HomeMy WebLinkAboutBuilding PlansO COVERED PATIO MASTER BEDROOM rrr / II � II ®I BKST ® I NOOK F_ — ff—O—' Ii ® � � PATIO Oi II I\ / I I KITCHEN I I MASTER BATHROOM ® j ISO) <® W.I.C. HALLWAY 0 _ LAUNDRY F=�� K PAN.® \\ © / @ F /x\�r0 �� CL. / \ I � 'y�^q�✓ III` L--J-JL7 DINING ROOM II j FOYER DEMO PLAN a"=1' SCALE DEMO LEGEND - - - - - - EXISTING TO BE REMOVED EXISTING TO REMAIN it r - -n II \ (2) / II II � r II FAMILY ROOM F.P. LIVING ROOM DEMO NOTES: �1 REMOVE ALL WINDOWS, FRAMES AND ASSOCIATED HARDWARE ® REMOVE ALL EXTERIOR DOORS, FRAMES AND ASSOCIATED HARDWARE BEDROOM # 2 03 REMOVE EXISTING MASTER BATH VANITY, VALVES AND ASSOCIATED HARDWARE ® REMOVE EXISTING MASTER BATH TUB AND HARDWARE QS REMOVE EXISTING MASTER BATH TOILET, VALVE AND ASSOCIATED HARDWARE jr- II \\ 1 I © REMOVE EXISTING MASTER BATH SHOWER. MIXING VALVE, TILE WALL BOARD II \ AND ASSOCIATED HARDWARE ® ! O7 REMOVE EXISTING FLOOR TILE CLOSET t ® REMOVE FOR RELOCATION EXISTING WASHER AND DRYER onO I REMOVE EXISTING KITCHEN COUNTERS �J � REMOVE EXISTING KITCHEN UPPER AND LOWER CABINETS ® REMOVE EXISTING DOUBLE OVEN �4* BATH #2 REMOVE EXISTING REFRIGERATOR REMOVE EXISTING STOVE REMOVE EXISTING DOUBLE SINK, VALVES AND ASSOCIATED HARDWARE ® REMOVE EXISTING KITCHEN EXHAUST HOOD ul ® REMOVE EXISTING TUB AND HARDWARE IN BATH #2 ® DEN © REMOVE EXISTING HOT AND COLD WATER LINES IN TUB/SHOWER PREPARE LINES FOR EXTENSION. I ® REMOVE EXISTING TUB/SHOWER SANITARY LINE AND PREPARE LINE FOR EXTENSION II REMOVE EXISTING WALL BETWEEN TUB AND TOILET ® REMOVE EXISTING VANITY IN BATH #2 REMOVE EXISTING SINK, VALVES AND ASSOCIATED HARDWARE CLOSET CLOSET ® REMOVE EXISTING TOILET, VALVE AND HARDWARE G3 mm ® REMOVE OR REPAIR ALL INTERIOR DOORS REMOVE EXISTING INTERCOM SYSTEM, SPEAKERS AND ASSOCIATED WIRING IN HOME REMOVE EXISTING STEREO SYSTEM SPEAKERS AND WIRING IN HOME IL -- I 1 I REMOVE ALL CEILING LIGHT FIXTURES AND WIRING TO SOURCE ® REMOVE ALL EXISTING CEILING FANS ® ® REMOVE ALL EXISTING BLOWN -IN INSULATION THRU-OUT ATTIC BEDROOM # 3 ® REMOVE EXISTING URINAL. REMOVE EXISTING COLD WATER LINE TO SOURCE AND CAP. ® REMOVE EXISTING URINAL SANITARY LINE AND CAP - ® REMOVE AND RELOCATE EXISTING WATER HEATER Q REMOVE EXISTING HVAC SYSTEM INCLUDING ALL DUCTWORK, DIFFUSERS, RETURNS, AIR HANDLER (IN ATTIC), COMPRESSOR AND ALL ASSOCIATED HARDWARE/WIRING ® REMOVE AND RELOCATE EXISTING LAUNDRY ROOM WASH TUB DEMO SOFFIT ABOVE EXISTING MASTER BATH SHOWER. FIELD VERIFY NON-STRUCTURAL. ® DEMO SOFFIT ABOVE BATH #2 TUB/SHOWER. FIELD VERIFY NON-STRUCTURAL. ® REMOVE EXISTING HEAT LAMP WIRING AND SWITCH IN MASTER BATH smai- 4r co ® INFILL REMOVED WINDOW IN GARAGE r.