HomeMy WebLinkAboutBuilding plan, poolOUTSIDE ANGLE OF REPOSE
6' AND FURTHER =4" THICK WALLS WM3 REBAR II 12" O.C.
EACH WAY
3' TO W - 6" THICK WALLS W/#3 REBAR A 12" O.C. EACH
WAY
0' TO 3' = S' THICK WALLS W103 REBAR @ 12" O.C. EACH
WAY
9K
7f
I � '
a m 30Till'
0 W
/ Y
EXCAVATION INTO THE ANGLE OF REPOSE IS
ALLOWABLE PROVIDED:
' SHORING IS INSTALLED AT EXCAVATION AND SHORING
SHOULD BE SUFFICIENT TO SECURE SOILS FROM
EROSION OR SETTLEMENT
NO UNDERMINING OCCURS OR ENGINEER APPROVED
IF ANY DOES
"COMPACTION TEST OF THE SACKFILLED MARTIAL ARE
PROVIDED AT G.O. OF THE SWIMMING POOL
VS-FHP1.0 PERFORMANCE CURVES
0
a
w
x
v—
z
Y
O
4 TM 1 SPEED
it 0
F_ 0 10 20 30 40 10 60 70 80 10 100 110 120 130 /4o t10 IN 170 m too no
FILTRATION I FLAW GPM -
PUMP LOW
SPEED •
POOL RETURN LINES 2.5" TO FIRST TEE
POOL DETAIL
APPROVED MAIN DRAIN FRAMES AND GRATES
PER V.G.B. ASME/ANSI 112.19.8-2007
• •• APPROVED WITH THE 2014 FLORIDA BUILDING CODE FOR
RESIDENTIAL WITH THE 2014 SUPPLEMENTS AND THE
• ANSIIAPSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE
• MINIMUM) SUCTION LINES PER PUMP 3 FT,
SEPARATION OR SEPARATE PLANES_
• 3 FT. MIN.
3" SUCTION LINE TO
PUMP MAX 181 G.P.M.
6 FPS MAX
TO FILTRATION PUMP 3" PLUMBING LINES
FROM SUMP W/ 3" TEE
AREA INCLUDES HATCHED MINUS RIBS
AREA OF OPENING = 43.201 IN/SO
VELOCITY @ 200 GPM = 1.485 FPS
FOR OTHER FLOW RATES
SDX VELOCITY = GPM/134.648
AWIWIIM,PWL-� SPP PACAICIS
M sob "
KLOCIN CALCULATION
F.
o,
EQ
EQUIPMENT PAD
PER FBC
4101.22(9.2)
POOL
EQUIPMENT
ANCHORED
PER
FLORIDA
BUILDING
CODE 2014
&
R4501.22
JANDY DECK
JET •
(5) SPOTTER TILE
SET ON THE DIAGONAL
0
TILE STEP EDGES
3 FT
® DEEP
N�
KITCHEN
18' MIN.
( ENTIRE PERIMETER
W.L.
JANDY DECK
JET •
♦
LED LIGHT
SOIL
N SOLID C)PPER
BOND WIRE V/APPR.
ON
CLAMIs 8 GAUGE SOLID COPPER
(ONE EA:H SIDE WIRE
OF POOL 4.OTAL )
I I I I I
E Uq IPO-ENTIAL BONDING GRID DETAIL MINIMUM 18" FROM EDGE
OF POOL AROUND ENTIRE
PER N.E.C. 2011 SEC. 680.26 POOL PERIMETER BURIED
(WHERE ADOPTED) 4" TO 6" DEEP
S_ WIMOUTS
WHEN PROVIDED
SHALL BE AT 20" MAX.
BELOW THE
APPROVED WITH FBC 2014WATERLINE
I
20' x.
18"�
Vac
JANDY DECK
JET •
30 ft.
♦
48" HIGH SPLIT RAIL ALUM. FENCE TO
MEET CODE W/
(2) SELF -LATCHING GATES SELF -
CLOSING. BY OTHERS
SEPARATE PERMIT.
JANDY DECK SET 10" BACK
JET • (TYP.OF4)
L
♦ ♦ 4%10"
DEEP
LED LIGHT
�II SKIMMER
BULLNOSE BRICK COPING
ALL DOORS AND WINDOWS PROVIDING DIRECT
ACCESS FROM THE DWELLING TO THE POOL
SHALL BE EQUIPPED WITH AN EXIT ALARM TO
COMPLY WITH THE FLORIDA BUILDING CODE
CHAPTER 4, SECT. 424.2.17.1.9.
GREAT
ROOM
2X4 @ 24" O.C.
CERTIFIED 1/2" LYWOOD
SHORING DETAIL HOUSE SLAB
JODS
OTES E-
I- SHOINSTALLED
WHENL IS CLOSER
THAN E, OR EXCEEDS
THE OATIO OF THE
ANGLE
SHELL DIRT
N.T.S.
