Loading...
HomeMy WebLinkAboutBuilding plan, poolOUTSIDE ANGLE OF REPOSE 6' AND FURTHER =4" THICK WALLS WM3 REBAR II 12" O.C. EACH WAY 3' TO W - 6" THICK WALLS W/#3 REBAR A 12" O.C. EACH WAY 0' TO 3' = S' THICK WALLS W103 REBAR @ 12" O.C. EACH WAY 9K 7f I � ' a m 30Till' 0 W / Y EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: ' SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES "COMPACTION TEST OF THE SACKFILLED MARTIAL ARE PROVIDED AT G.O. OF THE SWIMMING POOL VS-FHP1.0 PERFORMANCE CURVES 0 a w x v— z Y O 4 TM 1 SPEED it 0 F_ 0 10 20 30 40 10 60 70 80 10 100 110 120 130 /4o t10 IN 170 m too no FILTRATION I FLAW GPM - PUMP LOW SPEED • POOL RETURN LINES 2.5" TO FIRST TEE POOL DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 • •• APPROVED WITH THE 2014 FLORIDA BUILDING CODE FOR RESIDENTIAL WITH THE 2014 SUPPLEMENTS AND THE • ANSIIAPSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE • MINIMUM) SUCTION LINES PER PUMP 3 FT, SEPARATION OR SEPARATE PLANES_ • 3 FT. MIN. 3" SUCTION LINE TO PUMP MAX 181 G.P.M. 6 FPS MAX TO FILTRATION PUMP 3" PLUMBING LINES FROM SUMP W/ 3" TEE AREA INCLUDES HATCHED MINUS RIBS AREA OF OPENING = 43.201 IN/SO VELOCITY @ 200 GPM = 1.485 FPS FOR OTHER FLOW RATES SDX VELOCITY = GPM/134.648 AWIWIIM,PWL-� SPP PACAICIS M sob " KLOCIN CALCULATION F. o, EQ EQUIPMENT PAD PER FBC 4101.22(9.2) POOL EQUIPMENT ANCHORED PER FLORIDA BUILDING CODE 2014 & R4501.22 JANDY DECK JET • (5) SPOTTER TILE SET ON THE DIAGONAL 0 TILE STEP EDGES 3 FT ® DEEP N� KITCHEN 18' MIN. ( ENTIRE PERIMETER W.L. JANDY DECK JET • ♦ LED LIGHT SOIL N SOLID C)PPER BOND WIRE V/APPR. ON CLAMIs 8 GAUGE SOLID COPPER (ONE EA:H SIDE WIRE OF POOL 4.OTAL ) I I I I I E Uq IPO-ENTIAL BONDING GRID DETAIL MINIMUM 18" FROM EDGE OF POOL AROUND ENTIRE PER N.E.C. 2011 SEC. 680.26 POOL PERIMETER BURIED (WHERE ADOPTED) 4" TO 6" DEEP S_ WIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE APPROVED WITH FBC 2014WATERLINE I 20' x. 18"� Vac JANDY DECK JET • 30 ft. ♦ 48" HIGH SPLIT RAIL ALUM. FENCE TO MEET CODE W/ (2) SELF -LATCHING GATES SELF - CLOSING. BY OTHERS SEPARATE PERMIT. JANDY DECK SET 10" BACK JET • (TYP.OF4) L ♦ ♦ 4%10" DEEP LED LIGHT �II SKIMMER BULLNOSE BRICK COPING ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE DWELLING TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM TO COMPLY WITH THE FLORIDA BUILDING CODE CHAPTER 4, SECT. 424.2.17.1.9. GREAT ROOM 2X4 @ 24" O.C. CERTIFIED 1/2" LYWOOD SHORING DETAIL HOUSE SLAB JODS OTES E- I- SHOINSTALLED WHENL IS CLOSER THAN E, OR EXCEEDS THE OATIO OF THE ANGLE SHELL