HomeMy WebLinkAboutDURATION47/27/2020
Florida Building Code Online
6usiness Professional Regulation
SCIS Home Log In I User Registration I Hot Topics
FI i`i�+a
Product Approval
USER: Public User
Submit Surcharge stats & Facts Publications Contact Us - BCIS Site Map Links Search
product Approvaf Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL10674-R15
Revision
2017
Approved
Owens Corning frti
One Owens Corning Parkway
Toledo, OH 436S9 Y�3
(740) 404-7829
greg, keeler@owenscorni ng,com
Greg Keeler
greg. keel er@owenscorn ing, com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
Mel. sancrantCowenscornig. com
Roofing
Asphalt Shingles
am
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert ].M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL1 674 R15 COI 2019 01 COI N EMINEN €1df
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2015
ASTM D3161
2016
ASTM D3462
2010
ASTM D7158
2011
Equivalence of Product Standards
Certified By
Sections from the Code
https:iffloridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbEYSV%2doQT%2b6w7ahRegICQ8ucR6ixEDL76gG32Q9MA°/a3d%3d 112
7/27/2020
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of products
Method 1 Option D
08/15/2019
08/15/2019
08/21/2019
10/15/2019
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
Shingles and Starters
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles
Limits of use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Installation Instructions
FL10674 R15 11 2019 08 FINAL ER OC ASPHALT
SHINGLES FL10674-R15. df
Verified By: Roberti. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL16 74 R15 AE 2019 08 FINAL ER C ASPHALT
SHINGLES FLjQ674 R15 ndf
Created by Independent Third Party: Yes
back me -
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone; 650-487-1824
The State of Florida is an AA/EEO employer. CQRyrtght 20 7-2013 State f Florida.:: privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The email5
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ham,
Product Approval Accepts:
Credit Card
Safe
https:l/floridabuilding.orgipr/pr_app_dtl.aspx?paraln=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEDL76gG32Q9MA%3d%3d 2/2
R!]
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R10
One Owens Corning Parkway FL10674-R15
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 10: 08/15/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named products) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEW I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10,
Prepared by:
`.r.1r
.r
Robert J.M. Nieminen, P.E, �•_.o_ •r.?'_` The facsimile seal appearing was authorized by Robert
•',�^,;; Nieminen, P.E. on 08/15/2019. This does not serve as an
Florida Registration No. 59.166, Florida DCAANE1983 ";?�.,',;,;;;',`.� �''`
electronicallysignad document.
CERTIFICATION OF INDEPENDENCE:
I. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02018, NEMO ETC, tLC
ONEMOJetc.
ROOFING SYSTEMS EVALUATION:
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
Owens Corning Asphalt
Roof Shingles, as produced by Owens Corning, have
demonstrated compliance
with the following sections
of the fish Edition (2017) Florida Building
Code and Florida
Building Code, Residential
Volume through testing in accordance with the following Standards.
Compliance is
subject to the Installation
Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, R905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2011
Entity
Examination
Reference
Date
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI(TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
4.1 ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SIBS modified bitumen starter strip,
nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALT SHINGLES:
4.2.1 Classic' and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire' are fiberglass reinforced, 4-tab asphalt roof shingles. Meets ASTM D3462.
4.23 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition' Duration' Designer Color Collection,
TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 Hip & RIDGE SHINGLES:
4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdge® Hip & Ridge
Shingles and WeatherGuard' HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC, LLC Evaluation Report 037940.02.11-R10
Certificate of Authorization #32455 61H EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 2 of 10
ONEMOIetc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product,
554 Wind Classification:
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FiBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
UP to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip
& ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2,6.1 to
ASTM D3161, Class F, indicating acceptable use in all wind zones up to VaSd = 150 mph (V,lt = 194 mph). Refer to
Section 6 for installation requirements to meet this wind rating.
5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2,5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Felt Mderiayment —Deck
c. Self -adhered
Weathe$ocka
`_. undesiayment
Drip edgo
- Nails located
' 2"-3" horn can
/Self-sealing
Irrs
S.taT-rfar SQIp
amosive
shingle with
_ - positioned along care
—•,
6"removed
Starter Strip shingle overhangs eaves and rakes Y!`—;a"
Figure 1: Minimum Nailing, Starter Strip
FeK,.,d,�avn•em —neck sajadharec
- undn�lagmenkl
I
t.
Drip — Or iedse
_ �ra�k�sated
.� 2a 3rmn enre
kssca�grst SW, Strip&a $eiccaling aeteaire
vegh 6'renrned - p�7nonetl aEang acre
Start. stnp Plus overhangs eaves and rakes 714"-3W
Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 3 of 10
ONEMOjetc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Underlayment
Drip edge
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire' shingles require minimum five (5) nails per shingle.
➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Classic" & Supreme:
Normal Mansard or Area pare
Wind Areas High Wind desvanes y
Area pare vientoo nornfales Areas vientos fuarles
1" (A) 1, r1• Z• SBl f 2" V,
1f' 9T•P-r
5" Exposure
Expos;eMn
Figure 4: Minimum Nailing, Classic & Supreme
(Standard Size)
Normal Mansard or Area parrs
Wind Areas High Wind deovanes
Area pare vientos normafea Gross vientos ivarreYs
112 fAl' 1�� �1• 2 lBl �^ f•�i
5 518" Exposure
Exposision
Figure 5: Minimum Nailing, Classic & Supreme
(Metric Size)
NENIO ETC, LLC Evaluation Report 037840.02.12-1110
Certificate of Authorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 4 of 10
6.3.1.2 Berkshire®:
Sealant strip
La trra de s0ador
V
Figure 6: 5-Nail Pattern, Berkshire
MEMO I etc.
