HomeMy WebLinkAboutProduct Approval, underlayments Florida Building Code Online -cad Page 1 of 4
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
Florida
lovProduct Approval
USER:Public User
Product Approval Meru>Product or Application Search>Application List>Application Detail
r
E.. FL# FL12328-R8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products LLC
Address/Phone/Email PO Box 97
Galena,KS 66739
(417)624-6644 Ext2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL12328 R8 COI TBP14001.4 2017 FBC Eva l Report TAh1KQ
Underlavments final.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4869 2016
ASTM D6380 2003
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtI.aspx?param=wGEV XQwtDgtF2Aezua,rj g... 12/15/2020
Florida Building Code Online Page 2 of 4
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Date Revised 09/29/2020
Summary of Products
FL# Model,Number or Name Description
12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Und2r!a,yments final.pdf
Created by Independent Third Party: Yes
12328.2 ASTM Tile Underlayment Coated organic underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 1I TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva!Report TAMKO
Underlayments finaLpdf
Created by Independent Third Party: Yes
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdF
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.4 Moisture Guard A self-adhering modified bitumen underlayment.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R6 AE TBP14001.4 2017 FBC Eval ReportTAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.5 No. 15 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.6 No. 15 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eva[Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odF
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuad g... 12/15/2020
Florida Building Code Online Page 3 of 4
I
Design Pressure:N/A Evaluation Reports
Other:See evaluation report for limits of use. FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party:Yes
12328.7 No.30 ASTM Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.odf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eva[Report TAMKO
Underlayments finai.pdf
Created by Independent Third Party:Yes
12328.8 No.30 UL Asphalt saturated organic felt
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FLi2328 R8 AE TBP1400i.4 2t71, FBC E_ai_Re rt TAMKO
Underlayments firal.pdF
Created by Independent Third Party:Yes
12328.9 TAM-FELT Alternate to ASTM D 226,Type II underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 II TBP14001.4 2017 FBC Eva]Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.Ddf
Created by Independent Third Party: Yes
12328.10 TW Meta]and Tile Underlayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.pdf
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001.4 2017 FBC Eval ReDort TAMKO
Under UMents finai.gdf
Created by Independent Third Party:Yes
12328.11 TW Under]ayment self-adhering modified bitumen underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL12328 R8 11 TBP14001.4 2017 FBC Eval Report TAMKO
Approved for use outside HVHZ:Yes Underlayments final.DdF
Impact Resistant:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL12328 R8 AE TBP14001..4 2017 FBC Eval Report TAMKO
Underlayments firal.odf
Created by Independent Third Party:Yes
back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.j Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
dick here.
Product Approval Accepts:
' � eCChec
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuar g... 12/15/2020
Cert�cate of Authorization Na. 29824
CREEK17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017)
Manufacturer: TANIKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O.Box 1404
Joplin,MO 64802 i r
(417)624-66441.�`' 1 ` ��
hftii://www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO®ASTM Slate ASTM D 6380,Class M,Type II underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOS ASTM Tile ASTM D 6380,Class M,Type II underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKOS Master ASTM D 6380,Class S,Type IV underayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOS Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard® with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO®No.15 ASTM 'ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOS No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
CTAMKOS No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt '
TAMKOS No.30 UL ASTM D 226,Type II undedayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic•Felt
'TAMKOS TW Metal and Self-adhered,flexible,ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKOS TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4
FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufe:turer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not
specifically addressed herein.
C REE�j TAMKO BUILDING NRODCUTS,INC.
j� TAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. Ali fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO®TW Metal and Tile Underlayment and TAMKO®TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO®Moisture Guard®shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but it no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof Mineral Wood
Asphalt Panels and Surfaced Roll Shingles and Slate Clay and
Underlayment Shingles Shingles Roofing Shakes Shingles Concrete Tile
TAMKO®ASTM Slate Y' N N N N Y
Surfaced Roll Roofing
TAMKOO ASTM Tile N N N N N Y
Underlayment
TAMKO®Master Smooth Y' N N N N N
TAMKO®Moisture Guard® Y N N N N N
TAMKO®No.15 ASTM
Asphalt Saturated Organic Y Y Y YZ N N
Felt
TAMKO®No.15 UL Asphalt Y Y Y Y2 Y N
� Saturated Or anic e
TAMKO®No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Fel
TAMfM No.30 UL Asphalt Y Y Y N Y N
Saturated Organic F61t
TAMKOS TW Metal and Tile Y Y N N N Y
Underlayment
TAMKO®TW Underlayment Y Y N N N N
TAMKO®TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
I
CREEK TAMKO BUILDING PRODCUTS,INC.
TAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufactirer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The undedayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
TBP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Cp TAMKO BUILDING PRODCUTS,INC.
['� K TAMKO Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
`,����ti�a►►►►���'
%' � �ENS R'Fs-i 2017.10.19
_� �•
No 74021� • � ' 12:15:58
/
Cr- _04'00'
STATE OF � -ft
���T• Al Zachary R. Priest, P.E.
Florida, O gan ation No!A E96 1 Registration No. 021
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
I
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.