Loading...
HomeMy WebLinkAboutNOA; Series EL200 Aluminium Horizontal Rolling Window - L.M.I• �� Digitally signed by Asghar Asghar J. Fathi, J. Fathi, AA001 6049 MIAMI-DARE AA0016049 Date: 2020.04.2011:08:0711 DEPARTMENT OF REGULATORY AND BOARD AND CODE ADMINISTRATION NOTICE OF ACCEPTANC E.S. Windows, LLC 3550 NW 49" Street Miami, FL 33142 -04 00 0 WSWCOMPLIANC T. LUCIE COUNTY BOCC MIAMI—DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 T (786) 315-2590 F (786) 315-2599 www.miamidade.Qov/economy SCOPE: This NOA is being issued under the applicable rules and regulaI:' Hofconstructionmaterials. The documentation submitted has been reviewed and eO a County RER— Product Control Section to be used in Miami —Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami —Dade County Product Control Section (In Miami —Dade County) and/ or the AHJ (in areas other than Miami —Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "EL200" Aluminum Horizontal Rolling Window - L.M.I. APPROVAL DOCUMENT: Drawing No. W16-86, titled "ES-EL200 Horizontal Rolling Alum. Wdw. (L.M.I.)", sheets 1 through 11 of 11, dated 12/19/16, with revision C dated 01/12/18, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Barranquilla, Colombia, model/series, and following statement: "Miami —Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami —Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is - displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.17-1114.06and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 18-0221.03 Expiration Date: January 19, 2022 Approval Date: May 10, 2018 jl/��8 Page 1 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBNIITTED 1. EVIDENCE SUBNQTTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No:16-0617.04) 2. Drawing No. W16-86, titled "ES-EL200 Horizontal Rolling Window Alum. Wdw. (L.M.I.)", sheets 1 through 11 of 11, dated 12/19/16, with revision B dated 09/27/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC, and TAS 202-94 5) Large Missile Impact Test per FBC, TAS 201-94 6) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-16-007, dated 12/08/16, signed and sealed by Constantin Bortes, P.E. (Submitted under NOA No. 16-0617.04) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51h Edition (2014), dated 06/10/15, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.16-0617.04) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic: Resources (RER). Manuel Per Vam* P Product Control Er NOA No. 183 Expiration Date: January 19, 2022 Approval Date: May 10, 2018 E-1 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayer" dated 12/28/17, expiring on 07/04/23. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Co. (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. 4. