Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certification for Design Load Compliance
Planning & Development Services Department RECEIVED Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1 53 p F r I 1 ","'I Certification for Design Load Compliance 11 §T. 6."Oe CogD Permitting Project Name: 1 \'PCd UAJ)O 1) Cl [0+- CR 3 Project Address: `Z(.9 Li LP CC \ 1 R.V VV Permit #: Occupancy Type _SR2- Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +19.6 -31.2 Zone 2: +19.6, -54.3 Zone 3: +19.6,-80.2 Zone 4: +34.1; 36.9 Zone 5: +34.1,-45.6 Garage: +24.9,-27.7 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NSA PSF Dock: NSA PSF Deck: NSA PSF Stairs: N/A PSF Fence: N/A PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? Yes X Not Applicable Explain Why Not: ASPECT RATIO <4:1 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design Revised 12/07/2018 Donald J. Nuelle Print Name Cert # & Co. Cert Auth. Nuelle Engineering 52046 11634 SW Rowena Street, Port St. Lucie, FL 34987 Company Name & Address /flz _ ©z LE Copy