>Ck-c� dr�' ® DEMO EXISTING WALL BETWEEN CLOSET AND DINING ROOM R. ® REMOVE EXISTING CLOSET LIGHTING WIRING AND SWITCH IN BEDROOM #3 `v DUE TO THE NATURE OF THE PROJECT THE CONTRACTOR SHALL VERIFY ALL ASSUMPTIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY ENGINEER IF CONDITIONS DIFFER FROM NOTED. i ® REMOVE & RELOCATE EXISTING SINK ® REMOVE EXISTING WOOD FENCE REVIEWED FOR T® REMOVE EXISTING WHOLE HOUSE EXHAUST FAN SYSTEM CODE COMPLIANCE ® REMOVE WIRE SHELVING WHERE EXISTS ST, LUCIE COUNTY ® REMOVE CARPETING BOCC REMOVE EXISTING MIRROR ® REMOVE & RELOCATE EXISTING CABINETS ©� - ® REMOVE EXISTING MEDICINE CABINET l SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL. PE # 66080 -0 AT,F'�/j Ott xN i��iFSS�ONA 0 a a w Q Q z 0 w a 1--I O QI W � x M x DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 Aml PATIO 19'-4" 10'-22" 10'-991 I127 6 p ;! ---CH 8'-6" T� --- I MASTER BEDROOM CH 10'-0" l �1 3 CH 8'-6" 2'-4" LMASTER BATHROOM CI CH 8'-6" O W.I.C. CH 8'-6" I o © I 81011 I-�—J 010 GARAGE CH 10'-0" 0 23'-4" Desian Loads COVERED PATIO �s 0 0 III® BKST NOOK CH 8'-6" �i -- ----- i - ® 1 i KITCHEN CH 8 6 I I I00—� IN - HALLWAY ® CH 8'-60' j PAN. ; CH 8'-6" lowCL 121 ® FOYER i DINING ROOMi 1 CH 8'-6" CH 10'-0" WH CH 8'-6" ­­ Y;7 Roof Live Load: 20.0 p.s.f. Wind Speed: 160 MPH (3 second gusts) Building Category: II Wind Exposure: C Internal Pressure Coefficent: +/-0.18 Structure Designed: Enclosed Soil bearing capacity. 2000 p.s.f. r GENERAL NOTES: CH 8'-6" 17 1� I LIVING ROOM I CH 10'-0" I( CH 8'-6" NOTE: REPLACE ALL INSULATION OVER LIVING AREAS WITH R30 BATT OR BLOWN -IN INSULATION NOTE: REPLACE INTERIOR GYP BOARD PER OWNER PROPOSED FLOOR PLAN 4"=1' SCALE 1. CLEAN ALL WOOD WOODWORK, PATCH EXISTING CEILING AND/OR WALL FINISHES TO MATCH EXISTING AS REQUIRED. 2. ALL CONSTRUCTION SHALL CONFORM TO 2017 FLORIDA RESIDENTIAL BUILDING CODE ALONG WITH AMENDMENTS AND LOCAL CODES. 3. FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ORDERING ALL MATERIALS, 4. INSTALL ALL MATERIALS PER MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 5. REMOVE HAZARDOUS MATERIALS, IF THEY EXIST, PER LOCAL OSHA AND EPA STANDARDS. CONTRACTOR SHALL BE RESPONSIBLE TO DETERMINE WHICH, IF ANY, MATERIALS ARE HAZARDOUS PRIOR TO REMOVAL. 6. ALL DIMENSIONS SHOWN ARE PLUS MINUS. BEDROOM # 2 CH 8'-6" DEN CH 8'-6" CLOSET I I ri nSFT BEDROOM # 3 CH 8'-6" a I NEW MASTER BATH CLOSET AND GUN SAFE STORAGE CEILING HEIGHT TO BE T-0" IN CLOSET WITH OPEN STORAGE ABOVE REPLACE EXISTING MEDICINE CABINET IN MASTER BATH ® NEW FOLDING TABLE IN LAUNDRY ROOM WITH HANGING RACK ABOVE ® REMOVE ALL WIRE SHELVING IN CLOSETS AND REPLACE WITH NEW WINDOW SCHEDULE MARK M.O. SIZE TYPE REMARKS SH25 27" x 57" Singlehung Impact H33 26-7/8" x 37-7/8" Singlehung Impact SH35 37-1/2"x76-1/2" Singlehung Impact SH2756 37 3/4" x 82" Singlehung Impact FX4637 39-1/2"x46-1/2" Fixed Glass Impact HR3636 37-3/4" x 37" olleon a Impact SH26 37-3/4" x 76" Singlehung Impact FX5356 53-5/8"X57" Fixed Glass Impact All windows to have white frames and clear glass except where noted. Use frosted glass at bath #2. Install new windows in existing openings unless noted otherwise. Field verify window sizes prior to purchasing. SCODe of Work Single level CBS single family residence renovation Building Code 2017 Florida Building Code: Residential 2014 National Electric Code AREA SCHEDULE LIVING AREA 2472 SQ. FT. GARAGE 633 SQ. FT. PATIO 467 SQ. FT. ENTRY 9 SQ. FT. TOTAL 3581 SQ. FT. DOOR