Loading...
HomeMy WebLinkAboutRESISTO4b'Product A Approval "pr _-, USER: Public User Florida Building Code Online Submit Surcharge stats & Facts Publications Contact us 3Ci5 Site Map L,,ks Searcl ` Pmclg Approval Menu > Product or Ap_plicatfon Search 5 i3cah n List > Appfit Men Detail F.M' FL # Application Type Code Version Application Status comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL2569-R19 Revision Tu 2017 Approved Soprema, Inc. (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819) 478-2400 memathieu@soprema.ca Marc -Etienne Mathieu memathieu@soprema.ca Marc -Etienne Mathieu 1688 Jean-Berchmans-Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext3327 memath ieu CDsoprema.ca Jean -Francois Cote, Ph.D. 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/10/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of independence FL2569 R19 Cnr 2020 01 COX N EMINI=N.pdf Referenced Standard and Year (or Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 UL 1897 2012 1:w flaridabuilding.org/pripr app_Ri.aspx?param=wGEVXQwtDgsKQFEnckBIGBErxlUd3xYIR3WFL46CdQu011ynvE6gkA%3d%3d 1/2 .1., 1s v Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Cade Product Approval Method Method I Option D Date Submitted 04/09/2020 Date Validated 04/09/2020 Date Pending FSC Approval 04/14/2020 Date Approved 06/02/2020 Summa of Products FL # Model, Number or Name p eSCI'IptiOn 2569.1 LTrema Roof Underlayments Limits of Use Approved for use in F€VHZ, No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: -t N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use, 2.) The design pressure noted herein pertains to under€ayment systems used beneath adhesive -set tile systems, Refer to ER Section 5.6.4 for details. Self adhering roof underlayments Installation Instructions EL2569 _R19 ii _20Z0 04 06 FINAL ERE FL2S69-R7 9.pdf Verified By: Robert N€eminen, P.E. PE-59156 Created by independent Third Party; Yes Evaluation Reports EL2569 Rae AE 2QZ4 ()A__ 05 FNAL ER FL25_�9-R . f Created by Independent Tird Party; Yes : ntact Us : ; 2001 &fair Stone RG8d­h!!12_hAM FL 3 399 P one: 50-487-1824 The State of Florida is an AA/EEO smployer. gopyng t 2 o7-2G13 State of FlorEda.:: PrWaty Stat ment :: Ac ssi6ili Statement -- %-- .y of nd Sfiatem t -mail address released in response to a public -records request, do not send electronic Under Floritla law, email addresses are public recgrds. if you do not want your a mail to this entity. instead, contact the office by phone ar by traditional mail. If you have any questions, please contact 850.487.939S, *Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaifs provided may he used for afian a ail address w with the licensee. However email addresses are public record, If you do not wish ko supply a personal address, please provide the Department with an email address which can be made available to the Public. Ta determine If ypq are a licensee under Chapter 455, ES,Personal please click ir_eg. Product Approval Accepts_ FIAN E Credit Ciro! Safe + ]or€debuilding.orgipr/pr app_dtl-aspx?param=WGEVXC2+ tDgsKQFEnekBI08Etxl Ud3xYIR3WFL46CdQuQllynvE6gkA%3d%3d 212 I EM01 etc. Certificate of Authorization #i32455 353 Christian Street, Unit #13 to Oxford, CT 06478 ENGINEER (203) 262-9245 EVALUATE "PEST CONSULT Inc. 1640 ruee Haggerty Evaluation Report S18010.06.09-R17 1540 r Drummondville, Qu6bec J2C SPS Canada FL2569 i?19 (819) 478-2400 ©ate of Issuance: 06/15/2009 Revision 17: 04/06/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E- for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Niemirien, P.E. _ '•' -' - °` •`y= Florida Registration No. 59166, Florida The facsimile seal appearing was authorized by Robert DCA ANEIS$3 6 ,. Nieminen, P.E. on ❑4/o6/202o. This does not serve as an CERTIFICATION 4F INDEPENDENCE,- electronEcatly signed document. I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a 'Financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3, Robert Nieminen, R.