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Co. (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. F. STATEMENTS 1. Statement letter of conformance to FBC 51h Edition (2014) and FBC 61h Edition (2017), and of no financial interest, dated 09/25/17, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1114.06) 2. Statement letter of conformance, complying with FBC 5th Edition (2014), dated 12/08/16, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 16-0617.04) 3. Statement letter of no financial interest, dated 12/08/16, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.16-0617.04) 4. Addendum letter, issued by Black -water Testing for Test Report No. BT-ESW-16-007 dated 12/15/16. (Submitted under NOA No.16-0617.04) 5. Distributor Agreement, signed by Carlos Garcia and by Evelyn Daes. (Submitted under NOA No. 16-0617.04) 6. Laboratory compliance statement for Test Report No. BT-ESW-16-007, issued by Blackwater Testing, Inc., dated 12/08/16, signed and sealed by Constantin Bortes, P.E. (Submitted under NOA No. 16-0617.04) 7. Proposal No. 16-1228 issued by the Product Control Section, dated 11/16116, signed by Manuel Perez, P.E. (Submitted under NOA No. 16-0617.04) F. OTHERS 1. Notice of Acceptance No. 16-0617.04, issued to ES Windows, LLC for their Series "BL200" Aluminum Horizontal Rolling Window - L.M.I., approved on 01/19/17 and expiring on 01/19/22. Manuel wre&,1P.E. Product Contro Exainer NOA No.-0221.03 Expiration Date: January 19, 2022 Approval Date: May 10, 2018 E-2 E.S. Windows, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED: 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W16-86, titled "ES-EL200 Horizontal Rolling Alum. Wdw. (L.M.I.)", sheets 1 through 11 of 11, dated 12/19/16, with revision C dated 01/12/18, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Blackwater Testing, Inc., Test Report No. BT-ESW-17-007, dated 10/24/17, signed and sealed by Constantin Bortes, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources, (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflez CP - Saflez and Saflez HP Composite GlassjInterlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflez Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. None. 1. Notice of Acceptance No. 17-1114.06, issued to ES Windows, LLC for their Series "EL200" Aluminum Horizontal Rolling Window - L.M.I., approved on 01/11/18 and expiring on 01/19/22. Manuel Pe z, .E. Product Control xam' er NOA No. 1 -0 1.03 Expiration Date: January 19, 2022 Approval Date: May 10, 2018 E-3 72 15/16" FRAME WIDTH (3) ANCHORS 19" MAX 7„ MAX AT MTG. STILE ENDS HEAD—] AT 5" O.C. HEAD/SILL CORNERS _ 4 I II �i _AL___ II /, II F /• 6 F- 00 __ z _ ^ o => w Z Ld 0 II II ----��---- - II I it I� II II I B FALSE MUNTINS ¢ (SURFACE APPLIED) MAY BE USED D 11° ¢ SILL 32 11/16" 32 11/16" D.L. OPG. D.L. OPG. 36 9/16" (3) ANCHORS VENT WIDTH AT MTG. STILE ENDS AT 5" O.C. TYPICAL ELEVATION FLANGE FRAMES ES—EL200 HORIZONTAL ROLLING ALUMINUM WINDOW (L.M.I. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION NOA WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 72 15/16" FRAME WIDTH (3) ANCHORS MAX. AT MTG. STILE ENDS`7" AT 5" O.C. A Fr HEAD/SILL CORNERS 7 it �1 / I C� CV 200 Ld Ip Z � wLO o II II ---11---- ---�--- > n l II II iI I B 7 32 11/16" D.L. OPG. 36 9/16" VENT WIDTH I I 11" MAX. SILL 32 11/16" D.L OPG. it V o�¢ (3) ANCHORS AT MTG. STILE ENDS AT 5" O.C. TYPICAL ELEVATION FLANGE FRAMES WITH FLUSH ADAPTER MAXIMUM .DESIGN LOAD RATING = + 65.0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) — 65.0 PSF MTG. STILES WITHOUT REINFORCING MAXIMUM DESIGN LOAD RATING = + 80.0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) — 90.0 PSF MTG. STILES WITH REINFORCING OPERATING VENTS CAN BE 1/4 TO 1/3 OF WINDOW WIDTH MAX. D.L. OPG. FOR FIXED LITE NOT TO EXCEED 12.7 SQ. FT. FOR ALTERNATE SIZE UNITS MAX. FRAME AREA OF WINDOW NOT TO EXCEED TESTED FRAME AREA OF 31.46 SQ. F. 72 15/16" FRAME WIDTH (3) ANCHORS 6„ MAX AT MTG. STILE ENDS EAD/SILL � AT 5" O.C. :ORNERS \ 8 / — 12" MAX. E _C'4_Co0 La 00 'n f Lo w 'n o II I ---11---- I - — --ji �— --IT-- > w II I� II II 12" SILL 32 11/16" 32 11/16" D.L. OPG. D.L OPG. 36 9/16" (3) ANCHORS VENT WIDTH AT MTG. STILE ENDS AT 5" O.C. TYPICAL ELEVATION FLANGE FRAMES WITH FIN ADAPTER THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED as complying with the Florida Building Code 1• 0 Acceptance )\fo 4pifationDate 4622 `\11t11i11///�/ •����11 � . Q�GI10 �''�. 70592 • �y 44iE OF ^ •�� O�IDfA.•°'�0�� V W w to I Z O t.. W Q m N d a ,� 0 �y o ii A 0 U 0 N IL W at: LL O UNti v ou;� p'Oro o p iL � O0�rr : O N Q W ::) LL ILLI ztn� O J02 m z V) � QLLI 0)- v pp N L0 in I M J Q o � M Z .... J J ILL]-J Ld IY z[n 4 N O°-M u' af: Cl 00 = Z�J o w Now W wM �c o T A O N \ H O U t drawing no. W16-86 sheet 1 of 7" MAX HEAD/SILL CORNERS FALSE MUNTINS (SURFACE APPLIED) MAY BE USED 110" FRAME WIDTH (3) ANCHORS AT MTG. STILE ENDS \ .C.7 --` 19" MAX. AT 5" O HEAD - tl --- 1= /-_ II�II II II II II II I� II II II 4 4 MAX. SILL 32 11/16" 32 11/16" 32 11/16" D.L. OPG. D.L. OPG. D.L. OPG. 36 9/16" 36 9/16" VENT WIDTH VENT WIDTH TYPICAL ELEVATION FLANGE FRAMES of �of cn o U (3) ANCHORS AT MTG. STILE ENDS AT 5" O.C. (3) ANCHORS 61. MAX AT MTG, STILE ENDS HEAD/SILL AT 5" O.C. CORNERS A 110" FRAME WIDTH 7" MAX. (3) ANCHORS AT MTG. STILE ENDS AT 5" O.C. 110" FRAME WIDTH (3) ANCHORS AT MTG. STILE ENDS \ AT 5" O.C.7 --` 19" MAX. HEAD I/"I _ LL___1 _ II�II II II II I II II II II - Tr--- �- ,I 12" MAX. HEAD 7 MAX. SILL 32 11/16" 32 11/16" 32 11/16" D.L. OPG. D.L. OPG. D.L. OPG. 36 9/16" 36 9/16" VENT WIDTH VENT WIDTH TYPICAL ELEVATION FLANGE FRAMES WITH FLUSH ADAPTER V w co co I 10 Z °N° i M J i M Q W � IL ,� O Mood 0 U aLiu N XX Q; O F LL O �Nti 0 c' uP � 0'o>m o 0IL0a xx O °��0 1 O Q m W Z O N M� LL WV)LL-0 .: (5W< QWo�� 