Loading...
HomeMy WebLinkAboutConstruction Plans1 ,, SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMEN??TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BW�'DING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 3'-6" 13'-8" 280 S6" 11'-8" 240 S-6" 10'-0" 200 8'-0" 160 3'-6" TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 13'-8" 1'-101" 1'-104" 11'-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 8'-0" 0'-9" 6'-6- 6 1-0 1, 0'-10" 51" - •VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. OR AT SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)j%44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"xB"x16" 3500LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16"x16" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" j 1900LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-B" WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH TYPE LW-(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0" TO 6" 6'-0' 1936LB I, 11, III, OR IV 1879LB I, II, III, OR IV ill -all SW/DW 6.00/480 0" TO 6" 6'-0' 2558LB I, 11, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 6'-0' 2400LB I, 11, III, OR IV 2400LB I, 11, 111, OR IV 8'-0" SW 4.00/320 0" TO 6" 6'-0" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0" SW 3.00/240 0" TO 6" 6'-0' 1658LB I, 11, III, OR IV 1866LB I, 11, 111, OR IV * LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. RECEIVED DEC 0 8 1020 Permitting DeparILE tment St. Lucie F COPY GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. * LOAD WIDTH OF UPLIFT ON RUNNER ::.LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. TABLE 4A 30" AUGER ANCHOR SPACING -SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 13'-8" 7.00 243 0'-0" TO 3'-0" 10'-0" 11'-8" 6.00 208 0'-0" TO 3'-0" 10'-0" 10 .-0" a r 5.00 -0"�jT"�0, 3' -0 � Y�# 1Y111C0 ,» 8'-0" 4.00 138 0'-0" TO 3'-0" 10'-0" 6'-0" 3.00 104 0'-0" TO 3'-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 20'-0" 10.00 400 0'-0" TO 3'-0" 5'-0" ,� �-� ,y� 2'x2"iGALVANIZEDIMWASHE_R'� 2"x2" GALVANIZED WASHER WITH 1/2" NUT 1/2" THREADED ROD "HIGH WITH 1r/2 NUT r c�9i �,.. a�� '` C3�1G2' THREADED R00 TIONAI:- FOR HIGH SET - EYES BOLTED TOGETHER WITH 1/2"x2" OPTIONAL FOR SET" 1 /2" COUPLER NOTCH "x COUNTERSINK BOLT THRU 2OTT BOTTOM PLATE 1 /2" COUPLE '- ' � = - - [ BOLT & NUT WITH (2)2"x2" GALVANIZED WASHERS (2.000LB SHEAR CAPACITY) -. 1/2"x5" 400 LB. CONCRETE TO 2" BOTTOM �E NAILED 'tt./2px1.2" FORGED EYEBOLT �:.�� `� I cM- �sl a a . :. " MIN. n a �4" WEDGE ANCHOR INTO SLAB THRU 2"x4" P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) _ 4" MIN. I 1d------- - ------ �r _ EYES BOLTED TOGETHEBnWITH 1/2 x2" 'u:T .• ii BI OR IV PAD ITH BOLT &NUT WITH, (2)2 z2 GALVANIZED `- 6d-"'» • -' -< . - BLOCKING AS REQUIRED (SEE TABLE 3). 