SCHEDULE O Exterior Doors Interior Doors Size Type 0 3080 Swing Door w/(2) Side Lite ® 16' x 8' Overhead Steel © 2868 Garage Service Door ® 5068 Sliding Glass Door 3068 Swing Door (2) 6068 Sliding Glass Door 2668 Swing Door ® 2668 H.C. Swing Door E� 2468 H.C. Swing Door 10 3068 H.C. Swing Door UF 2668 H.C. Pocket Door 2 (2)2668 H.C. Pocket Door 13 2668 H.C. Bifold 4 2068 H.C. Bifold 1 3068 H.C. Bifold rIT 4068 H.C. Bifold 1 6068 H.C. Bifold 1® 2668 Swing Door Self Closing SC W/Weather Strip 1® 2068 H.C. Bifold All doors to have white framer. and clear glass except where noted. Use frosted glass at bath #2. Install new doors in existing openings unless noted otherwise. Field verify window sizes prior to purchasing. NEW WORK NOTES: O NEW WINDOW, FRAMES AND ASSOCIATED HARDWARE O NEW EXTERIOR DOOR, FRAMES AND ASSOCIATED HARDWARE Q NOT USED ® NEW MASTER BATH CLOSET © NOT USED ® NEW MASTER BATH SHOWER, TILE, CEMENT WALL BOARD, GLASS SHOWER DOOR, FRAME, SHOWER BENCH, FIXTURES AND NEW BACKING FOR GRAB BARS. PATCH CEILING ABOVE. NEW TILE FLOOR ® RELOCATED WASHER AND DRYER 0 NEW KITCHEN COUNTERTOP ® NEW KITCHEN UPPER AND LOWER CABINETS ® NEW DOUBLE OVEN IN EXISTING LOCATION ® NEW REFRIGERATOR IN EXISTING LOCATION ® NEW COOK TOP IN EXISTING LOCATION ® NEW DOUBLE SINK VALVES AND ASSOCIATED HARDWARE CENTER ON NEW WINDOW NEW SHOWER, PAN, FIXTURES, CEMENT BOARD & TILE FINISHES AT BATH #2. PATCH CEILING ABOVE. ® NEW VANITY NEW SINK, VALVES AND ASSOCIATED HARDWARE IN EXISTING LOCATION ® NEW TOILET, VALVE AND HARDWARE IN EXISTING LOCATION ® REPAIRED OR NEW INTERIOR DOOR ® NEW CEILING LIGHT FIXTURES AND WIRING THROUGHOUT HOME. SEE ELECTRICAL DRAWING. ® NEW R30 BLOWN -IN OR BATT INSULATION IN ATTIC ® RELOCATED EXISTING WATER HEATER ® RELOCATED CABINETS. MODIFY EXISTING DRYER VENT, WATER SUPPLY & DRAIN AS REQUIRED. ® NOT USED ® EXTEND LAUNDRY ROOM WASH TUB HOT AND COLD WATER LINES TO NEW LOCATION NOT USED NOT USED ® RELOCATE HOT AND COLD WATER LINES AS NEEDED FOR NEW SHOWER IN BATH #2 ® NEW 24" HIGH BENCH SEAT IN MASTER BEDROOM ® RAISE SILL IN MASTER BEDROOM TO 26-1/2". INFILL PER DETAILS ON SHEET A-3. ® RAISE SILLS IN BREAKFAST NOOK TO 35-1/2". INFILL PER DETAILS ON SHEET A-3. ® NEW 2X4 STUDS SPA. @ 8" O.C. W/ }" GYP BOARD EACH SIDE ® NEW RANGE HOOD DUCT TO EXTERIOR OF HOME 0 NEW OWNER SUPPLIED REVERSE OSMOSIS WATER SYSTEM UNDER KITCHEN SINK. RUN WATER LINE TO REFRIGERATOR. NEW FLOORING PER OWNER SPECS RELOCATED EXISTING SINK © NEW FOLDING TABLE HUNG FROM ABOVE ® NEW MEDICINE CABINET ® NEW ENLARGED PATIO AREA WITH PRIVACY LANDSCAPING PER OWNER SPECS ® NEW MASONRY WALL INFILL. SEE DETAILS ON SHEET A-3. SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FLPE #66080 CNN >(a•%--.-� `Y �'1GENS No. �}E�W ti 1 �r1\\NNN z 0 a U w Q a Q z 0 w a DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 A=2 TILE WALL FINISH 1/2" CEMENT BOARD SLOPED MORTER BED REINFORCED W/2X2 WELDED WIRE MESH WATRPROOFMEMBRANE TILED SURFACE —� DRAIN REINFORCED CONCRETE CURB BONDED TO SLAB I.