130 J N 0] v 10 \ Z ,n 0 3:: 0 J 0 z v J a J 1,.1 zin to C', N O�� m = Z�� `O LL- o Z o w L0 Q w w W e%j F-. �Jl 1 MAXIMUM DESIGN LOAD RATING = + 65.0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) - 65.0 PSF MTG. STILES WITHOUT REINFORCING II Il._�� II /� 6 N N m W N a IL _ --- TI- rt =_ __ ---ter- T== MAXIMUM DESIGN LOAD RATING = + 80.0 PSF o _ \ _ I I I I I I II a (FOR SIZES SHOWN ABOVE OR SMALLER) - 90.0 PSF z z z N LID°o z J I __1L___ I' I __1L_—_ II W MTG. STILES WITH REINFORCING � --------- ---�---- I -- N Q N O O O z II I I II I I a OPERATING VENTS CAN BE 1/4 TO 1/3 OF WINDOW WIDTH z z II I' II I' MAX. D.L. OPG. FOR FIXED LITE NOT TO EXCEED 12.7 SQ. FT. --fl----T- -Tr- SIZE UNITS AREA OF WINDOW vi °� r` n m FOR FOR ALTERNATE MAX. FRAME II �I NOT TO EXCEED TESTED FRAME AREA OF 47.36 SQ. FT. N o 0 0 0 a m o CD `\\\\Illllp/l �` Do (3) ANCHORS AT MTG. STILE ENDS AT 5" O.C. Cn 8 MAX. Z lCY SILL DO , N 4 F ° 0.705�� 32 11/16" 32 11/16" 32 11/16" PRODUCPREvism i3 ✓ j �,. ` = m as complying with the Florida D.L.D.L.= W OPG. D.L. OPG. D.OPG. Building Code 36 9/16" 36 9/16" Acceptance No 1-02%1.fis ®S OF = �q2�� drawing no. VENT WIDTH VENT WIDTH F-xp ti Date �2 TYPICAL ELEVATION By �� ` ®����'`����`� W16-86 FLANGE FRAMES WITH FIN ADAPTER Mi i Prodect omro ,,����till j�\\sheet 2 of 1 1 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' OR .090" Interlayer SentryGlas By 'Kuraray America, Inc.' OR .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .075" Interlayer Saflex CP With PET Core By 'Eastman Chemical Co.' r1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' OR .090" Interlayer SentryGlas OR 'Kuraray America, Inc.' .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .075" Interlayer Saflex CP With PET Core By 'Eastman Chemical Co.' r-1/4" HEAT STREN'D. GLASS 1/8" TEMP. GLASS 3/8" AIR SPACE HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By Kuraray America, Inc.' OR .090" Interlayer SentryGlas By 'Kuraray America, Inc.' OR .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .075" Interlayer Saflex CP With PET Core By 'Eastman Chemical Co.' —1/8" HEAT STREN'D. GLASS 1/8" TEMP. GLASS SILICONE SILICONE SILICONE w DOW CORNING 795 w FF- DOW CORNING 795 W4DOW DOW CORNING 795 W Z m DOW CORNING 983 DOW CORNING 2400 z m DOW CORNING 983 DOW CORNING 2400 z mDOW CORNING 983 CORNING 2400 Z m is (HOT MELT) N is (HOT MELT) (HOT MELT) N N ilN CD E o 0 E9 w W w w w w M2 M2 M3 GLASS TYPE ' 1' 5/16" OVERALL LAM. GLASS NOTE: GLASS CAPACITIES ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05—DEC-219 GLASS TYPE '2' 7/16" OVERALL LAM. GLASS GLASS TYPE '1V 7/8" OVERALL INSUL LAM. GLASS GLAZING OPTIONS 5/16" & 3/8" AIR SPACE CONSISTING OF: SPACER: 'HELIMA' LOW PROFILE ALUMINUM SPACER BY 'LINGERMANN GMBH' AROUND THE PERIMETER OF THE GLASS. PERIMETER SEALANT: SILICONE DOW CORNING 791 GE 2000 5/16" AIR SPACE r-1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB OR ,Kuraray America, Inc.' .090" Interlayer SentryGlas By Kuraray America, Inc.' OR .