MUST HOLD 35 PSI FOR AT
ELECTRICAL DIAGRAM AND
NOTE: POOL PUMP MOTOR LOCATED ABOVE
LE.:AST 30 MIN.
GFI OU.PER 2011 NEC
GRADE. PROVIDE SEPARATE CIRCUIT FOR
�+
PIPING SCHEMATIC
PUMP MOTOR(S)AND HEATER(S)ETC
(NO KALE)
INO SCALE)
R
SSUR
RAIN TIGHT OUTDOOR NOTE: INSTALL 125V_1.5
FILTER
GAUGE
LECTRICAL PANEL AMP WEATHERPROOF
(SIZED PER LOAD) DUPLEX RECEPTACLE AT
TO MAIN SERVICE PANEL IN
GFI
LEAST 10' AWAY AND
APPROVED ONDUIT'SIZEO
ouTLEr
NOT MORE THAN 20'
RETURN LINE
PER LOAD)
TDOORMME-C
K FROM THE INSIDE WALL
WIRING TO POOL LIGHT IN
OF THE POOL
WASTE-),
PUMP
APPROVED CONDUR
PUMP
MOTOR
UL APPROVED DECK BOX
SKIMME
FOR DIRECT CONNECTIO
NOTES:
TO WET NICHE
(1) POOL PANEL AND SWITCHES MUST BE AT
(2) MAIN DRAIN
LEAST 6' FROM THE INSIDE WALL OF THE POOL
MIN. X APART
mil.
'
(2) ALL ELECTRICAL WIRING AND EQUIPMENT
/
POOL LI HT
SWITCH MUST INSTALLED IN ACCORDANCE WITH THE
UNDERWATER EITHER INDOOR OR 2D11 EDITION OF THE NATIONAL ELECTRICAL
LIGHT OUTDOOR CODE
HAIR &LINT
APPROVED WIRING IN 1"
(3) PROVIDE PROPER WORKING CLEARANCE
CATCHER
SC
BONDING
BONDING CONDUCTOR
SPACES FOR ELECTRICAL EQUIPMENT AS PER
(COMPONENT OF PUMP)
HO-26 OF NFPA 70
PAVER DECK
BY PHOENIX
MASTER
BEDROOM
MISC. NOTES
1. ALL STEPS AND SMMOUT BENCH EDGES
WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE
COLOR OF GEM FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT ARE
WHERE DECK RAISED +e"
ABOVEPOOL
iZMIN
#8 GROUND WIRE
7HANDRAIL
BONDING DETAIL
WHERE APPLICABLE
4B" MAXPER
NATIONAL ELECTRICAL CODE
WATE DEPTH
STEP DETAIL
1. TREAD IS MIN. OF 10"WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT
IF MORE THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID
GUNITE 4000 PSI.
STEP
DETAIL
N.T.S.
4" MIN.
UNDEIWATER'
LIGHT
SP 10-22 WILL FITTING
INSIDE PIPE
POOL FI
W
LEGEND IA)
1. POOL MAIN DRAIN
2.2" POOL SKIMMER LINE
4. 2" VACUUM LINE
5. 2.5" POOL RETURN LINE
6. 1.5" DECK JET LINE
EQUIPMENT LAYOUT
N.T.S.
RECEIV`p
WE HAVE REVIEWED THE POOL/SPA PILAN
AND APPROVE ALL ELEVATIONS, DEPTHS,
AND DIMENSIONS TO BE CORRECT UNLESS
OTHER WISE NOTED ON PLAN.
• APPROVED WITH THE 2014 FLORIDA BUILDING
CODE FOR RESIDENTIAL 51h ED.
• AND ANSI/APSP-7
SPECIFICATION
MAX. WIDTH 11'-6" MAX. LENGTH 30'
MIN. DEPTH 3' MAX. DEPTH V-10"
SHAPE CUST ELEVATION T.B.D
FILL FROM EXCAVATION: STOCKPILE
TILE: INCLUDED
INTERIOR FINISH: GEM FINISH
POOL PUMP: 1HP 2-SPEED FHPM
--FIL,RAII'V P Z
"INSUdPCP/IRfAOPUMPUMP MAKE PER FBC 4101.20
WIT610H
LIGHTS: POOL 121 LED
A. JANDY 1 HP 2-SPEED SPEED FLOPRO W/APPR HAIR & LINT STRAINER
B. 1.5" TO WASTE OR TO GROUND
C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE
D. JANDY HEAT PUMP POOL HEATER
E. VALVES (TYP)
F. JANDY "AQUA -PURE SALT SYSTEM
HEATER (GAS) IGNITION SWITCH
3- #12 THHN CU WITHIN %" CONDUIT
2HP JANDY PLUS HP PUMP MOTOR W/
/ BUILT-IN OVERLOAD SWITCH W/3-#10
60 AMP POOL PANEL / THHN CU WITHIN 1/2" MIN. CONDUIT
W/(3)-#6 THHN CU WITHIN'/4" h,G
ELECTRICAL CONDUIT MANUAL MOTOR SWITCH
#8 SOLID CU GROUND WIRE
TO EXISTING PANEL VARIABLE SPEED FLOPRO PUMP MOTOR
Ti W/BUILT-IN OVERLOAD SWITCH W/3-#10
THHN CU WITH4N /." CONDUIT
SWITCH
S.P.S.T. TOGGLE TIME CLOCK
W.P. DISCONNECT
(4) POOL LIGHTS
(GFI NOT REQUIRED)
(1) SPA LIGHT
(GFI NOT REQUIRED)