•�� _ — _ .d EXISTING CONCRETE ., a -. o... • G .. ,.e SHOWER PAN DETAIL NOT TO SCALE NEW SLAB INFILL: MATCH EX. THICKNESS. #5 DOWEL X V-0" LNG. SPA. @ V-4" O.C. EPDXIED 6" INTO CONCRETE SLAB (TYP.) EXISTING CONCRETE SLAB COMPACTED FILL SAWCUT EXISTI HOT & COLD WATER LINES CONCRETE SLAB INSULATED FULL DEPTH NEW SANITARY SEWER PIPE TO MATCH ELEVATION & GRADE FOR TIE-IN TO EXISTING SEWER LINE SLAB TRENCHING DETAIL NOT TO SCALE PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures #12 SMS W/Min. 9/16 Edge Distance and 1-3/8" Min NOA 20-0401.03 S.H. Windows SH5500 PGT Impact P Embedment thru 1" P.T. S.Y.P. +33.5/— 44.8 +65/— 70.0 NOA 20-0427.05 French Door FD5555 PGT Impact #10 SMS (G5) 1/2" Min Edge Distance and 1-3/8" Min +33.5/— 44.8 +/— 50.0 Embedment thru 1" P.T. S.Y.P. #12 SMS (G5)W/Min. 9/16 Edge Distance and 1-3/8" Min NOA 17-0420.06 Sliding Glass Door SGD SERIES 5570 PGT Impact Embedment thru 1" P.T. S.Y.P. +33.5/— 44.8 +/— 60.0 #12 SMS W/Mina 9/16 Edge Distance and 1-3/8" Min NOA 20-0401.07 Fixed Window PW5540 PGT Impact P Embedment thru 1" P.T. S.Y.P. +33.5/— 44.8 +/— 50.0 #12 SMS W/Min. 9/16 Edge Distance and 1-3/8" Min NOA 20-0406.01 Horizontal Roller HR5510 PGT Impact Embedment thru 1" P.T. S.Y.P. +33.5/— 44.8 +/— 50.0 #12 SMS W/Min. 9/16 Edge Distance and 1-3/8" Min NOA 20-0401.16 Fixed Window PW5520 PGT Impact P Embedment thru 1" P.T. S.Y.P. +33.5/— 44.8 +/— 70.0 FL# 15180.7 Swing Door Opaque FG "Single Door w/ Plastpro Impact 1 4" Tapcon w/min. embedment of 1-1/4" and Min Clearance to masonry edge 2" and Min Clearance to +33.5/— 44.8 +/— 50.0 Impact Sidelights Adjacent Anchor 4 FL 15213.1 # SwingDoor Opaque FG Plastpro Impact P 1 4" Tapcon w/min. embedment of 1-1/4" and Min Clearance to Clearance to +33.5/— 44.8 +/— 65.0 Single Door masonry edge 2" and Min Adjacent Anchor 4 FL# 5684.14 Overhead Door W18-16 Clopay Impact 1/4" X 1-1/4" Embed ITW Tapcons @ 3"/18"O.C. +33.5/— 44.8 +/— 47.2 NEW SIMPSO 1 EXISTING SP, NEW (2)-5/8" EXPAN.' ANCHOR W/PLATE WASHER & WITH 6" MINIMUM EMBEDM INTO EXISTING CONCF EXISTING PI EXISTING FOOTING J (2) 2X4 SILL PLATES LING 2X4 STUDS (TYP) PROVIDE NEW STUCCO, LATH AND WATER RESISTANT BARRIER. FINISH TO MATCH EXISTING. PROVIDE NEW PLYWOOD WALL SHEATHING. THICKNESS TO MATCH EXISTING. FASTEN W/8d NAILS SPACED @ 6" O.C. NEW R13 BATT INSULATION EXISTING PLATE _.. 4 P.T. BOTTOM PLATE EXISTING WINDOW INFILL DETAIL (WOOD FRAMED WALL) 1"=1' SCALE NEW WINDOW OPENING DRILL & VERTICF INTO EX SPA. @: TYP. EXISTIN BEAM ()v EXISTIN (VIF) NEW 8" INFILL #3x1'-0' SPA. @ AND EP( INTO EX CELL (T' DRILL & DOWELf INTO EX LAP MIN @ T-B" EXISTIN SILL (VI EXISTIN (VIF) EXIST:1.W I WWIZ1.V (VIF) v - a' a W NEW #5 DOWEL SPACED @ 2'-8" O.C. EPDXIED 8" INTO EXISTING EXISTING WINDOW MASONRY OPENING INFILL DETAIL EXISTING 3" DIA. STEEL COLUMN NEW COLUMN WRAP NEW WINDOW OPENING a o• 4 1 21 =1' SCALE EXISTING MASONRY WALL NEW 8" X 8" CONCRETE SILL W/ (2) #5 EPDXIED 6" INTO EXISTING MASONRY FILLED CELL PROVIDE NEW STUCCO FINISH TO MATCH EXISTING NEW 8" MASONRY INFILL NEW (2) #3 XV-0" LONG DOWEL EPDXIED 4" INTO EXISTING WALL (TYP) �. .. m 