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .075" Interlayer Saflex CP With PET Core By 'Eastman Chemical Co.' —1/4" HEAT STREN'D. GLASS SILICONE DOW CORNING 795 DOW CORNING 983 DOW CORNING 2400 (HOT MELT) GLASS TYPE '2i' 7/8" OVERALL INSUL. LAM. GLASS PRODUCT REVISED as complying with the Florida Building Code Acceptance Niel E :Fall Date IO2/1 By Miam ade Product Cow �` r=D 12 20 70592 e M 9 iEOF o° fj y.00 VW I to z �' O I- Z °�'' N a w a Q2 " M IL a O 0' 0 0 0 O � N �GF O �yh p�0 o O IL0C 4 O NH I aIr W�°" Z0 CD m Z M W a Lu0) 1 �I T N F¢ \ T m 2 U y O U drawing no. W16-86 sheet 3 of 1 1 1BY TYPICAL ANCHORS WOOD BUCK I SEE ELEV. FOR SPACING e d ° o. a EDGE. DIST." ° cG. ° °, . M16 O E14m;A M14 TYPICAL ANCHORS SEE ELEV. = FOR SPACING O 0 w H 2 W II II II O = z w of O O W S H o N 0 3 0 N O = m O OPTIONAL TO SWEEP LATCH OPTIONAL TO SPRING LATCH J WEEPHOLES: W1 = 1-1/2" X 5/16" WEEPHOLES AT 5-1/2" FROM EACH END ' M16 M5 D E2 I M5 E3 M16 M16 v=i I � � M9 I M9 .a Qd ° • �_ 4°' •: • ::: ; < . EDGE DIST. `� _ o D YV1 :4 .' ° �. e to FOR WINDOWS WITHOUT Q. °• E15 SILL RISER LIMIT MAX. I .a EXT•(t) LOADS TO 65.0 PSF n $ e W1' TYPICAL ANCHORSI FOR WINDOWS WITHOUT v SEE ELEV. 1� c SEE ELEV. E15 SILL RISER LIMIT MAX. FOR SPACING WOOD BUCK ^ FOR SPACING EXT.(+) LOADS TO 65.0 PSF EDGE DIST. W ro M�ft 00 t0 Z O Z o� I-q� a Iy W a,. ii OOUao U 0;N km� na. 0 VNn v p Lu ei Cf0>mIt 0 p a0a G OCD �a-i- Wa ZIn -o it W 01 rL FW- L0 I 00 to 0 O 17 J tj a J �` W 0_ rn 0 00 CD Z � J CD Z i 0 O0 a PRODUCT REVISED v as complying with the Florida o 0 0 Building Code 11111 111 g / i Los ¢ m c� Acceptance No 1$-�Z2i • �� ��,, Lu E ti n Date �� • °A4f a � m By ERI& q� �� 0) 0 0 Or 1 ' Dade GdLLCt "tr �N A r 0592 c,� O y 'v 9 U ®'• A?E OF °, � drawing no. ORID�0�W 16-86 sheet 4 of 11 ULJ 4. W ��---=—= = — == =----; CIO � I METAL I I MIAMI—DADE COUNTY APPROVED I I CO STRUCTURE j 1 MULLION & MULLION ANCHORS I I 3 EDGE DIST. I SEE SEPARATE NOA 11 Z 1 �I O F M N tSEE ZI-O 0 0 0 NWm 7 YF� U. ONM u; � o>M C LTYPICAL ANCHORS AL ANCHORS OSEE ELEV. ELEV. 0 co FOR SPACING FOR SPACING Z O co N aW=u.� LLz0E aWc � J co O 1 co M � co J � Q O V, M WOOD BUCKS AND METAL STRUCTURE NOT BY E.S. WINDOWS o J MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM J AND TRANSFER THEM TO THE BUILDING STRUCTURE. z In to oN �O °' L' EE p�,� 1 m = Z3i_j `O TYPICAL ANCHORS: SEE ELEV. FOR SPACING o _ 0 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) w Lo INTO 2BY WOOD BUCKS OR WOOD STRUCTURES A w 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) W m in in DIRECTLY INTO CONCRETE OR BLOCKS `n b D P 1-1/2" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ° ~ zo 0 �-- o 1-1/4" MIN. EMBED INTO.BLOCKS (JAMBS) U = < _ U QQ U 1/4" DIA. TEKS OR SELF DRILLING SCREWS (GRADE 5 CRS) a) z a- Z INTO MIAMI—DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) n n C r N (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE 0 N ALUMINUM: 1/8" THK. MIN. (6063—T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) ``�����1 A •• (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) i �� - TYPICAL EDGE DISTANCE• .