Loading...
HomeMy WebLinkAboutEngineering • 0 PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 May 21, 2020 Re: Case# 101514 Dry-In Inspection 8102 Deland Ave. Ft. Pierce, Ff. To Whom It May Concern: Our office has personally inspected the Tri-Built Self Adhering Underlayment (FI# 16058.1 ) self adhered to 19/32" cdx plywood sheathing w/ 8d ringshank nails @ 4" o.c. perimeter and 6" ox in the field at the shingle roof and the Polyglass USA Modified Bitumen Roof System (FL# 1654-1) system W-183 w/ Elastoflex Self Adhering Cap Sheet self adhered to Elastoflex Self Adhering Base Sheet self adhered to 19/32" cdx plywood sheathing w/ 8d ringshank nails @ 4 " o.c. perimeter and 6" o.c. in the field @ the flat roof at the above referenced address and find that all work meets the FBC and FRC 2017, 6th Edition and our engineering requirements. Thank you for your attention to this matter. Sincerel PAUL W CH INC. Paul Welc P.E. FL. Reg. N . 29455 PW:ns