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E_ does not have, nor wiil acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nierninen, P-E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEW ETC, LLC "NEMO I etc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards, Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3,1 Pr—_..opertL Standard Year 1504.3.1 Wind Resistance Wind Uplift FM 4474 2011 1507.1.1, 1507.2.9.2, R905.1.1, Physical Properties UL 1897 2012 R905.2.8.2 ASTM D1970 2015 1507.3.3, R905.3.3 Physical Properties FRSA/TRI April 2012 04-12 ( ) Physical Properties FRSA/TRI April 2012 2012 TA5 11Q Accelerated Weathering ASTM D61.63 200$ ASTM p4798 2011 �. REFERENCES: in2ty ERD(TST6049) Examination Wind Resistance Reference Date ERD (T5T6049) ASTM D1970 / TAs 110 (QC) 2778.07.05 07/15/2005 ERD (TST6049) FRSA/TR104-12 (OH) 531370.03.10-1-R1 04/07/2010 ERD (T5T6049) ASTM D1970 (OH) S11150.05.09-R2 10/05/2010 ERD {TST6049) ASTM ASTM D1970 (M5) 537210.11.11 11/09/2011 ERD (TST6049) ll1970 (MS) 53721032.11 12/01/2011 ERD (TST6049) FRSA/TRI 04-12 (MS) 540540.02.13-1 02/19/2013 ERD (TST6049) ASTM D1970(BC) 543530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (QC) 544$70,04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (OH)S4487().04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (MS) 544870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (OH)S44870.04.14-4 04/10/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging 540540.10.14 10/31/2014 ERD (TST6049] 8 S Accelerated Weathering SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Wind Resistance SOPC-SC8520.1404. 04/27/2015 M-D (CER1592) HVHZ Compliance 5OPC-SC14045.05.17-R1 06/07/2017 ICC-ES (EVL2396) 2015 IBC Compliance 18-0329.03 06/28/2018 NEMO (T5T6049) ASTM D1970 / TA5 110 ( QC) ESR-1524 03/01/2017 MEMO (TST6049) Wind Resistance SOPC-SC8970.08.15-111 04/25/2018 N€MO (TST5049) ASTM D4798/D1970 ( OH & MS ) 4-SOPC-18-003.08.18 08/27/2013 MEMO (T5T6049) Tensile Adhesion / Long Term Aging 05/31/2019 NEMO (TST6049) Peet adhesion (existing underlayments) .A.45-SOPC-28-002.05.19.A 4p-DOW-29-SSLAP-01R2 02/10/2020 PRI (T5T5878) ASTM D1970 (M5) 4j-SOPC-19-5SUDL-04.A 03/12/2020 50prema, lnc. (PDM3511) Equivalency Declaration SOP-064-02-01 /03 12/2013 12/03/2015 UL, LLC (QUA9625) Quality Control SA SMOOTH PLY 40 UL, LLC (QUA9625 Quality Control MLA Me No, R27605 05/08/2019 Service Confirmation 07/13/2017 MEMO ETC, LLC Certificate ofquthorizatlon #324s5 5"" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-1117 Soprema Roof Underlayments F1.2569-R19 Revision 17: 04/o6/2020 Page 2 of 8 4. PRODUCT f1ESCRiPTION: Product 4.1 r Lastobond TuTu H-- T �_ 4.2 1 Lastobond Shield 4.3 RESISTO SA SMOOTH PLY 4.4 �40 I_astobond Shield HT 4.5 I Lastobond Pro HT-N 4.6 � Lastobond Pro HT-S 4.7 1 EnviroShield 4.8 Lastobond 195 4.9 Lastobond Eaves Protection Sheet 4.10 Lastobond Eca 4.11 Lastobond Smooth Seal HT 4.12 PrimeSource Grip -Rite mooth Seal HT 4.13 ESISTO LB1236 4.14 PrimeSource Grip -Rite Eave & Valley Protector 4.15 SRS TopShield ICE & " 'HATER DEFENDER 4.16 � RFSISTO LB1244 4.17 1 CDlphene FR GR At€M'D ETC, LLC Certificate of Authorization #32455 Specification ASTM D1970 and FRSA/TRI April 2012 ASTM D1970 ASTM D1970 ASTM D1970 ASTM D1970 ASTM D1970 ASTM 791D 0 AST------- M D1970 ASTM D1970 AST 1 7gDM 0 ASTM D1970 AST�.�.— M D197o ASTM D 9701 ASTM D1970 ASTM 7D 9191 0 ASTM D1970 ASTM D1970 and FRSA/TRI April 2012 Plant(s) Gulfport, MS Drummondville, QC Drummondville, QC Drummondville, QC Drummondville, QC Drummondv€Ile, Qc Drummondville, QC Gulfport, MS Wadsworth, OH Gulfport, MS Wadsworth, OH Drummondville, QC Gulfport, MS Wadsworth, OH Gulfport, MS Wadsworth, OH Gulfport, MS Wadsworth, OH Drummondville, QC Gulfport, MS Wadsworth, OH Drummondville, QC Gulfport, MS Wadsworth, OH Drummondville, QC Gulfport, MS Wadsworth, OH Drummondville, QC Gulfport, MS Wadsworth, OH Gulfport, MS Wadsworth, OH *NEMO I etc. Description self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment self -adhering, woven polyethylene Surfaced, SBS modified bitumen roof