��� ®Ori INTO CONCRETE AND MASONRY = 2-1/2" MIN. — Os92 PRODUCTREVISED — _ m a INTO WOOD STRUCTURE = 1 " MIN. as campiying Mth die Florida 2 o INTO METAL STRUCTURE = 3/4" MIN. Building Code p `" � � .: ` Acceptance Nolp— 212% UZI ®'. of �2q drawing no. WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. Exp' ti Date % ��a'°. ,P g. ,° CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. ��®° �\ W 6—$6 C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. Mi ade Product Co oj/� ,��� (sheet 5 of 1 j 1 /4" MAX. SHIM TYPICAL ANCHORS SEE ELEV. FOR SPACING 1 s W W M0311110301103 � METAL STRUCTURE O 1 /4" MAX_ FOR SPACING OREINFORCING O E16 AS REQD. 1/4" MAX. SEE ELEVS. SHIMS ` M8 a. •' TYPICAL ANCHORS SEE ELEV. FOR SPACING 4 a l — a II I J L _ ° a. ..r . .. .... ------ -_--- _-_--_-_- ==---- LJ M5 M17 •• °.a . • d • D.L. OPG. ° 1BY WINDOW WIDTH WOOD BUCKS WINDOW WIDTH XO LAYOUT OX OPPOSITE O MIAMI—DADE COUNTY APPROVED MULLIONSEE SEPARATE NOA r_---,, �I I� II II I I �I II I I I I I' II P5 TYPICAL ANCHORS SEE ELEV. FOR SPACING - ANCHORS EV. 'ACING Vw c° 00 Z 0 Z a M N QI F 2 . N 4 Qa �i 0 �y O li O p ` p U 0 W N O gym C� 'c u; .� Q'O>M o 0 aco 0 NN2 Ix 0 W=LLa Z OE a Q W m F v pp � I J LO Q O C M Z v 0 J W LE -I W tY z o 0 O = Z J o Z L o w (n Lc) I Q w Wr��F . , P. F: n w w w 7v a ul O r fn fn r o W U 0 (9 O x � U x U x U 1BY WOOD BUCKS v Q ° N O Z 0 Z 0 Z Q N co O O O Q�?� to CD Q 0592 • N ~ ?ROIDUCT REVISED — m as complying with the Florida O +� Building Code •D.2, 1 ! �{� e (YJ = � v U Acceptance ���•, • 6lYE OF �� drawing no. 7By �'�i�YON ade Product of i/11Iill� sheet 6 of 1 1 FnrF nicT MIAMI—DADE COUNTY APPROVED EDGE DIST. MEAL UCTURE MULLION & MULLION ANCHORS STR SEE SEPARATE NOA EDGE DIST. i u�v u E E12 ;i- TYPICAL ANCHORS SEE ELEV. FOR SPACING S TYPICAL ANCHORS SEE ELEV. FOR SPACING 1 /4" MAX. O SHIMS TYPICAL ANCHORS ALT. SEE ELEV. FOR SPACING a• W C9 ' W G p W D . d WINDOW WIDTH INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER SEE SHEETS 4 & 6 FOR WINDOW DETAILS PRODUCT REVISED Ps co -Plying with the Florida Su:Iding Code Acceptance 140 ta•oz21.o3 Expiation Date m*6-22 Uco Go co I co Z °° h 0 Z m Q 1-•ul N 0 �y o ii O0`p 0 O WN Ixc1 (0 m V G Wei 0 m 0 0 aaQ 0��� 0 aLLI�ZI ul a ZN -0 QLu woMi� J Go 0 L0 00 M) J Q 0 � M Z v Jp J W of J W D' zu v7 oN 0 2) p - alo = Z�_ `O Z LL- o 04 0 O w W M ILL-, u-M1a1m1"I I J 712 e T e X= p V f0 Y � U p S OF e��q�\ drawing no. ��•• ...RION.W16-86 ����i ®Gj �� \� ���` sheet 7 of 11 TYPICAL ANCHORS ILLUSTRATIVE DTLS. ONLY SEE ELEV. EXT. OR INT. FINISHES FOR SPACING NOT BY E.S. WDW. z �a -44 O ALT. O ALT. #10 TEKS/SELF DRILLING SCREWS AT 6 FROM ENDS AND 12 O.C. MAX. #10 TEKS/SELF DRILLING SCREWS AT 6 FROM ENDS AND 12 O.C. MAX. z M a C-4 \ TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING #10 WOOD SCREWS (GRADE 2 CRS) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD 1 /4" MAX. GAP 1/2" MIN. TYPICAL ANCHORS SEE ELEV. FOR SPACING 0 ALT. #10 TEKS/SELF DRILLING SCREWS AT 6 FROM ENDS AND 12 O.C. MAX. EXTERIOR WINDOW WIDTH U W c0 00 co Z OZ M� �LLI ?�N a.. a' C 0 , 0 OI LU N O�ivh w� o�0>-mo paaQ A 0 cl Q LL, ,LOO ZU) -o o� C7 <D Q W (7) F J 00 o� to 1 M J Q O U Z v J J w 0 J LLJ zc oN 0 p 03 = Z�� `0 o Z o J 6 0 — v W IIJ R) m F \�I�Illlili/rr� Ul�l`Iml"I I 1 INSTALLATION DETAILS WITH FIN FRAME ADAPTER Jr- Q�'°®�� SEE SHEETS 4 & 6 FOR WINDOW DETAILS n ` � N OfFa- N 592 PRODUCT REVISED �— as e' Plying with the Florida V tnB tild2S; Building Code . As eptanceNo I a'j.�� o' iEOP °�1�� drawing no. Expiration Date �d ?12 � '° . oa��®�.•°'moo ,� W 16-86 Mi ,sde roduct X\'%sheet 8 of 1 1 tlllllll ITEM # PART # REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS E1 ES—EL104 1 FRAME HEAD 6063—T6 — E2 ES—EL201 1 FRAME SILL 6063—T6 — E3 ES—EL202 1 SILL TRACK 6063—T6 — E4 ES—EL102 2 FRAME JAMB (OPERATING) 6063—T6 — E4.1 ES—EL101A 2 FRAME JAMB (FIXED) 6063—T6 — E5 ES—EL105 1 INTERLOCK STILE 6063—T6 — E6 ES—EL106 1 JAMB STILE 6063—T6 — E7 ES—EL107 2 VENT TOP & BOTTOM RAIL 6063—T6 — E8 ES—EL108A 1 FIXED MTG. STILE 6063—T6 — E9 ES—EL109 AS RQD. GLAZING BEAD (5/16" LAM. GLASS) 6063—T6 — E10 ES—EL110 AS RQD. GLAZING BEAD (7/16" LAM. GLASS) 6063—T6 — Ell ES—EL111 AS RQD. GLAZING BEAD (INSUL LAM. GLASS) 6063—T6 — E12 ES—EL112 AS REQD. FLUSH FRAME ADAPTER 6063—T6 — E13 ES—EL115 AS REQD. FLUSH FRAME ADAPTER WITH FIN 6063—T5 — E14 ES—EL114 AS REQD. HEAD SCREW COVER 6063—T6 — E15 ES-2011 AS REQD. SILL RISER 6063—T6 — E16 ES—EL220 AS REQD. INTERLOCK STILE STIFFENER 6005—T5 — E17 ES—EL221 AS REQD. FIX. MTG. STILE STIFFENER 6005—T5 — E18 ES—EL113A AS REQD. JAMB SCREW COVER 6063—T6 — M1 ES-5008A AS REQD. GLAZING BEAD BULB SILICONE DUROMETER 60±5 SHORE A M2 80-372A 2/ LITE SETTING BLOCK AT 1/4 POINTS (LAM. GLASS) SILICONE DUROMETER 80±5 SHORE A M3 EL100—BOl 2/ LITE SETTING BLOCK AT 1/4 POINTS (INSUL. LAM. GLASS) SILICONE DUROMETER 80±5 SHORE A M4 EL100-301 AS REQD. VENT STOP RIGID PVC — M5 W23211 NG AS REQD. PILE W'STRIPPING WITH PLASTIC FIN POLYPROPYLENE — M6 SKOB-4010 2/ VENT SPRING LOADED LATCH 6063—T6 ALTERNATE TO SWEEP LATCH M7 ES-1012 2/ LATCH LATCH SPRING ST. STEEL — M8 SL302—XX 2/ VENT SWEEP LATCH DIE CAST ALUM — M9 WA21- 2 WEEP HOLE COVER RIGID PVC — M10 ES-1000—PIL — LEFT NOTCH CAP NYLON — M11 ES-1000—PlR — RIGHT NOTCH CAP NYLON — M12 WPSA—N1 2 3/4" X 