4 .. e z a EXISTING MASONRY WALL EXISTING FOOTING EXISTING WINDOW INFILL DETAIL (MASONRY WALL) 1"=1' SCALE SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE # 66080 z 0 u w Q a Q z 0 5 w a DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 A=3 ■ MA TER BEDROOM I - TI Q MASTER BATHROOM I CL. V Al T f r--- LAUNI d NOTE: NEW GARAGE LIGHTING TO BE CHOSEN BY OWNER NOOK KITCHf 1 F- — �- c` --T BF,L r -11 -,CAI----1 OVN I�y �. �l 1 i �< a. HALLWAY "� i Y.PANF--- \ II WH DININGROOM' FO ER f t! t FAMILY ROOM t � ( F. P. 0 1 1 REMOVE EXISTING MIRROR ADD I BACKING R TV MOUNT fl LIVING ROOM j r X/l 1 I NOTES: REPLACE ALL OUTLETS AND SWITCHES WITH WHITE DECORA BY LEVITON DIMMER SWITCHES ARE TO BE INSTALLED ON ALL RECESSED LIGHTING EXCEPT IN BATHROOMS AND CLOSETS REMOVE ALL EXISTING CEILING LIGHTING, WIRING AND SWITCHES TO SOURCE REPLACE ALL EXTERIOR LIGHT FIXTURES IN SAME LOCATION PROVIDE NEW BATHROOM EXHAUST FAN/LIGHT COMBO ELECTRICAL PLAN J"=1' SCALE ( i "BEDROOM 412 CL. CLOSET ( C) ap BATH #2 CL CL I 1 l� ( EDROOM # 3 SH25 ELECTRICAL LEGEND 4" RECESSED LED CAN LIGHT VAPOR PROOF SURFACE MOUNTED LIGHT Fa -� PENDANT LIGHT FIXTURE. F-----`-3 SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ®� UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT FIXTURE CARBON/SMOKE DETECTOR JUNCTION BOX CEILING FAN WITH NO LIGHT CARBON MONOXIDE DETECTOR CEILING FAN WITH LIGHT L7L7OR CHIMES ` SMOKE DETECTOR RECESSED INCANDESCENT LIGHT TV TELEVISION FIXTURE WITH EXHAUST FAN THERMOSTAT 7PH TELEPHONE € UPLEX OUTLET - SWITCHED 0 PUSH BUTTON DUPLEX OUTLET SWITCH 220 V CUTLET DIMMER SWITCH GROUND FAULT INTERRUPTER THREE WAY SWITCH WP WEATHER PROOF GROUND FAULT 4 QUAD OUTLET NOTEE. RECEPTACLES IN KITCHEN & BATH AREAS TO RE Ali" A.F.F. ALL 920V SINGLE PHASE 95 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCL TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 95 & SC AMP BRANCH CIRCUITS GENERAL ELECTRICAL NOTES ALL BEDROOM, FAMILY ROOM, DENS,DINING ROOM LIVING ROOM CLOSETS HALLWAYS CLOSETS CIRCUITS TO BE ON ARC FAULT BREAKERS PROVIDE PHONE AND TV OUTLETS. VERIFY LOCATIONS. RUN HVAC WIRES AS REQUIRED. ALL BATH AND KITCHEN OUTLETS WHERE NOTED TO HAVE GROUND FAULT INTERRUPT SMOKE DETECTORS TO BE HARD WIRED TO MAIN HOUSE WITH BATTERY BACK UP MICROWAVE OUTLETS TO HAVE DEDICATED CIRCUITS PROVIDE LEGIBLE DIRECTORY @ PANEL INDICATING INDIVIDUAL CIRCUITS DO NOT SCALE DRAWNGS REFER TO FLOOR PLAN ALL WORK DONE SHALL COMPLY W/ ALL LOCAL STATE AND 2014 NEC ,4t.,, SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN 3. MASKOL FLPE #6( z 0 a a w Q Q z O W x DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 Eml HVAC LEGEND SUPPLY DIFFUSER RETURN DIFFUSER — — — SUPPLY DUCT — - RETURN DUCT MECHANICAL PLAN If =1' SCALE ,A'ik,SUMMiT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE " 03 PORT SAINT`LUCIE FL 34984 (772) 285-0572 BRIAN J. MASKOL FL PE # 66090 60 *, No. 66C (l STATE Of W � 0 tt/ \ j/�,p . FCOR10',P,' O a U W Q a Q a 5 a ' DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 I MMI ,,, SUMMIT DESIGN & FORENSICS, INC. SLOPE TOWARD DRAIN CLEANOUT-TYPICAL - DIMENSION TO BE A SEE MINIMUM OF 1" PLUS DETAIL AIR CONDITION UNIT NOTE SUPPLY FAN BLOCKED TIGHT STATIC PRESSURE STATIC PRESSURE PLUS 1" DRAIN PAN DRAIN LINE SHALL BE, AS A MINIMUM, THE SAME SIZE AS THE DRAIN PAN CONNECTION. 