1. ALL ELECTRICAL TO COMPLY WITH 2O11 NATIONAL ELECTRIC CODE.
2.3412 THHN CU WITHIN %11 MIN. CONDUIT FOR POOL LIGHT (S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER.
4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B)
ELECTRIC_A__L_DIA--GRAM
N.T.S.
NOTE: REMOVE GRATE 8
WELL POINT PLUG FROM MAIN
DRAIN 8 ATTACH AUX.PUMP
LINE WHEN EMPTYING
POOL
6"X6"TILE
COPING •
INTERIOR
SAVI NICHELESS GRATE SHALL FINISH
LED LIGHT BE SECURED IN
PLACE SO WELL POINT
THAT TOOLS PIOSDAL4
ARE REQUIRED
NO NICHE 1" LIGHT FOR REMOVAL STEEL-TEX FORM
CONDUIT R KRAFT WALL
UNDERWATER #3 @ 12" O.C.B.W.
LIGHT DETAIL THREADE NOTE: FOR DEPTHS
(NO SCALE) PLUG REATER THAN 6' ADD 1-
1.5" SCH 40 PVC #3 COVE BAR @ 6" O.C.
SLEEVE
GRAVELBED
TO PUMP 11
TYPICAL WALL
SECTION &
FILTER: JANDY CS20_0_ CARTRIDGE
MAIN DRAIN: POOL (2)
SKIMMER
(1)
RETURNS: POOL (3)
DECK JETS (4)
VALVED VAC LINE INCL FILL LINE NA_
DISCHARGE LINE TO GROUND
JANDY "AQUA -PURE" SALT SYSTEM - INC
HANDRAIL NA LADDERNA
DIVING BOARD NA SLIDE NA
HEATER: JANDY JE2500 HEAT PUMP - INC
ELECTRICAL INC
POOL PATIO PAVERS BY OTHERS
COPING — BULLNOSE BRICK - INC
DECK DRAIN NA
GALLON CAPACITY -POOL 9,095 GAL..
TURN -OVER RATE 6 hrs
TERMITE TREAT INC BARRIER INC
MAX WATER VELOCITY 6 ft./s FROM TRUNK LINES
TO 8 ft./s SUCTION LINES, 10f)1s_MAX RETURN LINE
SKIMMER MIN. FLOW 25 GPM
SURFACE AREA OF POOL — 304 SO. FT. 82'
6ENERALHOIEb:
JOB NAME: BAKER
ADDRESS: 3913 SHORE SIDE DR.
LOT 7 TARPON FLATS
PERMIT NO.:
DATE DRAWN: DECEMBER 1. 2016
DRAWN BY: F. DELROCCO
DESIGNER APPROVAL:
CUSTOMER APPROVAL: _
SCALE: 1/4" = 1'
RPOCOLS,
CONCRET INC.
1 ROW OF WATERLINE
3' YVA 1 cicune— ■S"
.1 � _ 6" THICK
#3 STEEL 12" O/C E.W. 4'-10' LIGH WALLS
SHALL
F.CCR SLOPE NOT
PLACE sLOPes sHSLL sE 6" THICK SLOPE
REr�cnADLv u!,I�crrn AND GREATER
COL"",
ARTICLFs 5.6.1 THAN 11°
THRU 5,6.1 -
CYCOLAC MAIN DRAIN -*I' X
�6' 4
ROM 1
_HALL
30'
RAY REINHARD
PE # 47041
TYPICAL SECTION THRU POOL 1010 FASTER 1-ILLY LN.
(NO SCALE)
THESE PLANS AND ALL PROPOSE[
ARE SUBJECT! TO ANY CORRECT
REQUIRED BY FIELD INSPECTORS
(" : MAYBE NECI:SSARYA ORDER
COMPLYWITH AL4APPLICABL� CI
ST. LITCTF. rpTN^TY RUILjITNf, TO
REVIEWiD FJR MPLLIYCE
REVIEW�E�ry E S11WLTutI
DATE
PLAN§ AND PERMIT MUST BE KEI
OR NO INSPECTION WILL BE MAI
6" TYP.
FLOOR