DIRT N.T.S. MUST HOLD 35 PSI FOR AT ELECTRICAL DIAGRAM AND NOTE: POOL PUMP MOTOR LOCATED ABOVE LE.:AST 30 MIN. GFI OU.PER 2011 NEC GRADE. PROVIDE SEPARATE CIRCUIT FOR �+ PIPING SCHEMATIC PUMP MOTOR(S)AND HEATER(S)ETC (NO KALE) INO SCALE) R SSUR RAIN TIGHT OUTDOOR NOTE: INSTALL 125V_1.5 FILTER GAUGE LECTRICAL PANEL AMP WEATHERPROOF (SIZED PER LOAD) DUPLEX RECEPTACLE AT TO MAIN SERVICE PANEL IN GFI LEAST 10' AWAY AND APPROVED ONDUIT'SIZEO ouTLEr NOT MORE THAN 20' RETURN LINE PER LOAD) TDOORMME-C K FROM THE INSIDE WALL WIRING TO POOL LIGHT IN OF THE POOL WASTE-), PUMP APPROVED CONDUR PUMP MOTOR UL APPROVED DECK BOX SKIMME FOR DIRECT CONNECTIO NOTES: TO WET NICHE (1) POOL PANEL AND SWITCHES MUST BE AT (2) MAIN DRAIN LEAST 6' FROM THE INSIDE WALL OF THE POOL MIN. X APART mil. ' (2) ALL ELECTRICAL WIRING AND EQUIPMENT / POOL LI HT SWITCH MUST INSTALLED IN ACCORDANCE WITH THE UNDERWATER EITHER INDOOR OR 2D11 EDITION OF THE NATIONAL ELECTRICAL LIGHT OUTDOOR CODE HAIR &LINT APPROVED WIRING IN 1" (3) PROVIDE PROPER WORKING CLEARANCE CATCHER SC BONDING BONDING CONDUCTOR SPACES FOR ELECTRICAL EQUIPMENT AS PER (COMPONENT OF PUMP) HO-26 OF NFPA 70 PAVER DECK BY PHOENIX MASTER BEDROOM MISC. NOTES 1. ALL STEPS AND SMMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED +e" ABOVEPOOL iZMIN #8 GROUND WIRE 7HANDRAIL BONDING DETAIL WHERE APPLICABLE 4B" MAXPER NATIONAL ELECTRICAL CODE WATE DEPTH STEP DETAIL 1. TREAD IS MIN. OF 10"WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. STEP DETAIL N.T.S. 4" MIN. UNDEIWATER' LIGHT SP 10-22 WILL FITTING INSIDE PIPE POOL FI W LEGEND IA) 1. POOL MAIN DRAIN 2.2" POOL SKIMMER LINE 4. 2" VACUUM LINE 5. 2.5" POOL RETURN LINE 6. 1.5" DECK JET LINE EQUIPMENT LAYOUT N.T.S. RECEIV`p WE HAVE REVIEWED THE POOL/SPA PILAN AND APPROVE ALL ELEVATIONS, DEPTHS, AND DIMENSIONS TO BE CORRECT UNLESS OTHER WISE NOTED ON PLAN. • APPROVED WITH THE 2014 FLORIDA BUILDING CODE FOR RESIDENTIAL 51h ED. • AND ANSI/APSP-7 SPECIFICATION MAX. WIDTH 11'-6" MAX. LENGTH 30' MIN. DEPTH 3' MAX. DEPTH V-10" SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION: STOCKPILE TILE: INCLUDED INTERIOR FINISH: GEM FINISH POOL PUMP: 1HP 2-SPEED FHPM --FIL,RAII'V P Z "INSUdPCP/IRfAOPUMPUMP MAKE PER FBC 4101.20 WIT610H LIGHTS: POOL 121 LED A. JANDY 1 HP 2-SPEED SPEED FLOPRO W/APPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. JANDY HEAT PUMP POOL HEATER E. VALVES (TYP) F. JANDY "AQUA -PURE SALT SYSTEM HEATER (GAS) IGNITION SWITCH 3- #12 THHN CU WITHIN %" CONDUIT 2HP JANDY PLUS HP PUMP MOTOR W/ / BUILT-IN OVERLOAD SWITCH