1" WATER SEAL DETAIL NOTE USE CLEAR PLASTIC'EASY TRAP' WITH OVERFLOW SHUTDOWN SWITCH ALL OTHER MATERIALS SHALL BE PVC UNLESS NOTED OTHERWISE. MECHANICAL NOTES: 1. REFER TO FLOOR PLANS TO VERIFY ALL CONDITIONS PRIOR TO BIDDING OR START OF CONSTRUCTION. 2. ALL WORK SHALL BE EXECUTED AND INSPECTED IN ACCORDANCE WITH ALL LOCAL AND STATE CODES, LAWS, ORDINANCES, RULES AND REGULATIONS APPLICABLE TO THE PARTICULAR CLASS OF WORK. IF, TO THE KNOWLEDGE OF THE CONTRACTOR, THE DRAWINGS AND SPECIFICATIONS ARE IN CONFLICT WITH THE ABOVE, HE SHALL PROMPTLY NOTIFY THE ENGINEER IN WRITING SO THAT ANY NECESSARY CHANGES CAN BE PROVIDED FOR IN HIS CONTRACT. IF THE CONTRACTOR PERFORMS ANY WORK WITHOUT NOTICE AS REQUIRED, HE SHALL BEAR ALL COSTS OF CORRECTIVE ACTION. 3. THE CONTRACTOR SHALL INCLUDE IN HIS QUOTATION ALL APPLICABLE SERVICE CHARGES, FEES, PERMITS, ROYALTIES, AND OTHER SIMILAR COSTS IN CONNECTION WITH THE WORK. OBTAIN PERMITS, AND REQUEST INSPECTIONS FROM AUTHORITY HAVING JURISDICTION. 4. INSTALL WORK IN LOCATIONS SHOWN ON DRAWINGS, UNLESS PREVENTED BY PROJECT CONDITIONS. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC, AND ALTHOUGH SIZE AND LOCATION OF EQUIPMENT ARE DRAWN TO SCALE WHENEVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND SHALL VERIFY THIS INFORMATION AT THE SITE. 5. THE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION OF PIPES AND DUCTS, AND SUGGEST PROPER ROUTES OF PIPE TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS AND PRESERVE CLEARANCES. HOWEVER, IT IS NOT INTENDED THAT DRAWINGS INDICATE ALL NECESSARY OFFSETS, AND IT SHALL BE THE WORK OF THIS SECTION TO INSTALL PIPING AND DUCTS IN SUCH A MANNER AS TO CONFORM TO STRUCTURE, AVOID ALL OBSTRUCTIONS, PRESERVE HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR WITHOUT FURTHER INSTRUCTION OR COST TO THE OWNER. 6. CONTRACTOR SHALL GUARANTEE ALL WORK PERFORMED UNDER THIS CONTRACT TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF WITNESSED AND APPROVED STARTUP. 7. MOTORS FOR ALL MECHANICAL EQUIPMENT SHALL BE FURNISHED BY SUPPLIERS OF SUCH EQUIPMENT AND SHALL BE THE TYPE THAT HAS CHARACTERISTICS SUITABLE FOR CONTINUOUS OPERATING CONDITIONS. 8. TRANSPORT AND HANDLE PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 9. STORE AND PROTECT PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, WITH SEALS AND LABELS INTACT AND LEGIBLE. 10. VERIFY THAT EACH PIECE OF EQUIPMENT OR SYSTEM HAS BEEN CHECKED FOR PROPER LUBRICATION, DRIVE ROTATION, BELT TENSION, CONTROL SEQUENCE, OR FOR OTHER CONDITIONS WHICH MAY CAUSE DAMAGE. 11. DEMONSTRATE OPERATION AND MAINTENANCE OF PRODUCTS TO OWNER'S PERSONNEL ONE WEEK PRIOR TO DATE OF FINAL INSPECTION. 12. EXECUTE FINAL CLEANING PRIOR TO FINAL PROJECT ASSESSMENT. 