underlayment available in two widths; 3G and 45 inch self -adhering woven polyethylene surfaced, SBS modified bitumen roof underlayment seif-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment seff-adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, film surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -Mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, -SBS modified bitumen roof underlaymert self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, fiberglass reinforced, granule - surfaced, SBS modified bitumen roof underlayment 6TH EDITION (2017) FBC NON-HV#Z EVALUATION Soprerna Roof Underlayments Evaluation Report S18010.06.09-R17 iL2569-R19 Revision 17: 04/06/2020 Page 3 of 8 5. LIMITATIONS: NEMO f etc. 5.1 This is a building code evaluation. Neither NEM0 ETC, LLC nor fiabert Nieminen, P.E. are, in an�wa he Designer ofRecord fornyprojectonwhich thisEvaluation Report, flr previous versions thereof, is/was r permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FRC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials [Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced based on this evaluation combined with supporting data for the prepared roof covering. within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approvaf 5.5 Allowable Roof Covers: 5.5.1 11 'if I I]ICU w use oT following Approved the adhesives / underlayment combinations. Underiayment TA6LE 1A: ALLOWABLE TILE ADNESIVE / UNDERLAYMENT COMBINATIONS' Adhesive Lastobornd TU HT '"` upont TILE BOND ICP Adhesives Polyset® AH-160 Florida Product Approval FL22525 FL6332 s Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approvol for Overturning Moment Resistance Performance. MEMO ETC, LLC Certificate ofRuthari,&Ton N32435 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R17 Soprema Roof Underlayments FL2569-R1g Revision 17: 04/06/2020 Page 4 of 9 U(4 5.6 Allowable Substrates: EMO ( etc. TABLE 2: SUBSTRATE OPTIONS Underlayment Primer Substrates Lastobond Shield, Lastobond Pro HT-N, RESISTO SA (Optional) ASTM D41, SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Elastocol Stick, Elastocol Stick plywood, OSB, Southern Yellow Enviro5hield, Lastobond TU HT, Lastobond Eaves Protection Zero Pine (SYP) Sheet, Lastobond 195, Lastobond ECO, RESiSTO 1.131236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO L81244, Lastobond Smooth Seal HT or ASTM D41 structural concrete Grip -Rite Smooth Seal HT Colphene PR GR (Optional) ASTM D41 Plywood ASTM D41 structural concrete Lastobond Shield, Lastobond Pro HT-iV, RE515T0SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Enviro5hield, Lastobond TU HT, Lastobond Eaves Protection Dens Deck Prime; SECUROCK Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, {Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board; Grip -Rite Eave & Valley Protector, TopShield ICE & WATER ASTM D226, Type I or If felt; DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT, Sopra-G; Modified Sopra-G Grip -Rite Smooth Seal HT or Colphene FR GR RESISTO LB1236, Grip -Rite Eave & Valley Protector or Existing sand -surfaced, glass- TopShield ICE & WATER DEFENDER RESISTO EXTERIOR PRIMER fiber surfaced, mineral -surfaced or film -surfaced roof underlayment* * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Havinglurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO L81236, Grip -bite Eave & Valley Protector car TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.6.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix 0, Testing Application Standard TAS 114, Appendix! or UL1897. 5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum codified requirements. For installations under foam -on file systems (Lastobond TU HT only), base sheet shall be attached in accordance with FRSA/TRl April 2012 (04-12) or Section 5.6.5 herein. 