W/3-#10 60 AMP POOL PANEL / THHN CU WITHIN 1/2" MIN. CONDUIT W/(3)-#6 THHN CU WITHIN'/4" h,G ELECTRICAL CONDUIT MANUAL MOTOR SWITCH #8 SOLID CU GROUND WIRE TO EXISTING PANEL VARIABLE SPEED FLOPRO PUMP MOTOR Ti W/BUILT-IN OVERLOAD SWITCH W/3-#10 THHN CU WITH4N /." CONDUIT SWITCH S.P.S.T. TOGGLE TIME CLOCK W.P. DISCONNECT (4) POOL LIGHTS (GFI NOT REQUIRED) (1) SPA LIGHT (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O11 NATIONAL ELECTRIC CODE. 2.3412 THHN CU WITHIN %11 MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) ELECTRIC_A__L_DIA--GRAM N.T.S. NOTE: REMOVE GRATE 8 WELL POINT PLUG FROM MAIN DRAIN 8 ATTACH AUX.PUMP LINE WHEN EMPTYING POOL 6"X6"TILE COPING • INTERIOR SAVI NICHELESS GRATE SHALL FINISH LED LIGHT BE SECURED IN PLACE SO WELL POINT THAT TOOLS PIOSDAL4 ARE REQUIRED NO NICHE 1" LIGHT FOR REMOVAL STEEL-TEX FORM CONDUIT R KRAFT WALL UNDERWATER #3 @ 12" O.C.B.W. LIGHT DETAIL THREADE NOTE: FOR DEPTHS (NO SCALE) PLUG REATER THAN 6' ADD 1- 1.5" SCH 40 PVC #3 COVE BAR @ 6" O.C. SLEEVE GRAVELBED TO PUMP 11 TYPICAL WALL SECTION & FILTER: JANDY CS20_0_ CARTRIDGE MAIN DRAIN: POOL (2) SKIMMER (1) RETURNS: POOL (3) DECK JETS (4) VALVED VAC LINE INCL FILL LINE NA_ DISCHARGE LINE TO GROUND JANDY "AQUA -PURE" SALT SYSTEM - INC HANDRAIL NA LADDERNA DIVING BOARD NA SLIDE NA HEATER: JANDY JE2500 HEAT PUMP - INC ELECTRICAL INC POOL PATIO PAVERS BY OTHERS COPING — BULLNOSE BRICK - INC DECK DRAIN NA GALLON CAPACITY -POOL 9,095 GAL.. TURN -OVER RATE 6 hrs TERMITE TREAT INC BARRIER INC MAX WATER VELOCITY 6 ft./s FROM TRUNK LINES TO 8 ft./s SUCTION LINES, 10f)1s_MAX RETURN LINE SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL — 304 SO. FT. 82' 6ENERALHOIEb: JOB NAME: BAKER ADDRESS: 3913 SHORE SIDE DR. LOT 7 TARPON FLATS PERMIT NO.: DATE DRAWN: DECEMBER 1. 2016 DRAWN BY: F. DELROCCO DESIGNER APPROVAL: CUSTOMER APPROVAL: _ SCALE: 1/4" = 1' RPOCOLS, CONCRET INC. 1 ROW OF WATERLINE 3' YVA 1 cicune— ■S" .1 � _ 6" THICK #3 STEEL 12" O/C E.W. 4'-10' LIGH WALLS SHALL F.CCR SLOPE NOT PLACE sLOPes sHSLL sE 6" THICK SLOPE REr�cnADLv u!,I�crrn AND GREATER COL"", ARTICLFs 5.6.1 THAN 11° THRU 5,6.1 - CYCOLAC MAIN DRAIN -*I' X �6' 4 ROM 1 _HALL 30' RAY REINHARD PE # 47041 TYPICAL SECTION THRU POOL 1010 FASTER 1-ILLY LN. (NO SCALE) THESE PLANS AND ALL PROPOSE[ ARE SUBJECT! TO ANY CORRECT REQUIRED BY FIELD INSPECTORS (" : MAYBE NECI:SSARYA ORDER COMPLYWITH AL4APPLICABL� CI ST. LITCTF. rpTN^TY RUILjITNf, TO REVIEWiD FJR MPLLIYCE REVIEW�E�ry E S11WLTutI DATE PLAN§ AND PERMIT MUST BE KEI OR NO INSPECTION WILL BE MAI 6" TYP. FLOOR