13. PROVIDE SUPPORT AND EQUIPMENT REQUIRED TO CONTROL EXPANSION AND CONTRACTION OF PIPING. PROVIDE LOOPS, PIPE OFFSETS, AND SWING JOINTS, OR EXPANSION JOINTS WHERE REQUIRED. 14. PROVIDE INSECT SCREENS FOR FRESH AIR INTAKES. 15. PROVIDE AND INSTALL REFRIGERANT PIPING FROM COOLING COILS TO CONDENSING UNITS. SUPPORT AS REQUIRED TO PREVENT SAGGING. PROVIDE ADDITIONAL CHARGE AS REQUIRED. INSULATED SUCTION LINE WITH ARMAFLEX. 16. CONDENSATE DRAIN PIPING SHALL BE SCH. 40 PVC OR TYPE "K" COPPER. 17. IF THE STRUCTURE HAS A CEILING, NON HEATED/COOLED SPACES ABOVE CEILING WILL HAVE EXHAUST VENTILATION WITH THERMOSTATS. ALL EXHAUST VENTS WILL WORK TOGETHER EXCEPT FOR STORAGE ROOM AND GARAGE, IF APPLICABLE, WHICH WILL HAVE ITS OWN SYSTEM. 18. PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINING DISSIMILAR METALS. 19. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS - "METAL AND FLEXIBLE", AND AS INDICATED. PROVIDE DUCT MATERIAL, GAGES, REINFORCING, AND SEALING FOR OPERATING PRESSURES INDICATED. 20. DUCT SIZES INDICATED ARE ACTUAL DUCT DIMENSIONS. ALLOWANCES HAVE BEEN MADE FOR THICKNESS OF INSULATION. ALL EXPOSED ROUND DUCTWORK SHALL BE DOUBLE WALL SPIRAL, WITH INTERNAL LINER, ALL ROUND DUCTS HIDDEN FROM VIEW SHALL BE WRAPPED WITH 1-1/2" THICK FOIL BACKED FIBERGLASS INSULATION. ALL RECTANGULAR DUCTS TO BE LINED WITH 1" THICK, MECHANICALLY FASTENED, FIBERGLASS INSULATION. 21. SIZE ROUND DUCTS INSTALLED IN PLACE OF RECTANGULAR DUCTS IN ACCORDANCE WITH ASHRAE TABLE OF EQUIVALENT RECTANGULAR AND ROUND DUCTS. 22. FLEXIBLE DUCTWORK SHALL BE EQUIVALENT TO OMNIAIR MODEL 1200 WITH 1" THICK FIBERGLASS INSULATION AND VAPOR FLEXIBLE DUCTWORK SHALL BE UL LISTED AND APPROVED BARRIER. FLEXIBLE DUCT SUPPORT HANGERS SHALL BE OF A TYPE TO PREVENT THE COLLAPSING OF FLEXIBLE DUCTWORK. WIRE SUPPORT HANGERS ARE UNACCEPTABLE. 23. SEAL ALL LONGITUDINAL AND TRANSVERSE SEAMS BEFORE APPLYING INSULATION. SEALANT SHALL BE NON -HARDENING, WATER RESISTANT, FIRE RESISTIVE, COMPATIBLE WITH MATING MATERIALS, LIQUID USED ALONE OR WITH TAPE, OR HEAVY MASTIC. 24. ROUND DUCTWORK SHALL USE A FLAT LOCK SEAM. SNAP LOCK DUCT IS NOT ACCEPTABLE. 26. LOCATE DUCTS WITH SUFFICIENT SPACE AROUND EQUIPMENT TO ALLOW NORMAL OPERATING AND MAINTENANCE ACTIVITIES. 26. PROVIDE CANVAS, FLAME RETARDING DUCT CONNECTORS AT ALL CONNECTIONS OF FANS TO DUCTWORK. 27. CONTROL WIRING SHALL BE PROVIDED IN CONDUIT IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL CODES. 28. WHERE APPLICABLE, ALL MECHANICAL PENETRATIONS THROUGH RATED PARTITIONS AND SLABS SHALL BE PER APPROVED U.L. LISTED PENETRATION DESIGN, PER 2003 INTERNATIONAL MECHANICAL CODE AND PER DETAIL(S) IN THESE DRAWINGS. VERIFY ALL WALL/PARTITION/SLAB RATINGS WITH ARCHITECTURAL DRAWINGS. 29. ALL TRUNK LINES FOR HVAC SHALL HAVE SMOKE DETECTOR WITH AUTOMATIC SYSTEM SHUT DOWNS (ALL HVAC SYSTEMS). 30. ALTERNATE HVAC EQUIPMENT SHALL BE OF THE SAME QUALITY, SPECIFICATIONS AND CAPABILITIES OF SPECIFIED EQUIPMENT OR BETTER. 