5.6.5 Wind Resistance for Underla ment S stems in Foam -On Tile A lications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1.504.9 has already been applied). Refer to FRSA/TRl April 2012 (04-12) or FBC 1609 for determination of design wind pressures. NEMO ETC, LLC Certrfrcate of AuFL25 thorization #32455 6"" EDITION 12©17) FRC NON-HVHZ EVALUATION Evaluation Report 518010.R6.69-R17 69-R19 Soprema Roof Underlayments Revision 17: 04/0612020 Page 5ofa #1 ET #3 #4 ##5 Maximum Design Pressure_. 45.0 ps#: NEmo i etc. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocof Stick Zero or RESISTO EXTERIOR PRINTER Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -Saps. Maximum Desi n Pressure = -67.5 sf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. Maximum Design Pressure = -120.0 sf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded, Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end - laps. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. Maximum Design Pressure = -150.0 sf: Deck: Min, 15/32-inch APR -rated BCX plywood (may be installed C-side up) to meet requirements to satisfaction of Authority Having Jurisdiction. project Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. Maximum Desion Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Supra-G mechanically attached with nails (FBC 1517.5,1) and tin caps (FBC 1517.5.2) spaced 5-inch o.c, at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -taps 5-6.5.1 All other direct -deck, adheres! Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf, NEW ETC, LLC Certificate ofAuthorization #32455 6P EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report 518010.06,09-R17 Soprema Roof U nderlayrnents 112569-R19 Revision 17: 04/06/2020 Page 6 of 8 ut4 5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assem�bblly sshhallll � eet�or exceed that required under FRSA/TR1 April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5•7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, FnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT shall not be left exposed for longer than 90- days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. S.8 Tile Sli a e Limitations (TAS 103 per FRSA RI April: 2012 04 12 When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 3: TILL SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Fiat Slope Max. 10-tile stack 6:�2 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted fiallowed by Stiles high on slope, as shown below) 6:12 I Lastobond TU HT Lugged l Colphene FR GR Flat Max. 10-tife stack Egged 5:12 Max. 10-tile stack 6:12 MEMO ETC, LLC Certificate ofAuthori2ation43245s 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Repart 518010.06.09-R17 5oprema Roof Underlayments FL25613-R19 Revision 17: 04/0612020 Page 7 of 8 6. s:1 6.2 6.2.1 6.3 6.3.1 INSTALLATION: *NEMO .etc. Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stich, Elastocof Stick Zero or RESISTO EXTERIOR PRIMER (if applicable). Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LR1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RE&STO technical support. ­­1 I U rl 1, Lascoponct Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO L61244 or Colphene FR GR: ­­: r utLdiions: Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or FBC Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published requirements. 6.3.2 Tile Applications f Lastobond TU HT or Cal hone FR GR onl Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema Published requirements. For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane, fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1. For foam -on the applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12)_ Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 3 herein, and Soprema published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS. Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements, Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. Q.UALITYAsSURANCE ENTITY: UL, LLC — QUA9625; Q14) 578-3406, k.chanceflor@us.ul.com - END OF EVALUATION REPORT - MEMO ETC, LLC Ceriifrcate ofAuthorimtlon #32455 67" EDITION (2017) F8C NON-HVHZ EVALUATION Evaluation Report S18010.06.09-R17 Soprema Roof Underlayments FL2569-rt19 Revision 17: 04/0612020 Page a of a