1/2" x3" 400 LBJ SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH WASHERS (2.000LB SHEAR CAPAGTTY) CONCRETWEDGE ANCHOR CUP OR EQUAL LOCAL CODES AND JURISDICTION LOCAL CODES AND JURISDICTION 30" EARTH „AUGERNCHOR� r _ c (SEE TABLE 1 FOR SPACING) (SEE TABtE'a FQR sPAaNc) -- ¢� SHED WIITiH�SK+VDF SHED WITH SKID SHED WITH 'NO FLOOR' OPTION L TO PAD ®R BL®KK+IN:G ANCHORED TO CONCRETE ANCHORED TO CONCRETE TIE -DOWN DETAILS CODE VERSION FOC 2017 6th Edition, ASCE-7 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE MANUFACTURED6UILDI iC RESIDENTIAL LAWN STORAGE CONSTRUCTION TYPE V-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED Va-200mDh EXPOSURE D ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFlCIENT +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001bs FLOOR DEAD LOAD BPSF FLOOR LIVE LOAD S1D. 75PSF - 125PSF OPT. 'R° RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE No SQUARE FOOTAGE LESS THAN 72o sO.Fi. 1 2017 FBC >>/12/1] MTD 2 GROUND ANCHOR 6' 11. MAX., ANCHOR EXTENSION5/28/18 MTB [n W W W J m O r��CD W Z (n W By: ALL 16 GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 3. REFER TO TIE -DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. M 6/1/18 Sheet: AD-1 OF 1 2018-12-20 TOP LINE ENGINEERING APPROVAL PLAN #SS-B-180-C Side Wall Header Schedule M80C) End Wall Header Schedule (180C) 4 D4 ALUMINUM ROOF SHEATHING Building Width Fasteners w/ strap Size{d} Max. Span NJ{b} Fasteners(each endxc)rep Size Up to14'Wide 1-7k4' S0 0 4-3'x0.131'nails V}� ` _......_...----...._._._....__....._..___........._..._..__.. (each end). 0'-0' MAX. Max. Span NJjb} 2-Tx4"(c) 9'-0" D(d) 1 6 -3• x 0.131' nails t 1-0"x4" 1 6-0" D 3 - 3" x 0 131" nails a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber j co IM r e.' 0 I x4 RUNNERS O W END Vi' TRUSS 2"x4* TRUSS M . D.C. MAX. b NJ - Number of jack studs required to support each end. `--� 4'x4' w2'x4" 8'-0" 1 6 - 3' x 0.131" nails C. Laid flat a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber. d. No Jack studs, but 2x6 studs laid flat. '."""_-""".""i b. NJ - Number ofjack studs required to support each end. � c. Window header for window openings that have more than 50% combined stud wall above T' and below, otherwise use door header schedule. NOTES I. SEE SEE FASTENER SamouLE FOR ARE moilFNrs, .. d. See header details for alternate layouts, i.e. 2-2"x4" or 4"x4" P.T. 2 gE HEADER saHEnuL.TCR� AD"rr L te nor(. ft " a. wR�o�Y HF .. FNVE caM U NED . oR 11ar:E WAu FRA11Nc AeovE e. The header can be attached to the top plate and thus have the combined strength ►xD r3EigM. oD+EWISE REFER To DOOR Imo. CODE INFORMATION equivalent and use the maximum span stated. CODE VERSION FB1 20'�7 � ' �""�-7• MANUFACTURER SUPERIOR SHEDS WALL 5 UUS I i BUILDING TYPE MANUFACTURED BUILDINGRESIDEN GE CONSTRUCTION TYPE V-B I i I i SINGLE 2'x4' � �O HFi1DFF( FIRE PROTECTION NONE I I (aJ 2•x4• �R1E1 1/Y PLYWOOD FIRE SUPPRESSION SYSTEM NONE OR OSB FILLER OR (1),V"- �4W 4OCCUPANCY STORAGE 12'x12. OR ,6'x4• BEr*EEN ALLOWABLE NUMBER OF STORIES 1 '1 " rosHFATHDHc ASWM SS rPEA SECURED 12` MAX. MANuFAcrulms NSIRucnoNs easlc WIND SPEED v ,Eomph HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & EEXPOSURENCLOSURE G (OPTIONAL & DOORS DOOR 6' WIDE OR LESS 4"x4" W/2"x4" ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 IMPORTANCE FACTOR 1.15 G.F.I. �-� ROOF DEAD LOAD 1OPSF NOTES-oPTONAL ELECTRIC ROOF LIVE LOAD 3OPSF OR 30011, POINT LOW OUTLET T r uHE mHNenlar to N -ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLF.FLOOR DEAD LOAD 10PSF �-Li v. "T-S`�u-enHtirz#' SOUR L L -ENCASE IN ALL METAL