31. PER 2003 INTERNATIONAL MECHANICAL CODE, SECTION 607.5.3, DUCT PENETRATIONS THROUGH FIRE PARTITIONS SHALL BE PROTECTED BY A FIRE DAMPER. FIRE RATED WALLS LESS THAN 1 HR RATING SHALL BE SEALED WITH FIRE CAULK. DUCT PENETRATIONS DO NOT REQUIRE FIRE DAMPERS PROVIDED THE FOLLOWING MINIMUM REQUIREMENTS ARE MET: 1) THE DUCT DOES NOT EXCEED 100 SQ. INCHES. 2) THE DUCT IS OF 0.0217 INCH MINIMUM STEEL. 3) THE DUCT SHALL NOT HAVE OPENINGS THAT COMMUNICATE THE CORRDOR WITH ADJACENT SPACES OR ROOMS. 4) THE DUCT IS INSTALLED ABOVE A CEILING. 5) THE DUCT SHALL NOT TERMINATE AT A WALL REGISTER IN THE FIRE -RESISTANCE -RATED WALL. 6) A MINIMUM 12 INCH -LONG BY 0.060-INCH-THICK STEEL SLEEVE SHALL BE CENTERED IN EACH DUCT OPENING. THIS SLEEVE SHALL BE SECURED TO BOTH SIDES OF THE WALL AND ALL FOUR SIDES OF THE SLEEVE WITH MIN. 1.5-INCH BY 1.5-INCH BY 0.060-INCH STEEL RETAINING ANGLES. THE RETAINING ANGLES SHALL BE SECURED TO THE SLEEVE AND THE WALL WITH NO. 10 (M5) SCREWS. THE ANNULAR SPACE BETWEEN THE STEEL SLEEVE AND THE WALL OPENING SHALL BE FILLED WITH ROCK (MINERAL) WOOL BATTING ON ALL SIDES. 32. ALL COMPONENTS SHALL COMPLY WITH THE SEISMIC REQUIREMENTS SPECIFIED IN ASCE-7 SECTION 9.6 CONDENSER SCHEDULE: TAG MANUFACTURER I MODEL NO. AMBIENT TEMP. ITONNAGE1 POWER M.C.A. M.O.C.P.IWEIGHTI NOTES CU1 I CARRIER I CAl 7NA03600GOAGI 90"F 1 3.0 1208/230/60/1 19.8 35 191 1 16 SEER / 13.0 EER CU2 I CARRIER I CA17NA036006 I 90"F 1 3.0 1 208/230/60/1 19-81 35 1 191 1 16 SEER / 13.0 EER AIR HANDLING UNIT SCHEDULE: TAG MANUFACTURER MODEL NO. NOM. CFM O.A. CFM KW POWER M.C.A. I M.O.C.P. WEIGHT I THERMOSTAT I FILTER FRAME I NOTES AHU1 CARRIER FV4CNF005L 1200 1 -- 1 3.5 208/230/1 5.4 1 1/60 1 172 1PROGRAMMABLE I YES AHU2 CARRIER FV4CNF005100 1 1200 1 110.015.4 1 1/60 1 172 1PROGRAMMABLE I YES RETURN AIR TYPICAL AIR COOLED CONDENSING UNIT. DO NOT LOCATE UNIT WHERE THE UPBLAST WILL STRIKE ANY --- FLEXIBLE DUCT CONNECTIONS OVERHANG CONTINUE REFRIGERANT PIPING TO OUTDOOR UNIT AIR HANDLER IN ATTIC TYPICAL SECONDARY CONDENSATE DRAIN PAN 2" HIGH X 2" LARGER THAN UNIT. PAN SHALL BE 18 GA. GALVANIZED SHEET METAL. CROSSED BRACED SEAMS SHALL BE SOLDERED. CORNERS TO BE WELDED AND PAINTED. CONDENSATE DRAIN (1/8" PER FOOT SLOPE) r TO BUILDING DRAIN BY GRAVITY SUPPLY AIR INSULATE FULLY TO PREVENT SWEATING AND DRIPPING. USE CLEAR PLASTIC'EASY TRAP' WITH OVERFLOW SHUTDOWN SWITCH ALL OTHER MATERIALS SHALL BE PVC UNLESS NOTED OTHERWISE. SEE CONDENSATE DRAIN DETAIL ON THIS SHEET FOR MORE ABOUT THE TRAP ALL VALVES, UNIONS, CONNECTIONS, ETC. SHALL BE INSTALLED OVER DRIP PAN CONNECTED TO CONDENSATE DRAIN SYSTEM AIR HANDLER DETAIL ANCHOR UNIT TO PAD WITH MIN. _ 1/4" DIA. EXPANSION BOLTS @ 1 112" EMBEDMENT DEPTH & NEOPRENE PAD. (TYPICAL FOR 4) SUCTION & LIQUID - REFRIGERANT LINES RUN REFRIGERANT LINES SHORTEST DISTANCE TO BLDG. EXTERIOR WALL. ri PAD TO BE 4" LARGER ALL AROUND THAN UNIT, EXISTING PAD CONDENSING UNIT DETAIL RISE IMUC6119 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 \GEN * 1, No. 66080 ro � S STATE OF ,, W' ®� ORtup, N��� /1111111, z 0 r~ a a u w Q Q O 5 w x 49 W0 W O F+I w DATE DESIGNED GMW 09-30-20 DRAWN GMW 09-30-20 CHECKED JOB NO. 2020-298 M=2