3/4" RETIC FOAM PAD FOAM — M13 TAR-16019P—A 2 ROLLER POLYAMIDE & ACETAL — M14 TAR-16019P 2 ROLLER HOUSING POLYAMIDE — M15 #8 X 1" — FLUSH FRAME ADAPTER ASSEMBLY FASTENERS ST. STEEL FH SMS M16 #8 X 1" — FRAME AND VENT ASSEMBLY FASTENERS ST. STEEL PH SMS M17 #8 X 3" — FRAME SILL ASSEMBLY FASTENERS ST. STEEL PH SMS M18 #8 X 3/4" — SWEEP LATCH FASTENERS ST. STEEL FH SMS M20 #14 X 3/4" — ASSEMBLY FASTENERS FOR FLUSH ADAPTER ST. STEEL PH SMS PRODUCT REVISED as cemplying with the Florida' Building Code 2 2 Arcptance No ia•O'Z I A � n E. i Date �.v�` mywr Pa�i�t' ade Product Corm r V � w m m I co Z Q i OZ M�4 F' u N 1 a o L6 O0`p U a �N U. 0801, v p ui ci �O>M o Q C�Op a .I O °-� Q XZj N W y U. p J ZMQ QWm J m m o to 3 co � to m J 117 0 V° v z J C) -J W of ON 0 cy) ul; p n ao = Z�� co a �' Z L L- o w (!1 O cis LaJ w 0. m m � T OF drawing no. 6-86 /////ill%t���� sheet 9 of 11 s® i5 E6 JAMB STILE FRAME HEAD 1.938 .050 TYP. 62 1.187 .0] i FA 1.474 FRAME SILL .062 .312 .250 SILL TRACK FRAME JAMB (OPERATING) )0 1.407 1�1.313�1 INTERLOCK STILE FIXED MTG. STILE 719 1.187 41 2.917 1 062 1 2.987 .050 NP. 1.187 L�1.625 1.562_ E4.1 FRAME JAMB (FIXED) 1.187 .683 1.308 37 062 1.260 -- OVENT TOP/BOTTOM RAIL 1.122 1.421 1.078 .07� Ms SPRING LOADED LATCH F .040 1.740 t-.277 E18 JAMB SCREW COVER 040 .308 1625 E14 HEAD SCREW COVER 2.857 �- .045 .500 625 I� 2.780-- �I E12 FLUSH FRAME ADAPTER F= -1.428 --1 1.500 L .500 .045 J II� 2.780 FLUSH FRAME ADAPTER WITH FIN .063 .625 1.633 � .519 T1 .6EM4 6E050 .974 M .202 E10 J I .202 E9 GLAZING BEADS 188 J .125 1.025 -d .708 I� INTERLOCK STILE STIFFENER 1-�.513 1.233 ,125 --]�- 1.013 -d .826 fo- FIX. MTG. STILE STIFFENER .165 �1 F -- .068 2.500 �� 2.000 046 1 SILL RISER I.135 [t 0W. 4 to 625 .062 974 Z m % -� p z M N ¢I I .202 a ul cmv E11 V a p O 0 O ` O U d ; N m ul L] F Gm C�oWl-, CY 0 m o p If < O 2� um) CZ0 O LL Z Q W J to In 0 L0 3 0 r) g J o cD z J -j w G✓ NNE z N O_ rn� p m M o Z � o v LLI w Lj o WL-iW W W = = _ En cn in N V cn O F F F- in c 0 a or � \ r N 7 2 -_ N PRODUCT lZEVISED as complying with the Florida � � s � ► � ° o u � L Building Code 1 s Acceptance i lc3212®� 8y OF ^ °�2q�� drawing no. Er.r*aitcttt TYstegm. •° k0ffil* ... �jy�� 1�y Product '''/1®N�; `� W 16 - 8 6 1,1eii1111 sheet 10of 11 VENT TOP & BOTTOM CORNER I I 1 FIX. MTG. RAIL CORNER FRAME BOTTOM CORNER �i E . I I -- iu\ --INII"IN III FIN FRAME ADAPTER CORNER PRODUCT REVISED as complying with the Florida Building Code �—O'ZZI. Q Acceptmm I30 T;xpiration Date Product 2V co I Z O Z M C Q 1- W a N 1 a' C0o 0 0 WN 0 C ni ci Cr0?: o 0 0R, . O Q 0 otjI IX 0 Q W�j �^p L< Z N O M Q W 0M1 Lr FW�- J � I 00 M Q o C.D M Z v J J L,.1 Z � n 0 � � 00 = Z�� `n o �Z`` o so w LLJ 1 ```eIll�lllll�/��� U1=1`Iml"I J ANC ��°' �s s�` °••� ' ! s N \ F m e e Xz O O Y U OIL �2�� drawing no. ,e��• .... W16-86 '�i�o�NG°ll�,� sheet 11 of 11