BOXES. William E. Neary, III FLOOR LIVE LOAD SM. 75PSF - 125PSF OPT. DESIGN PRESSURES CE L 11 SIAP-51, SMI-79, ICC 51BSD40 �(R' RATING OF WALLS• FLOOR, ROOF N/A ROOF +27.8/-94.7 OF FRAMING PLAN WIRING DIAGRAM 10649Oakvie' POirteTerroce GOC MODULES PER BUILDING ALLS/DOORS INDO S +32.6/-29 2 OPTIONAL`` L a, Flarida 34734 1 HURRICANE PROTECTION USAGE Na HURRICANE SHELTER USAGE No MILEx OR ALPINE 255- END *ALL DOOR & WNDOW Ll%'i1TIONS VAi&' SQUARE FOOTAGE 719 SOFT OR LESS GH EQUAL REVISIONS sss111xxx Ilk Q1i.Y67. 2•x4• COOAFt AwNE z' OR DETAIL REV DESCRIPTON DATE BY �oR I / SHEATHING OMPTIo�NS SEE HEADER z' MAX MAx as4 a4• o c DETAIL 71 / g / Tx4 RUNNER_-" ON INSIDE L1_I Dm*n By. 2,4 ENDS WAUUs > / J DOte: g Z 12/12/17 END WALL .-. Seale: N A 0.C. 2x4 SOLE PLATE Z N oriel 44 OMUDS MAX:__ FLOOR FRAMING SS-B-180C L4 901E RATE 2:4 SOLE PUTS LLJ r 1. TO PLANS ARE NOT PART OF THIS PLAN SET AND ARE HOOK ING STU05 SECURED 70 SOLE RAZE fLL-J tJJ J GOVERNED BY LOCAL JURISDICILON. 2- THIS BUILDING IS EXEMPT FROM THE FLC ENERGY CONSERVATION CODE CODE PER SE7CII 1015.22. x x LJ LJ x LJ . LJ AND FLOOR FRAMING WITH GLOW (1ni"�■12' smAP �'/a-1� STANDARD WALL DETAIL OR EQUAL NmE: tvALL T,waNc WEMBBs ARE camNu«,s FROM FOUNDATION SiLL TO ROOF AND A Q g 3. TO TIE— DLTADS FOR PROPER INSTALLATION r�aulRE>MExis m CODE Ans W G" To 13' a vals 13�• FLOOR �ATHN� WITH DOOR & WINDOW OPTIONS SEENSURE CONTINUOUS LOAD PATH. WHERE * NB1sErts ARE O 4. ALLSNDS, RAFTEIM TRUSSES. ETC. ARE 2x4 12 sPF, EXCEPT As NaEm s o- To - 3/4• PLYWOOD NDT caNnNuo SHEET METAL CLAMPS, OR CLIPS GAL,EDI;a� STEEL Of L� U 5. STRUCTURES OVER 400 SO. Fr. WILL HAVE AN ee MINIMUM ELEVATION CROSS—SECTION END ELEVATION 4-x4- P.T. ATrACHED *rrH 124 OR awALFNT. SEE - 3/4• P.T. R.TW000 - 3/4• T&G THAN O0J UNAIL W DOOR 6. GUrrER9 TO EE INSTALLED ON -SILL BY OTHERS THRU LOCAL TYPICAL ARCH FRAME WTfH DOOR TARE 2 FOR ,xrANTm AND - 3/4• P.T. T&G W O ��* 7. ALL WINDOWS AND DOORS 7o MEET THE MINIMUM SPECIFICATIONS SPAaNG. TO:. W z•:<• LAID Fur 2.4 FI.Of](RRG .2" BLOWNC ENO WAL19 g zx6- LAD FLAT 2x4 SOLE RATE FLOOR FRAMNG LJ x LJ LJ AL1F5 s'-o' To 13'—B- ARIFs 6'-0. TO 13'—B• END ELEVATION END ELEVATION A ='i ......li�iii- :i:lllll —•: 111-111111-11r ==111111=€I�' 1 III- � I L� � I� IIIIIIIIIIIII� IIrI� r� rI� IIIIIIIIIIII� I� Ltd L� LTA �;ll II v LL AS PER FLORIDA BUILDING CODE. e o .W,v it AL musstiT CAN BaL . Err- TO HELP uRAL S CURE THESE TABLE Sam 11On1 xi 2 x2 Xi NaA TITS: PROYmED 7HAT 7HE ADDED BEND DOES NOT INTERFERE A E)ITSm) G BRAKES BET OS D THE STRAP. `� • L\C E B'-0' ° ➢ 6' 6' - 6'-D• a' -1C m• - x O- - NSF - Ld'TIpP¢EDm c rOF 0) 4Y LL z • fly i� IMSNINE (4) sDs Ls Sxos w In V / ... •� 2x6 P.T. 2e O.C. TYP. •• OPTIONAL 1261751, o 16' O.C. 7J•:� STATE WT` TYP. M 3/4• T&G PLYBOARID / O •. OF .' 4"W P.T. ATTACHED W+M I �i X(`�•'• F L 0 R I D TABLE 2 FaOR UANITIY AND '�� ` S•••'•......... ••• •• ��\ ��` SPACING. O '' 0 C) MottheW T. Bold'Win P.E. z Florida License #64608 WITHOUT DOOR WITH GARAGE DOOR FLOOR JOIST. SEE SCHEDULE FOR SIZE L;.i (ONLY ON Ei*AUj FLOOR FRAMING PLAN F M Sheet SSB-1 OF 1 WITHOUT DOOR WITH GARAGE DOOR FLOOR JOIST. SEE SCHEDULE FOR SIZE L;.i (ONLY ON Ei*AUj FLOOR FRAMING PLAN F M Sheet SSB-1 OF 1