Figure 7: 6-Nail Pattern, Berkshire
Seala nt strip
La tira de settador
t3 yt' 8112,
t„
r
t
i ! r
2 Asphalt rootingcement
Cemeota de techo de astab
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02,12-1110
Certificate ofAutharization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 5 of 10
ONEMOjetc.
4�6 .3-1.3 Duration® TruDefinitione Duration Duration® Premium Cool & TruDefinition® Duration' Designer Color Collection:
4-Nail Fastening Pattern
SureNWIG fastening area width
Nall, Typical
12"—'E 12" 1rr
aCrueti.g3e uar a ®�,,.znssu!trmasn� • �7�ns^-arninesaerJi:�+
•
6-118'"
expos
Figure 9: Standard 4-Nail Patte ��
6-Nail Fastening Pattern
SureNali® fastening area wiefth
Nail, Typical
1 12" 12" 1»
•�lvens C g
— -
_._.... [j7
...,.>s'n� svaap a Prim, Corning Sumti� a .,-- •
6-tJli" F�.Sjgre
expospreL7
Figure 10:
Fastening for Slopes Greater Than 21:12
5ureNai10fastening area width
r Nail, Typical
! I 12"
iTrrens Cbmmp SureyaA • ans SSllufo]ss�axtr j j
Four 1" Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern, Duration
NEW ETC, LLC
Evaluation Report 037940.02,12-RlO
Certificate ofAuthorizotion #32455 6"" EDITION (2017) F8C NON-HVH2 EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019
Page 6 of 10
6.3.1.4 TruDefinition`Oakrid e® Oakridge`K:
4 Nail Pattern
Estluema can 4 clavos
V
ice... 12" --+�
I 5618" Exposure _V"
Exposicidn de 6618pulig. Nails
clavos
f�— 12" —71i
5 518" Exposure I
ExposWdn de 5glepufg.
Figure 12: Standard 4-Nail Pattern, Oakridge
6 Nail Pattern
Esquema con 6 clavos
1"
Imo- �° -�►i
5 518" Exposure Nails
Cfavos
Expusfcf6n de 55/8pufg.
1"
r'r— 12°
5 51S" Exposure '
Exposici6n de 5 618 ping.
Figure 13. 6-Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
SUIeNajf�511111 ,garea 11tlh
Nail, Typkal
12"
u5u'et+ad � �n50uuw]swmO - •fMtnsC'�n�n�5ure1h3�
8-7fe" 5.5rg••
aa�sun
.2..
Four T" Spots of Asphalt Roofing Cement
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
IRNEMOjetc.
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate cfAuthorization#32455 6'" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 7 of 10
6.3.1.5 WeatherGuard" HP:
x1i9 UAW
5 5r$- E7611�'168
E 6iFde 5 5A3 pu4
5 5i8" fxnq sm
590rz66ft 4® 5 M ping.
Figure 15: 6-Nail Pattern, WeatherGuard HP
6 Nal Pattern
Esquersa con 6 clavos Nail 6 1i8" from botfirm
Of Shingle
Clave a 6 VS ppuig. de is
5 5V, Exposure 6 Fasteners parts inferior de. la teja
Expposicinn de 5 5t8 pui.g. 6 sujetadrlres
Four 1" Spots of Asphalt Rmof Gera -ant
Cuatro pvn tos de cemento de ferho da asfatfo de 7 prtlgada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
f0NEM0 I etc.
6.4 HIP & RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge° Hip & Ridge Shingles with Sealant require
minimum two (z) nails per shingle.
➢ WeatherGuard" HP Hip and Ridge Shingles and ProEdge" Hip & Ridge Shingles require minimum four (4)
nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate OfAutharization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1315
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 8 of 10
ONEMOjetc.
6.4.1.1 Berkshire"Hip & Rid a with Sealant and DuraRidge® Hi & Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
Di€eccion del viento predominante
Nails
Ciavos
I
� A I
I I I I
I I
8 Exposure
Ezposic* di 8 P
a
rigure Li: isometric view, Berkshire and DuraRidge
6.4.1.2 WeatherGuard'9 HP Hip & Ridge Shingles:
Fig. A 4
PrevaIIIng Wind
— Direction fy
Nails A
q4
A
I I
A
f I j I
# +
-Exposure �I
F'Sule L:I; isometric view, weatherGuard HP Hip & Ridge
Fig. B
Top View
Vista superior
4
25/a'
Nail
clavu
• Owens Coming SureNaii' •
1
$
I
�Iw
cIv
Y f V
ai I c
UI�,
I
I
rigure its: Plan View, Berkshire and DuraRidge
Fig. C Hip &Ridge Shingle Fastening
To p V lets
Nails Naps
7„
2" 2„
t E �•
�^ Exposure
12 � �
FigUre 20: Plan View, WeatherGuard HP Hip & Ridge
MEMO ETC, LLC
Evaluation Report 037940.02.12-R10
Certificate ofAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Page 9 of 10
6.4.1.3 ProEdgeO Hip & Ridge Shingles
Prevailing
Wind Direction Sealant Satre
41*-"'— 6" Exposure
Fasten 71j."
Cover Exposer!
Fasteners with
Reat Cement
Figure 21. Isometric View, ProEdge
ONEMOletc.
Standard
Fastening
Pattern
1
t?" � sealant
6" Exposure
Figure 22: Plan View, ProEdge
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / 11905.2.6.1.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3
QA requirements.
PRI Construction Materials Technologies, LLC— QUA9110 ; ial3l 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
MEMO ETC., LLC Evaluation Report 037940.02.12-1310
Certificate o}Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1s
Owens Coming Asphalt Roof Shingles Revision 10: 08/15/2019