a Trintty)ERD Evaluation Report P9290.02.08-R17 for FL1654-R19 Certificate ofAuthoriiation R9503 Revision 17:04/18/2016 Prepared by:Robert Nfeminen,PE-59166 Appends i,Page 22 of45 i I